Search NASA⌕ Search

SEARCH · Search NASA

Results for “heat exchanger”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Advanced absorber heat integration via heat exchange packings

A rate-based model of an absorption column was developed and used to analyze several intercooling strategies utilizing “heat exchange packings.” These packings are capable of removing heat from the column and transferring it to a cooling fluid within the packing. For absorption of CO 2 into aqueous monoethanolamine under industrial conditions, intercooling via heat exchange packings placed along 10–20% of the column could reduce the column height by ~15%. The height of these columns was close to the minimum theoretical value, calculated by numerically optimizing the temperature profile. Effective intercooling could also be achieved by using the cool, rich solvent as the cooling fluid. This reduces the cooling load and facilitates recovery of waste heat. Heat exchange packings could also be used to redistribute heat within the column, reducing the column height with no net cooling load. However, this approach requires larger heat transfer coefficients than have been experimentally observed.

20 FOSSIL-FUELED POWER PLANTS↗

Material Studies Related to the Use of NaK Heat Exchangers Coupled to Stirling Heater Heads

NASA has been supporting design studies and technology development that could provide power to an outpost on the Moon, Mars, or an asteroid. Technology development efforts have included fabrication and evaluation of components used in a Stirling engine power conversion system. Destructive material evaluation was performed on a NaK shell heat exchanger that was developed by the NASA Glenn Research Center (GRC) and integrated with a commercial 1 kWe Stirling convertor from Sunpower Incorporated. The NaK Stirling test demonstrated Stirling convertor electrical power generation using a pumped liquid metal heat source under thermal conditions that represent the heat exchanger liquid metal loop in a Fission Power Systems (FPS) reactor. The convertors were operated for a total test time of 66 hr at a maximum temperature of 823 K. After the test was completed and NaK removed, the heat exchanger assembly was sectioned to evaluate any material interactions with the flowing liquid metal. Several dissimilar-metal braze joint options, crucial for the heat exchanger transfer path, were also investigated. A comprehensive investigation was completed and lessons learned for future heat exchanger development efforts are discussed.

Locci, Ivan E.↗

Pressure drop and heat transfer characteristics of nitrate salt and supercritical CO 2 in a diffusion-bonded heat exchanger

A lab-scale 316/L stainless steel diffusion-bonded heat exchanger was examined within a coupled high-temperature test facility consisting of an atmospheric-pressure nitrate salt loop and a supercritical carbon dioxide (sCO 2 ) loop operating between 10 and 16 MPa. Pressure loss measurements collected for flow rates up to 0.55 kg/s of Solar Salt and up to 0.6 kg/s of carbon dioxide were used to generate friction factor correlations for the respective circular and semicircular zig-zag flow passages. Heat transfer measurements were also performed over a wide range of conditions to produce Nusselt correlations for the CO 2 and nitrate salt geometries. The Nusselt number is deduced from a heat transfer resistance network and overall conductance measurements collected across the operating envelope of the coupled sCO 2 – nitrate salt test facility. The CO 2 side correlation showed excellent agreement with existing correlations in the literature. Further, the salt side, having nearly circular channels with a different zig-zag angle and hydraulic diameter, yielded a new correlation applicable to the laminar flow regime. To examine the similitude of the friction correlations, pressure drop testing with water was performed on both sides of the component as well. Finally, results from non-destructive examination are discussed to provide insights regarding inspection methods and draining performance of high-temperature liquids in compact heat exchangers.

36 MATERIALS SCIENCE↗

Study of transient behavior of finned coil heat exchangers

The status of research on the transient behavior of finned coil cross-flow heat exchangers using single phase fluids is reviewed. Applications with available analytical or numerical solutions are discussed. Investigation of water-to-air type cross-flow finned tube heat exchangers is examined through the use of simplified governing equations and an up-wind finite difference scheme. The degenerate case of zero air-side capacitance rate is compared with available exact solution. Generalization of the numerical model is discussed for application to multi-row multi-circuit heat exchangers.

