Search NASA⌕ Search

SEARCH · Search NASA

Results for “islanding operation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Eastern North Atlantic (ENA) Aerosol Observing System (AOS) Instrument Handbook

The U.S. Department of Energy ARM user facility’s ENA AOS, designated AOS06, entered service in October of 2013 at the ARM Facility on Graciosa Island, Azores. The Aerosol Observing System is meant to be a standalone, completely autonomous, aerosol sampling system. It requires only power, 208VAC 1φ or 440 VAC 1φ, and an internet connection to be operational. The physical structure is a standard-sized shipping container, 20 feet long by 8 feet wide. Inside, the walls, ceiling, and floors are insulated using >3.5” of spray polyurethane foam with an R-value of 6.2/inch of insulation. The interior walls, floor, and ceiling are lined with ¾” plywood for durability and have integrated unistrut for mounting equipment.

54 ENVIRONMENTAL SCIENCES↗

Microphysical-macrophysical interactions in low cloud systems over the Eastern North Atlantic

How low clouds over the oceans respond to changes in atmospheric greenhouse gases and aerosol particles is poorly understood. Climate model disagreement in these responses limits the accuracy of predictions of future climate. Processes governing the behavior of marine low cloud need to be improved in models and comprehensive long-term observations provide important constraints. Cloud structure and impacts on climate are shaped by processes operating on a wide range of time and space scales, which interact to modulate cloud dynamics, boundary layer structure, and precipitation. The Atmospheric Radiation Measurement (ARM) Eastern North Atlantic (ENA) site at Graciosa Island (Azores, 28°W 39°N) began taking measurements in late 2013 to address the need for comprehensive cloud, aerosol, and meteorological observations in a remote marine low cloud environment. The site straddles the boundary between the subtropical and midlatitude climate zones in the eastern North Atlantic and experiences a great diversity of meteorological and cloud conditions. In addition, the ENA site is downwind of the North American continent and is periodically impacted by continental aerosol particles transported there on the prevailing winds. In response to a 2014 proposal call, our team (ENA Site Science Team) laid out a strategy to accelerate research focused on understanding the multi-scale interactions that shape cloud properties by maximizing the utility of the observational capabilities of the ENA site. The proposed work aligned with the scientific directions of the ASR Working Groups. The team, together with collaborators, conducted a program of research focused upon multi-scale cloud processes. The team worked with scientists both within and outside the Atmospheric System Research (ASR) program, and with the ARM infrastructure to ensure that the full potential of the ENA site is realized. The suite of instruments at the ENA site has been increasing since the site’s inception and is now essentially complete. In 2019, we laid out a two-year extension of the research, and were granted an extension of the Site Science award.

54 ENVIRONMENTAL SCIENCES↗

Management of the Three Mile Island, Unit 2, Accident Corium and Severely Damaged Fuel Debris

The Three Mile Island, Unit Two (TMI-2) pressurized water reactor core melted down in 1979 due to an untimely combination of maintenance problems that led to a loss of feedwater, followed by a series of operational misunderstandings and errors. The melted core recovery process required development of a wide array of tools. After approximately three years of water management and other cleanup actions, the first views of the core revealed a much higher degree of damage than previously expected. Approximately 62 metric tons of the core had melted, leaving only 42 of the 177 fuel assemblies standing with a majority of rods intact. The core to be recovered was composed of loose debris and a solidified mass of formerly molten fuel. Robotic tools that had been designed for the task were of limited effectiveness due to the range of material types and phases. Over a period of several years, the central melt was broken up, primarily by use of a core-boring drill originally designed to acquire samples through the depth of the debris field. The broken pieces were loaded into specially designed debris canisters by use of long-handled pick-and-place tools and suctioned into baffled knockout canisters using an airlift vacuum system. A remotely operable underwater plasma arc torch was developed for removal of the lower core support structure to be able to retrieve the fuel pieces and secondary melt that had accumulated on the bottom reactor vessel head. Canister design played a central role in defining the initial retrieval process and later affected transportation, interim wet and its current interim dry storage. Due to concerns about the potential for radiolysis of residual water in the debris and other canister material, the canisters were fitted with hydrogen recombiner catalyst units to prevent a buildup of flammable gas and potential pressurization. To confirm the effectiveness of the recombiners during shipping, eight dewatered canisters were kept sealed for up to 205 days with periodic sampling of the headspace gas. The highest hydrogen value (9 vol%) was observed in a canister held for 147 days while the longest stored canister resulted in a 5% hydrogen concentration. The oxygen concentration never exceeded 0.5 %, and the primary backfill was >80% argon, meaning there was no flammability risk. Radiolytic hydrogen was also observed in wet pool storage, where the vented canisters discharged a portion of the water backfill as a result of gas production. The 344 canisters (268 fuel debris, 62 filter, and 12 knockout type) were dewatered, loaded in groups of seven into a double barrier shipping cask, and transported to the U.S. Department of Energy site in Idaho for 10 years of pool storage.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Multi-Timescale Integrated Dynamics and Scheduling for Solar (MIDAS-Solar) (Final Technical Report)

