Search NASA⌕ Search

SEARCH · Search NASA

Results for “life estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Cost analysis of life sciences experiments and subsystems

Cost estimates for experiments and subsystems flown in the Spacelab were established. Ten experiments were cost analyzed. Estimated cost varied from $650,000 for the hardware development of the SPE water electrolysis experiment to $78,500,000 for the development and operation of a representative life sciences laboratory program. The cost of subsystems for thermal, atmospheric and trace contaminants control of the Spacelab internal atmosphere was also estimated. Subsystem cost estimates were based on the utilization of existing components developed in previous space programs whenever necessary.

Yakut, M. M.↗

Transmission overhaul estimates for partial and full replacement at repair

Timely transmission overhauls increase in-flight service reliability greater than the calculated design reliabilities of the individual aircraft transmission components. Although necessary for aircraft safety, transmission overhauls contribute significantly to aircraft expense. Predictions of a transmission's maintenance needs at the design stage should enable the development of more cost effective and reliable transmissions in the future. The frequency is estimated of overhaul along with the number of transmissions or components needed to support the overhaul schedule. Two methods based on the two parameter Weibull statistical distribution for component life are used to estimate the time between transmission overhauls. These methods predict transmission lives for maintenance schedules which repair the transmission with a complete system replacement or repair only failed components of the transmission. An example illustrates the methods.

Savage, M.↗

Hardware scaleup procedures for P/C life support systems

This paper compares scaleup correlations developed at the Jet Propulsion Laboratory and at the Langley Research Center for various life-support hardware to estimate mass, volume, and power-consumption values as a function of feed or product-mass flow rates. The scaleup correlations are provided for a few selected advanced life-support technologies developed for the Space Station Freedom. In addition, correlation-validity limits and sources of data on various life-support hardware are also discussed.

Naresh, Rohatgi↗

Effective Presentation of Metabolic Rate Information for Lunar Extravehicular Activity (EVA)

During human exploration of the lunar surface, a suited crewmember needs effective and accurate information about consumable levels remaining in their life support system. The information must be presented in a manner that supports real-time consumable monitoring and route planning. Since consumable usage is closely tied to metabolic rate, the lunar suit must estimate metabolic rate from life support sensors, such as oxygen tank pressures, carbon dioxide partial pressure, and cooling water inlet and outlet temperatures. To provide adequate warnings that account for traverse time for a crewmember to return to a safe haven, accurate forecasts of consumable depletion rates are required. The forecasts must be presented to the crewmember in a straightforward, effective manner. In order to evaluate methods for displaying consumable forecasts, a desktop-based simulation of a lunar Extravehicular Activity (EVA) has been developed for the Constellation lunar suite s life-support system. The program was used to compare the effectiveness of several different data presentation methods.

Mackin, Michael A.↗

Development testing of the advanced photovoltaic solar array

The latest design, fabrication and testing details of a prototype wing are discussed. Estimates of array-level performance are presented as a function of power level and solar cell technology for geosynchronous orbit (GEO) missions and solar electric propulsion missions through the Van Allen radiation belts. Design concepts are discussed that would allow the wing to be self-retractable and restowable. To date all testing has verified the feasibility and mechanical/electrical integrity of the baseline design. The beginning-of-life (BOL) specific power estimate for a nominal 10-kW (BOL) array is about 138 W/kg, with corresponding end-of-life (EOL) performance of about 93 W/kg for a 10-year GEO mission.

