Search NASA⌕ Search

SEARCH · Search NASA

Results for “grid simulator testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Extreme metrics from large ensembles: investigating the effects of ensemble size on their estimates

Abstract. We consider the problem of estimating the ensemble sizes required to characterize the forced component and the internal variability of a number of extreme metrics. While we exploit existing large ensembles, our perspective is that of a modeling center wanting to estimate a priori such sizes on the basis of an existing small ensemble (we assume the availability of only five members here). We therefore ask if such a small-size ensemble is sufficient to estimate accurately the population variance (i.e., the ensemble internal variability) and then apply a well-established formula that quantifies the expected error in the estimation of the population mean (i.e., the forced component) as a function of the sample size n, here taken to mean the ensemble size. We find that indeed we can anticipate errors in the estimation of the forced component for temperature and precipitation extremes as a function of n by plugging into the formula an estimate of the population variance derived on the basis of five members. For a range of spatial and temporal scales, forcing levels (we use simulations under Representative Concentration Pathway 8.5) and two models considered here as our proof of concept, it appears that an ensemble size of 20 or 25 members can provide estimates of the forced component for the extreme metrics considered that remain within small absolute and percentage errors. Additional members beyond 20 or 25 add only marginal precision to the estimate, and this remains true when statistical inference through extreme value analysis is used. We then ask about the ensemble size required to estimate the ensemble variance (a measure of internal variability) along the length of the simulation and – importantly – about the ensemble size required to detect significant changes in such variance along the simulation with increased external forcings. Using the F test, we find that estimates on the basis of only 5 or 10 ensemble members accurately represent the full ensemble variance even when the analysis is conducted at the grid-point scale. The detection of changes in the variance when comparing different times along the simulation, especially for the precipitation-based metrics, requires larger sizes but not larger than 15 or 20 members. While we recognize that there will always exist applications and metric definitions requiring larger statistical power and therefore ensemble sizes, our results suggest that for a wide range of analysis targets and scales an effective estimate of both forced component and internal variability can be achieved with sizes below 30 members. This invites consideration of the possibility of exploring additional sources of uncertainty, such as physics parameter settings, when designing ensemble simulations.

54 ENVIRONMENTAL SCIENCES↗

Implementing a Hardware Testbed Using 3-Level ANPC Software Defined Inverters for Fault Analysis of a Transmission Network

In this paper, we propose the implementation of a hardware testbed using 3-level active neutral point clamped (ANPC) software-defined inverters for fault analysis. A test case transmission network equipped with two grid forming (GFM) inverters and four resistive loads is considered in this research. Firstly, grid forming control laws including PI feedback control and droop control are implemented to operate the inverters in parallel. Then, we implement a fault ride-through (FRT) logic and perform a simulation of the test system by applying a three-phase fault. Simulation results show the effectiveness of the fault recovery algorithm upon clearance of the fault. Finally, a 3-level ANPC software-defined inverter is programmed with required control laws and characterized through various lab experiments.

3-level ANPC inverter↗

A novel islanding detection technique for grid connected photovoltaic system

Islanding detection is the major issue in Grid Connected Photovoltaic (PV) System and still it remains a challenge for researchers to interconnect the PV system with the Grid. The algorithms which are listed in the literature are failed to identify the Islanding phenomena for the several source configuration. In this paper a novel islanding detection technique is presented to reduce the non-detection zone (NDZ) at the point of common coupling (PCC) and it can be widely used for various renewable energy system configurations. The simulations have been carried out in Matlab/Simulink for several test conditions. The simulations results are presented to confirm the effectiveness of the proposed method.

14 SOLAR ENERGY↗

Operation and Control of Electric Vehicle Charger with Enhanced Dynamic Performance Under Non-Ideal Grid Voltage Condition

This paper presents a three-phase electric vehicle charger connected to the grid, featuring multiple boost converters on the DC side, specifically designed to ensure smooth, oscillation-free power transfer during unsymmetrical voltage sags. Precise control mechanisms are implemented on the boost converter side to regulate both voltage and current on the electric vehicle side, thereby maintaining optimal charging conditions. The control architecture for both the grid-connected and boost converter components is based on the Lyapunov energy function, which is employed to achieve superior dynamic performance and stability. The system's robustness and reliability are demonstrated through its ability to maintain stable operation and efficient power transfer despite fluctuations in grid conditions. Furthermore, the implementation of Lyapunov-based control ensures rapid response and minimal energy loss, enhancing the overall efficiency of the system. To validate the effectiveness of this approach, a comprehensive model of the system was developed and tested using MATLAB/Simulink, with detailed computer simulations conducted across various significant case studies.

