At least 325 records · Page 18

The decay of isotropic turbulence in a rapidly rotating frame

A direct numerical simulation of the decay of initially isotropic turbulence in a rapidly rotating frame was conducted. This 128 x 128 x 128 simulation was completed for a Reynolds number Re sub lambda = 15.3 and a Rossby number Ro sub lambda = 0.07 based on the initial turbulent kinetic energy and Taylor microscale. The numerical results indicate that the turbulence remains essentially isotropic during the major part of the decay (i.e., beyond the point where the turbulent kinetic energy has decayed to less than 10 percent of its initial value). The rapid rotation has the primary effect of shutting off the energy transfer so that the turbulence dissipation (and hence the rate of decay of the turbulent kinetic energy) is substantially reduced. Consequently, the anisotropy tensor remains essentially unchanged while the energy spectrum undergoes a nearly linear viscous decay (the same results that are predicted by Rapid Distortion Theory which is only formally valid for much shorter elapsed times. Surprisingly, no Taylor-Proudman reorganization of the flow to a two-dimensional state is observed. The implications that these results have on turbulence modeling are discussed briefly along with prospective future research.

Speziale, C. G.↗

Scaling laws for homogeneous turbulent shear flows in a rotating frame

The scaling properties of plane homogeneous turbulent shear flows in a rotating frame are examined mathematically by a direct analysis of the Navier-Stokes equations. It is proved that two such shear flows are dynamically similar if and only if their initial dimensionless energy spectrum E star (k star, 0), initial dimensionless shear rate SK sub 0/epsilon sub 0, initial Reynolds number K squared sub 0/nu epsilon sub 0, and the ration of the rotation rate to the shear rate omega/S are identical. Consequently, if universal equilibrium states exist, at high Reynolds numbers, they will only depend on the single parameter omega/S. The commonly assumed dependence of such equilibrium states on omega/S through the Richardson number Ri=-2(omega/S)(1-2 omega/S) is proven to be inconsistent with the full Navier-Stokes equations and to constitute no more than a weak approximation. To be more specific, Richardson number similarity is shown to only rigorously apply to certain low-order truncations of the Navier-Stokes equations (i.e., to certain second-order closure models) wherein closure is achieved at the second-moment level by assuming that the higher-order moments are a small perturbation of their isotropic states. The physical dependence of rotating turbulent shear flows on omega/S is discussed in detail along with the implications for turbulence modeling.

Speziale, Charles G.↗

Floating frame grounding system

The development of a floating frame grounding system (FFGS) for the 40- by 80-foot low speed wind tunnel facility at the NASA Ames Research Center National Full Scale Aerodynamics Complex is addresssed. When electrical faults are detected, the FFGS ensures a ground path for the fault current. In addition, the FFGS alerts the tunnel operator when a mechanical foul occurs.

Forsyth, T. J.↗

Determination of a geocentric coordinate frame for GPS measurements

Two strategies for determining the offset from the geocenter for GPS measurements are considered. In the first strategy, VLBI-determined relative positions are used to fix the frame orientation and the absolute scaling, while the geocenter offset is determined from GPS measurements. In the second strategy, the absolute scaling is determined by the adopted gravitational constant of earth and the adjusted periods of GPS orbits, with the latitude being obtained from the time signature of earth rotation in the GPS measurements. The results indicate that geocentric positioning to an accuracy of a few centimeters can be achieved with just one day of precise GPS pseudorange and carrier phase data.

Wu, S. C.↗

Hydrodynamic Stability And Frames Of Reference

Criteria of stability different in different sets of coordinates. Report discusses dependence of criteria of hydrodynamic instability upon frame of reference used to analyze motion of fluid.

Zak, Michail A.↗

A critical comparison of turbulence models for homogeneous shear flows in a rotating frame

A variety of turbulence models, including five second-order closure models and four two equation models, are tested for the problem of homogeneous turbulent shear flow in a rotating frame. The model predictions for the time evolution of the turbulent kinetic energy and dissipation rate, as well as those for the equilibrium states, are compared with the results of physical and numerical experiments. Most of the two-equation models predict the same results for all rotation rates (omega/S) in which there is an exponential time growth of the turbulent kinetic energy and dissipation rate. The second-order closures are qualitatively superior since, consistent with physical and numerical experiments, they only predict this type of unstable flow for intermediate rotation rates in the range -0.1 less than or equal to omega/S less than or equal to 1.6. For rotation rates outside this range, there is an exchange of stabilities with a solution whose kinetic energy and dissipation rate decay with time. Although the second-order closures are superior to the two-equation models, there are still problems with the quantitative accuracy of their predictions.

Speziale, Charles G.↗

Celestial reference frames - Definitions and accuracies

The paper examines the accuracies of the three most prominent celestial reference frames: stellar catalogs, lunar and planetary ephemerides, and radio source catalogs. Among other findings, it is shown that the stellar reference systems presently shows uncertainties up to nearly a tenth of an arcsec. Radio-source catalogs have internal consistencies of 0.001 arcsec or less.

