Search NASA⌕ Search

SEARCH · Search NASA

Results for “low noise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Multi-Dimensional Spectroscopy with Intense Entangled Beams: Entanglement-Enabled Phase Matching in a Collinear Beam Geometry

The experimental realization of quantum molecular spectroscopy with entangled photons remains challenging owing to the low signal-to-noise ratio resulting from the use of low-flux entangled photons. High-flux entangled photons via intense entangled beams can be used to improve the signal-to-noise ratio, but the presence of unentangled photons contaminates the quantum signal stemming from entangled photons. Here, we demonstrate how intense entangled beams can be used in multi-dimensional spectroscopy while retaining the advantage of photon entanglement. Our approach is broadly applicable to odd-ordered nonlinear spectroscopies, and it generates purely quantum spectroscopic signals. The proposed approach allows the recording of desired phase-matched signals even in a collinear beam geometry, which lifts the requirement of complicated beam geometry setups for phase matching in multi-dimensional spectroscopies.

Absorption spectroscopy↗

High precision magnetic field measurement and mapping of the LEReC 180 degree bending magnet using very low field NMR with hall combined probe (140 - 350 gauss)

The Relativistic Heavy Ion Collider (RHIC) at BNL are using the Low Energy RHIC Electron Cooling (LEReC) to conduct experiments that search for the quantum chromodynamic (QCD) critical point. The first ever electron cooling based on the RF acceleration of electron beams was experimentally demonstrated on April 5, 2019 at LEReC at BNL. The first critical step in obtaining successful 3D non-magnetized cooling of the Au ion bunches in the RHIC cooling section was matching the electron beam energy with a relative error less than 5*10 -4 to the ion beam energy. Part of the LEReC beamline is a dipole magnet that bends the electron beam 180 degree. One of the most outstanding measurement challenges is that the dipole field is so low (≈200 G). Most of the existing NMR probes can only measure fields >400 G. Lower signal-to-noise ratio at low fields is requires the use of larger sample volumes. Working with CAYLAR, a NMR probe has been redesigned and optimized for these low field measurements with high resolution. We report the methods, challenges, and results for extensive magnetic field mappings of the 180 dipole magnet. A combination of NMR and Hall sensors has been successfully implemented to measure uniform field regimes inside the magnet center area and non-uniform field regimes at the magnet ends. Detailed measurement and mapping have been performed at five radii and five heights along the beam trajectory. Meanwhile a finite element magnetic modeling simulation of the magnet using Opera software has been performed. The calculated and measured data are compared, and the calculated data is good reference for measured data over long length mapping from magnet edge to center. The measured magnetic measurement data is directly useful for beam instrumentation, diagnostics and operation.

Magnetic Field Measurement↗

EIC Transverse emittance growth due to crab cavity RF noise: Estimates and mitigation

The Electron-Ion Collider (EIC) requires crab cavities to compensate for a 25 mrad crossing angle and achieve maximum luminosity. The crab cavity Radio Frequency (RF) system will inject low levels of noise to the crabbing field, generating transverse emittance growth and potentially limiting luminosity lifetime. In this work, we estimate the transverse emittance growth rate as a function of the Crab Cavity RF noise and quantify RF noise specifications for reasonable performance. Finally, we evaluate the possible mitigation of the RF noise induced emittance growth via a dedicated feedback system.

43 PARTICLE ACCELERATORS↗

Pickup Specifications for Crab Cavity Noise Feedback Pickup

The Electron-Ion Collider will employ crab cavities to compensate for the significant 25 mrad crossing angle, leading to an order of magnitude increase in luminosity. The crab cavity Radio Frequency system will inject low levels of noise to the crabbing field, generating transverse emittance growth and potentially limiting luminosity lifetime. A novel dedicated feedback system acting through the crab cavities has been proposed to mitigate emittance growth. The perfor mance of the noise feedback will largely depend on its pickup precision. In this note we present pickup specifications to achieve the required performance.

