Refining Principal Stress Measurements in Reservoir Underburden in Regions of Induced Seismicity through Seismological Tools, Laboratory Experiments - Final Technical Report

This project developed methodologies to measure the in-situ principal stress in the deep subsurface through use of multiple independent, but complementary, seismic methods, laboratory verification, and development of theoretical frameworks. By leveraging existing regional and local datasets we developed, tested, and refined a set of diagnostic tools for determining the in-situ stress state with reduced uncertainty at and below reservoir depths (1.5-6 km). A set of novel tools was produced that are scale independent, such that their utility is equivalent on regional, field scale, and near borehole monitoring of principal stresses in reservoir underburden for carbon storage projects. During a 4-year Department of Energy (DOE) and Southern Company funded project, carried out by the Electric Power Research Institute (EPRI), Lawrence Livermore National Laboratory (LLNL), the University of Oklahoma (OU), and the U.S. Geological Survey (USGS), the project team developed methodologies to measure the far-field in-situ principal stress in the deep subsurface, leveraging induced seismicity data from waste-water disposal projects. These methodologies consisted in the use of well-established and technically advanced seismic processing methods, such as virtual seismometer method-moment tensor (VSM-MT) and shear wave splitting (SWS), that are adept at recovering the stress orientation and certain components of the stress tensor. These methods were applied to robust seismicity catalogs created with matched filter techniques near sites of active fluid disposal—a proxy for carbon storage sites where such datasets are more limited. Estimates of the stress orientation made with seismic processing tools were considered along with laboratory acoustic emission experiments conducted on rock samples from the region of interest. Stress orientations in the studied region do not vary significantly across distances of ~100 km, nor are they found to rotate through time as a consequence of local wastewater disposal, as previously speculated. Finally, the project team investigated the trade-offs among the different seismic methods and evaluated the range of uncertainty that is generated with these methodologies, which led to a practical use and refinement of the VSM-MT technique when it is applied to field datasets. Understanding the trade-offs between these different methods highlighted the potential benefits of improved quantification of uncertainties on stress field estimations.

58 GEOSCIENCES↗

Online charge measurement for petawatt laser-driven ion acceleration

Laser-driven ion beams have gained considerable attention for their potential use in multidisciplinary research and technology. Preclinical studies into their radiobiological effectiveness have established the prospect of using laser-driven ion beams for radiotherapy. In particular, research into the beneficial effects of ultrahigh instantaneous dose rates is enabled by the high ion bunch charge and uniquely short bunch lengths present for laser-driven ion beams. Such studies require reliable, online dosimetry methods to monitor the bunch charge for every laser shot to ensure that the prescribed dose is accurately applied to the biological sample. In this paper, we present the first successful use of an Integrating Current Transformer (ICT) for laser-driven ion accelerators. This is a noninvasive diagnostic to measure the charge of the accelerated ion bunch. It enables online estimates of the applied dose in radiobiological experiments and facilitates ion beam tuning, in particular, optimization of the laser ion source, and alignment of the proton transport beamline. We present the ICT implementation and the correlation with other diagnostics, such as radiochromic films, a Thomson parabola spectrometer, and a scintillator.

47 OTHER INSTRUMENTATION↗

Analytics-at-scale of Sensor Data for Digital Monitoring in Nuclear Plants: 2nd Annual Report

For economic reasons, the nuclear industry is witnessing premature closure of nuclear power plants, despite excellent safety records. Operations and Maintenance (O&M) activities are some of the largest costs in operating legacy light-water plants. By reducing O&M costs, nuclear energy can become more economically competitive with other energy sources. This can be achieved by leveraging machine-learning and artificial intelligence technologies to develop data-driven algorithms to better diagnose potential faults within the system. Improved accuracy of the models can lead to a reduction in unnecessary maintenance, thus reducing costs associated with parts, labor, and unnecessary planned, forced, or extended outages. To address these challenges, the goal of this project is to perform research and development in the area of digital monitoring, i.e., the application of advanced sensor technologies (particularly wireless sensor technologies) and data science based analytic capabilities, to advance online monitoring and predictive maintenance in nuclear plants and improve plant performance (efficiency gain and economic competitiveness). This report summarizes the fiscal year 2020 research progress encompassing (1) different wireless vibration sensor and data indicators used to assess the health of a plant asset; (2) development of diagnostic models for fault detection; and (3) development of prognostic models for estimating the health of the system up to 7 days ahead.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Studies of laser stimulated photodetachment from nanoparticles for particle charge measurements

