Search NASA⌕ Search

SEARCH · Search NASA

Results for “nuclear pulse processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

A Compact Fusion–Fission Hybrid Reactor

Up today, two hyper research projects to achieve nuclear fusion energy exist; inertial confinement fusion (ICF) driven by laser, called national ignition facility (NIF) and magnetic confinement fusion the international thermonuclear experimental reactor (ITER) project. In reaching the required temperature and pressure, to ignite nuclear fusion reactor, is technologically complex and economically expensive. Thus, a breakthrough and a short cut, other alternative methods should be considered. Pulsed power ICF driver with repetitive pulse operation, mainly dense plasma focus (DPF) machines for high yield fusion neutrons could be taken as drivers for the fission blanket operation. The setup can be a cost-effective and efficient. In this article, we consider a set of two medium energy sizes DPF to produce simultaneously dense plasma columns, operating as thermonuclear plasma driver, to pierce the pellet target for external nuclear fusion reactions. These DPFs produce sufficient fast neutrons for the fission process in the neutral uranium or thorium and/or weak enriched uranium blanket. The drive systems and the concept for delivering thermonuclear plasma to pellets target in the magnetic free zone of central region will be presented. The feasibility of such fusion–fission hybrid reactor will be discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optical control of ultrafast structural dynamics in a fluorescent protein

The photoisomerization reaction of a fluorescent protein chromophore occurs on the ultrafast timescale. The structural dynamics that result from femtosecond optical excitation have contributions from vibrational and electronic processes and from reaction dynamics that involve the crossing through a conical intersection. The creation and progression of the ultrafast structural dynamics strongly depends on optical and molecular parameters. When using X-ray crystallography as a probe of ultrafast dynamics, the origin of the observed nuclear motions is not known. Now, high-resolution pump–probe X-ray crystallography reveals complex sub-ångström, ultrafast motions and hydrogen-bonding rearrangements in the active site of a fluorescent protein. However, we demonstrate that the measured motions are not part of the photoisomerization reaction but instead arise from impulsively driven coherent vibrational processes in the electronic ground state. A coherent-control experiment using a two-colour and two-pulse optical excitation strongly amplifies the X-ray crystallographic difference density, while it fully depletes the photoisomerization process. A coherent control mechanism was tested and confirmed the wave packets assignment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Time-of-flight vs time-of-arrival in neutron spectroscopic measurements for high energy density plasmas

The neutron time-of-flight (nToF) diagnostic technique has a lengthy history in Inertial Confinement Fusion (ICF) and High Energy Density (HED) Science experiments. Its initial utility resulted from the simple relationship between the full width half maximum of the fusion peak signal in a distant detector and the burn averaged conditions of an ideal plasma producing the flux [Lehner and Pohl, Z. Phys. 207, 83–104 (1967)]. More recent precision measurements [Gatu-Johnson et al., Phys. Rev. E 94(8), 021202 (2016)] and theoretical studies [Munro, Nucl. Fusion 56, 035001 (2016)] have shown the spectrum to be more subtle and complicated, driving the desire for an absolute calibration of the spectrum to disambiguate plasma dynamics from the conditions producing thermonuclear reactions. In experiments where the neutron production history is not well measured, but the neutron signal is preceded by a concomitant flux of photons, the spectrum can be in situ calibrated using a set of collinear detectors to obtain a true “time-of-flight” measurement. This article presents the motivation and overview of this technique along with estimates of the experimental precision needed to make useful measurements in existing and future nToF systems such as the pulsed power Z-machine located in Albuquerque, NM, at Sandia National Laboratories.

Fusion experiments↗

Photon-In/Photon-Out X-ray Free-Electron Laser Studies of Radiolysis

Understanding the origin of reactive species following ionization in aqueous systems is an important aspect of radiation–matter interactions as the initial reactive species lead to production of radicals and subsequent long-term radiation damage. Tunable ultrafast X-ray free-electron pulses provide a new window to probe events occurring on the sub-picosecond timescale, supplementing other methodologies, such as pulse radiolysis, scavenger studies, and stop flow that capture longer timescale chemical phenomena. We review initial work capturing the fastest chemical processes in liquid water radiolysis using optical pump/X-ray probe spectroscopy in the water window and discuss how ultrafast X-ray pump/X-ray probe spectroscopies can examine ionization-induced processes more generally and with better time resolution. Ultimately, these methods will be applied to understanding radiation effects in complex aqueous solutions present in high-level nuclear waste.

