Search NASA⌕ Search

SEARCH · Search NASA

Results for “parameter sensitivity analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

315 records · Page 18

Modelling the Sensitivity of Yukon River Biogeochemical Dynamics to Environmental and Chemical Drivers: Implications for Dissolved Organic Carbon

Riverine dissolved organic carbon (DOC) is a critical biogeochemical component that transmits information from Arctic soils to the Arctic Ocean, significantly influencing carbon dynamics in this unique ecosystem. As DOC travels downstream, it undergoes transformations that alter its composition and fate. The Yukon River serves as an effective testbed for modelling these dynamics, offering sufficient scale to capture key biogeochemical processes while having a simpler hydrology than other major Arctic rivers, as well as long-term DOC observational data for model validation. To investigate DOC transformations during transit in the Yukon River, we adapted our Arctic Riverine Organic Macromolecular Model by applying regional-specific parameterisations. Our model simulates the transport and transformation of 15 organic macromolecules, including CDOM (coloured dissolved organic matter), proteins, polysaccharides, lipids, lignin phenols, and humic substances. Initial DOC concentrations were derived from observed soil organic carbon stocks in the surrounding watershed, while chemical transformations and hydrological dynamics were modelled along the river's course. Sensitivity and uncertainty analyses were conducted using a Monte Carlo approach under two experimental setups. Results revealed that variability in DOC and CDOM concentrations at the river mouth were predominantly driven by initial DOC concentration (~70% of variability explained) and dilution at confluence points (~10%). The refractory fraction of DOC explained 21%–88% of the variability in 14 macromolecular concentrations and ranked in the top five sensitive parameters for all outputs when a uniform parameter distribution was assumed. However, when a more likely variability was applied to this parameter, its influence on DOC and CDOM decreased. Given that refractory DOC accounts for ~80% of total DOC in Arctic Rivers, this suggests that most DOC resists degradation and retains its chemical composition during transport to the coastal environment. River velocity, which determines residence time, explained 8%–47% of the variability in protein, polysaccharide, lipid, pigments, and lignin phenols at the river mouth. In contrast, chemical turnover times contributed only 1%–5% to output variability. Our findings underscore the need for improved land-specific headwater observations, including seasonal soil moisture and lateral transport dynamics that control the initial tributary-specific DOC inputs. With accelerated permafrost thaw and increasing river discharge, extending our model to other Arctic River systems and seasons will enhance understanding of Arctic riverine carbon fluxes and their contributions to the Arctic Ocean.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cosmology from Planck CMB lensing and DESI DR1 quasar tomography

We present a measurement of the amplitude of matter fluctuations over the redshift range 0.8 ≤ z ≤ 3.5 from the cross correlation of over 1.2 million spectroscopic quasars selected by the Dark Energy Spectroscopic Instrument (DESI) across 7,200 deg 2 (∼ 170 quasars/deg 2 ) and Planck PR4 (NPIPE) cosmic microwave background (CMB) lensing maps. We perform a tomographic measurement in three bins centered at effective redshiftsz=1.44, 2.27 and 2.75, which have ample overlap with the CMB lensing kernel. From a joint fit using the angular clustering of all three redshift bins (auto and cross-spectra), and including an Q m prior from DESI DR1 baryon acoustic oscillations to break the $Ω_{m}-σ_{8}$ degeneracy, we constrain the amplitude of matter fluctuations in the matter-dominated regime to be $σ_{8}=0.929^{+0.059}_{-0.074}$ and $S_{8}≡σ_{8}(Ω_m/0.3)^{0.5} = 0.922^{+0.059}_{-0.073}$. We provide a growth of structure measurement with the largest spectroscopic quasar sample to date at high redshift, which is ∼ 1.5σ higher than predictions from ΛCDM fits to measurements of the primary CMB from Planck PR4. The cross-correlation between PR4 lensing maps and DESI DR1 quasars is detected with a signal-to-noise ratio of 21.7 and the quasar auto-correlation at 27.2 for the joint analysis of all redshift bins. We combine our measurement with the CMB lensing auto-spectrum from the ground-based Atacama Cosmology Telescope (ACT DR6) and Planck PR4 to perform a sound-horizon-free measurement of the Hubble constant, yielding $H_{0}=69.1^{+2.2}_{-2.6} {\rm \ km\ s}^{-1}{\rm Mpc}^{-1}$ through its sensitivity to the matter-radiation equality scale.

baryon acoustic oscillations↗

Systems Analysis of Biomass and Coal Co-firing Power Plants with Deep Carbon Capture Toward Net-zero Emissions