Rooke, S. P.↗

Development of a silicon carbide ceramic based counter-flow heat exchanger by binder jetting and liquid silicon infiltration for concentrating solar power

A silicon carbide ceramic counter-flow heat exchanger with integrated headers was printed by binder jetting additive manufacturing process. Multiple phenolic binder infiltration cycles (3 or 5) followed by pyrolysis were conducted to increase the net carbon content of the printed SiC specimens. Subsequently, to attain full densification, silicon melt infiltration was used. The microstructure and mechanical properties were comprehensively characterized on the densified material. The chemical compositions and visual distribution of the various regions in the specimens were determined via scanning electron microscopy, while X-ray diffraction and synchrotron µ-computed tomography were used to provide a quantitative assessment of the volume fractions of the identified phase regions. Microhardness measurements showed dependence on the local microstructure. The fracture strength of the material was correlated with the specimen density and agreed with the reported values in the literature. High-temperature exposure at 750 °C for up to 200h did not degrade the strength for the specimens with three phenolic-binder infiltrations; however, the strengths degraded for ones with five phenolic-binder infiltrations. The associated fracture toughnesses of the specimens were ~3.4 MPam 1/2 at room temperature and 750°C, and the thermal conductivities varied from >150 W/mK at room temperature to ~45 W/mK at 750°C. Hence, this study validated the use of the binder-jetting printed SiC ceramic materials for high-temperature heat exchanges. Lastly, we also present in this work the first successful fabrication of a binder-jetting printed one-piece dense SiC ceramic heat exchanger body with unblocked channels that can be used for the flow of heat transfer fluids.

36 MATERIALS SCIENCE↗

Criteria for scaling heat exchangers to miniature size

The purpose of this work is to highlight the particular aspects of miniature heat exchangers performance and to determine an appropriate design approach. A thermodynamic analysis is performed to express the generated entropy as a function of material and geometric characteristics of the heat exchangers. This expression is then used to size miniature heat exchangers.

Rudolfvonrohr, P. B.↗

Ground heat exchanger design tool with rowwise placement of boreholes

Simulation-based design tools have been used since the late 1980s for designing ground heat exchangers (GHE) used with ground source heat pump (GSHP) systems. The ground heat exchanger simulations used in these tools rely on thermal response functions known as g-functions. Because of the significant computational burden in computing g-functions for even a single configuration, the design tools have relied on libraries of pre-computed g-functions. These g-functions were available for standard configuration shapes, such as lines, rectangles, open rectangles, L-shapes, and U-shapes. Standard shapes are often sub-optimal. For any building on a site, the available land may preclude use of a standard shape. For large GSHP systems with significantly imbalanced annual heat rejection and extraction loads, large rectangular fields may experience significant heat build-up (or heat draw-down) in the interior of the field. This paper describes a new ground heat exchanger design tool capable of automatically selecting and sizing both standard and irregular configurations. The focus of this paper is a method for creating, selecting and sizing irregular configurations where the available land area and "no-go" zones are described as irregular polygons.

Spitler, Jeffery↗

Analysis of capacitive heat exchangers, part 2

The performance of a simple capacitive heat exchanger was analyzed. The shooting method for solving the governing equations is presented. Simplified linear and nonlinear models are analyzed using this method and it is shown that capacitive heat exchangers are more efficient than conventional ones.

Schonfeld, D.↗

All-metal, compact heat exchanger for space cryocoolers

This report describes the development of a high performance, all metal compact heat exchanger. The device is designed for use in a reverse Brayton cryogenic cooler which provides five watts of refrigeration at 70 K. The heat exchanger consists of a stainless steel tube concentrically assembled within a second stainless steel tube. Approximately 300 pairs of slotted copper disks and matching annular slotted copper plates are positioned along the centerline axis of the concentric tubes. Each of the disks and plates has approximately 1200 precise slots machined by means of a special electric discharge process. Positioning of the disk and plate pairs is accomplished by means of dimples in the surface of the tubes. Mechanical and thermal connections between the tubes and plate/disk pairs are made by solder joints. The heat exchanger assembly is 9 cm in diameter by 50 cm in length and has a mass of 10 kg. The predicted thermal effectiveness is greater than 0.985 at design conditions. Pressure loss at design conditions is less than 5 kPa in both fluid passages. Tests were performed on a subassembly of plates integrally soldered to two end headers. The measured thermal effectiveness of the test article exceeded predicted levels. Pressure losses were negligibly higher than predictions.

