Search NASA⌕ Search

SEARCH · Search NASA

Results for “level sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Actuator and Motor Control End-to-End V&V on the Mars 2020 Rover

The Mars 2020 Perseverance rover is the most advanced robotic exploration system ever sent to another planet. To support the complex scientific and mobility needs of the mission, the rover utilizes 33 actuators, three multi-degree-of-freedom force-torque sensors, fifteen single or dual-speed resolvers, two solenoid valves, and twelve contact switches. The control for these actuators and sensors is achieved by several levels of flight software, coordinated between two computers with varying bandwidth control loops. Furthermore, the actuators and sensors were integrated into multiple larger robotic mechanisms that were delivered by different organizations at various points in the Integration and Test (I&T) timeline. All of this created a very complex Verification and Validation (V&V) scenario involving multiple subsystems and teams, several hardware and software testbeds with varying levels of fidelity, and significant systems engineering to ensure the overall I&T schedule could be maintained while ensuring system hardware safety.This paper details the integrated V&V effort across multiple teams and venues to provide full coverage of all necessary functionality, performance, and fault protection. First, it provides an overview of how the V&V campaign was subdivided among teams and venues and provides descriptions of the various hardware configurations used to support the testing. The Mars 2020 implementation of the plan incorporates many of the lessons learned from Mars Science Laboratory’s test campaign, and these value-added modifications are discussed here. Also included in this section is the system-level environmental testing approach used for mechanisms. Second, the paper describes the phased approach used by the teams to support new hardware and software deliveries to testbed and Systems I&T. In this approach the test campaign was built upon higher-level mechanism needs for performance, functionality, and safety at specific times in the campaign. Finally, the paper discusses lessons learned from the V&V campaign that should be applied to future large-scale motion control testing efforts.

Borne, Davis↗

Development and flight tests of a gyro-less wing leveler and directional autopilot

A gyro-less wing leveler and directional autopilot were developed and flight tested in a single-engine light airplane. The primary purpose of the project was to develop a simple, reliable, low-cost stability augmentation and autopilot system for light aircraft. The wing leveler used a fluidic inertial rate sensor, electronic signal processing circuitry, and vacuum operated servos. A strap-down magnetic heading reference of simple design provided the wing leveler with directional autopilot capability. Flight tests indicated that the performance of the gyro-less wing leveler was equal to that of a commercial wing leveler using a gyroscopic rate sensor. Drift-free, long-term, heading-hold capability of the magnetic heading reference was demonstrated.

Garner, H. D.↗

Wide angle astrometric demonstration on the micro-arcsecond metrology testbed for the space interferometry mission

The Space Interferometry Mission (SIM) requires fringe measurements to the level of picometers in order to produce astrometric data at the micro-arc-second level. To be more specific, it is necessary to measure both the position of the starlight central fringe and the change in the internal optical path of the interferometer to a few hundreds of picometers. The internal path is measured with a small heterodyne metrology beam, whereas the starlight fringe position is estimated with a CCD sampling a large concentric annular beam. One major challenge for SIM is to align the metrology beam with the starlight beam to keep the consistency between these two sensors at the system level while articulating the instrument optics over the field of view.

metrology↗

Hanford Under-tank Inspection with Ultrasonic Volumetric Non-destructive Examination Technology - 18470