Standish, E. M.↗

The celestial reference frame defined by VLBI

VLBI currently produces the most accurate positions of celestial objects. From 1979 to 1987, 114 extragalactic radio sources have been observed with dual-frequency Mark III VLBI as part of the NASA Crustal Dynamics Project and the NGS POLARIS/IRIS program. The formal statistical errors of conventional celestial coordinates are as small as 0.3 milliarcseconds. The fundamental quantity measured by VLBI is the arc length between radio sources. Thus, it is suggested that VLBI be used to establish a coordinate reference frame based solely on radio positions, and that this system not necessarily be coupled to right ascension and declination.

Ma, C.↗

Radio reference frame stability from VLBI data

Intercontinental radio interferometric measurements between NASA's Deep Space Network stations yield a catalog of positions of 106 extragalactic radio sources, uniformly distributed between -45 and +85 deg declination. Almost all of the source positions have formal uncertainties between 0.5 and 3 milliarcseconds. Estimates of three independent sets of 32 source coordinates at average epochs 1980.0, 1983.2, and 1984.5 assess the level of stability of the reference frame over a five-year period. Comparisons of the three sets of source coordinates show a number of cases of greater than 2 sigma differences, particularly between the 1984-85 and 1981-83 periods. No sources, however, show 2 sigma shifts among both pairs of epochs. Upper limits of the order of 1 mas/yr can be placed on the time rates of change of the 32 source coordinates.

Sovers, O. J.↗

Astrometry in local reference frames for deep space navigation

Future deep space missions will benefit from submilliarcsecond angular navigation accuracy (less than 25 km projected distance at Neptune). Conventional Very Long Baseline Interferometry (VLBI) measurement strategies entail observations of a radio source (RS) and spacecraft pair. To increase the 3-5 milliarcsecond accuracies currently attainable, instrumental improvements could be coupled with either of two methods: (1) use improved calibration measurements with the single RS as the spacecraft reference, or (2) use a reference frame established by a local network of RSs near the spacecraft to reduce the contribution of sky-dependent error sources. The demanding baseline vector (earth orientation) and tropospheric calibrations needed to realize submilliarcsecond accuracy with the single-source strategy would not be necessary with the multisource strategy. The two strategies are compared via a sample covariance analysis. In this analysis, the single-source method yields 1.5 milliarcseconds for the navigation accuracy, while the multisource method yields 0.5 milliarcseconds.

Treuhaft, R. N.↗

Outputs of paired Gabor filters summed across the background frame of reference predict the direction of movement

A cortical neural network that computes the visibility of shifts in the direction of movement is proposed. The network computes: (1) the magnitude of the position difference between the test and background patterns, (2) localized contrast differences at different spatial scales analyzed by computing temporal gradients of the difference and sum of the outputs of paired even- and odd-symmetric bandpass filters convolved with the input pattern, and (3) using global processes that pool the output from paired even- and odd-symmetric simple and complex cells across the spatial extent of the background frame of reference the direction a test pattern moved relative to a textured background. Evidence that magnocellular pathways are used to discriminate the direction of movement is presented. Since magnocellular pathways are used to discriminate the direction of movement, this task is not affected by small pattern changes such as jitter, short presentations, blurring, and different background contrasts that result when the veiling illumination in a scene changes.

Lawton, Teri B.↗

Scaling laws for homogeneous turbulent shear flows in a rotating frame

The scaling properties of plane homogeneous turbulent shear flows in a rotating frame are examined mathematically by a direct analysis of the Navier-Stokes equations. It is proved that two such shear flows are dynamically similar if and only if their initial dimensionless energy spectrum E star (k star, 0), initial dimensionless shear rate SK sub 0/epsilon sub 0, initial Reynolds number K squared sub 0/nu epsilon sub 0, and the ration of the rotation rate to the shear rate omega/S are identical. Consequently, if universal equilibrium states exist, at high Reynolds numbers, they will only depend on the single parameter omega/S. The commonly assumed dependence of such equilibrium states on omega/S through the Richardson number Ri = -2(omega/S)(1-2 omega/S) is proven to be inconsistent with the full Navier-Stokes equations and to constitute no more than a weak approximation. To be more specific, Richardson number similarity is shown to only rigorously apply to certain low-order truncations of the Navier-Stokes equations (i.e., to certain second-order closure models) wherein closure is achieved at the second-moment level by assuming that the higher-order moments are a small perturbation of their isotropic states. The physical dependence of rotating turbulent shear flows on omega/S is discussed in detail along with the implications for turbulence modeling.