DC-DC boost converter↗

Network Reduction Algorithm for Developing Distribution Feeders for Real-Time Simulators

As advanced grid-support functions (AGF) become more widely used in grid-connected photovoltaic (PV) inverters, utilities are increasingly interested in their impacts when implemented in the field. These effects can be understood by modeling feeders in real-time simulators and test PV inverters using power hardware-in-the-loop (PHIL) techniques. This paper presents a novel feeder model reduction algorithm using a ruin & reconstruct methodology that enables large feeders to be solved and operated on real-time computing platforms. Two Hawaiian Electric feeder models in Synergi Electric's load flow software were converted to reduced order models in OpenDSS, and subsequently implemented in the OPAL-RT real-time digital testing platform. Smart PV inverters were added to the realtime model with AGF responses modeled after characterizing commercially available hardware inverters. Finally, hardware inverters were tested in conjunction with the real-time model using PHIL techniques so that the effects of AGFs on the feeders could be analyzed.

14 SOLAR ENERGY↗

Electric Water Heaters for Transactive Systems: Model Evaluations and Performance Quantification

Electric water heaters (EWHs) are opportune appliances for implementing demand-side control. EWH models serve as a fundamental step toward accurately estimating EWH flexibility potential and designing proper control strategies. Existing studies have adapted numerous modeling approaches in evaluating the potential of EWHs for a variety of grid applications. This paper presents an analytical study that evaluates the performance of state-of-art EWH models in terms of accuracy and computational complexity for adaptation in evaluation studies for the transactive system. The work proposes a transactive control strategy that optimally utilizes the thermal inertia of EWHs for providing grid services. Here, the performance of the control strategy and the impact of modeling accuracy is evaluated for device-level and feeder-level use cases using the IEEE 123 node test distribution system appropriately populated with EWHs. The simulation results illustrate the effectiveness of the control strategy in reducing the feeder demand during peak period by 13% and also quantities the impact of using simplified modeling approaches for determining the potential of EWHs for providing grid services.

42 ENGINEERING↗

Integrating High Penetrations of PV into Southern California

California regulators recently approved a plan proposed by Southern California Edison (SCE) to install 500 MW of distributed photovoltaic (PV) energy in its utility service territory over the next 5 years. The installations will include 250 MW of utility-owned solar and 250 MW of independently owned solar. SCE expects that the majority of these systems will be commercial-scale rooftop PV systems connected at various points in the distribution system. Each of the SCE rooftop PV systems will typically have a rating of 1-3 MW. To understand the impact of high-penetration PV on the distribution grid, the National Renewable Energy Laboratory (NREL) and SCE brought together a team of experts in resource assessment, distribution modeling, and planning to help analyze the impacts of adding high penetration of PV into the distribution system. Through modeling and simulation, laboratory testing, and field demonstrations, the team will address the issues identified in the analysis by fully examining the challenges, developing solutions, and transitioning those solutions to the field for large-scale deployment. This paper gives an update on the project and discusses technical results of integrating a large number of distributed PV systems into the grid.

14 SOLAR ENERGY↗

Control and Real-Time Simulation of Microgrids with EV Fast-Charging and Grid-Forming Resources

Fast charging stations (FCSs) for electric vehicles (EVs) can behave as constant power loads, which is problematic for the operation of grid-forming (GFM) inverter-based resources (IBRs). To tackle this problem, this paper proposes a control suite that makes FCSs responsive to ac voltage and frequency disturbances. To test the performance of the FCS controls, the paper also sets forth theory to compensate for time-delays appearing in the real-time simulation of microgrid models divided into several central processing units (CPUs). Furthermore, these contributions are showcased via multi-CPU real-time simulations of a faulted microgrid having EV FCSs and GFM IBRs powered by photovoltaic solar arrays as well as power hardware-in-the-loop experiments. These contributions are significant to address NERC recommendations and IEEE standards.