43 PARTICLE ACCELERATORS↗

A Preprocessing Tool for Enhanced Ion Mobility–Mass Spectrometry-Based Omics Workflows

The ability to improve the data quality of ion mobility–mass spectrometry (IM-MS) measurements is of great importance for enabling modular and efficient computational workflows and gaining better qualitative and quantitative insights from complex biological and environmental samples. We developed the PNNL PreProcessor, a standalone and user-friendly software housing various algorithmic implementations to generate new MS-files with enhanced signal quality and in the same instrument format. Different experimental approaches are supported for IM-MS based on Drift-Tube (DT) and Structures for Lossless Ion Manipulations (SLIM), including liquid chromatography (LC) and infusion analyses. The algorithms extend the dynamic range of the detection system, while reducing file sizes for faster and memory-efficient downstream processing. Specifically, multidimensional smoothing improves peak shapes of poorly defined low-abundance signals, and saturation repair reconstructs the intensity profile of high-abundance peaks from various analyte types. Further, other functionalities are data compression and interpolation, IM demultiplexing, noise filtering by low intensity threshold and spike removal, and exporting of acquisition metadata. Several advantages of the tool are illustrated, including an increase of 19.4% in lipid annotations and a two-times faster processing of LC-DT IM-MS data-independent acquisition spectra from a complex lipid extract of a standard human plasma sample. The software is freely available at https://omics.pnl.gov/software/pnnl-preprocessor.

59 BASIC BIOLOGICAL SCIENCES↗

Optimal Cosmic Microwave Background Lensing Reconstruction and Parameter Estimation with SPTpol Data

Here, we perform the first simultaneous Bayesian parameter inference and optimal reconstruction of the gravitational lensing of the cosmic microwave background (CMB), using 100 deg 2 of polarization observations from the SPTpol receiver on the South Pole Telescope. These data reach noise levels as low as 5.8 μK arcmin in polarization, which are low enough that the typically used quadratic estimator (QE) technique for analyzing CMB lensing is significantly suboptimal. Conversely, the Bayesian procedure extracts all lensing information from the data and is optimal at any noise level. We infer the amplitude of the gravitational lensing potential to be ${A}_{\phi }=0.949\,\pm \,0.122$ using the Bayesian pipeline, consistent with our QE pipeline result, but with 17% smaller error bars. The Bayesian analysis also provides a simple way to account for systematic uncertainties, performing a similar job as frequentist "bias hardening" or linear bias correction, and reducing the systematic uncertainty on A Φ due to polarization calibration from almost half of the statistical error to effectively zero. Finally, we jointly constrain A Φ along with A L , the amplitude of lensing-like effects on the CMB power spectra, demonstrating that the Bayesian method can be used to easily infer parameters both from an optimal lensing reconstruction and from the delensed CMB, while exactly accounting for the correlation between the two. These results demonstrate the feasibility of the Bayesian approach on real data, and pave the way for future analysis of deep CMB polarization measurements with SPT-3G, Simons Observatory, and CMB-S4, where improvements relative to the QE can reach 1.5 times tighter constraints on A Φ and seven times lower effective lensing reconstruction noise.

79 ASTRONOMY AND ASTROPHYSICS↗

Identifying Different Classes of Seismic Noise Signals Using Unsupervised Learning

Abstract Proper classification of nontectonic seismic signals is critical for detecting microearthquakes and developing an improved understanding of ongoing weak ground motions. We use unsupervised machine learning to label five classes of nonstationary seismic noise common in continuous waveforms. Temporal and spectral features describing the data are clustered to identify separable types of emergent and impulsive waveforms. The trained clustering model is used to classify every 1 s of continuous seismic records from a dense seismic array with 10–30 m station spacing. We show that dominate noise signals can be highly localized and vary on length scales of hundreds of meters. The methodology demonstrates the complexity of weak ground motions and improves the standard of analyzing seismic waveforms with a low signal‐to‐noise ratio. Application of this technique will improve the ability to detect genuine microseismic events in noisy environments where seismic sensors record earthquake‐like signals originating from nontectonic sources.

Johnson, Christopher W.↗

High-sensitivity telecommunication-compatible photoconductive terahertz detection through carrier transit time reduction

We present a telecommunication-compatible photoconductive terahertz detector realized without using any short-carrier-lifetime photoconductor. By utilizing plasmonic contact electrodes on a thin layer of high-mobility photoconductor, the presented detector offers a short transit time for the majority of the photocarriers in the absence of a short-carrier-lifetime photoconductor. Consequently, high-sensitivity terahertz detection is achieved with a record-high signal-to-noise ratio of 122 dB over a 3.6 THz bandwidth under an optical probe power of 10 mW. To achieve such a high sensitivity, the device geometry is chosen to maintain a high resistance and low Johnson Nyquist noise. This design approach can be widely applied for terahertz detection using various semiconductors and optical wavelengths, without being limited by the availability of short-carrier-lifetime photoconductors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Front-End Design for SiPM-Based Monolithic Neutron Double Scatter Imagers

