Search NASA⌕ Search

SEARCH · Search NASA

Results for “frequency combs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Laser-free GHz stroboscopic transmission electron microscope: Components, system integration, and practical considerations for pump–probe measurements

In this work a 300 keV transmission electron microscope was modified to produce broadband pulsed beams that can be, in principle, between 40 MHz and 12 GHz, corresponding to temporal resolution in the nanosecond to picosecond range without an excitation laser. The key enabling technology is a pair of phase-matched modulating and de-modulating traveling wave metallic comb striplines (pulsers). An initial temporal resolution of 30 ps was achieved with a strobe frequency of 6.0 GHz. The placement of the pulsers, mounted immediately below the gun, allows for preservation of all optical configurations, otherwise available to the unmodified instrument, and therefore makes such a post-modified instrument for dual-use, i.e., both pulsed-beam mode (i.e., stroboscopic time-resolved) and conventional continuous waveform mode. In this article, we describe the elements inserted into the beam path, challenges encountered during integration with an in-service microscope, and early results from an electric-field-driven pump–probe experiment. We conclude with ideas for making this class of instruments broadly applicable for examining cyclical and repeatable phenomena.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High-power helicon system commissioning and conditioning progress on DIII-D

The high-power helicon, aka fast wave in the lower hybrid range of frequencies (LHRF), program has completed initial experiments at DIII-D. A 30-element comb-line traveling wave antenna successfully coupled over 0.3 MW of rf power at 476 MHz into both L-mode and ELMing H-mode plasmas for approximately 0.2 s. Here, we describe the helicon systems that enabled high-power operations, and the progress of conditioning in June 2021. Upgraded vacuum feedthroughs are described.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The spectral characteristics of rotor blade-vortex interaction noise - Experimental and mathematical results

The BVI impulsive content of a rotor acoustic signal is shown to appear in the mid-frequency range of the power spectrum, between the fifth and thirtieth harmonics of the blade passage frequency, concentrated at the harmonics of the blade passage frequency. These harmonics exhibit a humped or scalloped shape in this mid-frequency spectral region. Increased energy at the harmonics of the shaft frequency appears when the BVI impulsive content demonstrates unsteadiness and blade-to-blade differences in the time domain. A mathematical model of a generalized BVI acoustic signal and its power spectrum shows that the power spectrum is scalloped and filtered by a comb function. The spectrum amplitude is defined by the impulse amplitude and emission time. The scalloping of the spectrum is related to the emission time of the impulse itself, and the spacing of the comb function is related to the repetition time (period) of the impulse. The decay rate of the spectral humps is governed by the inverse of frequency squared. The mathematical model validates the characteristics observed in the data and verify that these characteristics are due to blade-vortex interaction activity.

Martin, Ruth M.↗

Multi-Frequency Microwaves Plasma Production for Active Profile Control of Ion Beams on a Large Bore ECR Ion Source with Permanent Magnets

A new concept on magnetic field of plasma production and confinement by using permanent magnets, i.e. cylindrically comb-shaped magnets, has been proposed to enhance efficiency of an electron cyclotron resonance (ECR) plasma for broad and dense ion beam source under the low pressure and also the low microwave power. The resonance zones corresponding to the fundamental ECR for 2.45 GHz and 11-13 GHz frequency are constructed at different positions. The profiles of the plasma parameters in the ECR ion source are different from each frequency of microwave. Large bore extractor is set at the opposite side against the microwave feeds. It is found that differences of their profiles also appear at those of ion beam profiles. We conducted to launch simultaneously multiplex frequency microwaves controlled individually, and tried to control the profiles of the plasma parameters and then those of extracted ion beam.

43 PARTICLE ACCELERATORS↗

Tracking Comb Filter Suppresses Welder Harmonics

Tracking comb filter includes charge-coupled-device delay line and phase-locked loop. Filter removes harmonics of frequency of repetition of welding-current pulses from acoustic-emission signal. Spurious signals reduced almost to fundamental limit.