47 OTHER INSTRUMENTATION↗

SISGR: Physical Chemistry of Reaction Dynamics in Ionic Liquids

Room temperature ionic liquids (RTILs) are liquids made up of atomic and molecular ions. This is in contrast with more common liquids, such as water, that are made up of neutral molecules. The additional charges on the atoms and molecules can alter the properties of these liquids, for example they tend to have a very high vapor pressure and the ability to shield charge in electronic devices. For these and other reasons RTILs have recently been deployed in a number of applications that involve production of free electrons in the liquid, such as batteries, capacitors, nuclear power plants, and solar cells. Electrons tend to be very reactive, and understanding their behaviour in these liquids is important for the future design of ionic liquids to be employed in these environments. This study investigated the behavior of electrons generated in RTILs by pulses of ultraviolet light, including how long they survive, and how reactive they are with the both the surrounding liquid and impurities in the liquid. The ionic liquid studied was one of the most commonly used, called N-alkyl-N-methyl-pyrrolidinium bistriflimide. What the study revealed was that the majority of the electrons initially created, about 96%, had a very short lifetime of less than one picosecond (10-12 second) due to a process called geminate recombination. The study also demonstrated that the electrons are very reactive at the moment they are detached from the molecules in the liquid by light, but that they relax very quickly and lose almost all of their reactivity in much less than one picosecond. The short lifetime and rapid loss of reactivity both serve as important mechanisms that protect the liquid from radiolytic damage.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Waste Treatment Plant - 12508

The Waste Treatment Plant (WTP) will immobilize millions of gallons of Hanford's tank waste into solid glass using a proven technology called vitrification. The vitrification process will turn the waste into a stable glass form that is safe for long-term storage. Our discussion of the WTP will include a description of the ongoing design and construction of this large, complex, first-of-a-kind project. The concept for the operation of the WTP is to separate high-level and low-activity waste fractions, and immobilize those fractions in glass using vitrification. The WTP includes four major nuclear facilities and various support facilities. Waste from the Tank Farms is first pumped to the Pretreatment Facility at the WTP through an underground pipe-in-pipe system. When construction is complete, the Pretreatment Facility will be 12 stories high, 540 feet long and 215 feet wide, making it the largest of the four major nuclear facilities that compose the WTP. The total size of this facility will be more than 490,000 square feet. More than 8.2 million craft hours are required to construct this facility. Currently, the Pretreatment Facility is 51 percent complete. At the Pretreatment Facility the waste is pumped to the interior waste feed receipt vessels. Each of these four vessels is 55-feet tall and has a 375,000 gallon capacity, which makes them the largest vessels inside the Pretreatment Facility. These vessels contain a series of internal pulse-jet mixers to keep incoming waste properly mixed. The vessels are inside the black-cell areas, completely enclosed behind thick steel-laced, high strength concrete walls. The black cells are designed to be maintenance free with no moving parts. Once hot operations commence the black-cell area will be inaccessible. Surrounded by black cells, is the 'hot cell canyon'. The hot cell contains all the moving and replaceable components to remove solids and extract liquids. In this area, there is ultrafiltration equipment, cesium-ion exchange columns, evaporator boilers and recirculation pumps, and various mechanical process pumps for transferring process fluids. During the first phase of pretreatment, the waste will be concentrated using an evaporation process. Solids will be filtered out, and the remaining soluble, highly radioactive isotopes will be removed using an ion-exchange process. The high-level solids will be sent to the High-Level Waste (HLW) Vitrification Facility, and the low activity liquids will be sent to the Low-Activity Waste (LAW) Vitrification Facility for further processing. The high-level waste will be transferred via underground pipes to the HLW Facility from the Pretreatment Facility. The waste first arrives at the wet cell, which rests inside a black-cell area. The pretreated waste is transferred through shielded pipes into a series of melter preparation and feed vessels before reaching the melters. Liquids from various facility processes also return to the wet cell for interim storage before recycling back to the Pretreatment Facility. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Release of the 2008 Evaluated Nuclear Data Library (ENDL2008)