Neutron double scatter imaging exploits the kinematics of neutron elastic scattering to enable emission imaging of neutron sources. Due to the relatively low coincidence detection efficiency of fast neutrons in organic scintillator arrays, imaging efficiency for double scatter cameras can also be low. One method to realize significant gains in neutron coincidence detection efficiency is to develop neutron double scatter detectors which employ monolithic blocks of organic scintillator, instrumented with photosensor arrays on multiple faces to enable 3D position and multi-interaction time pickoff. Silicon photomultipliers (SiPMs) have several advantageous characteristics for this approach, including high photon detection efficiency (PDE), good single photon time resolution (SPTR), high gain that translates to single photon counting capabilities, and ability to be tiled into large arrays with high packing fraction and photosensitive area fill factor. However, they also have a tradeoff in high uncorrelated and correlated noise rates (dark counts from thermionic emissions and optical photon crosstalk generated during avalanche) which may complicate event positioning algorithms. We have evaluated the noise characteristics and SPTR of Hamamatsu S13360-6075 SiPMs with low noise, fast electronic readout for integration into a monolithic neutron scatter camera prototype. The sensors and electronic readout were implemented in a small-scale prototype detector in order to estimate expected noise performance for a monolithic neutron scatter camera and perform proof-of-concept measurements for scintillation photon counting and three-dimensional event positioning.

47 OTHER INSTRUMENTATION↗

Percolation and nanosecond fluctuators in V 2 O 3 films within the metal–insulator transition

Vanadium sesquioxide (V 2 O 3 ) exhibits a metal–insulator transition (MIT) at 160 K between a low temperature, monoclinic, antiferromagnetic Mott insulator and a high temperature, rhombohedral, paramagnetic, metallic phase. In thin films, a percolative transition takes place over a finite temperature range of phase coexistence. We study the fluctuating dynamics of this percolative MIT by measuring voltage noise spectra at both low frequencies (up to 100 kHz) and radio frequencies (between 10 MHz and 1 GHz). Noise intensity quadratic in bias is observed in the MIT region, as expected for resistive fluctuations probed nonperturbatively by the current. The low frequency noise resembles flicker-type 1/f β noise, often taking on the form of Lorentzian noise dominated by a small number of fluctuators as the volume fraction of the insulating phase dominates. Radio frequency noise intensity also quadratic in the bias current allows the identification of resistance fluctuations with lifetimes below 1 ns, approaching timescales seen in non-equilibrium pump–probe studies of the transition. We find quantitative consistency with a model for fluctuations in the percolative fraction. The thermodynamics of the MIT suggests that dominant fluctuations are ones that alter small volumes affecting the connectivity of domain boundaries. This noise serves as a sensitive and nonperturbative probe for the dynamics of switching phenomena in this system.

36 MATERIALS SCIENCE↗

Clustering Nuclear Magnetic Resonance: Machine learning assistive rapid two‐dimensional relaxometry mapping

Abstract Low‐field nuclear magnetic resonance (NMR) relaxometry is an attractive approach from point‐of‐care testing medical diagnosis to in situ oil‐gas exploration. One of the problems, however, is the inherently long relaxation time of the (liquid) samples, (and hence low signal‐to‐noise ratio) which causes unnecessarily long repetition time. In this work, a new class of methodology is presented for rapid and accurate object classification using NMR relaxometry with the aid of machine learning. It is demonstrated that the sensitivity and specificity of the classification is substantially improved with higher order of (pseudo)‐dimensionality (e.g., 2D‐ or multi‐dimensional). This new methodology (termed as ‘Clustering NMR’) may be extremely useful for rapid and accurate object classification (in less than a minute) using low‐field NMR.