Achieving a net-zero emission economy in the United States requires integrating diverse low-carbon and negative-emission technologies into the existing fossil fuel-dominant power fleet. Potential technologies from the low-carbon portfolio include renewable power, fossil power with carbon capture and storage (CCS), bioenergy with CCS (BECCS), and direct air capture (DAC). Renewable power is a clean energy source but has to pair with costly battery storage to provide dispatchable electricity. Fossil power with CCS offers dispatchable electricity yet still relies on DAC to offset residual emissions, even when deploying deep CCS with more than 90% CO2 capture. Coal-biomass co-firing with CCS, a subset of BECCS, is a reliable energy production technology that can be retrofitted from existing electricity generation units (EGUs). Power plant retrofit maximizes the use of the current U.S. coal power fleet without the need for large-scale deployment of new renewable power, battery storage, or DAC. Retrofitting coal-biomass co-firing with deep CCS in EGUs is a promising option, but not a universal solution. Biomass co-firing at a power plant introduces economic challenges and indirectly poses pressure on land and water resources. Meanwhile, retrofitting deep CCS affects plant efficiency and raises electricity generation costs. Overall, the technical feasibility and economic viability of plant retrofits vary across EGUs, as they are contingent upon the regional availability of biomass, unit-specific characteristics, site-specific fuel supply costs, and adjacent CO2 storage potential. Government incentives like 45Q can improve the retrofit viability, though the impact requires further quantification. A comprehensive analysis at the unit level is essential to address the question regarding the fate of the U.S. coal-fired electricity generation fleet toward the net-zero emission goal. This study conducts a systematic techno-economic-environmental assessment of EGUs to identify the viability of biomass co-firing and deep CCS retrofits in the U.S. coal-fired power fleet. Specifically, it characterizes the techno-economic performance of deep carbon capture, estimates life cycle greenhouse gas (GHG) emissions, and conducts a fleet-level assessment on retrofit viability. The key objectives are (1) to estimate the unit-specific performance and retrofitted cost under various biomass co-firing levels and CO2 capture rates; (2) to determine the possibility of reaching net-zero emission at the fleet level; (3) to quantify the cumulative capacities that are suitable for plant retrofits under current and future biomass supply scenarios; and (4) to improve the understanding of policy impacts on such retrofits to help the power sector’s transition to a net-zero economy. Techno-economic Model of Deep Carbon Capture. This study develops the performance and economic models for Monoethanolamine-based post-combustion CO2 capture at 95–99% capture rates. The process is simulated in Aspen Plus, analyzing the performance of carbon capture technology by varying the plant sizes, solvent lean loading, CO2 concentrations, and flue gas inlet temperature. Based on the key inputs and output parameters of CO2 capture, a reduced-order performance model of deep carbon capture is formulated. In addition, an engineering-economic model integrating the performance metrics is developed to estimate the capital as well as operation and maintenance (O&M) costs. Capital cost estimations follow the framework of the Integrated Environmental Control Model (IECM) and incorporate data regressions from three technical reports by IECM, the National Energy Technology Laboratory (NETL), and the National Renewable Energy Laboratory. The O&M cost estimation utilizes the actual inventory consumption rate and labor requirements. Both performance and cost models are embedded into IECM v13.0-beta, a fossil-fuel power plant modeling tool. Life Cycle Assessment of Power Plants. This study estimates the GHG emissions of power plants through life cycle assessment (LCA). The LCA scope includes fuel supply, combustion-based power generation, and CO2 transport and storage. The fuel-based life cycle module is designed following the framework of the NETL Unit Process Library and CO2U LCA Guidance Toolkit. The module is then incorporated into IECM v13.0-beta. The process-based LCA is applied to estimate the GHG emissions of coal and biomass supply, coal- and coal-biomass co-firing power plant operation, as well as CO2 pipeline transport and geographical sequestration. An uncertainty analysis is conducted to quantify the variability and uncertainty associated with the LCA using the Latin Hypercube Sampling (LHS) method. Fleet-level Assessment. This study evaluates the technical and economic feasibility of selected coal-fired EGUs, examines the role of tax credits in retrofit viability, and assesses the competitiveness of retrofitted units against other low-carbon options. Unit screening identifies EGUs for the study, focusing on new, efficient baseload units with air pollution controls. The power plant databases are then established to organize unit-specific information on performance and operating conditions from the relevant public databases. Biomass for co-firing retrofits is selected based on home and neighboring county availability, ensuring sustained operation with at least a 5% co-firing level. The CO2 storage site is determined by state-level storage potential, with ArcGIS Pro and NETL CO2 Saline Storage Cost Model used to identify the optimal balance between the nearest transport distances and affordable storage costs. The latest IECM v13.0-beta is then employed to configure and evaluate the eligible EGUs with or without the deployment of deep CCS and biomass co-firing. A supply curve is established to illustrate the cumulative installed capacity suitable for retrofits at different cost levels. A sensitivity analysis on tax credits for carbon sequestration is performed. Finally, a unit-level cost comparison is conducted among retrofitted plants, renewable power with battery storage, and abated fossil fuels with DAC. Expected Results. This study evaluates the technical, economic, and environmental metrics of each EGU across an array of CO2 capture rates and biomass co-firing level scenarios. Unit-level comparisons will identify critical factors influencing technical performance. The supply curves with and without tax incentives will provide insights into the impact of tax credits on biomass co-firing and CCS deployment. The cost comparisons with renewables and DAC-retrofit will assess the competitiveness of the retrofitted units. Life cycle emissions from each unit will be assessed to identify the scenarios under which net-zero emissions can be achieved. These analyses are expected to determine the total coal-fired capacity suitable for serving as a low-carbon energy source with or without tax incentives. The study results are novel in identifying optimal unit-specific strategies for producing carbon-neutral power, whether through retrofitting EGUs with deep CCS, biomass co-firing, DAC, or installing renewable power with battery. The findings will provide insight into nationwide efforts to ensure reliable, affordable, and low-carbon electricity. It also will inform investment decisions and policies in the deployment of deep carbon capture and negative emission technologies for a net-zero energy future.