The U.S. Department of Energy (DOE) and the Hanford Site Tank Operations Contractor Washington River Protection Solutions, LLC (WRPS) are sponsoring a non-destructive evaluation (NDE) technology development program to identify and mature volumetric (non-visual) NDE technology that will enable the examination of Hanford double-shell tank (DST) bottoms. NDE technology for Hanford under-tank examination will be made possible through technology maturation that includes adaptation of NDE sensor technology to overcome access challenges presented by tank risers and refractory pad air-slots, followed by integration with robotic delivery systems, and ultimately qualification and deployment of the inspection systems. The stages of technology maturation and the testing and evaluation required to support the process are organized under three program phases: Phase I - NDE Capability Testing: Identify and down-select NDE technologies based on flaw detection and characterization abilities only; Phase 2 - NDE Delivery System Testing: Mature promising NDE technologies to adapt transducer hardware and robotic delivery system to address access challenges; Phase 3 - Full-scale Demonstration of Integrated NDE System: Demonstrate adapted NDE technologies in a cold test platform to challenge flaw detection and navigation abilities. Phase I of the program, which was initiated and completed in FY2017, focused on completing the following five key activities: 1. Identifying a broad cross section of potentially applicable NDE volumetric inspection technologies for under-tank examination. 2. Down-selecting the broad set of NDE technologies to a set of strong candidates based on initial flaw detection performance and potential to be adapted/matured to overcome primary tank access challenges posed by access risers and/or refractory pad air-slots. 3. Evaluating the flaw detection performance of the candidate sensors through testing. 4. Using the test results to baseline sensor performance against the flaw detection requirements established for high-level waste tanks. 5. Assessing the trade-offs and vulnerabilities of the candidate sensors that would negatively impact sensor performance reliability or complicate tank inspection operations. The completion of the first three key activities satisfied the first two Phase I test objectives, which were to complete Technology Screening and Sensor Effectiveness Testing. Completion of the fourth key activity satisfied the final test objective of Phase I, which was to determine the extent to which the sensors can satisfy high-level waste tank flaw detection requirements. Sensor flaw detection performance testing yielded several suitable sensor technology options, although each has specific risks or challenges that would need to be accepted or overcome. Thus, the fifth key activity was performed to evaluate sensor risks and challenges for consideration with flaw detection performance. The Phase I evaluation outcomes will be used to support the Phase I programmatic objective, which is to identify one or more NDE sensor technologies for adaptation and maturation for the DST environment. Selection of one or more sensors will mark the culmination of Phase I of the NDE Technology Development Program and allow progression to Phase II.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

AI-powered municipal solid waste management: a comprehensive review from generation to utilization

The accumulation of municipal solid waste (MSW) continues to rise due to burgeoning population, rapid global urbanization and economic growth, intensifying ecological concerns associated with landfills and greenhouse gas (GHG) emissions. Over the past 2 decades, global waste generation has surged by 50%, with one-third remaining uncollected and about 70% sent to landfills. This review examines the critical role of integrating emerging technologies, such as advanced sensors and artificial intelligence (AI), into end-to-end MSW management to alleviate landfill burdens. The suitability of various AI tools for different stages of MSW management is assessed, alongside the deployment of advanced sensors including hyperspectral cameras, computer vision systems, and internet of things (IoT) devices for material identification. Applications of genetic algorithms and reinforcement learning for optimizing collection routes, reducing costs, and lowering emissions are highlighted. Life cycle assessment (LCA) across all stages of MSW management is also reviewed, along with future trends in leveraging generative AI, natural language processing (NLP), and agent-based AI systems to analyze waste generation patterns and public sentiment. Efficient collection and handling can be enhanced through route optimization with geographic information systems and real-time bin-level monitoring. Furthermore, sensor-embedded, real-time object detection systems paired with robotics enable material characterization and automated sorting, thereby lowering costs and diverting waste from landfills into value-added products for diverse industrial sectors including packaging, chemicals, textiles, metals and glass, transportation, and electronics industries. Without intervention, global waste is projected to reach 4.54 billion tons by 2050, contributing direct economic costs of $\$$400 billion and roughly 2.38 billion tons of CO 2 -equivalent emissions annually. This review demonstrates how AI-driven, end-to-end solutions for MSW management can mitigate economic and environmental challenges, while directly supporting the United Nations Sustainable Development (UNDP) goals related to innovation and infrastructure (SDG 9), sustainable cities (SDG 11), responsible consumption and production (SDG 12), and climate action (SDG 13).

09 BIOMASS FUELS↗

Piloted "Well Clear" Performance Evaluation of Detect-and-Avoid Systems with Suggestive Guidance

This study evaluated the performance of four prototype unmanned aircraft detect-and-avoid (DAA) display configurations, each with different informational elements driven by alerting and guidance algorithms. Sixteen unmanned aircraft pilots flew each combination of the display configurations, with half being given zero DAA surveillance sensor uncertainty and the other half experiencing errors that were comparable, and in some cases slightly better than, errors that were measured in DAA system flight tests. The displays that showed intruder alert information in altitude and heading bands had significantly fewer losses of well clear compared with alternative displays that lacked that information. This difference was significant from a statistical and practical perspective: those losses that did occur lasted for shorter periods and did not penetrate as far into the geometric "separation cylinder" as those in the non-banded displays. A modest level of DAA surveillance sensor uncertainty did not affect the proportion of losses of well clear or their severity. It is recommended that DAA traffic displays implement a band-type display in order to improve the safety of UAS operations in the National Airspace System. Finally, this report provides pilot response time distributions for responding to DAA alerts.

