Search NASA⌕ Search

SEARCH · Search NASA

Results for “measures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Fine-Grained Application Energy and Power Measurements on the Frontier Exascale System

The increasing complexity and power/energy demands of heterogeneous exascale systems, such as the Frontier supercomputer, present significant challenges for measuring and optimizing power consumption in applications. Current tools either lack the resolution to capture fine-grained power and energy measurements, fail to validate in-band measurements against out-of-band power sensors, or cannot integrate this information with application performance events in a scalable manner. This paper introduces a novel open-source performance toolkit that integrates extended PAPI components with Score-P plugins to enable in-band, fine-grained power and energy measurements, while also supporting validation using power meter measurements for both CPUs and GPUs. One key contribution is the ability to perform millisecond-level power and energy measurements for AMD MI250X GPUs, mapping them to application performance events within a single trace and measurement system that scales. Our toolkit combines coarse-grained measurements from cray_pm counters with high-resolution metrics from rocm_smi and RAPL, converting GPU instantaneous accumulated energy into power to capture both transient and steady-state power behavior, a capability often missed by out-of-band and monitoring tools. By mapping these metrics to specific application regions, developers can identify energy hotspots, address inefficiencies in GPU kernel execution, and validate in-band measurements against external measurements. We demonstrate the effectiveness of this approach through case studies using benchmarks such as GPU rocblas_sgemm, BLIS c_blas_dgemm, and rocHPL, highlighting the variability of the measurements and the impact of transient power spikes on kernel-level efficiency.

Hernandez Mendoza, Oscar [ORNL] (ORCID:00000002538↗

Advanced Measurements for Resilient Integration of Inverter-Based Resources: PROGRESS MATRIX Final Report

As nearly every aspect of the electric power grid undergoes rapid change, measurement technologies that support grid operation and planning must evolve as well. The rapid large-scale deployment of inverter-based resources (IBRs) vital to achieving the nation’s clean energy goals has in some cases led to negative impacts on the reliability and security of the bulk power system (BPS). Advanced power system measurements, including synchronized phasor and waveform measurements, are key to making IBR integration secure and reliable. To this end, the Department of Energy (DOE) initiated the PROGRESS MATRIX project to develop advanced measurement capabilities and analytics that will accelerate adoption of IBRs while improving the reliability and resilience of the BPS. This report discusses the outcomes of the project, which was a joint effort between the Pacific Northwest National Laboratory (PNNL), Oak Ridge National Laboratory (ORNL), the National Renewable Energy Laboratory (NREL), and Lawrence Berkeley National Laboratory (LBNL). In the project’s first year, PNNL, NREL, and ORNL partnered with the Bonneville Power Administration (BPA), the Western Area Power Administration (WAPA), and Kauai Island Utility Cooperative (KIUC) to understand their existing measurement capabilities and the gaps limiting deployment of IBR-focused measurement systems and analytics. The other primary activity in the first year was deployment of GridSweep instruments, which provide unprecedented precision in waveform measurement while probing distribution systems. The instruments were deployed at Dominion Energy and the University of California, Riverside. In the project’s second year, the input from partner utilities and collected measurements were used to advance measurement capabilities. Twelve analytical methods spanning disturbance analysis, power plant evaluation, feeder evaluation, and modeling were developed. Two software tools were developed, one to analyze GridSweep measurements and another to automatically evaluate the control performance of power plants connected to the BPS. Testbeds at ORNL and NREL were augmented to better enable studies of IBR integration. The project culminated in demonstrations of these analytical methods, software tools, and testbeds, both in the field and in the laboratory. This report discusses these various accomplishments and documents the significant progress in developing advanced measurement capabilities to support the secure, reliable, and accelerated adoption of IBRs in the BPS.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Solid State Quantum Refrigeration Superconducting, Absorption and Measurement Based (Final Technical Report)