Livermore's N-Division is now releasing the first version of a major new nuclear data library. This includes some 500 evaluations (roughly four times the number in the previous standard) and many physics improvements important for calculating weapon performance, output effects, attribution signatures, key radiochemical diagnostics and performance of conventional and hybrid fission/fusion reactors. As this library is more extensive and on a much firmer nuclear physics footing than the previous ENDL99 it should become, after a period of trial use by the applied community, the new standard for programmatic applications at Livermore. This work was supported by ASC-PEM and Campaign 4. Our basic philosophy in this release was to adopt the best work of the world's different nuclear data efforts. We have drawn heavily from the U.S. ENDF project (led by Brookhaven), the Japanese JENDL project (JAEA), and the European JEFF project (NEA). Because those efforts tend to focus on reactor applications they do not include an account of the charged particles emitted following a reaction. To enable broader applications we have used theory-based calculations to add a complete description of charged particles in all evaluations in the new library. This release also includes results from the last ten years of theory and experimental work here at Livermore. Some of the most important results include the surrogate campaign for unstable uranium isotopes, the LLNL/LANL 239Pu(n,2n) evaluation, the 241Am(n,2n) evaluation validated by the recent Livermore-led experiments, and measurements of 48Ti(n,2n). As well, we have adopted more than a hundred theory-based evaluations for radiochemical diagnostics completed by R. Hoffman and M. Mustafa and that use improved optical models, level densities, and decay scheme evaluations from the theory effort. These were extended to be transport complete (they now include a description of all of the particles emitted in reactions) to enable their use in neutronics simulations. There is an ongoing effort to provide all of these radiochemical evaluations, including isomers, in the next major ENDL release. The new library has undergone extensive unclassified testing. All isotopes were required to pass a set of simple tests with both deterministic and Monte Carlo codes to ensure that, at a minimum, they do not cause problems for the transport codes. As well, the data was validated through simulations of historical integral experiments. Calculations for k eigenvalues for a broad array of bare and reflected critical assemblies show a marked improvement over ENDL99 and performance comparable to or better than any other currently available library. In particular, there is now excellent agreement with results for the bare plutonium Jezebel assembly (k=1.0007). Similarly, simulations of photon production and neutron time of flight show, with some exceptions, excellent agreement with the LLNL pulsed sphere experiments. Our intention with this initial release is to engage the programmatic community to begin the process of testing with more complicated unclassified and classified problems. We would greatly appreciate recommendations and any reports of problems or oddities. These will be included in the final release of this database in 2009.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A PIPS + SrI 2 (Eu) detector for atmospheric radioxenon monitoring

The PIPS–SrI 2 (Eu) is a prototype atmospheric radioxenon detection system designed at Oregon State University in support of international efforts towards monitoring clandestine nuclear weapon testing activities. This detector aims to address some shortcomings found in currently deployed beta–gamma atmospheric radioxenon detection systems, such as lackluster energy resolution and memory effect, by employing modern detection materials and readout. The system uses a PIPSBox, a silicon-based gas cell, for electron detection, and a pair of ultrabright, D-shaped SrI 2 (Eu) scintillators coupled to silicon photomultipliers for photon detection. A custom eight-channel digital pulse processor equipped with a field programmable gate-array (FPGA) identifies electron–photon coincidences between the volumes in near real-time. Gas samples of the four radioxenon isotopes of interest were independently measured with the PIPS–SrI 2 (Eu) detection system to determine energy resolution and efficiency. Application of FPGA-based coincidence discrimination in near real-time reduced the ambient background count rate by 95.85 ± 0.04%. Using parameters from the Xenon International gas processing unit and assuming a blank sample and zero memory effect the minimum detectable concentrations (MDCs) for the isotopes were calculated to be 0.12 ± 0.03, 0.27 ± 0.05, 0.15 ± 0.02, and 1.00 ± 0.08 mBq/m 3 air for 131m Xe, 133 Xe, 133m Xe, and 135 Xe, respectively. These MDC estimates compare well with other radioxenon detection systems employed in the International Monitoring System (IMS) and indicate that the PIPS–SrI 2 (Eu) is in compliance with the Comprehensive Nuclear Test-Ban-Treaty Organization (CTBTO) sensitivity requirement of ≤ 1 mBq/m 3 for 133 Xe.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Purification Techniques for Actinide Radiolysis Studies