Determining nanoparticle charge is more challenging than that for microparticles due to change in the particle size during the synthesis substantial plasma property variations, and difficulties in visualizing individual particles, rendering conventional microparticle charge diagnostics ineffective in dusty plasma. In this work, we utilized laser-stimulated photodetachment (LSPD) to deduce the mean charge of nanoparticles. Nanoparticles were grown in an Ar/C 2 H 2 mixture using a capacitively coupled RF discharge and the LSPD induced changes in the electron current monitored by a cylindrical Langmuir probe. LSPD signals were obtained and analyzed across different dust growth phases. The prolonged decay of electron current pulses was attributed to the presence of residual negative ions, caused by the effective electrostatic trapping of these ions and the potential post—LSPD re-formation of new ones. The particle charge was estimated by combining the laser-stimulated photodetachment signal from the probe with the dust density obtained from laser-light extinction using the measured nanoparticle size distribution. For a nanoparticles size range of approximately 100–250 nm and mean diameter of $d$ p ∼154.37 nm, the effective mean charge was estimated to be $\langle$$Q$$\rangle$ d $≈$ 37 elementary charge units. The measured charge values are lower than those predicted by orbital motion limited theory, which may be attributed to significant electron depletion in the nanodusty plasma. LSPD results in Ar/C 2 H 2 nano-dusty plasma confirm the applicability of this method for estimating individual nanoparticle charges. However, it has also been demonstrated that electron detachment from residual background negative ions can influence the detachment current decay and must be carefully considered.

dust particle charge↗

A Conceptual Framework for HPC Operational Data Analytics

This paper provides a broad framework for under- standing trends in Operational Data Analytics (ODA) for High- Performance Computing (HPC) facilities. The goal of ODA is to allow for the continuous monitoring, archiving, and analysis of near real-time performance data, providing immediately actionable information for multiple operational uses. In this work, we combine two models to provide a comprehensive HPC ODA framework: one is an evolutionary model of analytics capabilities that consists of four types, which are descriptive, diagnostic, predictive and prescriptive, while the other is a four- pillar model for energy-efficient HPC operations that covers facility, system hardware, system software, and applications. This new framework is then overlaid with a description of current development and production deployments of ODA within leading- edge HPC facilities. Finally, we perform a comprehensive survey of ODA works and classify them according to our framework, in order to demonstrate its effectiveness.

Netti, Alessio↗

An X-ray Intensity Operations Monitor (AXIOM) (Final LDRD Project Report)

The Saturn accelerator has historically lacked the capability to measure time-resolved spectra for its 3-ring bremsstrahlung x-ray source. This project aimed to create a spectrometer called AXIOM to provide this capability. The project had three major development pillars: hardware, simulation, and unfold code. The hardware consists of a ring of 24 detectors around an existing x-ray pinhole camera. The diagnostic was fielded on two shots at Saturn and over 100 shots at the TriMeV accelerator at Idaho Accelerator Center. A new Saturn x-ray environment simulation was created using measured data to validate. This simulation allows for timeresolved spectra computation to compare the experimental results. The AXIOM-Unfold code is a new parametric unfold code using modern global optimizers and uncertainty quantification. The code was written in Python, uses Gitlab version control and issue tracking, and has been developed with long term code support and maintenance in mind.