Stella, P. M.↗

Human Spaceflight Applications of Novel Miniature X-Ray Technologies

INTRODUCTION: Radiography (XR) has long been a cornerstone of terrestrial medical imaging, though it has not yet been used in the spaceflight environment. Medical systems for human spaceflight missions are constrained by mass, volume, and power, and until recently, XR systems have been considered too large and power-consuming for spaceflight diagnostic and therapeutic applications. However, the rise of commercial spaceflight and NASA’s refocused efforts on returning crews to the Moon for long-duration missions have introduced a higher degree of medical risk to human spaceflight and require a re-evaluation when optimizing medical system design. Over the last decade, XR devices have miniaturized while maintaining good diagnostic and therapeutic sensitivity and specificity, making new in-flight medical and non-medical XR applications a possibility. Initial research identified several medical conditions where miniature XR would be beneficial for the diagnosis and/or management of medical conditions arising in space, though a more in-depth analysis is required to identify whether XR may add value to the management of such conditions. With this presentation, we aim to introduce the potential utility of miniature XR, review prior work highlighting where XR may be beneficial, and evaluate how miniature XR may reduce medical risk in human spaceflight missions. METHODS: IMPACT (Informing Mission Planning via Analysis of Complex Tradespaces) is a risk assessment tool developed by NASA to advance exploration mission medical system design by quantitatively estimating mission medical risk. IMPACT v1.0 includes a novel evidence library baselined to exploration environments, an expanded list of 119 medical conditions, medical capabilities and resources critical for management of these medical conditions, and the ability for rapid and iterative analysis in the setting of modifiable design reference missions (DRMs). Our first analysis identified which of the 119 medical conditions XR had diagnostic or therapeutic utility for. Subject matter experts (SMEs) recorded which XR views would be performed under ideal terrestrial circumstances for diagnosis/management of each condition, as well as which views are pragmatic for spaceflight limitations. A second analysis utilized IMPACT to identify significant conditions that contribute greatest to medical risk during a notional long-duration Lunar orbit and Lunar surface DRM. Medical system risk estimates include loss of crew life (LOCL), need for return to definitive care (RTDC; medical evacuation), and an estimate of crew task time affected (TTA). Using a standardized semi-quantitative scoring methodology, a deeper evaluation of each of the most significant medical conditions was performed. Data from both of these separate analyses were used to hypothesize what ideal and pragmatic XR studies may impact clinical management of the most significant conditions predicted to lead to medical risk. RESULTS: Approximately 1/3 of the IMPACT conditions were identified as being more effectively or comprehensively assessed or treated with the addition of miniature XR technology. The resulting conditions benefitting diagnostically and therapeutically from XR are revealed, as well as the ideal and pragmatic XR views and medical procedures benefitting from XR. The conditions of clinical significance and those most contributing to risk are also displayed. Among the conditions that contribute greatest to LOCL, four conditions for which XR may improve the diagnosis and management of include: decompression sickness, traumatic shock, dental abscess, and respiratory failure. Among conditions that contributed to RTDC, the evaluation and management of wrist fracture is likely improved by XR. For conditions leading to crew TTA, evaluation and management of EVA shoulder injuries, upper and lower extremity strains, back strains, and EVA hand injuries are likely improved by XR. DISCUSSION: Miniature XR in spaceflight has the potential to improve the evaluation and management of a substantial portion of conditions that most contribute to medical risk. This presentation is an introduction to the possibilities miniature XR provides for future human spaceflight missions and subsequent presenters will expand on potential applications in more detail. LEARNING OBJECTIVES: 1) Understand the previous limitations of using radiography in the management of spaceflight medical conditions; 2) Evaluate the findings from the IMPACT tool analysis, which allows quantification of the benefit miniature XR could provide for managing high-risk medical conditions in long-duration lunar orbit and surface missions, focusing on improvements in crew health outcomes; 3) Analyze case studies where miniature XR technology could reduce the medical risks associated with spaceflight missions, specifically in diagnosing and managing conditions such as decompression sickness, traumatic shock, and EVA-related injuries.

A Anderson↗

Quantifying Medical Risk on a Long Duration Lunar Mission: A Demonstration of NASA’s IMPACT Tradespace Analysis Tool