Our fundamental understanding of actinide radiation-induced redox chemistry is crucial due to their unavoidable exposure to ionizing radiation fields, both inherent and from in-process applications. Plutonium (Pu) and americium (Am) both possess multiple oxidation states, the careful manipulation of which are essential in the study and utilization of their rich chemistry, developing new technologies, and securing the long-term sustainability of nuclear power. However, knowledge in this area is far from complete. We have studied the radiation-induced chemistry of both Pu and Am through a variety of techniques, including gamma irradiation, in-situ alpha irradiation and pulse radiolysis experiments. However, for the collection of accurate data, thorough purification and quantification of actinide-containing solutions is required. This presentation will cover the purification and quantification techniques employed for the radiolysis experiments described in our recent publications: Kynman et al., Multiscale Modeling of Plutonium Radiation Chemistry in Nitric Acid Solutions. 1. Cobalt-60 Gamma Irradiation of Pu(IV) [https://pubs.acs.org/doi/10.1021/acs.inorgchem.4c00138] and Kynman et al., Generation and Study of Am(IV) by Temperature-Controlled Electron Pulse Radiolysis [https://doi.org/10.1039/D4DT00991F].

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Development of nanosecond time-resolved infrared detection at the LEAF pulse radiolysis facility

When coupled with transient absorption spectroscopy, pulse radiolysis, which utilizes high-energy electron pulses from an accelerator, is a powerful tool for investigating the kinetics and thermodynamics of a wide range of radiation-induced redox and electron transfer processes. The majority of these investigations detect transient species in the UV, visible, or near-IR spectral regions. Unfortunately, the often-broad and featureless absorption bands in these regions can make the definitive identification of intermediates difficult. Time-resolved vibrational spectroscopy would offer much improved structural characterization, but has received only limited application in pulse radiolysis. In this paper, we describe in detail the development of a unique nanosecond time-resolved infrared (TRIR) detection capability for condensed-phase pulse radiolysis on a new beam line at the LEAF facility of Brookhaven National Laboratory. The system makes use of a suite of high-power, continuous wave external-cavity quantum cascade lasers as the IR probe source, with coverage from 2330-1051 cm⁻¹. The response time of the TRIR detection setup is ~40 ns, with a typical sensitivity of ~100 µOD after 4-8 signal averages using a dual-beam probe/reference normalization detection scheme. As a result, this new detection method has enabled mechanistic investigations of a range of radiation-induced chemical processes, some of which are highlighted here.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

System of laser pump and synchrotron radiation probe microdiffraction to investigate optical recording process

We have developed a system of laser-pump and synchrotron radiation probe microdiffraction to investigate the phase-change process on a nanosecond time scale of Ge{sub 2}Sb{sub 2}Te{sub 5} film embedded in multi-layer structures, which corresponds to real optical recording media. The measurements were achieved by combining (i) the pump-laser system with a pulse width of 300 ps, (ii) a highly brilliant focused microbeam with wide peak-energy width ({Delta}E/E {approx} 2%) made by focusing helical undulator radiation without monochromatization, and (iii) a precise sample rotation stage to make repetitive measurements. We successfully detected a very weak time-resolved diffraction signal by using this system from 100-nm-thick Ge{sub 2}Sb{sub 2}Te{sub 5} phase-change layers. This enabled us to find the dependence of the crystal-amorphous phase change process of the Ge{sub 2}Sb{sub 2}Te{sub 5} layers on laser power.

36 MATERIALS SCIENCE↗

Ultrasonic measurement of temperature distributions in extreme environments: Electrical power plants testing in utility-scale steam generators

Thermal heterogeneities within energy conversion and storage, material processing, nuclear processes, aerospace, and military applications are often inaccessible to characterization by insertion sensors. When sensor deployment is possible, conventional pointwise temperature probes quickly degrade when inserted into harsh environments typical of such processes. We developed spatially-resolved ultrasonic thermometry to noninvasively measure the spatial distributions of thermal properties in such applications, even when sizable thermal gradients are present. Our method divides the path of ultrasonic propagation into segments bound by echogenic features, which create echoes in pulse-echo mode, encoding the information about interior temperature distributions. We use the acquired ultrasonic responses to estimate the internal temperature distributions by solving an inverse problem or concatenating segmental estimates. This work describes the implementation and industrial testing of the developed method at a coal-fired electrical power generation plant. We inserted an echogenically segmented Inconel 625 waveguide into the combustion zone of the utility-scale boiler and continuously acquired ultrasonic data while keeping sensitive components away from the damaging combustion environment. The accuracy of the time-dependent temperature distributions reconstructed from the ultrasonic measurements was comparable to that of thermocouples. The resiliency of ultrasonic thermometry to harsh combustion conditions was far superior to conventional insertion sensors. The measurements obtained during plant operation captured daily steam generation cycles in response to changing customer demand and intermittent contributions of renewable power sources to the power grid. These measurements have revealed new insights into the relationship between the dynamic power generation load and the conditions inside the steam generator. As a result, the successful industrial testing of spatially-resolved ultrasonic thermometry in solids indicates that the developed technology has matured to become an attractive alternative to conventional sensing in solving challenging problems of long-term thermal characterizations in extreme environments.