43 PARTICLE ACCELERATORS↗

Surface normal emissivity measurements in uncoated and oxidized B-coated plasma facing component materials in the long wavelength infrared spectrum

Accurate surface emissivity measurements are integral to the fidelity of the infrared thermography diagnostic evaluation in fusion reactors. The emissivities of ATJ TM graphite, Sigrafine® (R6510) graphite, and TZM alloy were measured as a function of temperature in accordance with the Contact Thermometer Method in the ASTM E1933 standard. Samples were heated resistively in a high-vacuum chamber, and the surface temperature was monitored using a surface thermocouple and a Telops long-wavelength infrared camera. The surfaces of Sigrafine® graphite and TZM alloy samples were coated with 10 nm and 20 nm layers of oxidized boron and were also measured in the uncoated condition. The thickness was assessed from measurement by a quartz crystal microbalance (QCM). ATJ TM graphite was uncoated. The measured emissivity of ATJ TM Graphite ranged from 0.82 to 0.83, uncoated Sigrafine® graphite ranged from 0.76 to 0.98, and uncoated TZM alloy ranged from 0.11 to 0.13. Oxidized boron coatings increased the emissivity of the TZM alloy to 0.18–0.23 but decreased the emissivity of Sigrafine® graphite to 0.56–0.66 for a 10 nm coating and to 0.65–0.74 for a 20 nm coating. In contrast to the expected blackbody radiance, the emissivity of uncoated Sigrafine® graphite and TZM alloy did not monotonically increase with temperature from 100 to 500 ℃.

Emissivity↗

A digital twin approach to system-level fault detection and diagnosis for improved equipment health monitoring

Automating the task of fault detection and diagnosis is crucial in the effort to reduce the operation and maintenance cost in the nuclear industry. This paper describes a physics-based approach for system-level diagnosis in thermal-hydraulic systems in nuclear power plants. The inclusion of physics information allows for the creation of virtual sensors, which provide improved fault diagnosis capability. The physics information also serves to better constrain diagnostic solutions to the physical domain. As a demonstration, various test cases for fault diagnosis in a high-pressure feedwater system were considered. The use of virtual sensors allows constructing performance models for two first-point feedwater heaters which would not have been possible otherwise due to the limited sensor set. Real-time plant data provided by a utility partner were used to assess the diagnostic approach. The detection of an abnormal event immediate after a plant startup pointed to faulty behaviors in the two first-point feedwater heaters. Further, this double-blind fault diagnosis was subsequently confirmed by the plant operator. In addition, several simulated sensor fault events demonstrated the capability of our algorithms in detecting and discriminating sensor faults.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Optimizing Hydronic Heating for Comfort and Performance in Multifamily Housing

Inefficient control settings in multifamily boilers often lead to substantial energy and cost penalties. To address this, a Fault Detection and Diagnostic (FDD) tool was developed to automate data analysis and identify operational faults such as suboptimal outdoor temperature sensor placement, misconfigured outdoor air reset (OAR) curves, excess boiler cycling, and domestic hot water (DHW) setpoint errors. By comparing pre- and post-implementation periods and applying engineering models, the tool quantifies energy savings and reduces manual analysis time by over 90%. Testing on over 100 monitored sites and a targeted subset of 12 buildings showed an average 11% energy savings from remote optimization; further validation across 19 OAR curve changes confirmed the tool’s accuracy, predicting actual savings within ±5% for most cases. Simple payback can be under three years for many multifamily buildings, though rising hardware, labor, and fuel costs create uncertainties, and decarbonization goals increasingly shift focus to electrification. The FDD tool remains invaluable for optimizing existing boilers, enhancing future electrification measures, and adapting to new technologies by refining building load estimates. In doing so, it supports both near-term efficiency and long-term transitions to low-carbon alternatives, ensuring buildings achieve substantial cost and energy benefits throughout their system lifecycles.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

CAN-D: A Modular Four-Step Pipeline for Comprehensively Decoding Controller Area Network Data