During this DOE grant, DE-SC0017890, in place for the past six years, all proposed research was carried out and published in peer-reviewed papers, as well as other projects that emerged during the research. In that effort the research team accomplished all proposed research, as well as many closely related research projects discovered and conceived of during the grant. These works included “Efficient Quantum Measurement Engines”, a work published in Physical Review Letters, giving a theory of quantum measurement-based engines, which uses quantum measurement as a resource. These engines are designed to efficiently convert energy from the stochastic quantum measurement process into useful work. Further publications include “Experimental Realization of a Quantum Dot Energy Harvester”, a joint theory and experimental work in collaboration with the group of Charles Smith in Cambridge, UK, as well as long time theoretical collaborators, Rafael Sánchez and Björn Sothmann. This work, featured as an Editor’s Suggestion in Physical Review Letters, realized an earlier theoretical proposal of ours, whereby two resonant tunneling quantum dots are connected to a central electronic cavity that is heated by a hot energy source. We also published “Superconducting Quantum Refrigerator: Breaking and Rejoining Cooper Pairs with Magnetic Field Cycles” a work done in collaboration with experimentalist Francesco Giazotto from ENS Pisa, Italy, which also resulted in a patent. This paper, published in Phys. Rev. Applied, advanced the concept of a cyclic fridge based on the normal/superconducting phase transition together with layered materials separated by tunnel junctions. We also completed the proposed research on a heat transistor, publishing “Thermal transistor and thermometer based on Coulomb-coupled conductors”, carried out as a collaboration between my group and theorists Splettstoesser (Lund U., Sweden), Sothmann (U. Duisburg-Essen, Germany), and Sánchez (U. Autónoma de Madrid, Spain). We carried out an analysis of a quantum coupled to a quantum point contact as a sensitive thermometer and heat transistor. We found the optimal statistical estimator for the temperature and compared it with experiments on the same type of devices. We also investigated autonomous quantum absorption refrigerators using quantum dots to cool by using a very hot thermal reservoir to drive heat between two other reservoirs. In the article “Quantifying the quantum heat contribution from a driven superconducting circuit”, we demonstrated that for a driven superconducting circuit, we showed heat flow provided by a hot source to the qubit can be switched on and off by varying external parameters, the frequency and the intensity of the driving. In the work “Stochastic thermodynamic cycles of a mesoscopic thermoelectric engine”, we reconsidered the autonomous thermoelectric heat engine in terms of underlying cycles. Rather than periodic behavior, the cycles were stochastic in nature. Nevertheless, by undertaking a graph theoretical analysis of the elementary transport processed, great quantitative and qualitative insight could be found. We also considered the quantum measurement process and showed that a quantum version of Maxwell’s demon could be related to the work extraction of a quantum system, closely related to arrow-of-time measures for quantum measurement, as described in our article “Thermodynamics of quantum measurement and Maxwell's demon's arrow of time”. This work was selected in Phys. Rev. A as an Editor’s Suggestion. A recent preprint titled “Cyclic Superconducting Quantum Refrigerators Using Guided Fluxon Propagation” accomplished an important piece of this grant: to propose a new kind of quantum refrigerator using the dynamics of fluxons in a type II superconductor. This invention envisioned a race-track type geometry where fluxons are confined. By applying a gradient of magnetic field together with electric current in a Corbino geometry, the circulating fluxons can actively cool a cold reservoir, realizing a new type of cyclic superconducting refrigerator. We also investigated the possibility of thermal control from different points of view. The application of quantum measurement to the system gives a new kind of control on the system of interest – we have pioneered this approach and shown that measurement can boost the thermal power of quantum engines as described in “Continuous measurement boosted adiabatic quantum thermal machines”. The ability to have heat flows on demand is an outstanding challenge, and we have provided new solutions to this problem in Thermal control across a chain of electronic nanocavities” for a chain of electron cavities using gating voltage control. The control methods using qubit/qubit coupling to create absorption fridges at their most fundamental level have also been developed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