Biomass Co-firing↗

Validating the galaxy and quasar catalog-level blinding scheme for the DESI 2024 analysis

In the era of precision cosmology, ensuring the integrity of data analysis through blinding techniques is paramount — a challenge particularly relevant for the Dark Energy Spectroscopic Instrument (DESI). DESI represents a monumental effort to map the cosmic web, with the goal to measure the redshifts of tens of millions of galaxies and quasars. Given the data volume and the impact of the findings, the potential for confirmation bias poses a significant challenge. To address this, we implement and validate a comprehensive blind analysis strategy for DESI Data Release 1 (DR1), tailored to the specific observables DESI is most sensitive to: Baryonic Acoustic Oscillations (BAO), Redshift-Space Distortion (RSD) and primordial non-Gaussianities (PNG). We carry out the blinding at the catalog level, implementing shifts in the redshifts of the observed galaxies to blind for BAO and RSD signals and weights to blind for PNG through a scale-dependent bias. We validate the blinding technique on mocks as well as on data by applying a second blinding layer to perform a series of sanity checks; the latter allows probing complexities in real data not captured in mocks. We find that the blinding strategy alters the data vector in a controlled way, and the BAO and RSD analysis choices are robust to blinding. The successful validation of the blinding strategy paves the way for the unblinded DESI DR1 analysis, alongside future blind analyses with DESI and other surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimal reconstruction of baryon acoustic oscillations for DESI 2024

Baryon acoustic oscillations (BAO) provide a robust standard ruler to measure the expansion history of the Universe through galaxy clustering. Density-field reconstruction is now a widely adopted procedure for increasing the precision and accuracy of the BAO detection. With the goal of finding the optimal reconstruction settings to be used in the DESI 2024 galaxy BAO analysis, we assess the sensitivity of the post-reconstruction BAO constraints to different choices in our analysis configuration, performing tests on blinded data from the first year of DESI observations (DR1), as well as on mocks that mimic the expected clustering and selection properties of the DESI DR1 target samples. Overall, we find that BAO constraints remain robust against multiple aspects in the reconstruction process, including the choice of smoothing scale, treatment of redshift-space distortions, fiber assignment incompleteness, and parameterizations of the BAO model. We also present a series of tests that DESI followed in order to assess the maturity of the end-to-end galaxy BAO pipeline before the unblinding of the large-scale structure catalogs.

79 ASTRONOMY AND ASTROPHYSICS↗

Impact of recent ENDF nuclear data update, high initial enrichment and high burnup fuel on critical experiments applicability determination via the integral index c k for burnup credit validation

