Search NASA⌕ Search

SEARCH · Search NASA

Results for “measuring instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Does UV instrumentation effectively measure ozone abundance?

Measurements of O3 on Mars provide significant information about the chemistry and composition of the atmosphere, including long-term changes. The most extensive and accurate data were inferred from the Mariner 9 UV spectrometer experiment. Mars O3 shows strong seasonal and latitudinal variation, with column abundances ranging from 0.2 microns at equatorial latitudes to 60 microns over the northern winter polar latitudes (1 micron-atm is a column abundance of 2.689 x 10(exp 15) molecules cm(exp-2)). The Mariner 9 UV spectrometer scanned from 2100 to 3500 Angstroms in one of its two spectral channels every 3 seconds with a spectral resolution of 15 Angstroms and an effective field-of-view of approximately 300 km(exp 2). Measurements were made for almost half a Martian year, with winter and spring in the Northern Hemisphere and summer and fall in the Southern Hemisphere. The detectability limit of the spectrometer was approximately 3 microns of ozone. The UV spectrometer on Mariner 9 was incapable of penetrating the dust during dust storms; the single-scattering albedo and phase function of airborne dust and cloud ice are not known to the degree required to extract the small UV signal reflected up from near the surface. The reflectance spectroscopy technique would also have difficulty detecting the total column abundance of O3 in cases where large dust abundances exist together with the polar hood, especially at high latitudes where large solar zenith angles magnify those optical depths; yet these cases would contain the maximum O3, based on theoretical results. It is quite possible that the maximum O3 column abundance observed by Mariner 9 of 60 microns is common. In fact, larger quantities may exist in some of the colder areas with optically thick clouds and dust. As the Viking period often had more atmospheric dust loading than did that of Mariner 9, the reflectance spectroscopy technique may even have been incapable of detecting the entire O3 column abundance during much of the Mars year that Viking observed, particularly at high latitudes.

Lindner, Bernhard Lee↗

Instrumentation for Measurement of Gas Permeability of Polymeric Membranes

A mass spectrometric 'Dynamic Delta' method for the measurement of gas permeability of polymeric membranes has been developed. The method is universally applicable for measurement of the permeability of any gas through polymeric membrane materials. The usual large sample size of more than 100 square centimeters required for other methods is not necessary for this new method which requires a size less than one square centimeter. The new method should fulfill requirements and find applicability for industrial materials such as food packaging, contact lenses and other commercial materials where gas permeability or permselectivity properties are important.

Upchurch, Billy T.↗

Instrument for Measuring Cryo CTE

Coefficient of thermal expansion is an integral part of the performance of optical systems, especially for those, which operate at cryogenic temperatures. The measurement of the coefficient of relevant materials has been of continuous interest. Besides commercial measurement sources, development of one-of-a-kind tools have always been of interest due to local needs. This paper describes one such development at the University of Alabama in Huntsville (UAH). The approach involves two vertical rods (one sample and one reference) on a flat platform. A probe bar is held horizontally atop the two samples. A temperature change will generally cause rotation of the probe bar. A mirrored surface on one end of the probe bar is used to measure the rotation using the reflection of an incident laser beam upon it. A position-sensing detector measures the change of the reflected beam spot position. Using other known quantities, the change determines the coefficient of thermal expansion of the sample material as a function of temperature. A parallel measurement of the rotation of the sample support platform is also performed to account for any unwanted background effects. This system has been demonstrated in a cryogenic chamber at the NASA Marshall Space Flight Center X-ray Calibration Facility (XRCF). We present the system details, achievable sensitivity, and up-to-date experimental performance.

Vikram, Chandra S.↗

Instrument for Measuring Temperature of Water

A pseudo-Brewster angle infrared radiometer has been proposed for use in noncontact measurement of the surface temperature of a large body of water (e.g., a lake or ocean). This radiometer could be situated on a waterborne, airborne, or spaceborne platform. The design of the pseudo-Brewster angle radiometer would exploit the spectral emissivity and polarization characteristics of water to minimize errors attributable to the emissivity of water and to the reflection of downwelling (e.g., Solar and cloud-reflected) infrared radiation.