Controller area networks (CANs) are a broadcast protocol for real-time communication of critical vehicle subsystems. Original equipment manufacturers of passenger vehicles hold secret their mappings of CAN data to vehicle signals, and these definitions vary according to make, model, and year. Without these mappings, the wealth of real-time vehicle information hidden in the CAN packets is uninterpretable, severely impeding vehicle-related research, including CAN cybersecurity and privacy studies, aftermarket tuning, efficiency and performance monitoring, and fault diagnosis to name a few. Guided by the four-part CAN signal definition, we present CAN-D (CAN-Decoder), a modular, four-step pipeline for identifying each signal's boundaries (start bit and length), endianness (byte ordering), signedness (bit-to-integer encoding), and by leveraging diagnostic standards, augmenting a subset of the extracted signals with meaningful, physical interpretation. En route to CAN-D, we provide a comprehensive review of the CAN signal reverse engineering research. All previous methods ignore endianness and signedness, rendering them incapable of decoding many standard CAN signal definitions. Incorporating endianness grows the search space from 128 to 4.72E21 signal tokenizations and introduces a web of changing dependencies. In response, we formulate, formally analyze, and provide an efficient solution to an optimization problem, allowing identification of the optimal set of signal boundaries and byte orderings. In addition, we provide two novel, state-of-the-art signal boundary classifiers—both of which are superior to previous approaches in precision and recall in three different test scenarios—and the first signedness classification algorithm, which exhibits a $>$ 97% F-score. Altogether, CAN-D is the only solution with the potential to extract any CAN signal that is also the state of the art. In evaluation on 10 vehicles of different makes, CAN-D's average $\ell ^1$ error is five times better (81% less) than all previous methods and exhibits lower average error, even when considering only signals that meet prior methods’ assumptions. Finally, CAN-D is implemented in lightweight hardware, allowing for an on-board diagnostic (OBD-II) plugin for real-time in-vehicle CAN decoding.

42 ENGINEERING↗

Real-Time Monitoring of Fracture Dynamics with a Contrast Agent-Assisted Electromagnetic Method

In collaboration with the Advanced Energy Consortium, our team has previously demonstrated that the placement of electrically active proppants (EAPs) in a hydraulic fracture surveyed by electromagnetic (EM) methods can enhance the imaging of the stimulated reservoir volumes during hydraulic fracturing. That work culminated in constructing a well-characterized EAP-filled fracture anomaly at the Devine field pilot site (DFPS). In subsequent laboratory studies, we observed that the electrical conductivity of our EAP correlates with changes in pressure, salinity, and flow. Thus, we postulated that the EAP could be used as an in-situ sensor for the remote monitoring of these changes in previously EAP-filled fractures. This paper presents our latest field data from the DFPS to demonstrate such correlations at an intermediate pilot scale. We conducted surface-based EM surveys during freshwater (200 ppm) and saltwater (2,500 ppm) slug injections while running surfaced-based EM surveys. Simultaneously, we measured the following: 1) bottomhole pressure and salinity in five monitoring wells; 2) injection rate using high-precision data loggers; 3) distributed acoustic sensors in four monitoring wells; and 4) tiltmeter data on the survey area. We demonstrated that injections into an EAP-filled fracture could be successfully coupled with real-time electric field measurements on the surface, leading to remote monitoring of dynamic changes within the EAP-filled fracture. Furthermore, by comparing the electrical field traces with the bottomhole pressure, flow rate, and salinity, we concluded that the observed electric field in our study is influenced by fracture dilation and flow rate. Salinity effect was observed when saltwater was injected. EM simulations solely based on assumptions of fracture conductivity changes during injection did not reproduce all of the measured electric field magnitudes. Preliminary estimates showed that including streaming potential in our geophysical model may be needed to reduce the simulation mismatch. The methods developed and demonstrated during this study will lead to a better understanding of the extent of fracture networks, formation stress states, fluid leakoff and invasion, characterizations of engineered fracture systems, and other applications where monitoring subsurface flow tracking is deemed important.

