Search NASA⌕ Search

SEARCH · Search NASA

Results for “interval”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Satellite measurements of the charge composition of solar cosmic rays in the 6 less than or equal to Z less than or equal to 26 interval

The charge composition of solar cosmic rays were measured during two flares occurring in April and September 1971. The results were derived from a solid state dE/dx vs E telescope which was part of the cosmic ray experiment on the IMP 6 spacecraft. The data suggest that the helium to medium ratio may be varying from one flare to the next. The abundance ratios (normalized to oxygen) are compared with measurements of other investigators and significant disagreements are found. In particular, the data do not exhibit any systematic enhancement of heavy nuclei with respect to the spectroscopic abundances such as previously reported. Finally, the results are compared with the spectroscopically determined coronal and photospheric values, and again several important differences between the two sets of data are found.

Teegarden, B. J.↗

Effects of posture on exercise performance - Measurement by systolic time intervals.

Because posture significantly influences cardiac performance, the effects of moderate supine and upright ergometer exercise were compared on the basis of proportional (+37%) rate increments over resting control. Supine exercise produced significant decreases in left ventricular ejection time (LVET), pre-ejection period (PEP), and isovolumic contraction time (IVCT). Ejection time index (ETI) and corrected ejection time (LVETc) did not change significantly. Upright exercise produced greater decreases in PEP and LVET, but despite the rate increase there was no change in LVET, which resulted in sharp increases in ETI and LVETc. The discordant directional effects on LVET and its rate-correcting indices between the two postures were consistent with hemodynamic studies demonstrating lack of stroke volume change during supine exercise and increased stroke volume over control during light to moderate upright exercise.

Spodick, D. H.↗

A computer program to calculate zeroes, extrema, and interval integrals for the associated Legendre functions

A computer program is described for the calculation of the zeroes of the associated Legendre functions, Pnm, and their derivatives, for the calculation of the extrema of Pnm and also the integral between pairs of successive zeroes. The program has been run for all n,m from (0,0) to (20,20) and selected cases beyond that for n up to 40. Up to (20,20), the program (written in double precision) retains nearly full accuracy, and indications are that up to (40,40) there is still sufficient precision (4-5 decimal digits for a 54-bit mantissa) for estimation of various bounds and errors involved in geopotential modelling, the purpose for which the program was written.

Payne, M. H.↗

A survey of possible missions to the periodic comets in the interval 1974 - 2010

Catalogs are developed to survey the mission possibilities for the short period comets. In the first the physical and pertinent orbital characteristics are given for 65 short period comets. The second catalog is one containing the predicted perihelia for each of the 65 comets between 1974 and 2010. Geometry is included to indicate feasibility of Earth-based observation and sighting within 100 days of perihelion. The comets are divided on the basis of size and activity into three groups from the data in the first catalog: primary, secondary and low interest. The perihelia are separated into two groups: satisfactory and not satisfactory on the basis of earth-comet distance.

Bender, D. F.↗

Engineering information on an Analog Signal to Discrete Time Interval Converter (ASDT-IC)

An electronic control system for nondissipative dc power converters is presented which improves (1) the routinely attainable static output voltage accuracy to the order of + or - 1% for ambient temperatures from -55 to 100 C and (2) the dynamic stability by utilizing approximately one tenth of the feedback gain needed otherwise. Performance is due to a functional philosophy of deterministic pulse modulation based on pulse area control and to an autocompensated signal processing principle. The system can be implemented with commercially available unselected components.

Schwarz, F. C.↗

DMA precise time and time interval requirements

Defense Mapping Agency timing requirements ranging from milliseconds to tenths of nanoseconds and its use of geodetic astronomy and satellite geodesy programs are discussed in detail.

