Search NASA⌕ Search

SEARCH · Search NASA

Results for “long term testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

In Situ Reliability Investigation of All-Vanadium Redox Flow Batteries by a Stable Reference Electrode

Redox flow batteries (RFBs) have been studied over the past several decades as a promising candidate for stationary energy storage applications. It is therefore important to understand the reliability of RFBs and the mechanisms that cause degradation with time. Contributions from individual electrodes (cathode or anode) are difficult to separate especially for long-term cycle testing, due to the lack of a stable reference electrode. In our work, the reliability and degradation mechanisms of an all-vanadium RFB were investigated by a stable reference electrode based on the dynamic hydrogen electrode (DHE). With factor exploration and design optimization, the newly developed DHE reference electrode demonstrated high accuracy and long-term stability that enables in-situ monitoring of individual electrode signals (potentials and impedances) over hundreds of cycles in a vanadium RFB. This approach enables the full cell degradation to be separated and the degradation attributed to contributions from the cathode and anode. The cathode and anode were found to play quite different roles in the increase in overpotential of the vanadium RFB during long-term cycling. The anode reaction limited both the charge and discharge capacity over 100 cycles. In addition, the negative side also appeared to be the rate limiting factor throughout cycling as determined by EIS measurement. The cathode contributed to the performance degradation as cycling exceeded 50 cycles.

Huang, Qian↗

New observational evidence for a positive cloud feedback that amplifies the Atlantic Multidecadal Oscillation

Abstract The Atlantic Multidecadal Oscillation (AMO) affects climate variability in the North Atlantic basin and adjacent continents with potential societal impacts. Previous studies based on model simulations and short‐term satellite retrievals hypothesized an important role for cloud radiative forcing in modulating the persistence of the AMO in the tropics, but this mechanism remains to be tested with long‐term observational records. Here we analyze data sets that span multiple decades and present new observational evidence for a positive feedback between total cloud amount, sea surface temperature (SST), and atmospheric circulation that can strengthen the persistence and amplitude of the tropical branch of the AMO. In addition, we estimate cloud amount feedback from observations and quantify its impact on SST with idealized modeling experiments. From these experiments we conclude that cloud feedbacks can account for 10% to 31% of the observed SST anomalies associated with the AMO over the tropics.

Bellomo, Katinka↗

Total Reducing Capacity in Aquifer Minerals and Sediments: Quantifying the Potential to Attenuate Cr(VI) in Groundwater

Hexavalent chromium, Cr(VI), is present in the environment as a byproduct of industrial processes. Due to its mobility and toxicity, it is crucial to attenuate or remove Cr(VI) from the environment. The objective of this investigation was to quantify potential natural attenuation, or reduction capacity, of reactive minerals and aquifer sediments. Samples of reduced-iron containing minerals such as ilmenite, as well as Puye Formation sediments representing a contaminated aquifer in New Mexico, were reacted with chromate. The change in Cr(VI) during the reaction was used to calculate reduction capacity. This study found that minerals that contain reduced iron, such as ilmenite, have high reducing capacities. The data indicated that sample history may impact reduction capacity tests due to surface passivation. Further, this investigation identified areas for future research including: a) refining the relationships between iron content, magnetic susceptibility and reduction capacity, and b) long term kinetic testing using fresh aquifer sediments.

54 ENVIRONMENTAL SCIENCES↗

SPR Hydrostatic Column Model Verification and Validation.

A Hydrostatic Column Model (HCM) was developed to help differentiate between normal "tight" well behavior and small-leak behavior under nitrogen for testing the pressure integrity of crude oil storage wells at the U.S. Strategic Petroleum Reserve. This effort was motivated by steady, yet distinct, pressure behavior of a series of Big Hill caverns that have been placed under nitrogen for extended period of time. This report describes the HCM model, its functional requirements, the model structure and the verification and validation process. Different modes of operation are also described, which illustrate how the software can be used to model extended nitrogen monitoring and Mechanical Integrity Tests by predicting wellhead pressures along with nitrogen interface movements. Model verification has shown that the program runs correctly and it is implemented as intended. The cavern BH101 long term nitrogen test was used to validate the model which showed very good agreement with measured data. This supports the claim that the model is, in fact, capturing the relevant physical phenomena and can be used to make accurate predictions of both wellhead pressure and interface movements.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Hydrogen Production and Purification from Coal and Other Heavy Feedstocks Year 6 - Activity 1.4 - Development of a National Center for Hydrogen Technology