Background NASA’s human exploration spaceflight missions to the Moon and Mars present unprecedented challenges for in-mission medical care. The distance from Earth will mean increased mission durations, communication delays, limited to no resupply opportunities, and constraints on the medical evacuation of astronauts. Mass, volume, power, and data will be limited while higher demands will be placed on the crew to manage medical care. NASA’s Moon to Mars exploration strategy lays out increasingly complex Artemis missions both in terms of duration and operations. In these more challenging deep space missions, it is important to quantitatively estimate the human medical risk to inform a traditional heuristic approach to medical risk. Prior tools have been developed for missions in low Earth orbit, but a new tool is required to plan for future exploration missions. Methods IMPACT (Informing Mission Planning via Analysis of Complex Tradespaces) is a risk assessment tool developed by NASA to advance exploration mission medical system design by quantitatively estimating mission medical risk. IMPACT v1.0 includes a novel evidence library baselined to exploration environments; an expanded list of 119 medical conditions; the addition of medical resources; and the ability for rapid and iterative analysis. Medical system risk estimates include loss of crew life, consideration of the need for return to definitive care (medical evacuation), and an estimate of crew time affected due to medical conditions. A notional long duration lunar orbit and lunar surface design reference mission (DRM) was chosen with a 4-astronaut crew to represent a sustained exploration Artemis mission. Results/Discussion Overall, IMPACT successfully quantified medical risk and derived an optimized medical system to support crew on a long duration lunar mission. In this DRM, the calculated loss of crew life from a medical event was 0.008 events per mission, risk of potential need for evacuation was 0.30 events per mission, and cumulative crew time affected by medical conditions was 103 days. The medical conditions that most contributed to overall medical risk were decompression sickness, trauma conditions, and respiratory failure. The conditions that had the largest effects on crew performance included musculoskeletal injuries and lunar dust exposure. The IMPACT-generated medical system included resources that target the most common and highest risk conditions. This systematic analysis demonstrates the value of the IMPACT tool in medical system design for human exploration spaceflight missions.

Missions to Mars↗

Quantifying Medical Risk on a Long Duration Lunar Mission: A Demonstration of NASA’s IMPACT Tradespace Analysis Tool

Background NASA’s human exploration spaceflight missions to the Moon and Mars present unprecedented challenges for in-mission medical care. The distance from Earth will mean increased mission durations, communication delays, limited to no resupply opportunities, and constraints on the medical evacuation of astronauts. Mass, volume, power, and data will be limited while higher demands will be placed on the crew to manage medical care. NASA’s Moon to Mars exploration strategy lays out increasingly complex Artemis missions both in terms of duration and operations. In these more challenging deep space missions, it is important to quantitatively estimate the human medical risk to inform a traditional heuristic approach to medical risk. Prior tools have been developed for missions in low Earth orbit, but a new tool is required to plan for future exploration missions. Methods IMPACT (Informing Mission Planning via Analysis of Complex Tradespaces) is a risk assessment tool developed by NASA to advance exploration mission medical system design by quantitatively estimating mission medical risk. IMPACT v1.0 includes a novel evidence library baselined to exploration environments; an expanded list of 119 medical conditions; the addition of medical resources; and the ability for rapid and iterative analysis. Medical system risk estimates include loss of crew life, consideration of the need for return to definitive care (medical evacuation), and an estimate of crew time affected due to medical conditions. A notional long duration lunar orbit and lunar surface design reference mission (DRM) was chosen with a 4-astronaut crew to represent a sustained exploration Artemis mission. Results/Discussion Overall, IMPACT successfully quantified medical risk and derived an optimized medical system to support crew on a long duration lunar mission. In this DRM, the calculated loss of crew life from a medical event was 0.008 events per mission, risk of potential need for evacuation was 0.30 events per mission, and cumulative crew time affected by medical conditions was 103 days. The medical conditions that most contributed to overall medical risk were decompression sickness, trauma conditions, and respiratory failure. The conditions that had the largest effects on crew performance included musculoskeletal injuries and lunar dust exposure. The IMPACT-generated medical system included resources that target the most common and highest risk conditions. This systematic analysis demonstrates the value of the IMPACT tool in medical system design for human exploration spaceflight missions.

Missions to Mars↗

Remaining Life Determination

This project developed and demonstrated the capability of nondestructive evaluation methods for detecting early stage fatigue damage in grey cast iron metal. Non-collinear ultrasonic wave mixing and laser speckle differentiation were the primary technologies evaluated on custom fatigue specimens having properties specified by Caterpillar, Inc. The ultrasonic method showed the greatest potential for estimating the remaining fatigue life in grey cast iron, which may provide remanufacturers with a level of confidence when fielding used component cores in high-stress applications. While successes were realized during this project, there are still follow-on research tasks required to prove the commercial applicability of the methods. The following report sections document the steps completed during the project and an assessment of the technologies applied.