Solar photovoltaic (PV) installations have experienced unprecedented growth in the United States. PV will become not only an energy producer but also a necessary provider of ancillary services at multiple timescales. Conventional methods to simulate power systems operations - such as long-term production simulation (which typically considers schedules from hours to minutes by using an optimization framework) and short-term transient studies (which simulate dynamics from seconds to sub-seconds using state variables and differential equations) - are not sufficient for studying the multiple-timescale variation of solar generation and its impact on system reliability. Long-term system economics and short-term system dynamics are highly coupled, particularly when the penetration level of renewable generation is extremely high, because the uncertainty and variability of solar generation will impact both power system steady-state and dynamic performance. This project helps meet and exceed the U.S. Department of Energy Office of Energy Efficiency and Renewable Energy Solar Energy Technologies Office goal of systems integration by directly addressing this stability and reliability challenge for power grid planning and operation. We have developed a temporally comprehensive, closed-loop simulation model, named Multi-timescale Integrated Dynamics and Scheduling (MIDAS), that seamlessly simulates power system operations from economic scheduling (day-ahead to hours) to dynamic response analysis (seconds to sub-seconds). For schedules with very high levels of inverter-based resources (IBRs), up to and including 100%, the stability of grid controls has been evaluated through electromagnetic transient (EMT) simulations and power-hardware-in-the-loop (PHIL) simulations of key transient events at key schedule points. Specifically, MIDAS provides: 1) a closed-loop simulation framework for simulating timescales from economic scheduling to dynamic stability analysis; 2) machine learning-based stability assessment; 3) EMT modeling and analysis for large-scale power systems; 4) MIDAS PHIL test bed. We worked with Hawaii Electric Companies to apply the MIDAS study framework to a Maui grid study. The entire island's transmission system was modeled in detail - from a yearly scheduling model, to a second-level frequency dynamic model, down to a sub-second-scale EMT model to address critical stability issues. The project demonstrated how MIDAS can help system planners and operators assess system reliability and stability while the power grid is marching toward a high-renewable, high-IBR future. In this Maui grid study, we found that 100% instantaneous IBR operation is achievable in EMT simulation and PHIL testing, and grid planners and operators might need new analysis/simulation tools to assess grid reliability and stability in the scheduling stage. MIDAS will bring Maui and other systems closer to 100% clean and stable energy futures. (In this study, we examined transient stability. Other topics necessary for 100% IBR operation, such as protection and resource adequacy, were not examined.)

100% Renewables↗

Witness from the sky: How the Lab photographed fireballs from above

In the spring of 1948, a workforce of more than 10,000 converged on three islands of the Pacific Proving Grounds. Among them, lines of men hauled hundreds of pounds of state-of-the-art photographic equipment onto an array of aircraft. A series of nuclear tests – called Operation Sandstone – would take place and they were going to capture it from the sky.

99 GENERAL AND MISCELLANEOUS↗

Retrofittable Advanced Combined Cycle Integration for Flexible Decarbonized Generation

This is the final scientific / technical report for Front End Engineering Design (FEED) study “Retrofittable Advanced Combined Cycle Integration for Flexible Decarbonized Generation” funded by the US Department of Energy (DOE), Office of Fossil Energy and Carbon Management (FECM), Carbon Capture R&D Program under award DE-FE0032131. The prime recipient is General Electric Company working through its Gas Power division (GEGP) with subrecipients Southern Company and Linde Engineering plus subcontractor Kiewit. Southern Company’s Plant Barry, a 2x1 7F.04 CCGT, is the host site. GEGP led the overall integration of the carbon capture system (CCS) with the existing natural gas combined cycle (NGCC) facility. Linde provided the detailed process engineering and equipment costing for the carbon capture island. Kiewit focused on plant layout, constructability, and installation. With the FEED study finished, the engineering is approximately 50% complete towards the detailed design package needed to proceed to procure, install, build, commission, and operate the integrated NGCC+CCS facility. This FEED study focuses on retrofitting a 95% CO 2 capture system with attention on plant integration. The study was particularly challenging due to unique and substantial cost impacts related to global sourcing challenges associated with COVID. Additional incentives, regulatory support, and dispatch certainty are needed to move forward with implementing CCS at this or other sites in the US. This FEED study highlights the value of integrating NGCC+CCS and is a template for future CCS retrofit studies.