02 PETROLEUM↗

Catalyst Layer Design, Manufacturing and In-line Quality Control

In this project we successfully demonstrated the capabilities of the Reactive Spray Deposition Technology (RSDT) to fabricate large-scale CCMs for advanced PEMWEs that have one-order of magnitude lower PGM loading in their catalyst layers, and performance comparable with the commercial state-of-the-art CCMs. The RSDT is a unique methodology that combines the catalyst synthesis and CCM fabrication in one step and reduces dramatically the time for CCM manufacturing. As fabricated large-scale CCMs with geometric area of 680 cm2 demonstrated excellent activity and durability performance, and the novel duo-recombination layer design paves the way for solving the safety concerns related to PEMWEs. In addition, excellent activity and durability performance has been demonstrated with RSDT fabricated CCMs with thinner membranes and duo RL design. This is a novel approach for further performance improvement of the MEAs for PEMWEs that has been successfully demonstrated for the first time in this project. The integration of the in-situ laser diagnostics system along with the in-line optical quality control system within the RSDT that has been achieved and demonstrated in this project, is an example for possibility of designing and building advanced manufacturing technologies that can meet the requirements of the future manufacturing. Therefore, the RSDT offers a precise real-time monitoring and control of the particles size, composition, loading, porosity, thickness, and defects in the catalysts’ layers, which render this technology as the best candidate for manufacturing of cost effective CCMs for PEMWEs. By using RSDT we successfully met all project’s milestones, Go/No-Go decision, objectives, goals, and deliverables.

08 HYDROGEN↗

Measurement of engine-oil fuel dilution using laser induced florescence spectroscopy

An optical diagnostic, based on laser-induced fluorescence (LIF), has been developed for on-engine measurements of real-time fuel dilution of engine oil, or fuel in oil (FiO). Fuel dilution of oil is believed to be one of the underlying mechanisms that promotes low speed pre-ignition (LSPI) during high-load engine operations. While standard (e.g., ASTM D3524-90) methods are not capable of transient measurements, the LIF technique resolves transient dilution on the minutes time scale, making it possible to study the relation between FiO and LSPI. The measurement is based on adding a dye (ca. 500 ppm) to the fuel and monitoring for its presence in the oil via LIF. The instrument contains a 532-nm laser diode, and a spectrometer to resolve the LIF spectra. A fiber-optic assembly links the instrument to the engine measurement location; the probe is in a Y-configuration with the six fibers around one on a common probe end that connects to the engine; the Y-assembly legs are connected to the instrument; the two legs are the six fibers for transporting the laser light, and the single fiber for the fluorescence. We have expanded on our previous work (Parks et al, SAE paper 2007-01-4108, 2007), by demonstrating the diagnostic technique with to measure transient oil dilution on a 2.0-liter GM ECOTEC LNF single cylinder SI engine. The proposed LIF diagnostic will be critical in studying oil-dilution correlation with LSPI events.

Neupane, Sneha↗

Design of BLDC Motor Diagnostic Device Based on Surge Test for Phase to Ground Fault

BLDC motor is essential in the industrial world, especially it been used for an electric vehicle. The benefit of using BLDC motor is that it has high rate efficiency and low mechanical losses. However, to know the isolation condition of winding and increase reliability, it needs to be tested. With the implementation of surge test based fault detection device of BLDC motor, the condition of BLDC motor can be monitored and maintained according to analysis of its condition. The surge test method used because it is sensitive in detecting the initial damage in the isolation failure process on stator winding. A surge voltage is generated from the Cockroft-Walton and switching circuit with capacitors. The result is analyzed using Error Area Ratio (EAR). The test result shows that the higher the value of resistance and inductance, the smaller the frequency of the surge wave. When the BLDC motor in a parallel short circuit condition, the threshold value of the EAR test-reff has a minimum value of 5.28%, an average of 13.52%, and a maximum of 28.55%.

BLDC motor↗

Automation of Nanoparticle Synthesis Processes in a Plasma Environment Using LabVIEW