Speziale, Charles G.↗

Time dependent three-dimensional body frame quantal wave packet treatment of the H + H2 exchange reaction on the Liu-Siegbahn-Truhlar-Horowitz (LSTH) surface

The first successful application of the three-dimensional quantum body frame wave packet approach to reactive scattering is reported for the H + H2 exchange reaction on the LSTH potential surface. The method used is based on a procedure for calculating total reaction probabilities from wave packets. It is found that converged, vibrationally resolved reactive probabilities can be calculated with a grid that is not much larger than required for the pure inelastic calculation. Tabular results are presented for several energies.

Neuhauser, Daniel↗

Data compression techniques applied to high resolution high frame rate video technology

An investigation is presented of video data compression applied to microgravity space experiments using High Resolution High Frame Rate Video Technology (HHVT). An extensive survey of methods of video data compression, described in the open literature, was conducted. The survey examines compression methods employing digital computing. The results of the survey are presented. They include a description of each method and assessment of image degradation and video data parameters. An assessment is made of present and near term future technology for implementation of video data compression in high speed imaging system. Results of the assessment are discussed and summarized. The results of a study of a baseline HHVT video system, and approaches for implementation of video data compression, are presented. Case studies of three microgravity experiments are presented and specific compression techniques and implementations are recommended.

Hartz, William G.↗

A neural network for controlling the configuration of frame structure with elastic members

A neural network for controlling the configuration of frame structure with elastic members is proposed. In the present network, the structure is modeled not by using the relative angles of the members but by using the distances between the joint locations alone. The relationship between the environment and the joints is also defined by their mutual distances. The analog neural network attains the reaching motion of the manipulator as a minimization problem of the energy constructed by the distances between the joints, the target, and the obstacles. The network can generate not only the final but also the transient configurations and the trajectory. This framework with flexibility and parallelism is very suitable for controlling the Space Telerobotic systems with many degrees of freedom.

Tsutsumi, Kazuyoshi↗

GPS inferred geocentric reference frame for satellite positioning and navigation

Accurate geocentric three-dimensional positioning is of great importance for various geodetic and oceanographic applications. While relative positioning accuracy of a few centimeters has become a reality using Very Long Baseline Interferometry (VLBI), the uncertainty in the offset of the adopted coordinate system origin from the geocenter is still believed to be of the order of one meter. Satellite Laser Ranging (SLR) is capable of determining this offset to better than 10 cm, though, because of the limited number of satellites, this requires a long arc of data. The Global Positioning System (GPS) measurements provide a powerful alternative for an accurate determination of this origin offset in relatively short period of time. Two strategies are discussed, the first utilizes the precise relative positions predetermined by VLBI, whereas the second establishes a reference frame by holding only one of the tracking sites longitude fixed. Covariance analysis studies indicate that geocentric positioning to an accuracy of a few centimeters can be achieved with just one day of precise GPS pseudorange and carrier phase data.

Malla, Rajendra P.↗

Optical variability of extragalactic objects used to tie the HIPPARCOS reference frame to an extragalactic system using Hubble space telescope observations

Observations of a set of 89 extragalactic objects (EGOs) will be made with the Hubble Space Telescope Fine Guidance Sensors and Planetary Camera in order to link the HIPPARCOS Instrumental System to an extragalactic coordinate system. Most of the sources chosen for observation contain compact radio sources and stellarlike nuclei; 65 percent are optical variables beyond a 0.2 mag limit. To ensure proper exposure times, accurate mean magnitudes are necessary. In many cases, the average magnitudes listed in the literature were not adequate. The literature was searched for all relevant photometric information for the EGOs, and photometric parameters were derived, including mean magnitude, maximum range, and timescale of variability. This paper presents the results of that search and the parameters derived. The results will allow exposure times to be estimated such that an observed magnitude different from the tabular magnitude by 0.5 mag in either direction will not degrade the astrometric centering ability on a Planetary Camera CCD frame.

Bozyan, Elizabeth P.↗

A critical comparison of turbulence models for homogeneous shear flows in a rotating frame

A variety of turbulence models, including five second-order closure models and four two equation models, are tested for the problem of homogeneous turbulent shear flow in a rotating frame. The model predictions for the time evolution of the turbulent kinetic energy and dissipation rate, as well as those for the equilibrium states, are compared with the results of physical and numerical experiments. Most of the two-equation models predict the same results for all rotation rates (omega/S) in which there is an exponential time growth of the turbulent kinetic energy and dissipation rate. The second-order closures are qualitatively superior since, consistent with physical and numerical experiments, they only predict this type of unstable flow for intermediate rotation rates in the range -0.1 less than or equal to omega/S less than or equal to 1.6. For rotation rates outside this range, there is an exchange of stabilities with a solution whose kinetic energy and dissipation rate decay with time. Although the second-order closures are superior to the two-equation models, there are still problems with the quantitative accuracy of thier predictions.

Speziale, Charles G.↗