42 ENGINEERING↗

Case Study: Hybridizing Nuclear Energy Systems in the U.S.

This case study was presented at the ICTP-IAEA VIRTUAL Course on Nuclear-Renewable Integrated Energy Systems: Phenomenology, Research and Development. It provides preliminary results on an analysis of hybridizing the two nuclear power plants owned by Xcel Energy and located in Minnesota. The analysis extends previous analyses that provided only price-taker results. Those assume adjusting the generation sold to the grid does not impact locational marginal electricity prices nor do they estimate impacts on the total net cost to serve the load. This presentation summarizes the new technique that was developed to both optimize the size and operations of the hybridized system and the resulting impacts on the grid when it is operated optimally.

ENERGY PLANNING, POLICY, AND ECONOMY↗

A Generalized Framework for Service Restoration in a Resilient Power Distribution System

An electric power grid is one of the complex infrastructures, and because of its complex nature, there is simply no way that outages can be completely avoided. Thus, a modern society that depends on reliable electric supply requires a resilient electric system that can recover from disruptions while integrating emerging smart grid technologies. Here, this article presents a novel approach for service restoration in a modern power distribution system with controllable switches and distributed generation (DG) resources for any kind of outage. The proposed framework supports both the traditional service restoration using feeder reconfiguration and the grid-forming DG-assisted intentional islands that are dynamically sized using algorithms based on the fault scenario, available resources, and priority of loads. The problem is formulated as a mixed-integer linear program that incorporates critical system connectivity and operating constraints. Simulations are performed to demonstrate the effectiveness of the proposed approach using a large-scale four-feeder 1069-bus three-phase unbalanced distribution test system. It is demonstrated that the framework is effective in utilizing all available resources in quickly restoring the power supply to improve resiliency during extreme events and is scalable for a large-scale unbalanced power distribution system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Enhancing Local Grid Resilience with Small Hydropower Hybrids: Proving the concept through demonstration, simulation, and analysis with Idaho Falls Power

Large hydropower, connected to the transmission system and typically possessing significant ability to balance grid frequency, has long been central to black start plans in regions where it is present. Small hydropower possesses most of the attributes required for black start but is often connected to distribution or sub-transmission systems and has less ability to balance grid frequency. Integrating energy storage such as batteries or ultracapacitors increases the combined asset’s ability to balance frequency. This asset integration enables a bottom-up grid restoration paradigm in which critical electric loads on the local distribution system can be powered even when the regional transmission system is down. This report presents a field demonstration conducted with Idaho Falls Power that proved this concept. The contribution of energy storage in restoring the small hydro-dominated distribution grid and its operational sensitivity across different control settings are further analyzed using high-fidelity simulations. Readers will learn about technical details on the field demonstration setup, energy storage contribution to black start, detailed simulation steps of islanded distribution grid restoration, and usage of field demonstration measurements for transient model refinements. Collectively this report points to a great opportunity for small hydropower to enhance resilience of local electric grids.

13 HYDRO ENERGY↗

Management of the Three Mile Island Unit 2 Accident Corium and Severely Damaged Fuel Debris (Rev. 2)

The Three Mile Island, Unit Two (TMI-2) pressurized water reactor core underwent a significant meltdown in 1979 due to an untimely combination of maintenance problems that led to a loss of feedwater, followed by a series of operational misunderstandings and errors. Primary coolant discharging through a malfunctioning valve represented what was analyzed as a “small-break” loss-of-coolant accident (LOCA) and ultimately became a full core meltdown. The melted core recovery process required the development of a wide array of tools. After approximately three years of water management and other cleanup actions, the first views of the core revealed a much higher degree of damage than previously expected. Approximately 62 metric tons of the core had melted, leaving only 42 of the 177 fuel assemblies standing with fuel rods intact. The core to be recovered was composed of loose, gravel-like and granular particulate material and a central solidified mass of formerly molten fuel. Molten fuel had also penetrated some of the pressure vessel internals and resolidified below the main core support structure. Robotic tools that had been designed for the task were of limited effectiveness due to the range of material types and phases.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Management of the Three Mile Island Unit 2 Accident Corium and Severely Damaged Fuel Debris (Rev. 2)