42 ENGINEERING↗

Radiation, optical, power flow, and electrical diagnostics at the Z facility: Layout and techniques utilized to operate in the harsh environment

The Z machine is a current driver producing up to 30 MA in 100 ns that utilizes a wide range of diagnostics to assess accelerator performance and target behavior conduct experiments that use the Z target as a source of radiation or high pressures. Here, we review the existing suite of diagnostic systems, including their locations and primary configurations. The diagnostics are grouped in the following categories: pulsed power diagnostics, x-ray power and energy, x-ray spectroscopy, x-ray imaging (including backlighting, power flow, and velocimetry), and nuclear detectors (including neutron activation). We will also briefly summarize the primary imaging detectors we use at Z: image plates, x-ray and visible film, microchannel plates, and the ultrafast x-ray imager. The Z shot produces a harsh environment that interferes with diagnostic operation and data retrieval. We term these detrimental processes “threats” of which only partial quantifications and precise sources are known. Finally, we summarize the threats and describe techniques utilized in many of the systems to reduce noise and backgrounds.

47 OTHER INSTRUMENTATION↗

Development of a systematic approach for safety assessment of PLD based equipment of I and C systems - 354

Nuclear power plants (NPPs) increasingly apply digital equipment for instrumentation and control (I and C) systems. During the life cycle of NPPs the operators, designers and manufactures are facing the need to replace or upgrade obsolete equipment or to implement new digital I and C systems. A relatively new challenge in this area is the deployment of programmable logic devices (PLDs) for the equipment of I and C systems. Regulatory approval for safety and safety related I and C systems demands confirmation of evidence that design as well as verification and validation (V and V) processes have ensured that the application of new equipment will fulfil safety and reliability requirements and its intended design function. The objective of the recent research project of GRS is developing a systematic approach for the assessment of PLD-based equipment in safety and safety-related I and C systems regarding the fulfilment of regulatory requirements and identification of undesired failure effects. A generic approach for the safety-oriented assessment of PLD-based equipment has been developed, based on the principles of a Plan-Do-Check-Act (PDCA) cycle. The approach comprises planning of the assessment, predefined analysis steps and methodologies, as well as required input information, criteria for decision making process, the tasks concerning identification of improvement potential and determining documentation. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development and Optimization of Voltammetric Methods for Real Time Analysis of Electrorefiner Salt with High Concentrations of Actinides and Fission Products