EPCAPE-PT-LANL Measurements: Soot Particle Aerosol Mass Spectrometer

Coastal cities offer a unique environment for studying aerosol-cloud interactions and the effects of urban emissions on cloud properties. As part of the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE), the Partitioning Thrust by Los Alamos National Laboratory (EPCAPE-PT-LANL) was conducted. Our campaign focused on measuring the optical and chemical properties of aerosols and their interactions within marine stratocumulus clouds in La Jolla, California. EPCAPE-PT-LANL enhances the primary goals of EPCAPE through innovative observations of vapor-phase transitions between aerosols and cloud droplets, the impact of black carbon on aerosol-cloud dynamics, and the effects of cloud processing on aerosol optical properties. Instrument: Soot particle-Aerosol Mass Spectrometer. (Aerodyne Inc.) Header: - Organic_GCVIoff[ug/m3]: Concentration of organic compounds measured via the Main Inlet (out-of-cloud) in micrograms per cubic meter. - Nitrate_GCVIoff[ug/m3]: Concentration of nitrate measured via the Main Inlet (out-of-cloud) in micrograms per cubic meter. - Sulfate_GCVIoff[ug/m3]: Concentration of sulfate measured via the Main Inlet (out-of-cloud) in micrograms per cubic meter. - Chloride_GCVIoff[ug/m3]: Concentration of chloride measured via the Main Inlet (out-of-cloud) in micrograms per cubic meter. - Ammonium_GCVIoff[ug/m3]: Concentration of ammonium via the Main Inlet (out-of-cloud) in micrograms per cubic meter. - Organic_GCVIon[ug/m3]: Concentration of organic compounds measured in-cloud via CVI in micrograms per cubic meter. - Nitrate_GCVIon[ug/m3]: Concentration of nitrate measured in-cloud via CVI in micrograms per cubic meter. - Sulfate_GCVIon[ug/m3]: Concentration of sulfate measured in-cloud via CVI in micrograms per cubic meter. - Chloride_GCVIon[ug/m3]: Concentration of chloride measured in-cloud via CVI in micrograms per cubic meter. - Ammonium_GCVIon[ug/m3]: Concentration of ammonium measured in-cloud via CVI in micrograms per cubic meter. - CVI_Flag[bool]: A boolean flag indicating whether the CVI was active (true) or inactive (false) during the measurement.

54 ENVIRONMENTAL SCIENCES↗

EPCAPE-PT-LANL Measurements: Photoacoustic Extinctometer

Coastal cities offer a unique environment for studying aerosol-cloud interactions and the effects of urban emissions on cloud properties. As part of the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE), the Partitioning Thrust by Los Alamos National Laboratory (EPCAPE-PT-LANL) was conducted. Our campaign focused on measuring the optical and chemical properties of aerosols and their interactions within marine stratocumulus clouds in La Jolla, California. EPCAPE-PT-LANL enhances the primary goals of EPCAPE through innovative observations of vapor-phase transitions between aerosols and cloud droplets, the impact of black carbon on aerosol-cloud dynamics, and the effects of cloud processing on aerosol optical properties. Instrument: Photoacoustic Extinctiometer at 870 nm (Droplet Measurement Technology) Header: - AbsorptionNoise_870nm[1/Mm]: Noise level associated with the absorption measurement at 870 nm, expressed in inverse megameters (Mm⁻¹). - Absorption_870nm[1/Mm]: Absorption coefficient of aerosols measured at 870 nm, expressed in inverse megameters (Mm⁻¹). - Extinction_870nm[1/Mm]: Extinction coefficient of aerosols measured at 870 nm, expressing the sum of scattering and absorption by aerosols, in inverse megameters (Mm⁻¹). - Scattering_870nm[1/Mm]: Scattering coefficient of aerosols measured at 870 nm, expressed in inverse megameters (Mm⁻¹). - BackgroundAbsorption_870nm[1/Mm]: Background absorption measurement at 870 nm, used to correct the primary absorption data, expressed in inverse megameters (Mm⁻¹). - BackgroundScattering_870nm[1/Mm]: Background scattering measurement at 870 nm, used to correct the primary scattering data, expressed in inverse megameters (Mm⁻¹). - Temperature[C]: The ambient temperature at the time of the measurement, expressed in degrees Celsius. - RelativeHumidity[%]: The relative humidity at the time of the measurement, expressed as a percentage. - CVI_Flag[bool]: A boolean flag indicating whether the Counterflow Virtual Impactor (CVI) was active (true) or inactive (false) during the measurement