The Three Mile Island, Unit Two (TMI-2) pressurized water reactor core underwent a significant meltdown in 1979 due to an untimely combination of maintenance problems that led to a loss of feedwater, followed by a series of operational misunderstandings and errors. Primary coolant discharging through a malfunctioning valve represented what was analyzed as a “small-break” loss-of-coolant accident (LOCA) and ultimately became a full core meltdown. The melted core recovery process required the development of a wide array of tools. After approximately three years of water management and other cleanup actions, the first views of the core revealed a much higher degree of damage than previously expected. Approximately 62 metric tons of the core had melted, leaving only 42 of the 177 fuel assemblies standing with fuel rods intact. The core to be recovered was composed of loose, gravel-like and granular particulate material and a central solidified mass of formerly molten fuel. Molten fuel had also penetrated some of the pressure vessel internals and resolidified below the main core support structure. Robotic tools that had been designed for the task were of limited effectiveness due to the range of material types and phases.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Thermodynamics and kinetics of Pb intercalation under graphene on SiC(0001)

SiC-supported graphene intercalated by a two-dimensional Pb monolayer can provide an appealing platform for spintronic applications. Such a monolayer structure is thermodynamically ultrastable, as observed in recent experiments. However, important fundamentals such as the structure of intercalated phases, locations of intercalated atoms, thermodynamic preference for intercalation, and intercalation pathways for this system have not yet been understood conclusively. Here, in this work, extensive density functional theory calculations are performed to assess Pb intercalation thermodynamics and kinetics under graphene on SiC(0001). We find that intercalation of isolated Pb atoms is strongly disfavored over adsorption on top of graphene. However, intercalation of complete Pb layers in the gallery between SiC and graphene buffer layer is strongly favored over supported Pb monolayers and moderately favored over formation of supported large three-dimensional Pb islands. We also find that initiation of intercalation either by individual Pb atoms directly penetrating graphene or by hopping under a static graphene step edge is energetically prohibitive at experimental temperatures. Consequently, more complex intercalation pathways are operative and further analyzed. We demonstrated that once an intercalated Pb monolayer forms around a graphene step edge, a facile Pb mass transport by Pb vacancy-mediated diffusion can be triggered for continued growth of the intercalated monolayer.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Examining the Ice-Nucleating Particles from the Eastern North Atlantic (ExINP-ENA) (Field Campaign Report)

The Examining the Ice-Nucleating Particles from the Eastern North Atlantic (ExINP-ENA) field campaign was conducted at the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility’s Eastern North Atlantic (ENA) observatory on Graciosa Island, Azores (39.0916° N, 28.0257° W). The ExINP-ENA campaign began on October 1, 2020, and collected data until March 28, 2021, for a total of 179 days of data generated, with a 45-day intensive operational period (IOP) from October 10 to November 24. This campaign was funded by the DOE Office of Science Early Career Research Program through grant DE-SC001879. This grant contains funding for three field campaigns. The previous field campaign at the Southern Great Plains (SGP) site in Oklahoma, ExINP-SGP, was completed in 2020 (36.6073° N, 97.4876° W), and the upcoming field campaign at the North Slope of Alaska (NSA), ExINP-NSA, will take place from October 2021 at the National Oceanic and Atmospheric Administration (NOAA) Barrow Atmospheric Baseline Observatory (71.3230° N, 156.6114° W).

54 ENVIRONMENTAL SCIENCES↗

Overview of the recent experimental research on the J-TEXT tokamak

The J-TEXT capability is enhanced compared to two years ago with several upgrades of its diagnostics and the increase of electron cyclotron resonance heating (ECRH) power to 1 MW. With the application of electron cyclotron wave (ECW), the ECW assisted plasma startup is achieved; the tearing mode is suppressed; the toroidal injection of 300 kW ECW drives around 24 kA current; fast electrons are generated with toroidal injected ECW and the runaway current conversion efficiency increases with ECRH power. The mode coupling between 2/1 and 3/1 modes are extensively studied. The coupled 2/1 and 3/1 modes usually lead to major disruption. Their coupling can be either suppressed or avoided by external resonant magnetic perturbation fields and hence avoids the major disruption. It is also found that the 2/1 threshold of external field is significantly reduced by a pre-excited 3/1 mode, which can be either a locked island or an external kink mode. The disruption control is studied by developing prediction methods capable of cross tokamak application and by new mitigation methods, such as the biased electrode or electromagnetic pellet injector. The high-density operation and related disruptions are studied from various aspects. Approaching the density limit, the collapse of the edge shear layer is observed and such collapse can be prevented by applying edge biasing, leading to an increased density limit. The density limit is also observed to increase, if the plasma is operated in the poloidal divertor configuration or the plasma purity is increased by increasing the pre-filled gas pressure or ECRH power during the start-up phase.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Transactive Energy Rationing in Islanded Electric Power Systems