This project addresses the problem of achieving accurate material control and accountability (MC&A) around pyroprocessing electrorefiner systems. Spent nuclear fuel pyroprocessing poses a unique challenge with respect to reprocessing technology in that the fuel is never fully dissolved in the process fluid. In this case, the process fluid is molten, anhydrous LiCl-KCl salt. Therefore, there is no traditional input accountability tank. However, electrorefiners (ER) accumulate very large quantities of fissile nuclear material (including plutonium) and should be well safeguarded in a commercial facility. Idaho National Laboratory (INL) currently operates a pyroprocessing facility for treatment of spent fuel from Experimental Breeder Reactor-II with two such ER systems. INL implements MC&A via a mass tracking model in combination with periodic sampling of the salt and other materials followed by destructive analysis. This approach is projected to be insufficient to meet international safeguards timeliness requirements. A real time or near real time monitoring method is, thus, direly needed to support commercialization of pyroprocessing. A variety of approaches to achieving real time monitoring for ER salt have been proposed and studied to date—including a potentiometric actinide sensor for concentration measurements, a double bubbler for salt depth and density measurements, and laser induced breakdown spectroscopy (LIBS) for concentration measurements. While each of these methods shows some promise, each also involves substantial technical complexity that may ultimately limit their implementation. Yet another alternative is voltammetry —a very simple method in theory that has previously been tested for this application to a limited extent. The equipment for a voltammetry system consists of off-the-shelf components (three electrodes and a potentiostat), which results in substantial benefits relative to cost and robustness. Based on prior knowledge of electrochemical reduction potentials for each of the species of interest, voltammetry can be used to quantify concentrations of a variety of elemental species—including uranium, plutonium, minor actinides, and rare earths. Various methods have been tested by other researchers to date—including cyclic voltammetry, square wave voltammetry, normal pulse voltammetry, etc. In most cases, it has been observed that there is a very limited concentration range for which the output can be readily correlated with concentration in the salt. Furthermore, testing to date has been limited to simple ternary salts with only a single element being quantified. While incomplete for application to MC&A for pyroprocessing, these results lead us to believe that voltammetry can be optimized based on salt properties and fundamental electrochemical rate processes to yield a highly accurate and robust method. This project is divided into four tasks jointly executed by three university research groups. This includes experimental measurement of key physical data on the systems of interest, development of a predictive voltammetry model, experimental validation of the voltammetry model, and design/verification of an optimized measurement method. This project supports the goals of the US-ROK Joint Fuel Cycle Study in addition to the NA-24 Office of the National Nuclear Security Agency and the International Atomic Energy Agency (IAEA).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Modifying molecule-surface scattering by ultrashort laser pulses

In recent years it has become possible to align molecules in free space using ultrashort laser pulses. Here we explore two schemes for controlling molecule-surface scattering processes and which are based on laser-induced molecular alignment. In the first scheme, a single ultrashort nonresonant laser pulse is applied to a molecular beam hitting the surface. This pulse modifies the angular distribution of the incident molecules and causes the scattered molecules to rotate with a preferred sense of rotation (clockwise or counterclockwise). In the second scheme, two properly delayed laser pulses are applied to a molecular beam composed of two chemically close molecular species (isotopes, or nuclear-spin isomers). As the result of the double-pulse excitation, these species are selectively scattered to different angles after the collision with the surface. These effects may provide new means for the analysis and separation of molecular mixtures.

74 ATOMIC AND MOLECULAR PHYSICS↗

Search for lepton-flavor-violating rare muon processes

A new approach to seeking three lepton-flavor-violating rare muon processes ({mu} {sup {yields}}e conversion, {mu} {sup {yields}}e + {gamma}, and {mu} {sup {yields}}3e) on the basis of a single experimental facility is proposed. This approach makes it possible to improve the sensitivity level of relevant experiments by factors of 10{sup 5}, 600, and 300 for, respectively, the first, the second, and the third of the above processes in relation to the existing experimental level. The approach is based on employing a pulsed proton beam and on combining a muon source and the detector part of the facility into a unified magnetic system featuring a nonuniform field. A new detector design involving separate units andmaking it possible to study all three muonic processes at a single facility that admits a simple rearrangement of the detectors used is discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Soldering mask laser removal from printed circuit boards aiming copper recycling

Highlights: • Use of laser as a tool for recycling of electronic waste is proposed. • Laser stripping removes varnishes from circuit boards exposing the copper underneath allowing electrochemical copper recover. •Good removal is achieved with nanosecond pulsed irradiation at 1064 nm. • Waste generated by the process is mainly solid, macroscopic and easy to handle. - Abstract: Management of waste of electric and electronic equipment (WEEE) is a key issue for modern societies; furthermore, it contains valuable materials that can be recycled, especially in printed circuit boards (PCB), which have approximately one-third of their weight in copper. In this study we demonstrated the use of laser to strip the covering soldering mask on PCB’s, thus exposing the copper underneath so that extraction techniques may take place. Using a Q-Switched Nd:YAG laser operating at 1064 nm and 532 nm we tested the procedure under different energy conditions. The laser stripping of the soldering mask was achieved with satisfactory results by irradiation with 225 mJ at 1064 nm. However, when using similar parameters at 532 nm the process of the coating ejection was not promoted properly, leading to a faulty detachment. Infrared laser PCB stripping presents itself to be technically viable and environmental friendly, since it uses no chemicals inputs, offering one more option to WEEE treatment and recycling.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