Air Products and Chemicals, Inc., is developing the sour pressure swing adsorption (PSA) technology which can be used to reject acid gas components (hydrogen sulfide [H 2 S] and carbon dioxide [H 2 S]) from sour syngas streams such as coal gasification syngas. In the current work, tests were conducted to investigate the impact of continuous exposure of real sour syngas and dilute levels of hydrochloric acid (HCl) and ammonia (NH 3 ) on the preferred adsorbent of that process. The results show a modest (~10%–15%) decrease in CO 2 adsorption capacity after sour syngas exposure, as well as deposition of metals from carbonyl decomposition. Continuous exposure to HCl and NH 3 yield a higher degree of CO 2 capacity degradation (up to 25%). These tests represent worst-case approaches since the exposure is continuous and the HCl and NH 3 levels are relatively high compare to an industrial sour syngas stream. Long-term PSA tests are needed to unequivocally evaluate the impact of cyclic exposure to these types of streams.

01 COAL, LIGNITE, AND PEAT↗

Large area sheet task: Advanced Dendritic Web Growth Development

A melt level control system was implemented to provide stepless silicon feed rates from zero to rates exactly matching the silicon consumed during web growth. Bench tests of the unit were successfully completed and the system mounted in a web furnace for operational verification. Tests of long term temperature drift correction techniques were made; web width monitoring seems most appropriate for feedback purposes. A system to program the initiation of the web growth cycle was successfully tested. A low cost temperature controller was tested which functions as well as units four times as expensive.

Duncan, C. S.↗

Petrophysical and geomechanical properties of gas hydrate-bearing sediments recovered from Alaska North Slope 2018 Hydrate-01 Stratigraphic Test Well

Knowledge of petrophysical and geomechanical properties of gas hydrate-bearing sediments are essential for predicting reservoir response due to gas production from gas hydrate reservoirs. That information will be critical parameters for designing production well completion such as specification of depressurization pump, water storage tank, and mesh size of sand screen. In December 2018, Stratigraphic Test Well Hydrate-01 was drilled in the western part of the Prudhoe Bay Unit, Alaska North Slope as part of the technical planning effort for a future long-term production test by collaborative team of DOE/NETL, USGS, and MH21-S (Boswell et al., 2020, Collett et al., 2020, Okinaka et al., 2020). Data set of logging-while-drilling (LWD) were acquired (Haines et al., 2020, Suzuki et al., 2019) and core sampling depth was determined on-site.Side-wall pressure coring was conducted to recover gas hydrate-bearing sediments from two reservoir sections named Unit-B and Unit-D. A total of 34 cores were successfully recovered by 5 runs of a wire-line deployed pressure corer (CoreVault® System - Halliburton). Core analysis scheme of this project are shown in Figure 1. All cores were quenched in liquid nitrogen while at high pressure in the laboratory of Stratum Reservoir, LLC. at Anchorage (Figure 1, a)). And the cores were removed from the pressure corer autoclave with temperature support of dry ice and stored under liquid nitrogen at atmospheric pressure. 19 damaged cores were processed to index property measurements directly such as grain size, grain density. 4 of another 17 cores were depressurized and trimmed for making a plug to analyze petrophysical properties of host sediments. Unsteady-state permeability test was conducted to obtain relative water permeability to gas and core scale NMR T2 distribution measurement was performed for evaluating pore size distribution at Houston (Figure 1, b)). Remained high quality 13 cores were preserved with gas hydrate for advanced laboratory analysis. National Institute of Advanced Industrial Science and Technology, as a part of the Japanese National Hydrate Research Program (MH21-S, funded by Ministry of Economy, Trade and Industry), received the samples at Sapporo, Japan for advanced core analysis. High-resolution X-ray CT was used to analyze the quality of the samples, which showed undisturbed lithological layers. Cores were lathed into cylindrical shape and distributed for multi property measurements (Figure 1, c)).<p>As a result, sediment from Unit-D is categorized as silty sand at ~37% porosity with ~80% gas hydrate saturation. An average hydration number n = 6.16 was measured by Raman spectroscopy. An average intrinsic permeability of ~400 mD and in situ effective permeability (with hydrate) on the order of ~10 mD. The Unit B recovered cores consisted of well sorted sand at ~40% porosity with ~95% gas hydrate saturation. An average intrinsic permeability of ~1 Darcy and in situ effective permeability on the order of ~30 mD was measured for the Unit B cores. There was a small permeability reduction due to porosity loss with increasing effective stress that simulated consolidation behavior along with depressurization in the highly permeable sandy sediment. The apparent minimum change in porosity and permeability may be caused by the low compressibility of quartz sand grains in the recovered cores. XRD and thermal conductivity analysis also suggested high quartz content. Triaxial compression tests established internal friction angles based on the Mohr-Coulomb's failure criterion, which are 40° for hydrate-bearing sediment and 29.8° for hydrate free sediment.</p>