Carnahan, R. H.↗

Precise time and time interval (PTTI), an overview

Present applications of precise time and frequency (T/F) technology can be grouped as follows: (1) Communications systems which require T/F for time division multiplexing and for using spread spectrum techniques. (2) Navigation systems which need T/F for position fixing using a timed signal. (3) Scientific-Metrological applications which use T/F as the most precisely reproducible standard of measurement. (4) Astronomical-Space applications which cover a variety of the most demanding applications such as pulsar research, Very Long Baseline Interferometry (VLBI) and laser/radar ranging. In particular, pulsar time-of-arrival measurements require submicrosecond precision over a period of one-half year referred to an extraterrestrial inertial system, and constitute the most stringent requirements for uniform timekeeping to date.

Winkler, G. M. R.↗

Loran-C expansion: Impact on precise time/time interval

On 16 May 1974, it was announced that Loran-C was chosen as the navigation system to serve the U. S. Coastal Confluence Zone. At the present time, reliable CONUS Loran-C groundwave timing coverage extends westward only about as far as Boulder, CO. The groundwave hyperbolic and timing coverage which will result from the planned CONUS expansion are illustrated. Time frames are provided. A status report on the planned reduction in Loran-C PTTI tolerances is presented.

Roeber, J. F., Jr.↗

Integration-free interval doubling for Riccati equation solutions

Various algorithms are given for the case of constant coefficients. The algorithms are based on two ideas: first, relate the Re solution with general initial conditions to anchored RE solutions; and second, when the coefficients are constant the anchored solutions have a basic shift-invariance property. These ideas are used to construct an integration free superlinearly convergent iterative solution to the algebraic RE. The algorithm, arranged in square-root form, is thought to be numerically stable and competitive with other methods of solving the algebraic RE.

Bierman, G. J.↗

SAS-2 observations of the diffuse gamma radiation in the galactic latitude interval 10 deg absolute b or equal to 90 deg

An analysis of all of the second small astronomy satellite gamma-ray data for galactic latitudes with the absolute value of b 10 deg has shown that the intensity varies with galactic latitude, being larger near 10 deg than 90 deg. For energies above 100 MeV the gamma-ray data are consistent with a latitude distribution of the form I(b) = C sub 1 + C sub 2/sin b, with the second term being dominant. This result suggests that the radiation above 100 MeV is coming largely from local regions of the galactic disk. Between 35 and 100 MeV, a similar equation is also a good representation of the data, but here the two terms are comparable. These results indicate that the diffuse radiation above 35 MeV consists of two parts, one with a relatively hard galactic component and the other an isotropic, steep spectral component which extrapolates back well to the low energy diffuse radiation. The steepness of the diffuse isotropic component places significant constraints on possible theoretical models of this radiation.

Fichtel, C. E.↗

The effect of pulse interval statistics on the spectrum of radiation from lightning

An analysis of atmospheric radio noise originally appearing in the literature to describe the VLF structure of atmospherics is repeated here, keeping a term discarded in the previous work and extending the results to include all frequencies and some simple effects of amplitude variations. It is shown that at high frequencies, atmospheric radiation appears to be the result of incoherent sources, whereas at low frequencies the sferics appear to originate from coherent sources. These conclusions are valid with only weak restrictions, regardless of the actual statistical model assumed for the process. An implication of these results is that at high frequencies the magnitude of the spectrum of the received signal can be related to the spectrum of the source current, a means for the study of lightning current wave forms thus possibly being provided.

D M Le Vine↗

Recovery from exercise at varying work loads - Time course of responses of heart rate and systolic intervals

The time course of the recovery period was characterized by noninvasive measurements after 4 minute bicycle exercise at 3 separate work loads in volunteers with normal peak responses. Most responses started immediately to return toward resting control values. Left ventricular ejection time and stroke volume change are discussed. Changes in pre-ejection period were determined by changes in isovolume contraction time, and factors affecting the degree and rate of return are considered. The rates of change in the ejection time index and in the ratio pre-ejection period/left ventricular ejection time were virtually independent of load throughout most of recovery.

Nandi, P. S.↗