unmanned aircraft system↗

Non-destructive evaluation and machine learning methods for inspection of spent nuclear fuel canisters: A state-of-the-art review

Nuclear energy is among the cleanest and most efficient energy sources currently available. The operation of nuclear power plants (NPPs) produces large amounts of high-level radioactive waste known as spent nuclear fuel (SNF). Currently, large amounts of SNF is stored in dry cask storage systems (DCSSs) for extended interim storage until a permanent disposal solution becomes available. During the extended interim storage, the DCSS, particularly the SNF canisters, may degrade and abnormal conditions may occur. Therefore, non-destructive evaluation (NDE) and machine learning (ML) approaches are necessary for inspection of SNF canisters. This paper presents a state-of-the-art review of literature by summarizing recent progress made on the applications of NDE and ML for inspection of SNF canisters. Sixteen NDE methods are examined and compared: visual inspection, ultrasonic guided waves (UGWs), laser-based approaches, acoustic emission (AE), eddy current testing (ECT), non-invasive acoustic sensing, dynamic modal testing, cosmic ray muons tomography, neutron imaging, gamma rays detection, fiber optical sensors, through-wall communications, X-ray computed tomography (CT), vibrothermography, monoenergetic photon sources, and surface acoustic wave (SAW) sensors. The technology readiness level (TRL) for each method is assessed and compared. Recent publications on ML-enhanced visual inspection, AE, non-invasive acoustic sensing, dynamic modal testing, and neutron imaging for SNF canisters are summarized and future research needs are identified. In conclusion, this review article provides a convenient reference on the state-of-the-art applications of NDE and ML methods for inspection of SNF canisters.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Fano-noise-limited CCDs

Recent developments of scientific CCDs have produced sensors that achieve ultra low read noise performance (less than 2 electrons rms) and near perfect charge transfer efficiency (0.9999996) without the addition of a fat-zero. This progress has now made it possible to achieve Fano-noise-limited performance in the soft X-ray where the detector's energy resolution is primarily limited by the statistical variation in the charge generated by the interacting X-ray photon. In this paper, Fano-noise-limited test data is presented for two different CCD types and a CCD derived estimate of the Fano factor is determined. By evaluating ultra low-modulation images (less than 1 electron peak-to-peak) it is shown that the CCD's global CTE is now superior to its read noise floor. To capitalize on this capability CCD manufacturers are now focusing their attention on reducing the noise floor below the 1 electron level thereby matching the sensor's CTE performance. This improvement, if accomplished, will push Fano-noise-limited performance for the CCD into the extreme ultra-violet.

Janesick, James↗

Space remote sensors

Space remote sensors are analyzed as a component of a higher level 'robotic' system and the implications for sensor parameter selection and priority assignment are described. The EOS program and three of its particular sensor types are considered as examples of the principles discussed.

Keller, Sam↗

Optimal Stimulus Amplitude for Vestibular Stochastic Stimulation to Improve Sensorimotor Function