This work presents an automated control system for the synthesis of nanomaterials by plasma-enhanced chemical vapor deposition (PECVD), implemented using the LabVIEW software environment. The main objective of the study is to develop an integrated hardware-software platform that enables sequential control of the key stages of the PECVD process, including vacuum chamber preparation, pressure monitoring, working gas supply, plasma ignition, power matching, cyclic nanomaterial growth, and optical monitoring of nanoparticles in the plasma environment. The use of LabVIEW made it possible to integrate actuator control, experimental parameter acquisition, and realtime process visualization within a single automated system. The automated cycle begins with evacuation of the reaction chamber to a predefined base pressure. Transition to the next stage is permitted only after the specified pressure threshold has been reached, ensuring reproducible initial conditions for each experiment. The program then controls the supply of the working gas through mass flow controllers (MFCs). In this work, two gas-flow control modes were considered: analog control using a 0-5 V voltage signal and digital communication via RS-232 interface. It was shown that the analog approach requires accurate scaling of the control voltage, since applying 5 V corresponds to full-scale opening of the controller and results in the maximum gas flow. In contrast, the RS232 interface enables the gas flow rate to be specified directly in sccm, improving the accuracy, flexibility, and convenience of gas-environment control. After pressure stabilization, LabVIEW initiates RF plasma ignition and executes the RF matching algorithm aimed at minimizing reflected power and improving the stability of the plasma process. A separate software module implements the cyclic nanomaterial growth mode, in which the plasma-on time, plasma duration, and total number of synthesis cycles are predefined. This approach makes it possible to control material accumulation on the substrate and to correlate the process parameters with the morphological characteristics of the resulting nanostructures. The final module of the system is designed for optical monitoring of the nanoparticle cloud density in dusty plasma. For this purpose, the change in the intensity of laser radiation passing through the plasma region is recorded using a photodetector and a Keithley 2401 measuring unit connected to LabVIEW via RS-232 interface. The difference between the initial and modified optical signal intensity is used as a diagnostic parameter characterizing the formation and temporal evolution of nanoparticles. The developed system demonstrates that LabVIEW can be effectively applied not only for the automation of individual instruments, but also for the implementation of a complete digital control cycle for PECVD-based nanomaterial synthesis.

PECVD↗

Effects of delta ray electrons on measurement uncertainties of harp system

A harp system, which is a multi-wire beam profile monitoring (MWPM) system, is planned upstream of the spallation target to make in situ calibration of beam current density configuration on the target along with beam imaging from luminescent coating on the beam entrance window at the Second Target Station (STS) of the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL). This beam interception-based beam diagnostics system on the target will be used to ensure that the maximum beam loads on the target are within the design range during neutron production. Current design of the harp consists of three layers of measurement wires each of which is sandwiched between voltage biasing wire planes. The signal obtained from each measurement wire layer is disturbed by secondary electrons (SE) and delta rays produced by beam-matter interactions in neighboring wires and ionization of residual gases in accelerator vacuum. While the backgrounds from SE can be suppressed by voltage biasing, the delta-ray electrons with kinetic energies above keV ranges overcome the electric potential bias. In this paper, we study the effects of delta-rays on the measurement uncertainties of MWPM using the particle transport simulation code FLUKA. Furthermore, the cases where the harp system is installed in the proximity of a large delta ray sources such as proton beam window or in the core vessel filled with sub-atmospheric gas have been studied.

Lee, Yong Joong↗

Advanced Physics-Based Fluid System Performance Monitoring to Support Nuclear Power Plant Operations. Final CRADA report

This project targeted performance monitoring requirements for nuclear power plants with the goal of improving plant economics. We introduced a new and innovative technology to the industry that can reduce operations staffing levels by automating surveillance and can reduce maintenance staffing levels by providing early detection of degrading equipment. A beta-stage release of the PRO-AID power plant equipment fault diagnostic software ready for deployment in nuclear power plants will be delivered and demonstrated in a utility pilot project. To provide for efficient use of DOE funds the aim is to generate a minimum viable product for which we can prove the value of the product. The end state product will be serviceable for use in either a simulator environment or plant environment. The former provides a means for demonstration of the diagnostic capability for faults unlikely to be encountered in day-to-day operations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Methods and algorithms of cyclic coulometry

Systems, devices, and methods of diagnosing an electrochemical cell using cyclic coulometry are discussed. An exemplary battery diagnostic system comprises a current generator to generate symmetric charge current and discharge current to excite an electrochemical cell, and a cyclic coulometer to evaluate performance of the electrochemical cell. The cyclic coulometer can adjust at least one of a charge time for applying the charge current, or a discharge time for applying the discharge current, to keep a monitored cell voltage toward a specific setpoint. The adjustment of charge or discharge time can be achieved by changing a current switch timing for reversing current from a first to a second current direction. The cyclic coulometer measures one or more electrical parameters during the charge or discharge cycle, and generates a performance metric using the measured electrical parameters.