Yoneda, Jun↗

Mineral Scaling in 3D Interfacial Solar Evaporators–A Challenge for Brine Treatment and Lithium Recovery

In this work, we analyzed the effects of mineral scaling on the performance of a 3D interfacial solar evaporator, with a focus on the cations relevant to lithium recovery from brackish water. The field has been rapidly moving toward resource recovery applications from brines with higher cation concentrations. However, the potential complications caused by common minerals in these brines other than NaCl have been largely overlooked. Therefore, in this study, we thoroughly examined the effects of two common cations (calcium and magnesium) on the long-term solar evaporation performance of a 3D graphene oxide stalk. The 3D stalk can achieve an evaporation flux as high as 17.8 kg m –2 h –1 under one-sun illumination, and accumulation of NaCl on the stalk surface has no impact. However, the presence of CaCl 2 and MgCl 2 significantly reduces the evaporative flux even in solutions lacking scale-forming anions. A close examination of scale formation during long-term evaporation experiments revealed that CaCl 2 and MgCl 2 tend to precipitate out within the stalk, thus blocking water transport through the stalk and significantly dropping the evaporation rates. These findings imply that research attention is needed to modify and optimize the internal water transport channels for 3D evaporators. Additionally, we emphasize the importance of testing realistic mixtures–including prominent divalent cations– and testing long-term operations in interfacial solar evaporation research and investigating approaches to mitigate the negative impacts of divalent cations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Strapdown gyro test program

The power spectral noise characteristic performance of the Teledyne two-degree-of-freedom dry tuned gimbal gyroscope was determined. Tests were conducted using a current configuration SDG-5 gyro in conjunction with test equipment with minor modification. Long term bias stability tests were conducted as well as some first difference performance tests. The gyro, test equipment, and the tests performed are described. Results are presented.

Irvine, R. B.↗

Implementation of Research and Development (R and D) Results in the Design of Liner System for the Near Surface Disposal Facility (NSDF) - 19089

Canadian Nuclear Laboratories (CNL) proposes to develop a Near Surface Disposal Facility (NSDF) at the Chalk River Laboratories (CRL) site in Ontario, Canada for disposal of CNL's Low Level Radioactive Waste (LLW) and other suitable wastes meeting the Waste Acceptance Criteria (WAC). The NSDF's Engineered Containment Mound (ECM) includes base liner and final cover systems. These liner systems are designed to perform effectively for a total of 550 years. The specified geomembrane in the NSDF detailed design is 2 mm thick High Density Polyethylene Geomembrane (HDPE GMB) double sided textured and white surface. CNL's approach to collaborate with Subject Matter Expert (SME) consultants and contractors, a Canadian university, and industry has enabled the NSDF to incorporate current best design practices, particularly for the design of the ECM's liner systems. This paper describes the HDPE GMB testing program and how the results of the state-of-the-art research have been utilized in the design of the NSDF's liner system and in selection of the best candidate materials to strengthen the confidence that the required service-life will be met. The testing program includes index properties and long-term performance evaluation tests of the five candidate HDPE GMBs using leachate simulant comparable to expected NSDF leachate and an index simulant used for testing many GMBs. The results of the tests are used as the basis to assess expected HDPE GMBs long-term performance. The expected long-term performance is applied as the key consideration for the final selection of the HDPE GMB in the NSDF project. Preliminary results of the testing program indicate that an expected service-life of 550 years will likely be met by the candidate HDPE GMB. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Stirling Research Laboratory Providing Independent Performance Verification of Convertors for a Stirling Radioisotope Generator