Sensorimotor changes such as postural and gait instabilities can affect the functional performance of astronauts when they transition across different gravity environments. We are developing a method, based on stochastic resonance (SR), to enhance information transfer by applying non-zero levels of external noise on the vestibular system (vestibular stochastic resonance, VSR). Our previous work has shown the advantageous effects of VSR in a balance task of standing on an unstable surface. This technique to improve detection of vestibular signals uses a stimulus delivery system that is wearable or portable and provides imperceptibly low levels of white noise-based binaural bipolar electrical stimulation of the vestibular system. The goal of this project is to determine optimal levels of stimulation for SR applications by using a defined vestibular threshold of motion detection. A series of experiments were carried out to determine a robust paradigm to identify a vestibular threshold that can then be used to recommend optimal stimulation levels for SR training applications customized to each crewmember. Customizing stimulus intensity can maximize treatment effects. The amplitude of stimulation to be used in the VSR application has varied across studies in the literature such as 60% of nociceptive stimulus thresholds. We compared subjects' perceptual threshold with that obtained from two measures of body sway. Each test session was 463s long and consisted of several 15s sinusoidal stimuli, at different current amplitudes (0-2 mA), interspersed with 20-20.5s periods of no stimulation. Subjects sat on a chair with their eyes closed and had to report their perception of motion through a joystick. A force plate underneath the chair recorded medio-lateral shear forces and roll moments. First we determined the percent time during stimulation periods for which perception of motion (activity above a pre-defined threshold) was reported using the joystick, and body sway (two standard deviation of the noise level in the baseline measurement) was detected by the sensors. The percentage time at each stimulation level for motion detection was normalized with respect to the largest value and a logistic regression curve fit was applied to these data. The threshold was defined at the 50% probability of motion detection. Comparison of threshold of motion detection obtained from joystick data versus body sway suggests that perceptual thresholds were significantly lower, and were not impacted by system noise. Further, in order to determine optimal stimulation amplitude to improve balance, two sets of experiments were carried out. In the first set of experiments, all subjects received the same level of stimuli and the intensity of optimal performance was projected back on subjects' vestibular threshold curve. In the second set of experiments, on different subjects, stimulation was administered from 20-400% of subjects' vestibular threshold obtained from joystick data. Preliminary results of our study show that, in general, using stimulation amplitudes at 40-60% of perceptual motion threshold improved balance performance significantly compared to control (no stimulation). The amplitude of vestibular stimulation that improved balance function was predominantly in the range of +/- 100 to +/- 400 micro A. We hypothesize that VSR stimulation will act synergistically with sensorimotor adaptability (SA) training to improve adaptability by increasing utilization of vestibular information and therefore will help us to optimize and personalize a SA countermeasure prescription. This combination will help to significantly reduce the number of days required to recover functional performance to preflight levels after long-duration spaceflight.

Goel, R.↗

Manipulating cobalt oxide on N-doped aligned electrospun carbon nanofibers towards instant electrochemical detection of dopamine secreted by living cells

A demand exists for the development of miniaturized biosensors with high sensitivity and a wide dynamic range for rapid detecting dopamine (DA) levels. Here, an electrochemical sensor is created by decorating closely packed cobalt oxide (Co 3 O 4 ) nanograins on nitrogen-doped electrospun carbon nanofibers (NECNFs) via a facile electrodeposition method. The carbon nanofiber matrix provides both a scaffold with ultrahigh surface area for homogeneous dispersion of cobalt oxide nanostructures and facilitates the electrochemical conductivity for the hybrid electrode. The sensing principle is based on the redox reaction between DA and DA quinone that generates electrical signal, which is detectable via differential pulse voltammetry (DPV) and chronoamperometry (CA). Owing to a high electroactive surface area and facilitating electron transfer between electrode surface and the target molecule, the electrical sensing platform exhibits superior sensitivity and selectivity toward DA, with an excellent limit of detection (9 nM) over a wide range of concentrations (0.01 to 100 μM). Moreover, based on its excellent sensing properties and biocompatibility, the sensor has been used for the real-time monitoring exogeneous DA released from pheochromocytoma (PC12) cells. This work demonstrates promise of a novel sensor technology that may render rapid point-of-care testing of DA towards early clinical diagnosis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Grid Event Signature Library Analytics Report: Signature Matching Tool Development Efforts

This report describes the purpose and features of the Signature Matching Tool (SMT), employed in the Department of Energy (DOE) Grid Event Signature Library (GESL). The SMT supports a user of GESL to identify snippets of electric signatures, usually from sensor devices measuring electric characteristics such as phase voltages and currents, frequency, etc., suspected to represent certain events in the power grid but are not known to the user. The SMT uses a classification method to identify an event of the unknown signature, using the repository of known and labeled signatures in the GESL. The classifier applies a local binary classifier per node (LCN) approach to the unique event tag taxonomy used in the GESL, where training phases are separated based on the Primary labels in the taxonomy, sensor type, and voltage level. Results show that this method helps with computing time during training, in comparison to a flat, multinomial classifier, and produces acceptable average accuracy of 83% across all Primary labels. The report concludes with planned future work including integration to the web interface and API.