54 ENVIRONMENTAL SCIENCES↗

Reports of workshops on Probe Measurements of Particles and Radiation in the Atmosphere of Titan

The planned 1995 joint ESA-NASA Cassini mission to the Saturnian system will include an atmospheric probe to be dropped into the atmosphere of Titan for in situ measurements during descent. Because of the unique properties of the Titan atmosphere it is necessary to consider the peculiar requirements for such measurements and applicable techniques. The proceedings of two workshops dealing with the measurement of particles and radiation in the atmosphere of Titan are presented in two parts. The first part dealt with the measurement of particulate matter in the atmosphere of Titan. The second part dealt with the measurement of radiation in the atmosphere of Titan. The proceedings were first published and distributed informally, and are presented with only minor editorial changes. In the report of the particulate matter workshop, discussions of the mission background, the importance of the measurements, and descriptions of the desired information are followed by a description of appropriate measurement techniques and conclusions and recommendations. The proceeding for the workshop on radiation measurement and imaging contains a discussion of the importance of radiation measurements and imaging, and presents a summary of participants' experience with such measurements made from entry probes. This is followed by a description of appropriate measurement techniques and conclusions and recommendations.

Ragent, Boris↗

Experimental measurement of structural power flow on an aircraft fuselage

An experimental technique is used to measure structural intensity through an aircraft fuselage with an excitation load applied near one of the wing attachment locations. The fuselage is a relatively large structure, requiring a large number of measurement locations to analyze the whole of the structure. For the measurement of structural intensity, multiple point measurements are necessary at every location of interest. A tradeoff is therefore required between the number of measurement transducers, the mounting of these transducers, and the accuracy of the measurements. Using four transducers mounted on a bakelite platform, structural intensity vectors are measured at locations distributed throughout the fuselage. To minimize the errors associated with using the four transducer technique, the measurement locations are selected to be away from bulkheads and stiffeners. Furthermore, to eliminate phase errors between the four transducer measurements, two sets of data are collected for each position, with the orientation of the platform with the four transducers rotated by 180 degrees and an average taken between the two sets of data. The results of these measurements together with a discussion of the suitability of the approach for measuring structural intensity on a real structure are presented.

Cuschieri, J. M.↗

Performance measurement for information systems: Industry perspectives

Performance measurement has become a focal topic for information systems (IS) organizations. Historically, IS performance measures have dealt with the efficiency of the data processing function. Today, the function of most IS organizations goes beyond simple data processing. To understand how IS organizations have developed meaningful performance measures that reflect their objectives and activities, industry perspectives on IS performance measurement was studied. The objectives of the study were to understand the state of the practice in IS performance techniques for IS performance measurement; to gather approaches and measures of actual performance measures used in industry; and to report patterns, trends, and lessons learned about performance measurement to NASA/JSC. Examples of how some of the most forward looking companies are shaping their IS processes through measurement is provided. Thoughts on the presence of a life-cycle to performance measures development and a suggested taxonomy for performance measurements are included in the appendices.

Bishop, Peter C.↗

Measurements over distributed high performance computing and storage systems

Requirements are carefully described in descriptions of systems to be acquired but often there is no requirement to provide measurements and performance monitoring to ensure that requirements are met over the long term after acceptance. A set of measurements for various UNIX-based systems will be available at the 1992 Goddard Conference on Mass Storage Systems and Technologies. The authors invite others to contribute to the set of measurements. The framework for presenting the measurements of supercomputers, workstations, file servers, mass storage systems, and the networks that interconnect them are given. Production control and database systems are also included. Though other applications and third party software systems are not addressed, it is important to measure them as well. The capability to integrate measurements from all these components from different vendors, and from the third party software systems was recognized and there are efforts to standardize a framework to do this. The measurement activity falls into the domain of management standards. Standards work is ongoing for Open Systems Interconnection (OSI) systems management; AT&T, Digital, and Hewlett-Packard are developing management systems based on this architecture even though it is not finished. Another effort is in the UNIX International Performance Management Working Group. In addition, there are the Open Systems Foundation's Distributed Management Environment and the Object Management Group. A paper comparing the OSI systems management model and the Object Management Group model has been written. The IBM world has had a capability for measurement for various IBM systems since the 1970's and different vendors were able to develop tools for analyzing and viewing these measurements. Since IBM was the only vendor, the user groups were able to lobby IBM for the kinds of measurements needed. In the UNIX world of multiple vendors, a common set of measurements will not be as easy to get.