The Department of Energy (DOE), Germantown, Maryland, Stirling Technology Company (STC), Kennewick, Washington, and NASA Glenn Research Center are developing a free-piston Stirling convertor for a high-efficiency Stirling Radioisotope Generator for NASA Space Science missions. This generator is being developed for multimission use, including providing electric power for unmanned Mars rovers and for deep space missions. STC is developing the 55-W Technology Demonstration Convertor (TDC) under contract to DOE. Glenn is conducting an in-house technology project to assist in developing the convertor for readiness for space qualification and mission implementation. As part of this effort, a Stirling Research Laboratory was established to test the TDC's and related technologies. A key task is providing an independent verification and validation of the TDC performance. Four TDC's are now being tested at Glenn. Acceptance testing has been completed for all convertors, and in general, performance agreed well with that achieved by STC prior to the delivery of the convertors. Performance mapping has also been completed on two of the convertors over a range of hot-end temperatures (450 to 650 C), cold-end temperatures (80 to 120 C), and piston amplitudes (5.2 to 6.2 mm). These test data are available online at http://www.grc.nasa.gov/WWW/tmsb/. The TDC's can be tested in either a horizontal orientation with dual-opposed convertors or in a vertical orientation with a single convertor. Synchronized dual-opposed pairs are used for dynamically balanced operation that results in very low levels of vibration. The Stirling Research Laboratory also supports launch environment testing of the TDC's in Glenn's Structural Dynamics Laboratory and electromagnetic interference and electromagnetic compatibility characterization and reduction efforts. In addition, the TDC's will be used for long-term endurance testing, and preparations are underway for unattended operation.

Thieme, Lanny G.↗

Application of Sol-Gel Method as a Protective Layer on a Specular Reflective Surface for Secondary Reflector in a Solar Receiver

Highly-specular reflective surfaces that can withstand elevated-temperatures are desirable for many applications including reflective heat shielding in solar receivers and secondary reflectors, which can be used between primary concentrators and heat collectors. A high-efficiency, high-temperature solar receiver design based on arrays of cavities needs a highly-specular reflective surface on its front section to help sunlight penetrate into the absorber tubes for effective flux spreading. Since this application is for high-temperature solar receivers, this surface needs to be durable and to maintain its optical properties through the usable life. Degradation mechanisms associated with elevated temperatures and thermal cycling, which include cracking, delamination, corrosion/oxidation, and environmental effects, could cause the optical properties of surfaces to degrade rapidly in these conditions. Protected mirror surfaces for these applications have been tested by depositing a thin layer of SiO2 on top of electrodeposited silver by means of the sol-gel method. To obtain an effective thin film structure, this sol-gel procedure has been investigated extensively by varying process parameters that affect film porosity and thickness. Endurance tests have been performed in a furnace at 150 degrees C for thousands of hours. This paper presents the sol-gel process for intermediate-temperature specular reflective coatings and provides the long-term reliability test results of sol-gel protected silver-coated surfaces.

14 SOLAR ENERGY↗

Stable perovskite-fluorite dual-phase composites synthesized by one-pot solid-state reactive sintering for protonic ceramic fuel cells

We report that this work synthesized a series of oxide composites with nominal compositions of BaCe 05 Zr 0.4 Y 0.1 O 3-δ (BCZY)-Ce 0.5 Y 0.5 O 2-δ (YDC) based on the BCZY/YDC molar ratios of 0.5:1, 1:1, 2:1, and 4:1 (BCZY-YDC-0.5–1, BCZY-YDC-1-1, BCZY-YDC-2-1, and BCZY-YDC-4-1) using a one-pot solid state reactive sintering (SSRS) method. The X-ray diffraction (XRD) patterns and refinement proved that the one-pot SSRS at 1450 °C for 12 h could achieve the perovskite-fluorite dual-phase composites (DPCs) with the desired structure compositions. The scanning electron microscopy (SEM) images showed that the two DPCs of BCZY-YDC-1-1 and BCZY-YDC-2-1 formed excellent percolation for perovskite and fluorite phases. The conductivity measurement by electrochemical impedance spectroscopy (EIS) and the transference number measurement by the electromotive force (EMF) test proved that changing the BCZY/YDC molar ratio and operating condition could adjust the DPC's conduction property to make them suitable for electrolytes and electrode scaffolds for protonic ceramic fuel cells (PCFCs). The long-term conductivity testing and the crystal structure analysis after EMF testing under versatile conditions indicated that the DPCs of BCZY-YDC-2-1 and BCZY-YDC-1-1 were durable PCFC component materials. The PCFC button cells with the as-discovered BCZY-YDC-2-1 and BCZY-YDC-1-1 as an electrolyte and an anode scaffold, respectively, and the reported Ba–Ce–Fe–Co–O perovskite-perovskite composite as a cathode showed promising performance under H 2 /air gradient.