36 MATERIALS SCIENCE↗

Quantifying Risk to Improve Medical System Design for Long Duration Artemis Missions: A Demonstration of NASA's IMPACT Tradespace Analysis Tool

BACKGROUND NASA’s human exploration spaceflight missions to the Moon and Mars present unprecedented challenges for in-mission medical care. A greater distance from Earth will mean increased mission durations, communication delays, limited to no resupply opportunities, and constraints on the evacuation of ill or injured crew. Mass, volume, and power will be limited while higher demands will be placed on the crews to manage medical events. NASA’s Moon to Mars exploration strategy outlines increasingly complex Artemis missions both in terms of duration and operations. In these more challenging deep space missions, it is important to quantitatively estimate the human system risk attributable to medical conditions and use these estimates to advance medical system design. METHODS IMPACT (Informing Mission Planning via Analysis of Complex Tradespaces) is a probabilistic risk assessment (PRA) and tradespace analysis tool developed by NASA to advance exploration mission medical system design. IMPACT v1.0 includes a novel evidence library baselined to exploration environments; an expanded list of 119 medical conditions; a large increase in the number of medical resources and the flexibility of their use; and the ability for rapid and iterative analysis. Medical system risk estimates include loss of crew life, consideration of the need for return to definitive care (medical evacuation), and an estimate of crew time affected due to medical conditions. A notional long duration lunar orbit and lunar surface design reference mission (DRM) was chosen with a 4-astronaut crew to mimic a foundational exploration Artemis mission. The DRM profile includes outbound transit on Orion, Gateway space station rendezvous in lunar orbit, 6 months on the Lunar surface with extravehicular activity (EVA), return rendezvous with Gateway, and transit back to Earth. RESULTS/DISCUSSION: Overall, IMPACT successfully quantified medical risk and derived an optimal medical system to support crew on a long duration lunar mission. In this DRM, the calculated loss of crew life from a medical event was 0.008 events per mission, risk of potential need for evacuation was 0.30 events per mission, and cumulative crew time affected by medical conditions was 103 days. The medical conditions that most contributed to medical risk were decompression sickness, trauma, and respiratory failure. The conditions that had the largest effects on crew performance included musculoskeletal injuries and lunar dust exposure. The IMPACT-generated medical system included resources that target the most common and highest risk conditions and performed as expected. This demonstrates the value of the IMPACT tool in medical system design for human exploration spaceflight missions.

Arian Anderson↗

Analysis of Air-Purifying Respirator (APR) and Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on a Hanford AX Tank Farm Exhauster Slipstream Volume 1

Washington River Protection Solutions (WRPS) conducted tests of four types of chemical cartridges for air-purifying respirators (APR) and powered air-purifying respirators (PAPR) to determine the period of time the cartridges would provide adequate performance1 for APRs and PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPCs) from vapors exiting the Hanford AX tank farm exhauster slipstream. The Occupational Safety and Health Administration (OSHA) considers cartridge testing to be a valid approach for establishing a cartridge service life. Testing is applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Cartridge testing using vapors from a Hanford AX tank farm exhauster slipstream was conducted from August 25–27, 2017. Vapors from the exhauster slipstream were fed to two respirator cartridge test stands developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Four different cartridges were assessed. Multipurpose APR cartridges—SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina)—were assessed on separate days using an APR cartridge test stand. Multipurpose PAPR cartridges—MSA-TL (TL1) (MSA Safety Inc., Pittsburgh, Pennsylvania) and 3M FR57 (TL2) (3M Company, Maplewood, Minnesota)—also were tested over the same two days using a separate PAPR cartridge test stand. Sample media (i.e., sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridges and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life. The key conclusions from the analysis are described below.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Machine Learning Based Metamodel for Faster Life Cycle Assessment of Large Portfolio of Buildings

Managing a large portfolio of buildings involves decisions on reuse, retrofit, renovation, rehabilitation, and new construction, influenced by trade-offs between performance metrics such as cost, time, and operational flexibility over the building's life cycle. Traditional life cycle assessment tools for evaluating these metrics can be labor- and compute-intensive, requiring extensive data and modeling for each building. Metamodels (or surrogate models) using machine learning have been explored as faster alternatives, but training these models has been hindered by the limited availability of comprehensive data on key life cycle metrics. Recent advancements in machine learning, particularly deep learning techniques like zero-shot and few-shot learning, allow models to learn from sparse or limited data. We propose a machine learning-based metamodel that leverages these techniques for rapid estimation of key building life cycle metrics. This presentation will cover the model architecture, data collection, training, and validation processes, along with an ongoing case study applied to a large portfolio of buildings. We will discuss the model's performance in terms of accuracy, compute time, limitations, and its potential for expanding to additional life cycle metrics. This data-driven approach offers a promising direction for the rapid evaluation of large building portfolios.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Deep space network software cost estimation model