Delcher, Ray C.↗

NMR Studies of Block Copolymer-Based Supramolecules in Solution

Hierarchical assemblies from block copolymer (BCP)-based supramolecules have shown immense potential as programmable materials owing to their versatility for incorporating functional molecules and provide access to arrays of hierarchical structures. However, there remains a knowledge gap on the formation of the supramolecule in solution. Here, we applied NMR techniques to investigate the solution-phase behavior of the most studied supramolecular systems, polystyrene-block-poly(4-vinylpyridine)(3-pentadecylphenol) (PS-b-P4VP(PDP) r ). The results show that the supramolecule likely adopts a coil-comb conformation, despite the small molecule's (PDP) rapid exchange between the bonded and free states. The exchange rate (>10 4 s -1 ) exceeds the NMR time scale at the frequency of interest. The supramolecules form under dilute conditions (~2 vol %) and are attributed to the enthalpic gain of the hydrogen bonding between the PDP and 4VP. As the solute concentration increases (>10 vol %), the supramolecule forms micelle-like aggregates with PDP accumulated within the comb-block's pervaded volume based on analysis of the apparent molecular weight, viscosity, and chain dynamics. Overall, this work sheds light on the long-standing question regarding the evolution of the constituents in the BCP-based supramolecule in solution and provides valuable guidance toward their solution-based processing and morphological control.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fibre laser with a subterahertz repetition rate of ultrashort pulses in the telecom range

We have investigated a new fibre laser configuration for the generation of ultrashort pulses at a repetition rate far exceeding the fundamental cavity frequency. The laser configuration includes a nonlinear amplifying mirror as an artificial saturable absorber for mode locking and a spectral comb filter for pulse separation stabilisation. Generation of trains and sequences of ultrashort pulses at a repetition rate tunable in the range 8 – 200 GHz has been demonstrated experimentally. The pulses generated by the laser have been shown to retain an ordered, equidistant structure on a nanosecond timescale. (extreme laser radiation: physics and fundamental applications)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Resonant excitation of coherent Cerenkov radiation in dielectric lined waveguides

We report the observation of coherent Cerenkov radiation in the terahertz regime emitted by a relativistic electron pulse train passing through a dielectric lined cylindrical waveguide. We describe the beam manipulations and measurements involved in repetitive pulse train creation including comb collimation and nonlinear optics corrections. With this technique, modes beyond the fundamental are selectively excited by use of the appropriate frequency train. The spectral characterization of the structure shows preferential excitation of the fundamental and of a higher longitudinal mode.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Highly stable microwave delay line

TWM /Traveling Wave Master/ comb structure serves as a highly stable microwave delay line for determining the short-term stability of the hydrogen maser frequency standards used in the deep space network. Cryogenic cooling is used to minimize signal attenuation and thermal noise.

Higa, W. H.↗

Enhanced production of electron cyclotron resonance plasma by exciting selective microwave mode on a large-bore electron cyclotron resonance ion source with permanent magnet

We are constructing a tandem type ECRIS. The first stage is large-bore with cylindrically comb-shaped magnet. We optimize the ion beam current and ion saturation current by a mobile plate tuner. They change by the position of the plate tuner for 2.45 GHz, 11–13 GHz, and multi-frequencies. The peak positions of them are close to the position where the microwave mode forms standing wave between the plate tuner and the extractor. The absorbed powers are estimated for each mode. We show a new guiding principle, which the number of efficient microwave mode should be selected to fit to that of multipole of the comb-shaped magnets. We obtained the excitation of the selective modes using new mobile plate tuner to enhance ECR efficiency.