08 HYDROGEN↗

Diesel fuel long term storage and treatment- recommended tests and practices (U)

The Clean Air Act (1970) is the comprehensive federal law that regulates air emissions from stationary and mobile sources. Among other things, this law authorized the Environmental Protection Agency (EPA) to establish National Ambient Air Quality Standards to protect public health and public welfare and to regulate emissions of hazardous air pollutants. In recent years, EPA regulations have forced oil refineries into producing a very low sulfur diesel fuel and incentives for adding up to 5% bio-diesel. These changes to the fuel oil formulation are beneficial to air quality and to energy conservation, but adversely impact heat content, long term storage stability, engine power, and injection system reliability. Diesel engines typically have a high incidence of injector failure resulting from poor diesel fuel quality. Since standby diesel engines do not run continuously it is necessary to implement periodic surveillance's to ensure the quality of diesel fuel is acceptable for reliable operation when a loss of power occurs. The information contained in this document is a compilation of best practices to be used as a guide for maintenance of a reliable diesel fuel system.

54 ENVIRONMENTAL SCIENCES↗

A groundwater flow and transport model of long-term radionuclide migration in central Frenchman flat, Nevada test site

A set of groundwater flow and transport models were created for the Central Testing Area of Frenchman Flat at the former Nevada Test Site to investigate the long-term consequences of a radionuclide migration experiment that was done between 1975 and 1990. In this experiment, radionuclide migration was induced from a small nuclear test conducted below the water table by pumping a well 91 m away. After radionuclides arrived at the pumping well, the contaminated effluent was discharged to an unlined ditch leading to a playa where it was expected to evaporate. However, recent data from a well near the ditch and results from detailed models of the experiment by LLNL personnel have convincingly demonstrated that radionuclides from the ditch eventually reached the water table some 220 m below land surface. The models presented in this paper combine aspects of these detailed models with concepts of basin-scale flow to estimate the likely extent of contamination resulting from this experiment over the next 1,000 years. The models demonstrate that because regulatory limits for radionuclide concentrations are exceeded only by tritium and the half-life of tritium is relatively short (12.3 years), the maximum extent of contaminated groundwater has or will soon be reached, after which time the contaminated plume will begin to shrink because of radioactive decay. The models also show that past and future groundwater pumping from water supply wells within Frenchman Flat basin will have negligible effects on the extent of the plume.

54 ENVIRONMENTAL SCIENCES↗

Ru-promoted perovskites as effective redox catalysts for CO2 splitting and methane partial oxidation in a cyclic redox scheme

The current study reports AxA’1-xByB’1-yO3- perovskite redox catalysts (RCs) for CO2-splitting and methane partial oxidation (POx) in a cyclic redox scheme. Strontium (Sr) and iron (Fe) were chosen as A and B site elements with A’ being lanthanum (La), samarium (Sm) or yttrium (Y), and B’ being manganese (Mn), or titanium (Ti) to tailor their equilibrium oxygen partial pressures (P_(O_2 ) s) for CO2-splitting and methane partial oxidation. DFT calculations were performed for predictive optimization of the oxide materials whereas experimental investigation confirmed the DFT predicted redox performance. The redox kinetics of the RCs improved significantly by 1 wt.% ruthenium (Ru) impregnation without affecting their redox thermodynamics. Ru impregnated LaFe0.375Mn0.625O3 (A=0, A’=La, B=Mn, and B’=0) was the most promising RC in terms of its superior redox performance (CH4/CO2 conversion >90% and CO selectivity~ 95%) at 800oC. Long-term redox testing over Ru impregnated LaFe0.375Mn0.625O3 indicated stable performance during the first 30 cycles following with a ~25% decrease in the activity during the last 70 cycles. Air treatment was effective to reactivate the redox catalyst. Detailed characterizations revealed the underlying mechanism for redox catalyst deactivation and reactivation. Furthermore, this study not only validated a DFT guided mixed oxide design strategy for CO2 utilization but also provides potentially effective approaches to enhance redox kinetics as well as long-term redox catalyst performance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Subcomponent Validation of Composite Joints for the Marine Energy Advanced Materials Project