Peng, Weng Kung↗

Optics-Free Chip-Scale Intraoperative Imaging Using NIR-Excited Upconverting Nanoparticles

Here we present an optics-free CMOS image sensor that incorporates a novel time-gated dual-photodiode pixel design to allow filter- and lens-less image acquisition of near-infrared-excited (NIR-excited) upconverting nanoparticles. Recent biomedical advances have highlighted the benefits of NIR excitation, but NIR interaction with silicon has remained a challenge, even with high-performance optical blocking filters. Using a secondary diode and a dual-photodiode design, this sensor is able to remove the 100s of mV of NIR background on pixels and bring it down to single-digit mV level, nearing its noise floor of 2.2 mV rms, not achievable with any optical filter. Non-linear effects of background cancellation using the diode pair has been mitigated using an initial one-time pixel-level curve fitting and calibration in a post-processing setting. This imager comprises a highly linear 11 fF metal-oxide-metal (MOM) capacitor and includes integrated angle-selective gratings to reject oblique light and enhance sharpness. Each pixel also includes two distinct correlated double sampling schemes, to remove low frequency flicker noise and systematic offset in the datapath. We demonstrate the performance of this imager using pulsed NIR-excited upconverting nanoparticles on standard United-States-Air-Force (USAF) resolution targets and achieve an SNR of 15 dB, while keeping NIR background below 6 mV. This 36-by-80-pixel array measures only 2.3 mm by 4.8 mm and can be thinned down to 25 µm, allowing it to become surgically compatible with intraoperative instruments and equipment, while remaining optics-free.

42 ENGINEERING↗

Developing a system for in vivo imaging of maize roots containing iodinated contrast media in soil using synchrotron XCT and XRF

We sought to develop a novel experimental system which enabled application of iodinated contrast media to in vivo plant roots intact in soil and was compatible with time-resolved synchrotron X-ray computed tomography imaging. The system was developed to overcome issues of low contrast to noise within X-ray computed tomography images of plant roots and soil environments, the latter of which can complicate image processing and result in the loss of anatomical information. To demonstrate the efficacy of the system we employ the novel use of both synchrotron X-ray computed tomography and synchrotron X-ray fluorescence mapping to capture the translocation of the contrast media through root vasculature into the leaves. With the application of contrast media we identify fluid flow in root vasculature and visualise anatomical features, which are otherwise often only observable in ex vivo microscopy, including: the xylem, metaxylem, pith, fibres in aerenchyma and leaf venation. We are also able to observe interactions between aerenchyma cross sectional area and solute transport in the root vasculature with depth. Our novel system was capable of successfully delivering sufficient contrast media into root and leaf tissues such that anatomical features could be visualised and internal fluid transport observed. We propose that our system could be used in future to study internal plant transport mechanisms and parameterise models for fluid flow in plants.

59 BASIC BIOLOGICAL SCIENCES↗

Self-reported health impacts of do-it-yourself air cleaner use in a smoke-impacted community

Smoke exposure from wildfires or residential wood burning for heat is a public health problem for many communities. Do-It-Yourself (DIY) portable air cleaners (PACs) are promoted as affordable alternatives to commercial PACs, but evidence of their effect on health outcomes is limited. Pilot test an evaluation of the effect of DIY PAC usage on self-reported symptoms, and investigate barriers and facilitators of PAC use, among members of a tribal community that routinely experiences elevated concentrations of fine particulate matter (PM 2.5 ) from smoke. We conducted studies in Fall 2021 (“wildfire study”; N = 10) and Winter 2022 (“wood stove study”; N = 17). Each study included four sequential one-to-two-week phases: 1) initial, 2) DIY PAC usage ≥8 h/day, 3) commercial PAC usage ≥8 h/day, and 4) air sensor with visual display and optional PAC use. We continuously monitored PAC usage and indoor/outdoor PM 2.5 concentrations in homes. Concluding each phase, we conducted phone surveys about participants’ symptoms, perceptions, and behaviors. We analyzed symptoms associated with PAC usage and conducted an analysis of indoor PM 2.5 concentrations as a mediating pathway using mixed effects multivariate linear regression. We categorized perceptions related to PACs into barriers and facilitators of use. No association was observed between PAC usage and symptoms, and the mediation analysis did not indicate that small observed trends were attributable to changes in indoor PM 2.5 concentrations. Small sample sizes hindered the ability to draw conclusions regarding the presence or absence of causal associations. DIY PAC usage was low; loud operating noise was a barrier to use. This research is novel in studying health effects of DIY PACs during wildfire and wood smoke exposures. Such research is needed to inform public health guidance. Recommendations for future studies on PAC use during smoke exposure include building flexibility of intervention timing into the study design.