Swift, Walter L.↗

A Practical Analysis Framework for Assessment of Printed Circuit Heat Exchangers in High-Temperature Nuclear Service

Abstract Printed circuit heat exchangers (PCHEs) have high thermal efficiency because of the numerous minuscule channels. These minuscule channels result in a high thermal exchange area per unit volume, making PCHE a top contender for an intermediate heat exchanger (IHX) in high-temperature reactors. Thousands of minuscule channels make finite element analysis of the PCHE computationally infeasible. A two-dimensional analysis is usually performed for the PCHE core, which cannot simulate the local channel level responses reasonably because of the absence of global constraint influence. At present, there is no analysis technique available in the ASME Code or literature that is computationally efficient and suitable for engineers to estimate PCHE local responses. A novel but practical two-step analysis framework is proposed for performing PCHE analysis. In the first step, the channeled core is replaced by orthotropic solids with similar stiffness to simulate the global thermomechanical elastic responses of the PCHE. In the second step, local submodel analysis with detailed channel geometry and loading is performed using the elastic-perfectly plastic (EPP) material model. The proposed two-step analysis technique provides a unique capability to estimate the channel corner responses to be used for PCHE performance assessment. This study first developed a methodology for calculating the elastic orthotropic properties of the PCHE core. Next, the two-step analysis is performed for a realistic size PCHE core, and different issues observed in the results are scrutinized and resolved. Finally, a practical finite element analysis framework for PCHEs in high-temperature nuclear service is recommended.

Engineering↗

Experimentation on Finned-Tube Microchannel Heat Exchanger Incorporating Phase Change Material and R-410A

Integrating latent heat thermal energy storage, particularly phase change materials (PCM), in building heating, ventilation, air conditioning, and refrigeration (HVAC&R) systems, offers substantial benefits for peak load shifting and energy efficiency. While numerous studies explore PCM-embedded heat exchangers (PCM-HX) using single-phase heat transfer fluids, there needs to be more investigation regarding PCM-HX utilizing two-phase refrigerant flow. This gap is even more pronounced for microchannel heat exchanger (MCHX) configurations. In this study, an MCHX-based PCM-HX was built and tested to analyze and evaluate the performance of a PCM-HX operating with a two-phase refrigerant as the working fluid. A commercially available MCHX condenser unit was embedded with 2.6 kg of RT35 PCM and tested using R-410A as the working fluid, using an in-house test loop to control the refrigerant inlet conditions precisely. Thin and minimally invasive T-type thermocouples traced the temperature evolution along MCHX channels and tube banks. Additional larger T-type thermocouple probes at the refrigerant inlet and outlet measured the average power of the PCM-HX during condensing tests, ranging from 0.7 kW to 1.6 kW based on mass flow rates varying from 3.5 g/s to 8 g/s. This experimental study on MCHX-based PCM-HX with a two-phase refrigerant has the potential to offer practical design guidelines for the direct integration of PCM-TES in HVAC&R systems without the use of a secondary loop, while caution is advised to avoid a substantial increase in the refrigerant charge amount.

42 ENGINEERING↗

Voxel Based Three-Dimensional Topology Optimization of Heat Exchanger Fins

Increasing interest in novel aircraft propulsion systems and potential for unwanted heat generation, or capture and reuse of waste heat, may require increasingly lightweight and high performing heat exchangers. Advances in manufacturing technologies have shown potential to create complex designs, but design tools need more flexibility. This study utilizes genetic algorithm-driven topology optimization to develop high performance heat exchanger fins for critical applications such as aerospace. The solid domain is generated using voxel representation where a voxel value of 1 indicates the solid domain and a voxel value of 0 refers to the fluid domain. The use of voxel representation somewhat matches the digitization of a model that is required to fabricate using additive manufacturing, and also allows for a highly unconstrained geometry. To test the topology optimization approach, a three-dimensional(3D)baseline offset strip fin geometry in steady laminar flow(Reynolds number = 215)with conjugate heat transfer(simultaneous solution of solid and fluid temperature fields)is optimized. New designs are generated using the genetic algorithm (GA) and sent to evaluation by the CFD software OpenFOAM; then the GA sorts and selects the reproduction pool for the following generation. This process is repeated for 60 generations. The study also investigates the effect off in material on the performance of the GA and the resulting designs. The results show that the optimal designs have overall performance improvement of 18% relative to the baseline. Additionally, a fin constructed of a lower conductivity material (such as an Inconel super alloy that might be necessary for waste heat recovery applications)results in lower overall performance improvement (11%)and optimal designs with higher pressure drop relative to their baseline, and relative to optimal designs produced using higher conductivity materials.