Ryan, Robert↗

PhyLM: A Mission Design Concept for an Optical/Lidar Instrument to Measure Ocean Productivity and Aerosols from Space

The Physiology Lidar-Multispectral Mission (PhyLM) is intended to explore the complex ecosystems of our global oceans. New "inversion" methods and improved understanding of marine optics have opened the door to quantifying a range of critical ocean properties. This new information could revolutionize our understanding of global ocean processes, such as phytoplankton growth, harmful algal blooms, carbon fluxes between major pools and the productivity equation. The new science requires new measurements not addressed by currently planned space missions. PhyLM will combine active and advanced passive remote sensing technologies to quantify standing stocks and fluxes of climate-critical components of the Ocean carbon cycle to meet these science providing multispectral bands from the far UV through the near infrared (340 - 1250 nm) at a ground resolution of 250 m. Improved detectors, filters, mirrors, digitization and focal plane design will offer an overall higher-quality data product. The unprecedented accuracy and precision of the absolute water-leaving radiances will support inversion- based quantification of an expanded set of ocean carbon cycle components. The dual- wavelength (532 & 1064 nm) Nd:Yag Lidar will enhance the accuracy and precision of the passive data by providing aerosol profiles for atmospheric correction and coincident active measurements of backscattering. The Lidar will also examine dark-side fluorescence as an additional approach to quantifying phytoplankton biomass in highly productive regions.

Gervin, Janette C.↗

AIRS Data Subsetting Service at the Goddard Earth Sciences (GES) DISC/DAAC

The AIRS mission, as a combination of the Atmospheric Infrared Sounder (AIRS), the Advanced Microwave Sounding Unit (AMSU) and the Humidity Sounder for Brazil (HSB), brings climate research and weather prediction into 21st century. From NASA' Aqua spacecraft, the AIRS/AMSU/HSB instruments measure humidity, temperature, cloud properties and the amounts of greenhouse gases. The AIRS also reveals land and sea- surface temperatures. Measurements from these three instruments are analyzed . jointly to filter out the effects of clouds from the IR data in order to derive clear-column air-temperature profiles and surface temperatures with high vertical resolution and accuracy. Together, they constitute an advanced operational sounding data system that have contributed to improve global modeling efforts and numerical weather prediction; enhance studies of the global energy and water cycles, the effects of greenhouse gases, and atmosphere-surface interactions; and facilitate monitoring of climate variations and trends. The high data volume generated by the AIRS/AMSU/HSB instruments and the complexity of its data format (Hierarchical Data Format, HDF) are barriers to AIRS data use. Although many researchers are interested in only a fraction of the data they receive or request, they are forced to run their algorithms on a much larger data set to extract the information of interest. In order to better server its users, the GES DISC/DAAC, provider of long-term archives and distribution services as well science support for the AIRS/AMSU/HSB data products, has developed various tools for performing channels, variables, parameter, spatial and derived products subsetting, resampling and reformatting operations. This presentation mainly describes the web-enabled subsetting services currently available at the GES DISC/DAAC that provide subsetting functions for all the Level 1B and Level 2 data products from the AIRS/AMSU/HSB instruments.

Vicente, Gilberto A.↗

Instrumentation and Measurements for Electron Emission from Charged Insulators

The electron was first discovered in 1898 by Sir John Joseph Thomson and has since been the subject of detailed study by nearly every scientific discipline. At nearly the same time Heinrich Rudolf Hertz conducted a series of experiments using cathode tubes, high potentials and ultraviolet light. When applying a large potential to a cathode he found that an arching event across the metal plates would occur. In addition, when shining an ultraviolet light on the metal he found that less potential was required to induce the spark. This result, taken together with other electrical phenomena brought about by the shining of light upon metal and was eventually termed the photoelectric effect. The work of Thomson and Hertz represent the beginning of electron emission studies and a body of ideas that pervade nearly all aspects of physics. In particular these ideas tell us a great deal about the nature of physical interactions within solids. In this thesis we will focus on the emission of electrons induced by an incident electron source over a range of energies, in which one can observe changes in emitted electron flux and energy distribution. In particular, when energetic particles impinge on a solid they can impart their energy, exciting electrons within the material. If this energy is sufficient to overcome surface energy barriers such as the work function, electron affinity or surface charge potential, electrons can escape from the material. The extent of electron emission from the material can be quantified as the ratio of incident particle flux to emitted particle flux, and is termed the electron yield.