A parametric software cost estimation model prepared for Deep Space Network (DSN) Data Systems implementation tasks is presented. The resource estimation model incorporates principles and data from a number of existing models. The model calibrates task magnitude and difficulty, development environment, and software technology effects through prompted responses to a set of approximately 50 questions. Parameters in the model are adjusted to fit DSN software life cycle statistics. The estimation model output scales a standard DSN Work Breakdown Structure skeleton, which is then input into a PERT/CPM system, producing a detailed schedule and resource budget for the project being planned.

Tausworthe, R. C.↗

Preliminary Medical Risk Estimates and Clinical Capability Needs for Artemis IV

BACKGROUND Human exploration spaceflight missions to the Moon and Mars present unprecedented challenges for in- mission medical care. Compared with the ISS, the greater distance from Earth will mean increased mission durations, communication delays, limited to no resupply opportunities, and significant limitations on the evacuation of ill or injured crew. Spacecraft mass, volume, and power will be curtailed while higher demands will be placed on the crew’s knowledge, skills, and abilities. In this higher risk environment, it is important to: a) quantitatively estimate human system risk attributable to medical conditions, a process known as Probabilistic Risk Analysis, and b) use these estimates to inform medical system design. IMPACT (Informing Mission Planning via Analysis of Complex Tradespaces) is a PRA and medical trade space analysis tool developed by NASA to advance exploration mission medical system design. IMPACT v1.0 improves upon and will soon replace NASA’s existing tool, the Integrated Medical Model, with: a novel evidence base baselined to exploration environments; an expanded list of 119 medical conditions; a significant increase in the number of medical resources that can be utilized and in the flexibility of their use; and the modelling of time lost performing mission-specific tasks due to medical conditions. METHODOLOGY: This abstract will present IMPACT estimates of medical system risk and clinical capability needs for the Artemis IV mission. Artemis IV is currently scheduled for 2026 and will visit the Gateway space station in lunar orbit prior to the second lunar landing of the Artemis program. The baseline Artemis IV mission that was modeled was 28 days in duration with phases including Orion outbound, 4 days on the Gateway space station in lunar orbit, 2 crew on the surface of the Moon for approximately one week, an additional 5 days on Gateway, and then return to Earth. This baseline was compared to two alternative 34-day design reference missions (DRMs) that shifted the lunar sortie earlier or later in the mission profile. Assumptions included 2 female and 2 male crew and a notional medical system mass of 25 kg. Medical system risk estimates include loss of crew life (LOCL), consideration of medical evacuation (known as return to definitive care – RTDC), and an estimate of crew time lost due to medical conditions (Task Time Lost – TTL). The presentation will also describe the medical conditions that are the greatest drivers of risk as well as the clinical capabilities and resources that have the largest effect on risk. RESULTS: All three DRMs had very low probability of LOCL from medical conditions, primarily due to short duration. RTDC was also similar across the DRMs. In contrast, TTL was higher in the early lunar sortie DRM due to earlier occurrence of EVA-related medical conditions. Taken as a whole, there was no clinically significant difference in medical risk across the three missions. Results for clinical capabilities and an example medical equipment list will be discussed but were similar across DRMs.

D Hilmers↗

Medical Risk Estimates and Clinical Capability Needs for A Long Duration Artemis Mission