14 SOLAR ENERGY↗

A Review of Quantum Computing Technologies in Power System Optimization

As modern power grids increasingly integrate variable renewable generation, distributed energy resources, and energy storage systems, classical optimization techniques are facing unprecedented challenges. This review examines the emerging application of quantum computing to overcome these challenges in power system optimization, including optimal power flow (OPF), unit commitment (UC), economic dispatch (ED), and intelligent switching and topology optimization (IS-TO). Recent research has introduced various quantum methodologies—such as gate-based, annealing-based, variational algorithms, and quantum-inspired algorithms—to address the combinatorial complexity inherent in grid reconfiguration and energy management. The review summaries the quantum algorithms, quantum devices and the power system test cases, highlighting hybrid quantum–classical strategies that leverage the complementary strengths of both paradigms. Some quantum advantages have been observed, including theoretical speedup, accurate simulation results, scalable qubit usage, efficient QUBO mapping. In particular, the review emphasizes the importance of integrating quantum optimization techniques with classical control frameworks, these hybrid approaches demonstrate the potential to improve real-time grid management and operational reliability. A significant portion of the analysis is devoted to the practical limitations of current quantum devices. Present-day quantum hardware, operating in the noisy intermediate-scale quantum (NISQ) era, remains highly sensitive to noise and limited in qubit connectivity, which constrains the scale and accuracy of implemented algorithms. The review delves into specific challenges such as the need for qubit-efficient encoding techniques and error mitigation strategies that are critical for handling real-world grid optimization problems. In addition, the work draws attention to the performance discrepancies between theoretical quantum speedups and experimental validations, underscoring the importance of rigorous benchmark studies using representative power grid test cases. In summary, this review highlights both the promise and limitations of quantum computing for power system optimization. It provides a comprehensive overview of the state-of-the-art technologies, categorizes recent advancements in algorithm design, and discusses practical considerations for implementation, and serves as an informative resource on current research. Future research directions include developing robust hybrid frameworks, advancing qubit-efficient formulations, and scaling up experimental demonstrations to confirm the theoretical advantages of quantum methods in large-scale power system operations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Test-Based Modeling of Photovoltaic Inverter Impact on Distribution Systems

Distributed PV has important effects on overcurrent, overvoltage and islanding protection. These effects are more difficult to analyze because the faulted behavior of PV inverters is less well understood than for rotating machines. Full transient models of the inverter can be accurate, but that approach requires inverter design details and simulation software that doesn’t easily interoperate with utility protection system software. Further, anomalous model behaviors often emerge at different grid conditions, and these are difficult to fix in a proprietary model. Testing provides another approach to characterize inverters, validate models or answer questions of application. This earlier work found major impacts from the inverter design, firmware, operating point and balance-of-system components. Our objective is to characterize PV inverters from black-box testing, leading to standard test reports that could provide parameter sets for widely-implemented models in software tools. The tool vendors can then develop standard inverter models, as they did for rotating machines and exciters. Besides fully detailed transient models, inverters can be represented with steady-state current sources, dynamically controlled current sources or non-linear frequency-dependent black boxes. Type-test data could support the last three kinds of model. Short circuit and sag tests would encompass the basic fault types, reporting the maximum transient and rms currents over all power levels and points-on-wave within four time ranges : 1) 0 to 1 cycles, for close and latch consideration 2) 1 to 4 cycles, for equipment withstand 3) 4 to 30 cycles, for interrupt ratings 4) 30 cycles and beyond, for backup protection analysis Open circuit tests would vary output power and power factor, and report the maximum rms voltage from 1 to 10 cycles after the event. Without models, the type-test data could also provide upper limits on the expected overvoltages and overcurrents.

Wieserman, Laura M.↗

An Investigation into Solution Verification for CFD-DEM

This report presents the study of the convergence behavior of the computational fluid dynamicsdiscrete element method (CFD-DEM) method, specifically National Energy Technology Laboratory’s (NETL) open source MFiX code (MFiX-DEM) with a diffusion based particle-tocontinuum filtering scheme. In particular, this study focused on determining if the numerical method had a solution in the high-resolution limit where the grid size is smaller than the particle size. To address this uncertainty, fixed particle beds of two primary configurations were studied: i) fictitious beds where the particles are seeded with a random particle generator, and ii) instantaneous snapshots from a transient simulation of an experimentally relevant problem. Both problems considered a uniform inlet boundary and a pressure outflow. The CFD grid was refined from a few particle diameters down to 1/6 th of a particle diameter. The pressure drop between two vertical elevations, averaged across the bed cross-section was considered as the system response quantity of interest. A least-squares regression method was used to extrapolate the grid-dependent results to an approximate “grid-free” solution in the limit of infinite resolution. The results show that the diffusion based scheme does yield a converging solution. However, the convergence is more complicated than encountered in simpler, single-phase flow problems showing strong oscillations and, at times, oscillations superimposed on top of globally non-monotonic behavior. The challenging convergence behavior highlights the importance of using at least four grid resolutions in solution verification problems so that (over-determined) regression-based extrapolation methods may be applied to approximate the grid-free solution. The grid-free solution is very important in solution verification and VVUQ exercise in general as the difference between it and the reference solution largely determines the numerical uncertainty. By testing different randomized particle configurations of the same general problem (for the fictitious case) or different instances of freezing a transient simulation, the numerical uncertainties appeared to be on the same order of magnitude as ensemble or time averaging uncertainties. By testing different drag laws, almost all cases studied show that model form uncertainty in this one, very important closure relation was larger than the numerical uncertainty, at least with a reasonable CFD grid, roughly five particle diameters. In this study, the diffusion width (filtering length scale) was mostly set at a constant of six particle diameters. A few exploratory tests were performed to show that similar convergence behavior was observed for diffusion widths greater than approximately two particle diameters. However, this subject was not investigated in great detail because determining an appropriate filter size is really a validation question which must be determined by comparison to experimental or highly accurate numerical data. Future studies are being considered targeting solution verification of transient simulations as well as validation of the filter size with direct numerical simulation data.