43 PARTICLE ACCELERATORS↗

Independent gain and bandwidth control of a traveling wave maser

An X-band traveling wave maser of the folded-comb type is presented, with two figure-eight coils for gain and bandwidth control. One figure-eight coil covers the full lengths of the comb structure for bandwidth adjustment of an external magnetic field. The other coil covers a central half of the comb structure for independent gain adjustment of the external magnetic field. The half of each figure-eight coil at the turn around end of the comb structure is oriented to aid the external magnetic field, and the half of each coil at the input-output end of the comb structure is oriented to buck the external magnetic field. The maser is pumped in the push-push mode with two different frequencies.

Trowbridge, D. L.↗

Production of electron cyclotron resonance plasma by using multifrequencies microwaves and active beam profile control on a large bore electron cyclotron resonance ion source with permanent magnets

A new concept on magnetic field with all magnets on plasma production and confinement has been proposed to enhance efficiency of an electron cyclotron resonance (ECR) plasma for broad and dense ion beam source under the low pressure. The magnetic field configuration is constructed by a pair of magnets assembly, i.e., comb-shaped magnet which cylindrically surrounds the plasma chamber. The resonance zones corresponding to the fundamental ECR for 2.45 GHz and 11-13 GHz frequencies are constructed at different positions. The profiles of the plasma parameters in the ECR ion source are different from each frequency of microwave. Large bore extractor is set at the opposite side against the microwave feeds. It is found that differences of their profiles also appear at those of ion beam profiles. We conducted to launch simultaneously multiplex frequencies microwaves controlled individually, and tried to control the profiles of the plasma parameters and then those of extracted ion beam.

43 PARTICLE ACCELERATORS↗

Spectroscopy of the methane {nu}{sub 3} band with an accurate midinfrared coherent dual-comb spectrometer

We demonstrate a high-accuracy dual-comb spectrometer centered at 3.4 {mu}m. The amplitude and phase spectra of the P, Q, and partial R branches of the methane {nu}{sub 3} band are measured at 25 to 100 MHz point spacing with resolution under 10 kHz and a signal-to-noise ratio of up to 3500. A fit of the absorbance and phase spectra yields the center frequency of 132 rovibrational lines. The systematic uncertainty is estimated to be 300 kHz, which is 10{sup -3} of the Doppler width and a 10-fold improvement over Fourier transform spectroscopy. These data quantify the accuracy and resolution achievable with direct comb spectroscopy in the midinfrared.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-precision phase detection in femtosecond timing and synchronization system for TXGLS

High-precision phase detection is critical to the timing and synchronization system for particle accelerators. A live calibration signal is introduced to femtosecond-level phase detection in order to measure the relative phase jitter between a reference wave and a radio frequency (RF) signal, and compensate for the cable electrical length drift due to the thermal variation effect. Non-IQ sampling and 2-stage cascaded integrator-comb filters are integrated into the field-programmable gate array-based digital signal processing to reduce spectrum aliasing and suppress noise. Fine adjustment of hardware components has been made to ensure the isolation between different signals and the linearity over the full-range power level. Lastly, we have achieved a 6.3 fs root mean square timing jitter for a 2856 MHz RF signal in a single channel, compared to the theoretical limit of 5.1 fs for the current hardware component.

43 PARTICLE ACCELERATORS↗

Modulating surface acoustic wave generation through superconductivity

Surface acoustic waves (SAWs), with their five orders-of-magnitude slower propagation velocity, allow for considerably shorter wavelengths at the same frequency compared to electromagnetic waves. The short wavelengths allow for device miniaturization and on-chip integration. The generic design of these devices involves piezoelectric substrates with comb-like arrays of Al or Au electrodes known as interdigitated transducers (IDTs) deposited on the surface. However, Al and Au both have shortcomings at the cryogenic temperatures required for quantum applications, namely, the formation of two-level systems and the lack of superconductivity perpetuating Ohmic losses, respectively. In this work, SAWs are generated in the high-MHz to low-GHz range using niobium nitride (NbN) interdigitated transducers and Bragg reflectors. We demonstrate the fabrication of acoustic devices through photolithography and reactive ion etching. The sharp transition between superconducting and normal states and the corresponding change in SAW transmission allows for fine control of the “on” (superconducting) and “off” (normal) states of NbN, with a ΔT = 1 K separating the transmission minimum and maximum. We demonstrate a 16× difference in transmission between the “on” and “off” states of the device. The SAW transmission behavior mirrors the change in resistance of NbN at its T c . These findings open up new possibilities for the integration of NbN SAW resonators into existing quantum architectures based on NbN and a method for adjusting transmission properties independent of applied voltage.