BACKGROUND Human exploration spaceflight missions to the Moon and Mars present unprecedented challenges for in-mission medical care. Compared with the ISS, the greater distance from Earth will mean increased mission durations, communication delays, limited to no resupply opportunities, and significant limitations on the evacuation of ill or injured crew. Spacecraft mass, volume, and power will be curtailed while higher demands will be placed on the crew’s knowledge, skills, and abilities. In this higher risk environment, it is important to: a) quantitatively estimate human system risk attributable to medical conditions, a process known as Probabilistic Risk Analysis, and b) use these estimates to inform medical system design. IMPACT (Informing Mission Planning via Analysis of Complex Tradespaces) is a PRA and medical trade space analysis tool developed by NASA to advance exploration mission medical system design. IMPACT v1.0 improves upon and will soon replace NASA’s existing tool, the Integrated Medical Model, with: a novel evidence base baselined to exploration environments; an expanded list of 119 medical conditions; a significant increase in the number of medical resources that can be utilized and in the flexibility of their use; and the modelling of time lost performing mission-specific tasks due to medical conditions. DISCUSSION: This abstract will present IMPACT estimates of medical system risk and clinical capability needs for an extended duration Artemis mission of approximately 9 months, with phases including outbound transit, 3 months on the Lunar Gateway space station, 3 months on the Lunar surface with EVAs, 3 months on Gateway (simulating the return phase of a Mars mission), and transit back to Earth. Medical system risk estimates include loss of crew life (LOCL), consideration of medical evacuation (known as return to definitive care – RTDC), and an estimate of crew time lost due to medical conditions (Task Time Lost – TTL). The presentation will also describe the medical conditions that are the greatest drivers of risk as well as the clinical capabilities and resources that have the largest effect on risk.

W Thompson↗

Medical Risk Estimates and Clinical Capability Needs for a Late Artemis Mission

BACKGROUND Human exploration spaceflight missions to the Moon and Mars present unprecedented challenges for in-mission medical care. Compared with the ISS, the greater distance from Earth will mean increased mission durations, communication delays, limited to no resupply opportunities, and significant limitations on the evacuation of ill or injured crew. Spacecraft mass, volume, and power will be curtailed while higher demands will be placed on the crew’s knowledge, skills, and abilities. In this higher risk environment, it is important to: a) quantitatively estimate human system risk attributable to medical conditions, a process known as Probabilistic Risk Analysis, and b) use these estimates to inform medical system design. IMPACT (Informing Mission Planning via Analysis of Complex Tradespaces) is a PRA and medical trade space analysis tool developed by NASA to advance exploration mission medical system design. IMPACT v1.0 improves upon and will soon replace NASA’s existing tool, the Integrated Medical Model, with: a novel evidence base baselined to exploration environments; an expanded list of 119 medical conditions; a significant increase in the number of medical resources that can be utilized and in the flexibility of their use; and the modelling of time lost performing mission-specific tasks due to medical conditions. DISCUSSION: This abstract will present IMPACT estimates of medical system risk and clinical capability needs for an extended duration Artemis mission of approximately 9 months, with phases including outbound transit, 3 months on the Lunar Gateway space station, 3 months on the Lunar surface with EVAs, 3 months on Gateway (simulating the return phase of a Mars mission), and transit back to Earth. Medical system risk estimates include loss of crew life (LOCL), consideration of medical evacuation (known as return to definitive care –RTDC), and an estimate of crew time list due to medical conditions (Task Time Lost –TTL). The presentation will also describe the medical conditions that are the greatest drivers of risk as well as the clinical capabilities and resources that have the largest effect on risk.

A Anderson↗

Preliminary Medical Risk Estimates and Clinical Capability Needs for Late Artemis Missions