3D Optimization↗

Heat transfer in thin, compact heat exchangers with circular, rectangular, or pin-fin flow passages

Heat transfer and pressure drop have been measured of three thin, compact heat exchangers in helium gas at 3.5 MPa and higher, with Reynolds numbers of 450 to 36,000. The flow geometries for the three heat exchanger specimens were: circular tube, rectangular channel, and staggered pin fin with tapered pins. The specimens were heated radiatively at heat fluxes up to 77 W/sq cm. Correlations were developed for the isothermal friction factor as a function of Reynolds number, and for the Nusselt number as a function of Reynolds number and the ratio of wall temperature to fluid temperature. The specimen with the pin fin internal geometry had significantly better heat transfer than the other specimens, but it also had higher pressure drop. For certain conditions of helium flow and heating, the temperature more than doubled from the inlet to the outlet of the specimens, producing large changes in gas velocity, density, viscosity, and thermal conductivity. These changes in properties did not affect the correlations for friction factor and Nusselt number in turbulent flow.

Olson, D. A.↗

Heat-Exchanger Method of Crystal Growth

Large crystals of silicon are grown from melt, in either vacuum or pressurized atmosphere, without moving crucible, furnace, or anything else. Seed crystal is mounted on helium-cooled heat exchanger, which prevents seed from melting when furnace melts rest of silicon material in crucible; heat exchanger draws off heat from melt so that a solid ingot grows outward from seed in a regular crystal structure. Bottom of crucible is insulated so that heat exchanger cools only seed.

Khattak, C. P.↗

Al-Ce Alloy-Based Compact Heat Exchanger for Refrigerant Charge Reduction and Unprecedented Durability (CRADA NFE-21-08888 Final Report)

Oak Ridge National Laboratory and Eck Industries produced and characterized durable and corrosion resistant Al-Ce-Mg alloy-based heat exchanger. Eck Industries successfully casted Al-Ce-Mg heat exchanger. ORNL characterized reaction bonding between Al-2Ce-6Mg alloy and stainless-steel tube in a heat exchanger header. Metallurgical bonds were achieved between stainless steel tubes and Al-Ce-Mg alloy cast headers. ORNL performed corrosion testing on Al-Ce-Mg alloy/stainless steel tube reactive bond interface. In most cases no significant changes to the reactive bond morphology or compositional distribution were observed in the samples after exposure to acid for 267h acid.

36 MATERIALS SCIENCE↗

Enhancing particle-to-sCO2 heat exchanger effectiveness through novel high-porosity metallic foams

In this project, a novel concept of Octet-shape based lattice frame material was developed for deployment in particle-to-sCO2 heat exchangers for CSP application. A comprehensive experimental and numerical program was performed to investigate and characterize the thermal and flow transport behavior in high porosity lattice frame material. The thermal properties include effective thermal conductivity and interstitial heat transfer coefficient and flow properties including permeability and inertial coefficient. Above quantities were determined for both air flow and heated particle flow through the porous channels which were representative of the hot channel in a typical counter flow heat exchanger. The cold side of the heat exchanger feature minichannels which are known to be very efficient in thermal transport. The goal of this project was to enhance the overall heat transfer coefficient (Up) on the hot side by introducing Octet-shape based lattice frame material through enhancement in effective thermal conductivity of the channel and through enhancement in the interstitial heat transfer coefficient.

14 SOLAR ENERGY↗