The Marine Energy Advanced Materials project is an ongoing multi-year, multi-lab project with the main goals of addressing barriers and uncertainties facing marine energy developers in adopting advanced materials for structural applications. NREL's goals of the project were to address subcomponents testing needs for marine energy materials, to improve understanding of design allowables at the full-scale and provide near net-scale static and fatigue data of composite subcomponents using materials applicable to the marine energy industry. In the long term, the test method development and data generated would be used to inform standards development. This report outlines perhaps one of the largest-scale studies conducted with regards to saltwater conditioning of various composite material subcomponents and their subsequent structural validation, specifically directed at the marine renewable energy industry. A variety of fiberglass composite panels with epoxy and vinyl ester epoxy resin systems were manufactured at Montana State University, which were then used to manufacture an array of different types of subcomponent test specimens at the National Renewable Energy Laboratory's Flatirons Campus. These subcomponents were in the form of T-bolt and double-ended-insert specimens, which were intended to represent bonded and mechanical bolted connections for thick composite laminates, metal-metal and composite lap shear specimens to evaluate adhesion of constituent materials, and adhesive beam-shear specimens as part of an effort to better evaluate the characteristics of thick adhesive bondlines. Overall, the materials used were fiberglass reinforced epoxy and vinyl ester matrix composites, epoxy and methacrylate adhesives, and 316 and 2507 stainless steels. Specimens were then conditioned in salt water at various temperatures and for various periods of time at Florida Atlantic University and Pacific Northwest National Laboratory. All specimens were then mechanically characterized and validated using various test methods under static and fatigue loading conditions at NREL's Structural Technology Laboratory. Throughout the conditioning and mechanical validation process, valuable experience was gained, which will help guide future test method development for marine energy materials. In many instances, the results indicated similar observations as to what had been observed during previous coupon scale characterization efforts that provided a vital understanding of the scale up process. However in some instances, unexpected phenomena were observed, such as interactions between the adhesives and 316 steel. Furthermore, some materials exhibited significant degradation due to the saltwater conditioning. Ultimately, this report provides a detailed summary of the specimens that were designed, the subcomponent test methods that were developed, and the results that were generated, which will serve as important guidance for marine renewable energy developers and researchers for future structural designs and validation.

16 TIDAL AND WAVE POWER↗

Evaluating ZEBRA Battery Module under the Peak-Shaving Duty Cycles

With the recent rapid increase in demand for reliable, long-cycle life, and safe battery technologies for large-scale energy-storage applications, a battery module based on ZEBRA battery chemistry is extensively evaluated for its application in peak shaving duty cycles. First, this module is tested with a full capacity cycle consisting of a charging process (factory default) and a discharging process with a current of 40 A. The battery energy efficiency (discharge vs. charge) is about 90%, and the overall energy efficiency is 80.9%, which includes the auxiliary power used to run the battery management system electronics and self-heating to maintain the module operating temperature (265 °C). Generally, because of the increased self-heating during the holding times that exist for the peak shaving duty cycles, the overall module efficiency decreases slightly for the peak-shaving duty cycles (70.7–71.8%) compared to the full-capacity duty cycle. With a 6 h, peak-shaving duty cycle, the overall energy efficiency increases from 71.8% for 7.5 kWh energy utilization to 74.1% for 8.5 kWh. We conducted long-term cycling tests of the module at a 6 h, peak-shaving duty cycle with 7.5 kWh energy utilization, and the module exhibited a capacity degradation rate of 0.0046%/cycle over 150 cycles (>150 days).

25 ENERGY STORAGE↗