97 MATHEMATICS AND COMPUTING↗

Numerical prediction of interfacial instabilities: Sharp interface method (SIM)

We introduce a sharp interface method (SIM) for the direct numerical simulation of unstable fluid-fluid interfaces. The method is based on the level set approach and the structured adaptive mesh refinement technology, endowed with a corridor of irregular, cut-cell grids that resolve the interfacial region to third-order spatial accuracy. Key in that regard are avoidance of numerical mixing, and a least-squares interpolation method that is supported by irregular datasets distinctly on each side of the interface. Results on test problems show our method to be free of the spurious current problem of the continuous surface force method and to converge, on grid refinement, at near-theoretical rates. Simulations of unstable Rayleigh-Taylor and viscous Kelvin-Helmholtz flows are found to converge at near-theoretical rates to the exact results over a wide range of conditions. Further, we show predictions of neutral-stability maps of the viscous Kelvin-Helmholtz flows (Yih instability), as well as self-selection of the most unstable wave-number in multimode simulations of Rayleigh-Taylor instability. All these results were obtained with a simple seeding of random infinitesimal disturbances of interface-shape, as opposed to seeding by a complete eigenmode. For other than elementary flows the latter would normally not be available, and extremely difficult to obtain if at all. Sample comparisons with our code adapted to mimic typical diffuse interface treatments were not satisfactory for shear-dominated flows. On the other hand the sharp dynamics of our method would appear to be compatible and possibly advantageous to any interfacial flow algorithm in which the interface is represented as a discrete Heaviside function.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Modelin the Transport and Chemical Evolution of Onshore and Offshore Emissions and Their Impact on Local and Regional Air Quality Using a Variable-Grid-Resolution Air Quality Model

The overall objective of this research project was to develop an innovative modeling technique to adequately model the offshore/onshore transport of pollutants. The variable-grid modeling approach that was developed alleviates many of the shortcomings of the traditionally used nested regular-grid modeling approach, in particular related to biases near boundaries and the excessive computational requirements when using nested grids. The Gulf of Mexico region contiguous to the Houston-Galveston area and southern Louisiana was chosen as a test bed for the variable-grid modeling approach. In addition to the onshore high pollution emissions from various sources in those areas, emissions from on-shore and off-shore oil and gas exploration and production are additional sources of air pollution. We identified case studies for which to perform meteorological and air quality model simulations. Our approach included developing and evaluating the meteorological, emissions, and chemistry-transport modeling components for the variable-grid applications, with special focus on the geographic areas where the finest grid resolution was used. We evaluated the performance of two atmospheric boundary layer (ABL) schemes, and identified the best-performing scheme for simulating mesoscale circulations for different grid resolutions. Use of a newly developed surface data assimilation scheme resulted in improved meteorological model simulations. We also successfully ingested satellite-derived sea surface temperatures (SSTs) into the meteorological model simulations, leading to further improvements in simulated wind, temperature, and moisture fields. These improved meteorological fields were important for variable-grid simulations, especially related to capturing the land-sea breeze circulations that are critical for modeling offshore/onshore transport of pollutants in the Gulf region. We developed SMOKE-VGR, the variable-grid version of the SMOKE emissions processing model, and tested and evaluated this new system. We completed the development of our variable-grid-resolution air quality model (MAQSIP-VGR) and performed various diagnostic tests related to an enhanced cloud parameterization scheme. We also developed an important tool for variable-grid graphics using Google Earth. We ran the MAQSIP-VGR for the Houston-Galveston and southern Louisiana domains for an August 23 to September 2, 2002, episode. Results of the modeling simulations highlighted the usefulness of the variable-grid modeling approach when simulating complex terrain processes related to land and sea close to an urban area. Our results showed that realistic SST patterns based on remote sensing are critical to capturing the land-sea breeze, in particular the inland intrusion of the reversed mesoscale circulation that is critical for simulating air pollution over urban areas near coastal regions. Besides capturing the correct horizontal gradient between land and sea surface temperatures, it is important to use an adequate ABL scheme in order to quantify correctly the vertical profiles of various parameters. The ABL scheme should capture the dynamics of the marine boundary layer, which is not often considered in a typical simulation over land. Our results further showed the effect of using satellite-derived SSTs on the horizontal and vertical extent of the modeled pollution pattern, and the increase in hourly ozone concentrations associated with changes in ABL characteristics resulting from the enhanced mesoscale circulation in the lower troposphere.