Williams, Elizabeth↗

Temperature and pressure effects on capacitance probe cryogenic liquid level measurement accuracy

The inaccuracies of liquid nitrogen and liquid hydrogen level measurements by use of a coaxial capacitance probe were investigated as a function of fluid temperatures and pressures. Significant liquid level measurement errors were found to occur due to the changes in the fluids dielectric constants which develop over the operating temperature and pressure ranges of the cryogenic storage tanks. The level measurement inaccuracies can be reduced by using fluid dielectric correction factors based on measured fluid temperatures and pressures. The errors in the corrected liquid level measurements were estimated based on the reported calibration errors of the temperature and pressure measurement systems. Experimental liquid nitrogen (LN2) and liquid hydrogen (LH2) level measurements were obtained using the calibrated capacitance probe equations and also by the dielectric constant correction factor method. The liquid levels obtained by the capacitance probe for the two methods were compared with the liquid level estimated from the fluid temperature profiles. Results show that the dielectric constant corrected liquid levels agreed within 0.5 percent of the temperature profile estimated liquid level. The uncorrected dielectric constant capacitance liquid level measurements deviated from the temperature profile level by more than 5 percent. This paper identifies the magnitude of liquid level measurement error that can occur for LN2 and LH2 fluids due to temperature and pressure effects on the dielectric constants over the tank storage conditions from 5 to 40 psia. A method of reducing the level measurement errors by using dielectric constant correction factors based on fluid temperature and pressure measurements is derived. The improved accuracy by use of the correction factors is experimentally verified by comparing liquid levels derived from fluid temperature profiles.

Edwards, Lawrence G.↗

The (mis)use of subjective process measures in software engineering

A variety of measures are used in software engineering research to develop an understanding of the software process and product. These measures fall into three broad categories: quantitative, characteristics, and subjective. Quantitative measures are those to which a numerical value can be assigned, for example effort or lines of code (LOC). Characteristics describe the software process or product; they might include programming language or the type of application. While such factors do not provide a quantitative measurement of a process or product, they do help characterize them. Subjective measures (as defined in this study) are those that are based on the opinion or opinions of individuals; they are somewhat unique and difficult to quantify. Capturing of subjective measure data typically involves development of some type of scale. For example, 'team experience' is one of the subjective measures that were collected and studied by the Software Engineering Laboratory (SEL). Certainly, team experience could have an impact on the software process or product; actually measuring a team's experience, however, is not a strictly mathematical exercise. Simply adding up each team member's years of experience appears inadequate. In fact, most researchers would agree that 'years' do not directly translate into 'experience.' Team experience must be defined subjectively and then a scale must be developed e.g., high experience versus low experience; or high, medium, low experience; or a different or more granular scale. Using this type of scale, a particular team's overall experience can be compared with that of other teams in the development environment. Defining, collecting, and scaling subjective measures is difficult. First, precise definitions of the measures must be established. Next, choices must be made about whose opinions will be solicited to constitute the data. Finally, care must be given to defining the right scale and level of granularity for measurement.

Valett, Jon D.↗

An intercomparison of aircraft instrumentation for tropospheric measurements of sulfur dioxide