BACKGROUND Human exploration spaceflight missions to the Moon and Mars present unprecedented challenges for in- mission medical care. Compared with the ISS, the greater distance from Earth will mean increased mission durations, communication delays, limited to no resupply opportunities, and significant limitations on the evacuation of ill or injured crew. Spacecraft mass, volume, and power will be curtailed while higher demands will be placed on the crew’s knowledge, skills, and abilities. In this higher risk environment, it is important to: a) quantitatively estimate human system risk attributable to medical conditions, a process known as Probabilistic Risk Analysis, and b) use these estimates to inform medical system design. IMPACT (Informing Mission Planning via Analysis of Complex Tradespaces) is a PRA and medical trade space analysis tool developed by NASA to advance exploration mission medical system design. IMPACT v1.0 improves upon and will soon replace NASA’s existing tool, the Integrated Medical Model, with: a novel evidence base baselined to exploration environments; an expanded list of 119 medical conditions; a significant increase in the number of medical resources that can be utilized and in the flexibility of their use; and the modelling of time lost performing mission-specific tasks due to medical conditions. METHODOLOGY: This abstract will present IMPACT estimates of medical system risk and clinical capability needs for the Artemis IV mission. Artemis IV is currently scheduled for 2026 and will visit the Gateway space station in lunar orbit prior to the second lunar landing of the Artemis program. The baseline Artemis IV mission that was modeled was 28 days in duration with phases including Orion outbound, 4 days on the Gateway space station in lunar orbit, 2 crew on the surface of the Moon for approximately one week, an additional 5 days on Gateway, and then return to Earth. This baseline was compared to two alternative 34-day design reference missions (DRMs) that shifted the lunar sortie earlier or later in the mission profile. Assumptions included 2 female and 2 male crew and a notional medical system mass of 25 kg. Medical system risk estimates include loss of crew life (LOCL), consideration of medical evacuation (known as return to definitive care – RTDC), and an estimate of crew time lost due to medical conditions (Task Time Lost – TTL). The presentation will also describe the medical conditions that are the greatest drivers of risk as well as the clinical capabilities and resources that have the largest effect on risk. RESULTS: All three DRMs had very low probability of LOCL from medical conditions, primarily due to short duration. RTDC was also similar across the DRMs. In contrast, TTL was higher in the early lunar sortie DRM due to earlier occurrence of EVA-related medical conditions. Taken as a whole, there was no clinically significant difference in medical risk across the three missions. Results for clinical capabilities and an example medical equipment list will be discussed but were similar across DRMs.

D. Hilmers↗

Reliability and Confidence Interval Analysis of a CMC Turbine Stator Vane

High temperature ceramic matrix composites (CMC) are being explored as viable candidate materials for hot section gas turbine components. These advanced composites can potentially lead to reduced weight, enable higher operating temperatures requiring less cooling and thus leading to increased engine efficiencies. However, these materials are brittle and show degradation with time at high operating temperatures due to creep as well as cyclic mechanical and thermal loads. In addition, these materials are heterogeneous in their make-up and various factors affect their properties in a specific design environment. Most of these advanced composites involve two- and three-dimensional fiber architectures and require a complex multi-step high temperature processing. Since there are uncertainties associated with each of these in addition to the variability in the constituent material properties, the observed behavior of composite materials exhibits scatter. Traditional material failure analyses employing a deterministic approach, where failure is assumed to occur when some allowable stress level or equivalent stress is exceeded, are not adequate for brittle material component design. Such phenomenological failure theories are reasonably successful when applied to ductile materials such as metals. Analysis of failure in structural components is governed by the observed scatter in strength, stiffness and loading conditions. In such situations, statistical design approaches must be used. Accounting for these phenomena requires a change in philosophy on the design engineer s part that leads to a reduced focus on the use of safety factors in favor of reliability analyses. The reliability approach demands that the design engineer must tolerate a finite risk of unacceptable performance. This risk of unacceptable performance is identified as a component's probability of failure (or alternatively, component reliability). The primary concern of the engineer is minimizing this risk in an economical manner. The methods to accurately determine the service life of an engine component with associated variability have become increasingly difficult. This results, in part, from the complex missions which are now routinely considered during the design process. These missions include large variations of multi-axial stresses and temperatures experienced by critical engine parts. There is a need for a convenient design tool that can accommodate various loading conditions induced by engine operating environments, and material data with their associated uncertainties to estimate the minimum predicted life of a structural component. A probabilistic composite micromechanics technique in combination with woven composite micromechanics, structural analysis and Fast Probability Integration (FPI) techniques has been used to evaluate the maximum stress and its probabilistic distribution in a CMC turbine stator vane. Furthermore, input variables causing scatter are identified and ranked based upon their sensitivity magnitude. Since the measured data for the ceramic matrix composite properties is very limited, obtaining a probabilistic distribution with their corresponding parameters is difficult. In case of limited data, confidence bounds are essential to quantify the uncertainty associated with the distribution. Usually 90 and 95% confidence intervals are computed for material properties. Failure properties are then computed with the confidence bounds. Best estimates and the confidence bounds on the best estimate of the cumulative probability function for R-S (strength - stress) are plotted. The methodologies and the results from these analyses will be discussed in the presentation.

Murthy, Pappu L. N.↗