54 ENVIRONMENTAL SCIENCES↗

Accurate determination of uranium isotope abundances by wavelength modulation spectroscopy in atomic beams

The design and demonstration of an optical analysis system based on wavelength modulation spectroscopy in an atomic beam for uranium isotope abundance determinations is presented. This system probes the uranium 5f 3 6d7s 2 ( 5 L 6 ) → 5f 2 6d 2 7s 2 ( 5 K 5 ) transition at 861.031 nm, which is considered to be the most suitable transition for uranium isotopic analysis. A new laser characterization strategy was developed for the conditions where optimum laser wavelength modulation depth was small compared to the free spectral range (FSR) of etalons. Two capabilities enabled the higher-precision determination of isotope abundances of atomic beams: (1) reduction of low-frequency additive noise, especially the noise caused by black-body radiation and (2) suppression of non-absorption transmission losses. The performance of this system was validated with uranium samples of various isotopic compositions. Further, by comparing the measurements using natural uranium samples between the direct absorption and the wavelength modulation approaches, a 21-fold decrease in uncertainty of the integrated absorbance and a 6.8-fold improvement in the 1-σ precision of the number density were achieved. In addition, by comparing the results using uranium oxide samples, a 6.1-fold decrease in the uncertainty of inferred isotope abundance was obtained. These results demonstrate that the 1f-normalized 2f wavelength modulation spectroscopy (WMS-2f/1f) technique enables higher-precision analysis of atomic beams.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Atomic Magnetometry Using a Metasurface Polarizing Beamsplitter in Silicon-on-Sapphire

Here, we demonstrate atomic magnetometry using a metasurface polarizing beamsplitter fabricated on a silicon-on-sapphire (SOS) platform. The metasurface splits a beam that is near-resonant with the rubidium atoms (795 nm) into orthogonal linear polarizations, enabling the measurement of magnetically sensitive circular birefringence in rubidium vapor through balanced polarimetry. We incorporated the metasurface into an atomic magnetometer based on nonlinear magneto-optical rotation and measured subnanotesla sensitivity, which is limited by low-frequency technical noise and transmission loss through the metasurface. To our knowledge, this work represents the first demonstration of SOS nanophotonics for atom-based sensing and paves the way for highly integrated, miniaturized atomic sensors with enhanced sensitivity and portability.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Challenges in the detection of gases in exoplanet atmospheres

Claims of detections of gases in exoplanet atmospheres often rely on comparisons between models including and excluding specific chemical species. However, the space of molecular combinations available for model construction is vast and highly degenerate. Only a limited subset of these combinations is typically explored for any given detection. As a result, apparent detections of trace gases risk being artefacts of incomplete modelling rather than robust identification of atmospheric constituents, especially in the low-signal-to-noise regime. Here, using the sub-Neptune K2-18 b as a case study, we show that recent biosignature claims vanish when the model space is expanded, with numerous alternatives providing equally good or better fits. We demonstrate that the significance of a claimed detection relies on the choice of models being compared, and that model preference does not in itself imply the presence of a specific gas. In conclusion, we recommend treating model comparisons instead as relative adequacy tests, which should be supported by theoretical predictions and complementary metrics of statistical significance to attribute a signal to a particular gas.

Astronomy and AstroPhysics↗

Continuous recoil-driven lasing and cavity frequency pinning with laser-cooled atoms

Abstract Laser-cooled gases of atoms interacting with the field of an optical cavity are a versatile tool for quantum sensing and the simulation of quantum systems. These systems can exhibit phenomena such as self-organization phase transitions, lasing mechanisms, squeezed states and protection of quantum coherence. However, investigations of these phenomena typically occur in a discontinuous manner due to the need to reload atomic ensembles. Here we demonstrate hours-long continuous lasing from laser-cooled 88 Sr atoms loaded into a ring cavity. The required inversion to produce lasing arises from inversion in the atomic-momentum degrees of freedom, which is linked to the self-organization phase transitions and collective atomic recoil lasing observed previously only in a cyclic fashion. We find that over a broad parameter range, the sensitivity of the lasing frequency to changes in cavity frequency is significantly reduced due to an atomic loss mechanism, suggesting a potential approach for mitigating low-frequency cavity noise. Our findings open opportunities for continuous cavity quantum electrodynamics experiments and robust and continuous super-radiant lasers.

Schäfer, Vera M. (ORCID:0000000210003737)↗