As part of the NASA Tropospheric Chemistry Program, a series of field intercomparisons have been conducted to evaluate the state-of-the art for measuring key tropospheric species. One of the objectives of the third intercomparison campaign in this series, Chemical Instrumentation Test and Evaluation 3 (CITE 3), was to evaluate instrumentation for making reliable tropospheric aircraft measurements of sulfur dioxide, dimethyl sulfide, hydrogen sulfide, carbon disulfide, and carbonyl sulfide. This paper reports the results of the intercomparisons of five sulfur dioxide measurement methods ranging from filter techniques, in which samples collected in flight are returned to the laboratory for analyses (chemiluminescent or ion chromatographic), to near real-time, in-flight measurements via gas chromatographic, mass spectrometric, and chemiluminescent techniques. All techniques showed some tendency to track sizeable changes in ambient SO2 such as those associated with altitude changes. For SO2 mixing ratios in the range of 200 pptv to a few ppbv, agreement among the techniques varies from about 30% to several orders of magnitude, depending upon the pair of measurements intercompared. For SO2 mixing ratios less than 200 pptv, measurements from the techniques are uncorrelated. In general, observed differences in the measurement of standards do not account for the flight results. The CITE 3 results do not unambiguously identify one or more of the measurement techniques as providing valid or invalid SO2 measurements, but identify the range of 'potential' uncertainty in SO2 measurements reported by currently available instrumentation and as measured under realistic aircraft environments.

Gregory, Gerald L.↗

Laser-Induced Fluorescence Measurements and Modeling of Nitric Oxide in Counterflow Diffusion Flames

The feasibility of making quantitative nonintrusive NO concentration ([NO]) measurements in nonpremixed flames has been assessed by obtaining laser-induced fluorescence (LIF) measurements of [NO] in counterflow diffusion flames at atmospheric and higher pressures. Comparisons at atmospheric pressure between laser-saturated fluorescence (LSF) and linear LIF measurements in four diluted ethane-air counterflow diffusion flames with strain rates from 5 to 48/s yielded excellent agreement from fuel-lean to moderately fuel-rich conditions, thus indicating the utility of a model-based quenching correction technique, which was then extended to higher pressures. Quantitative LIF measurements of [NO] in three diluted methane-air counterflow diffusion flames with strain rates from 5 to 35/s were compared with OPPDIF model predictions using the GRI (version 2.11) chemical kinetic mechanism. The comparisons revealed that the GRI mechanism underpredicts prompt-NO by 30-50% at atmospheric pressure. Based on these measurements, a modified reaction rate coefficient for the prompt-NO initiation reaction was proposed which causes the predictions to match experimental data. Temperature measurements using thin filament pyrometry (TFP) in conjunction with a new calibration method utilizing a near-adiabatic H2-air Hencken burner gave very good comparisons with model predictions in these counterflow diffusion flames. Quantitative LIF measurements of [NO] were also obtained in four methane-air counterflow partially-premixed flames with fuel-side equivalence ratios (phi(sub B)) of 1.45, 1.6, 1.8 and 2.0. The measurements were in excellent agreement with model predictions when accounting for radiative heat loss. Spatial separation between regions dominated by the prompt and thermal NO mechanisms was observed in the phi(sub B) = 1.45 flame. The modified rate coefficient proposed earlier for the prompt-NO initiation reaction improved agreement between code predictions and measurements in the region where prompt-NO dominates. Finally, LIF measurements of NO were obtained in counterflow diffusion flames at 2 to 5 atm. Comparisons between [NO] measurements and predictions show that the GRI mechanism underpredicts prompt-NO by a factor of two to three at all pressures. In general, the results indicate a need for refinement of the CH chemistry, especially the pressure-dependent CH formation and destruction reactions.

Ravikrishna, Rayavarapu V.↗

Direct Detection Doppler Lidar for Spaceborne Wind Measurement

The theory of double edge lidar techniques for measuring the atmospheric wind using aerosol and molecular backscatter is described. Two high spectral resolution filters with opposite slopes are located about the laser frequency for the aerosol based measurement or in the wings of the Rayleigh - Brillouin profile for the molecular measurement. This doubles the signal change per unit Doppler shift and improves the measurement accuracy by nearly a factor of 2 relative to the single edge technique. For the aerosol based measurement, the use of two high resolution edge filters reduces the effects of background, Rayleigh scattering, by as much as an order of magnitude and substantially improves the measurement accuracy. Also, we describe a method that allows the Rayleigh and aerosol components of the signal to be independently determined. A measurement accuracy of 1.2 m/s can be obtained for a signal level of 1000 detected photons which corresponds to signal levels in the boundary layer. For the molecular based measurement, we describe the use of a crossover region where the sensitivity of a molecular and aerosol-based measurement are equal. This desensitizes the molecular measurement to the effects of aerosol scattering and greatly simplifies the measurement. Simulations using a conical scanning spaceborne lidar at 355 nm give an accuracy of 2-3 m/s for altitudes of 2-15 km for a 1 km vertical resolution, a satellite altitude of 400 km, and a 200 km x 200 km spatial.