54 ENVIRONMENTAL SCIENCES↗

Design, installation, commissioning and operation of a beamlet monitor in the negative ion beam test stand at NIFS

In the framework of the accompanying activity for the development of the two neutral beam injectors for the ITER fusion experiment, an instrumented beam calorimeter is being designed at Consorzio RFX, to be used in the SPIDER test facility (particle energy 100keV; beam current 50A), with the aim of testing beam characteristics and to verify the source proper operation. The main components of the instrumented calorimeter are one-directional carbon-fibre-carbon composite tiles. Some prototype tiles have been used as a small-scale version of the entire calorimeter in the test stand of the neutral beam injectors of the LHD experiment, with the aim of characterising the beam features in various operating conditions. The extraction system of the NIFS test stand source was modified, by applying a mask to the first gridded electrode, in order to isolate only a subset of the beamlets, arranged in two 3×5 matrices, resembling the beamlet groups of the ITER beam sources. The present contribution gives a description of the design of the diagnostic system, including the numerical simulations of the expected thermal pattern. Moreover the dedicated thermocouple measurement system is presented. The beamlet monitor was successfully used for a full experimental campaign, during which the main parameters of the source, mainly the arc power and the grid voltages, were varied. This contribution describes the methods of fitting and data analysis applied to the infrared images of the camera to recover the beamlet optics characteristics, in order to quantify the response of the system to different operational conditions. Some results concerning the beamlet features are presented as a function of the source parameters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Sequential Model Predictive and Deep Reinforcement Learning-Based Controller for Distribution System Outage Mitigation under Hurricane Events

This paper proposes a proactive outage mitigation framework for power distribution networks to withstand hurricane-induced disruptions. It leverages Model Predictive Control (MPC) to identify safe lines for proactive switching during hurricanes, minimizing the risk of cascading failures and voltage violations. The switching strategies optimized by MPC are sequentially integrated with a Deep Reinforcement Learning agent using the Advantage Actor-Critic algorithm, enabling dynamic line switching to maximize connected buses and minimize voltage violations in real time. Using a probabilistic hurricane model, the framework predicts line failures and adapts to varying conditions to enhance grid resilience. Simulations on the IEEE 123-bus system demonstrate its effectiveness in maintaining high connectivity and minimizing disruptions. Real-time testing with an RTDS confirms the practicality and reliability of the proposed approach.

Selim, Alaa [University of Connecticut]↗

Energy Systems Integration: NREL + Advanced Energy (Fact Sheet)

This fact sheet describes the collaboration between NREL and Advanced Energy Industries at the ESIF to test its advanced photovoltaic inverter technology with the ESIF's power hardware-in-the-loop system and megawatt-scale grid simulators.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Transient Stability-Enhancing Method for Grid-Forming Inverters Under Current Limiting

The primary controller of a grid-forming (GFM) inverter governs the internal reference voltage and angle, which enables the inverter to naturally synchronize and share power with the connected grid; however, during disturbances on the grid caused by, e.g., line faults, overloading, or frequency and phase shifts, a GFM inverter can be pushed into a current-limited operation to protect the device against thermal damage. This can lead to a windup of the internal reference frequency generated by the primary controller and cause a total loss of synchronism with the grid. Here, to make the primary controller of GFM inverters more robust against transient instability, this paper proposes a method that manipulates the reference signals governed by the primary controller by introducing the concept of fictitious power. The fictitious power counteracts the integrator windup in the primary controller, which enables the current-limited inverter to conceive a stable operating point. This method is benchmarked against five state-of-the-art GFM inverter stabilization methods to evaluate its stability-enhancing performance. Full-order electromagnetic-transient simulations and experimental results of a hardware inverter test setup validate the benefits of the method to improve the transient stability of GFM inverters in the face of grid disturbances.

24 POWER TRANSMISSION AND DISTRIBUTION↗