97 MATHEMATICS AND COMPUTING↗

Acoustic Sensing Fiber Coupled with Highly Magnetostrictive Ribbon for Small-Scale Magnetic-Field Detection

Fiber-optic sensing has shown promising development for use in detecting magnetic fields for downhole and biomedical applications. Coupling existing fiber-based strain sensors with highly magnetostrictive materials allows for a new method of magnetic characterization capable of distributed and high-sensitivity field measurements. This study investigates the strain response of the highly magnetostrictive alloys Metglas® 2605SC and Vitrovac® 7600 T70 using Fiber Bragg Grating (FBG) acoustic sensors and an applied AC magnetic field. Sentek Instrument’s picoDAS interrogated the distributed FBG sensors set atop a ribbon of magnetostrictive material, and the corresponding strain response transferred to the fiber was analyzed. Using the Vitrovac® ribbon, a minimal detectable field amplitude of 60 nT was achieved. Using Metglas®, an even better sensitivity was demonstrated, where detected field amplitudes as low as 3 nT were measured via the strain response imparted to the FBG sensor. Distributed FBG sensors are readily available commercially, easily integrated into existing interrogation systems, and require no bonding to the magnetostrictive material for field detection. The simple sensor configuration with nanotesla-level sensitivity lends itself as a promising means of magnetic characterization and demonstrates the potential of fiber-optic acoustic sensors for distributed measurements.

Dejneka, Zach (ORCID:0000000179415708)↗

Temperature compensated digital inertial sensor

A circuit which maintains the inertial element of a gyroscope or accelerometer at a constant position by delivering pulses to a rebalancing motor is discussed. The circuit compensates for temperature changes by using a temperature sensor that varies the threshold of inertial element movement required to generate a rebalance pulse which reacts to changes in viscosity of the flotation fluid. The output of the temperature sensor also varies the output level of the current source to compensate for changes in the strength of the magnets of the rebalancing motor. The sensor also provides a small signal to the rebalance motor to provide a temperature dependent compensation for fixed drift or fixed bias.

Hand, P. J.↗

Investigation of transient earth resources phenomena: Continuation study

Calculated sensitivity requirements for an earth resource satellite in a geostationary orbit are reported. Radiance levels at the satellite sensor were computed for twenty top-priority Synchronous Earth Observatory Satellite (SEOS) applications. The observation requirements were reviewed and re-evaluated in terms of spectral band definition, spectral signatures of targets and backgrounds, observation time, and site location. With these data and an atmospheric attenuation and scattering model, the total radiances observed by the SEOS sensor were calculated as were the individual components contributed by the target, target variations, and the atmosphere.

Goldman, G. C.↗

Antarctic topography from balloons

A description is presented of an investigation involving the collection of Antarctic ice sheet surface topography data by means of balloons, floating at an altitude of about 12.5 km, which traversed the Antarctic during its 1975 summer. These balloons were part of 411 constant density balloons launched in the Southern Hemisphere during the Tropical Wind, Energy conversion and Reference Level Experiment. The three sensors carried by each balloon included a radio altimeter, a pressure sensor, and an ambient temperature sensor. Data transmitted by a balloon are received by a measuring system on board the Nimbus-6 satellite. A synoptic map is presented of the 150 mbar pressure surface at 1200 GMT, December 11, 1975.

Levanon, N.↗

Synthetic aperture radar operator tactical target acquisition research

A radar target acquisition research study was conducted to access the effects of two levels of 13 radar sensor, display, and mission parameters on operator tactical target acquisition. A saturated fractional-factorial screening design was employed to examine these parameters. Data analysis computed ETA squared values for main and second-order effects for the variables tested. Ranking of the research parameters in terms of importance to system design revealed four variables (radar coverage, radar resolution/multiple looks, display resolution, and display size) accounted for 50 percent of the target acquisition probability variance.

Hershberger, M. L.↗

Noise power spectral density of the Sundstrand QA-2000 accelerometer

There are no good data on low frequency (less than 0.1 Hz) power spectral density (PSD) for the Q-Flex accelerometer. However, some preliminary stability measurements were made over periods of 12 to 24 hours and demonstrated stability less than 0.5 micro-g over greater than 12 hours. The test data appear to contain significant contributions from temperature variations at that level, so the true sensor contribution may be less than that. If what was seen could be construed as a true random process, it would correspond to about 0.1 micro-g rms over a bandwidth from 10(exp -5) Hz to about 1 Hz. Other studies of low frequency PSD in flexure accelerometers have indicated that material aging effects tend to approximate a first order Markhov process. If we combine such a model with the spectrum obtained at higher frequencies, it suggests the spectrum shown here as a conservative estimate of Q-Flex noise performance.

Peters, Rex↗