Korb, C. Laurence↗

Sun and Sky Radiance Measurements and Data Analysis Protocols

This chapter is concerned with two types of radiometric measurements essential to verify atmospheric correction algorithms and to calibrate vicariously satellite ocean color sensors. The first type is a photometric measurement of the direct solar beam to determine the optical thickness of the atmosphere. The intensity of the solar beam can be measured directly, or obtained indirectly from measurements of diffuse global upper hemispheric irradiance. The second type is a measurement of the solar aureole and sky radiance distribution using a CCD camera, or a scanning radiometer viewing in and perpendicular to the solar principal plane. From the two types of measurements, the optical properties of aerosols, highly variable in space and time, can be derived. Because of the high variability, the aerosol properties should be known at the time of satellite overpass. Atmospheric optics measurements, however, are not easy to perform at sea, from a ship or any platform. This complicates the measurement protocols and data analysis. Some instrumentation cannot be deployed at sea, and is limited to island and coastal sites. In the following, measurement protocols are described for radiometers commonly used to measure direct atmospheric transmittance and sky radiance, namely standard sun photometers, fast-rotating shadow-band radiometers, automated sky scanning systems, and CCD cameras. Methods and procedures to analyze and quality control the data are discussed, as well as proper measurement strategies for evaluation of atmospheric correction algorithms and satellite-derived ocean color.

Frouin, Robert↗

Thermodynamic Activity Measurements with Knudsen Cell Mass Spectrometry

Coupling the Knudsen effusion method with mass spectrometry has proven to be one of the most useful experimental techniques for studying the equilibrium between condensed phases and complex vapors. The Knudsen effusion method involves placing a condensed sample in a Knudsen cell, a small "enclosure", that is uniformly heated and held until equilibrium is attained between the condensed and vapor phases. The vapor is continuously sampled by effusion through a small orifice in the cell. A molecular beam is formed from the effusing vapor and directed into a mass spectrometer for identification and pressure measurement of the species in the vapor phase. Knudsen cell mass spectrometry (KCMS) has been used for nearly fifty years now and continues to be a leading technique for obtaining thermodynamic data. Indeed, much of the well-established vapor specie data in the JANAF tables has been obtained from this technique. This is due to the extreme versatility of the technique. All classes of materials can be studied and all constituents of the vapor phase can be measured over a wide range of pressures (approximately 10(exp -4) to 10(exp -11) bar) and temperatures (500-2800 K). The ability to selectively measure different vapor species makes KCMS a very powerful tool for the measurement of component activities in metallic and ceramic solutions. Today several groups are applying KCMS to measure thermodynamic functions in multicomponent metallic and ceramic systems. Thermodynamic functions, especially component activities, are extremely important in the development of CALPHAD (Calculation of Phase Diagrams) type thermodynamic descriptions. These descriptions, in turn, are useful for modeling materials processing and predicting reactions such as oxide formation and fiber/matrix interactions. The leading experimental methods for measuring activities are the Galvanic cell or electro-motive force (EMF) technique and the KCMS technique. Each has specific advantages, depending on material and conditions. The EMF technique is suitable for lower temperature measurements, provided a suitable cell can be constructed. KCMS is useful for higher temperature measurements in a system with volatile components. In this paper, we briefly review the KCMS technique and identify the major experimental issues that must be addressed for precise measurements. These issues include temperature measurements, cell material and cell design and absolute pressure calibration. The resolution of these issues are discussed together with some recent examples of measured thermodynamic data.