36 MATERIALS SCIENCE↗

Direct visualization of electromagnetic wave dynamics by laser-free ultrafast electron microscopy

Integrating femtosecond lasers with electron microscopies has enabled direct imaging of transient structures and morphologies of materials in real time and space. Here, we report the development of a laser-free ultrafast electron microscopy (UEM) offering the same capability but without requiring femtosecond lasers and intricate instrumental modifications. We create picosecond electron pulses for probing dynamic events by chopping a continuous beam with a radio frequency (RF)–driven pulser with the pulse repetition rate tunable from 100 MHz to 12 GHz. As a first application, we studied gigahertz electromagnetic wave propagation dynamics in an interdigitated comb structure. We reveal, on nanometer space and picosecond time scales, the transient oscillating electromagnetic field around the tines of the combs with time-resolved polarization, amplitude, and local field enhancement. This study demonstrates the feasibility of laser-free UEM in real-space visualization of dynamics for many research fields, especially the electrodynamics in devices associated with information processing technology.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A rate-doubled 10-GHz fiducial comb generator for precision optical timing calibration

Solid-state optical fiducial timing pulse generators provide a convenient and accurate method to include timing fiducials in a streak-camera image for time-base correction. Current commercially available vertical-cavity surface-emitting lasers (VCSEL’s) emitting in the visible range can be amplitude modulated up to 5 GHz. An optically passive method is utilized to interleave a time-delayed path of the 5-GHz pulsed light with itself, producing a 10-GHz pulsed fiducial, or comb. Comb pulse rates at 0.5, 1.0 and 2.5 GHz can also be selected. The instrument presented is a self-contained and portable generator with primary use for streak-camera temporal calibration. Applications can also be extended to many other optical timing needs. The VCSEL output is fiber optic coupled at a wavelength of 680 nm (visible red) with a nearly Gaussian pulse shape. The peak power of each ~50-ps FWHM comb pulse at 5-GHz operation, or picket, is approximately 5 mW. The low phase noise of the internal microwave modulation drive source provides low pulse to pulse jitter. An external reference frequency standard can be utilized to synchronize the output to external timing equipment. A selectable internal reference frequency crystal oscillator is incorporated for stand-alone operation.

42 ENGINEERING↗

Stroboscopic ultrafast imaging using RF strip-lines in a commercial transmission electron microscope

The development of ultrafast electron microscopy (UEM), specifically stroboscopic imaging, has brought the study of structural dynamics to a new level by overcoming the spatial limitations of ultrafast spectroscopy and the temporal restrictions of traditional TEM simultaneously. Combining the concepts governing both techniques has enabled direct visualization of dynamics with spatiotemporal resolutions in the picosecond-nanometer regime. Here, in this study, we push the limits of imaging using a pulsed electron beam via RF induced transverse deflection based on the newly developed 200 keV frequency-tunable strip-line pulser. We demonstrate 0.2 nm spatial resolution at high magnifications and elucidation of Lorentz imaging using the phase-microscopy method. We also present beam coherence measurements and expand our study using the breathing modes of a silicon interdigitated comb under RF excitation which achieves improved temporal synchronization between the electron pulse-train and electric field. A new RF holder has also been developed with impedance matching to the RF signal to minimize transmission power loss to samples and its performance is compared with a conventional sample holder.

47 OTHER INSTRUMENTATION↗