Extreme weather events, many of which are climate change related, are occurring with increasing frequency and intensity and causing catastrophic outages. One of the major modern-day concerns of utilities is dealing with such extreme outages and consequently, its repercussions on the lives of people in society and social aspects. Traditionally, operators have been using rolling blackouts as a contingency plan to serve critical loads during such events when electricity supply is scarce. However, such blackouts practices are executed on a last-minute mandatory basis, depriving customers having low-capacity high priority loads (i.e. refrigeration, water, telecommunication, etc) that should also be serviced if at all possible. Historically, policymakers have often adopted quota-based regulatory actions or rationing for other commodities (such as gasoline, butter, sugar) to handle scarcity situations. Motivated from such quota based systems, our contribution presented in this work is an alternative transactive rationing mechanism that would provide some minimum level of service to all of the customers and serve the critical loads using market-based control during such scarcity-based contingencies. This is in contrast to the state-of-art TE mechanisms that allocate resources to customers solely based on their willingness-to-pay. The effectiveness of the proposed mechanism is demonstrated through simulation-based evaluation on two real-life use cases having feeder-level and microgrid-level configurations respectively. The simulation results clearly demonstrate the capability of the rationing scheme to serve customers’ high-priority loads through prolonged outages even during extreme scarcity scenarios.

42 ENGINEERING↗

A Fast and Scalable Genetic Algorithm-Based Approach for Planning of Microgrids in Distribution Networks

As a result of climate change, extreme weather events are occurring more frequently and with increasing impact. This trend poses a significant challenge for distribution utilities and system operators to ensure that there is uninterrupted power supply to critical loads in their networks; thus, the level of proactive preparation of the distribution system to be able to handle severe impacts of extreme weather events represents the system's resilience. One method that distribution system planners can use to prepare for future extreme events is to plan multiple microgrids which can use local generation as much as possible to supply critical loads. But partitioning an existing distribution system such that multiple feasible islands are planned and which are capable of supporting critical loads is still challenging for distribution systems - first, because of the size of the network graph partitioning problem and, second, because of the difficulty in properly formulating the desired attributes of such islands or microgrids. Therefore, this paper presents a genetic algorithm based approach that facilitates incorporating multiple objectives for grid partitioning by formulating two types of problems - node allocation and edge elimination - and it considers multiple topological and resilience-enhancing objectives. The performance of the proposed genetic algorithm-based approach is numerically evaluated on multiple test systems as well as on a real distribution feeder in Colorado, United States.

genetic algorithm↗

The Gross-Neveu-Yukawa archipelago

We perform a bootstrap analysis of a mixed system of four-point functions of bosonic and fermionic operators in parity-preserving 3d CFTs with O(N) global symmetry. Our results provide rigorous bounds on the scaling dimensions of the O(N)-symmetric Gross-Neveu-Yukawa (GNY) fixed points, constraining these theories to live in isolated islands in the space of CFT data. We focus on the cases N = 1, 2, 4, 8, which have applications to phase transitions in condensed matter systems, and compare our bounds to previous analytical and numerical results.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design, Optimization, and Control of Floating Offshore Wind Farms for Optimal Energy Production (Final report)

The uncertainty and irregularity of ocean waves and the ocean environment is a major factor in the development of commercial scale floating wind turbines as the operation of floating structures in such an environment can lead to irregular and unpredictable loading, fatigue, and ultimately a reduction in the operational life of the turbine system which affects energy production over the lifetime of the turbine. Control solutions that can limit float motions and mitigate stressful events on the structure become essential for extending lifetime and limiting the operational uncertainty of a floating wind turbine. Digital twins are computational replicas of physical systems that operate in parallel with the operation of the physical system. Given advanced knowledge of a systems input, digital twins have the ability to predict the behavior of a system in advance, which can be valuable in the control of that system. In this project, we developed and assessed potential digital twin models developed in house and openly available (OpenFast) for use in the real time control of the six degree of freedom response motions of a floating wind turbine in ocean waves. Coupling these models with near-field real time irregular sea surface (wve) measurement/sensings and prediction models, we used the digital twin to predict how the floating turbine will respond to the incoming waves. Applying this information to a motion control system of the float, one can limit and control float motions to prevent undesirable loading events/large angular motions, thus increasing system life and ultimately contributing to optimizing energy production. Due to the computational intensity of operating a digital twin in real time, we investigated the use of artificial intelligence techniques to speed-up the processes of the digital twin, as well as the wave reconstruction/prediction models. Model tank testing at the University of Rhode Island and University of Maine both validated and demonstrated the developed techniques on simple float geometries and a scale model of the NREL 15 MW reference turbine.

17 WIND ENERGY↗