Copland, Evan H.↗

Measurement Capabilities of Planar Doppler Velocimetry in Large-Scale Wind Tunnels

Over the past few years, Planar Doppler Velocimetry (PDT) has been shown by several laboratories to offer an attractive means for measuring three-dimensional velocity vectors everywhere in a light sheet placed in a flow. Unlike some other optical means of measuring flow velocities, PDT is particularly attractive for use in large wind tunnels where distances to the sample region may be several meters, because it does not require the spatial resolution and tracking of individual scattering particles or the alignment of crossed beams at large distances. To date, demonstrations of PDT (also called Doppler Global Velocimetry by some authors) have been made either in low speed flows without quantitative comparison to other measurements, or in supersonic flows where the Doppler shift is large and its measurement is relatively insensitive to instrumental errors. Moreover, most reported applications have relied on the use of continuous-wave lasers, which limit the measurement to time-averaged velocity fields. This work summarizes the results of two previous studies of PDT in which the use of pulsed lasers to obtain instantaneous velocity vector fields is evaluated. The objective has been to quantitatively define and demonstrate PDT capabilities for applications in large-scale wind tunnels that are intended primarily for the testing of rotorcraft and subsonic aircraft at speeds typically less than 100 m/s. For such applications, the adequate resolution of low-speed flow fields requires accurate measurements of small Doppler shifts that are obtained at distances of several meters from the sample region and with a field of view that is sufficient to encompass the entire region of interest. The use of pulsed lasers provides the unique capability to obtain not only time-averaged fields, but also their statistical fluctuation amplitudes and the spatial excursions of unsteady flow regions such as wakes, separations, and rotor-tip vortices. To accomplish the objectives of these studies, the PDT measurement process was first modeled and its performance evaluated computationally. The noise sources considered included those related to the optical and electronic properties of Charge-Coupled Device (CCD) arrays and to speckle effects associated with the coherent illumination of aerosols from pulsed lasers. The signal noise estimates were incorporated into the PDT signal analysis process and combined with computed scattering signals using a Mae scattering theory for a distributed range of aerosol particle sizes. The results are used to define the necessary instrument configuration, to show that the expected signal levels from a practical PDT system are sufficiently large to allow its useful application in large facilities, and to show that the expected velocity measurement uncertainties are small compared to the mean velocities of interest for most subsonic, large-scale wind tunnel testing, Experimental studies using several bench-top setups are then described that validate the physics of the PDT model and demonstrate the ability to obtain accurate PDT measurements using procedures that are compatible with large-scale wind tunnel operations. The PDT measurement capabilities found in this study lead to the conclusion that PDT offers significant advantages compared to other means of measuring velocity fields in large-scale wind tunnels, including those operating at low speeds.

McKenzie, Robert L.↗

Accuracy of quantum sensors measuring yield photon flux and photosynthetic photon flux

Photosynthesis is fundamentally driven by photon flux rather than energy flux, but not all absorbed photons yield equal amounts of photosynthesis. Thus, two measures of photosynthetically active radiation have emerged: photosynthetic photon flux (PPF), which values all photons from 400 to 700 nm equally, and yield photon flux (YPF), which weights photons in the range from 360 to 760 nm according to plant photosynthetic response. We selected seven common radiation sources and measured YPF and PPF from each source with a spectroradiometer. We then compared these measurements with measurements from three quantum sensors designed to measure YPF, and from six quantum sensors designed to measure PPF. There were few differences among sensors within a group (usually <5%), but YPF values from sensors were consistently lower (3% to 20%) than YPF values calculated from spectroradiometric measurements. Quantum sensor measurements of PPF also were consistently lower than PPF values calculated from spectroradiometric measurements, but the differences were <7% for all sources, except red-light-emitting diodes. The sensors were most accurate for broad-band sources and least accurate for narrow-band sources. According to spectroradiometric measurements, YPF sensors were significantly less accurate (>9% difference) than PPF sensors under metal halide, high-pressure sodium, and low-pressure sodium lamps. Both sensor types were inaccurate (>18% error) under red-light-emitting diodes. Because both YPF and PPF sensors are imperfect integrators, and because spectroradiometers can measure photosynthetically active radiation much more accurately, researchers should consider developing calibration factors from spectroradiometric data for some specific radiation sources to improve the accuracy of integrating sensors.

NASA Center KSC↗