Sim, Alec M.↗

Calibration of Instruments for Measuring Wind Velocity and Direction

Signal Corps wind equipment AN/GMQ-1 consisting of a 3-cup anemometer and wind vane was calibrated for wind velocities from 1 to 200 miles per hour. Cup-shaft failure prevented calibration at higher wind velocities. The action of the wind vane was checked and found to have very poor directional accuracy below a velocity of 8 miles per hour. After shaft failure was reported to the Signal Corps, the cup rotors were redesigned by strengthening the shafts for better operation at high velocities. The anemometer with the redesigned cup rotors was recalibrated, but cup-shaft failure occurred again at a wind velocity of approximately 220 miles per hour. In the course of this calibration two standard generators were checked for signal output variation, and a wind-speed meter was calibrated for use with each of the redesigned cup rotors. The variation of pressure coefficient with air-flow direction at four orifices on a disk-shaped pitot head was obtained for wind velocities of 37.79 53.6, and 98.9 miles per hour. A pitot-static tube mounted in the nose of a vane was calibrated up to a dynamic pressure of 155 pounds per square foot, or approximately 256 miles per hour,

Vogler, Raymond D.↗

Instrument for Measuring Thermal Conductivity of Materials at Low Temperatures

With the advance of polymer and other non-metallic material sciences, whole new series of polymeric materials and composites are being created. These materials are being optimized for many different applications including cryogenic and low-temperature industrial processes. Engineers need these data to perform detailed system designs and enable new design possibilities for improved control, reliability, and efficiency in specific applications. One main area of interest is cryogenic structural elements and fluid handling components and other parts, films, and coatings for low-temperature application. An important thermal property of these new materials is the apparent thermal conductivity (k-value).

Fesmire, James↗

Instrument for Measuring Temperature of Water

A pseudo-Brewster-angle infrared radiometer has been proposed for use in noncontact measurement of the surface temperature of a large body of water (e.g., a lake or ocean). This radiometer could be situated on a waterborne, airborne, or spaceborne platform. The design of the pseudo-Brewster-angle radiometer would exploit the spectral-emissivity and polarization characteristics of water to minimize errors attributable to the emissivity of water and to the reflection of downwelling (e.g., Solar and cloud-reflected) infrared radiation. The relevant emissivity and polarization characteristics are the following: . The Brewster angle is the angle at which light polarized parallel to the plane of incidence on a purely dielectric material is not reflected. The pseudo-Brewster angle, defined for a lossy dielectric (somewhat electrically conductive) material, is the angle for which the reflectivity for parallel-polarized light is minimized. For pure water, the reflectivity for parallel-polarized light is only 2.2 x 10(exp -4) at its pseudo- Brewster angle of 51deg. The reflectivity remains near zero, several degrees off from the 51deg optimum, allowing this angle of incidence requirement to be easily achieved. . The wavelength range of interest for measuring water temperatures is 8 to 12 microns. The emissivity of water for parallel- polarized light at the pseudo-Brewster angle is greater than 0.999 in this wavelength range. The radiometer would be sensitive in the wavelength range of 8 to 12 microns, would be equipped with a polarizer to discriminate against infrared light polarized perpendicular to the plane of incidence, and would be aimed toward a body of water at the pseudo- Brewster angle (see figure). Because the infrared radiation entering the radiometer would be polarized parallel to the plane of incidence and because very little downwelling parallel-polarized radiation would be reflected into the radiometer on account of the pseudo-Brewster arrangement, the radiation received by the radiometer would consist almost entirely of thermal emission from the surface of the water. Because the emissivity of the water would be very close to 1, the water could be regarded as a close approximation of a blackbody for the purpose of computing its surface temperature from the radiometer measurements by use of the Planck radiation law.

Ryan, Robert↗

In-situ Raman Instrumentation and Measurements in Supercritical Water Oxidation Systems

Due to the advent of recent advances in reactor designs and operational procedures, renewed attention has been given to a host of supercritical water oxidation (SCWO) technology applications. This includes resource recovery, water reclamation, and solid waste destruction. SCWO is often recognized as a “green technology” because of its ability to extract useful energy while producing benign products from environmentally challenging waste streams (e.g., wet organic wastes, pharmaceutical wastes, military wastes). The present work was motivated by NASA’s interests in solid waste management and water recovery for long-duration space missions. To that end, the main focus of this paper is to present work on characterizing the behavior of supercritical water oxidation systems utilizing state of the art laser Raman spectroscopy. The main benefit of Raman diagnostics is its ability to identify chemical composition and to measure concentrations of the compounds involved in the reaction. Two separate Raman systems for SCWO measurements that have been developed for this study will be described. The first system is a 2-D traversing system useful for making in-situ measurements in conditions where spatial gradients of species and temperature are important and has been successfully utilized in making species (ethanol, oxygen, water, nitrogen and carbon dioxide) concentrations and temperature measurements in ethanol hydrothermal jet flames. The second system is a packaged modular Raman probe unit for portable deployment to different reactors and is more suitable for relatively homogeneous systems such as a batch reactor. The design, development, and examples of obtained results from both systems will be presented for various reactant streams. Reaction rate and fuel conversion estimates from chemistry models will also be presented.

supercritical water oxidation↗