In 2012, NUREG/CR-7109 reported on the validation of burnup credit calculations involving major and minor actinides and major fission products which was investigated for pressurized and boiling water reactor (PWR and BWR) fuel enrichments up to 5 wt% 235 U and assembly-average burnups up to 60 GWd/MTU. Recently, there has been interest in increasing the maximum enrichment used in PWR fuel as high as 8 wt% 235 U and correspondingly increasing the maximum assembly-average burnups to approximately 75 GWd/MTU. These proposed increases in enrichment and burnup necessitate reinvestigation of the validation basis for k eff calculations for this expanded application space. Additionally, the 2012 study was performed by using the Evaluated Nuclear Data File (ENDF)/B-VII.0 nuclear data with the SCALE 6 covariance library, and the effects of using the newly released ENDF/B-VII.1 and ENDF/B-VIII.0 nuclear data and covariance libraries should be evaluated. In this work, published in NUREG/CR-7309 in 2025, the validation assessment was performed consistently with NUREG/CR-7109: modeling irradiated fuel assemblies in the Generic Burnup Credit (GBC)-32 cask defined in NUREG/CR-6747. The TSUNAMI-3D sequence was used to generate sensitivity data for the application model, and the data were compared with sensitivity data from select benchmark models. The integral parameter c k is the metric of similarity used in this study and is consistent with NUREG/CR-7109, where a c k value in excess of 0.8 indicates sufficient similarity for use in validation. A new set of benchmark experiments with sensitivity data has been assembled for this effort. The number of experiments with available sensitivity data is now 2,104, compared to 474 in NUREG/CR-7109. This increase was facilitated by the efforts of the Nuclear Energy Agency to generate sensitivity data for a majority of the experiments in the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook to supplement the data available in the Oak Ridge National Laboratory (ORNL) Verified, Archived Library of Inputs and Data (VALID). The complete set of benchmarks considered here includes experiments for low-enriched uranium (LEU), intermediate enriched uranium (IEU), and a mixture of uranium and plutonium (MIX) from the ICSBEP Handbook and VALID, as well as ORNL models of the Haut Taux de Combustion (HTC) experiments and other potentially relevant models not included in VALID. The updated similarity study shows that none of the extended burnup and higher enrichment combinations considered show a significant decrease in the number of potentially applicable experiments, meaning sufficient critical experiments exist for the validation of BUC criticality safety calculations, with initial enrichments up to 8 wt% 235 U and burnups up to 80 GWd/MTU. Additionally, both the ENDF/B-VII.1 and ENDF/B-VIII.0 nuclear data libraries can be used for validation since the number of critical experiments applicable for validation increases for most cases with the most recent nuclear data compared to the previous one. As in previous BUC validation studies, the French HTC experiments are the most similar in a majority of the application cases studied, especially from representative discharge burnups ranging from 40 to 80 GWd/MTU. In conclusion, these results match the conclusions presented in NUREG/CR-7109 regarding validation of the primary actinides in BUC analyses.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Noise limits for dc SQUID readout of high- Q resonators below 300 MHz

We present the limits on noise for the readout of cryogenic high-Q resonators using dc Superconducting Quantum Interference Devices (SQUIDs) below 300 MHz. This analysis uses realized first-stage SQUIDs (previously published), whose performance is well described by Tesche–Clarke (TC) theory, coupled directly to the resonators. We also present data from a prototype second-stage dc SQUID array designed to couple to this first-stage SQUID as a follow-on amplifier with high system bandwidth. This analysis is the first full consideration of dc SQUID noise performance referred to a high-Q resonator over this frequency range and is presented relative to the standard quantum limit. We include imprecision, backaction, and backaction–imprecision noise correlations from TC theory, the noise contributed by the second-stage SQUIDs, wiring, and preamplifiers, and optimizations for both on-resonance measurements and off-resonance scan sensitivity. This architecture has modern relevance due to the increased interest in axion searches and the requirements of the DMRadio-m 3 axion search, which uses dc SQUIDs in this frequency range.

Bosons↗

Cosmological implications of DESI DR2 BAO measurements in light of the latest ACT DR6 CMB data

We report cosmological results from the Dark Energy Spectroscopic Instrument (DESI) measurements of baryon acoustic oscillations (BAO) when combined with recent data from the Atacama Cosmology Telescope (ACT). By jointly analyzing ACT and Planck data and applying conservative cuts to overlapping multipole ranges, we assess how different 𝑃⁢𝑙⁢𝑎⁢𝑛⁢𝑐⁢𝑘 + ACT dataset combinations affect consistency with DESI. While ACT alone exhibits a tension with DESI exceeding 3⁢𝜎 within the Λ⁢ CDM model, this discrepancy is reduced when ACT is analyzed in combination with Planck. For our baseline DESI DR2 BAO + 𝑃⁢𝑙⁢𝑎⁢𝑛⁢𝑐⁢𝑘 P⁢R⁢4 + ACT likelihood combination, the preference for evolving dark energy over a cosmological constant is about 3⁢𝜎, increasing to over 4⁢𝜎 with the inclusion of type Ia supernova data. While the dark energy results remain quite consistent across various combinations of Planck and ACT likelihoods with those obtained by the DESI collaboration, the constraints on neutrino mass are more sensitive, ranging from ∑𝑚 𝜈 < 0.061 eV in our baseline analysis, to ∑𝑚 𝜈 < 0.077 eV (95% confidence level) in the CMB likelihood combination chosen by ACT when imposing the physical prior ∑𝑚 𝜈 > 0 eV.

79 ASTRONOMY AND ASTROPHYSICS↗