New position-sensitive hard X-ray spectrometer

The design and features of a new prototype Lixiscope (Low intensity X-ray imaging scope) is described. It is shown that in addition to good spatial and temporal resolution in the 20 keV to 200 keV region, it is capable of single-photon counting, imaging as well as good energy resolution. It is concluded that the device is well suited for future low-flux applications in astronomy, medicine, and industry.

Yin, L. I.↗

Improved Lixiscope

Improved lixiscope utilizes fast-decay scintillators and multiple or curved microchannels to achieve high energy and spatial resolution as well as single-photon counting. New unit, with higher energy resolution, is intended for X-ray astronomy, although it could be applied terrestrially wherever a sensitive portable radiation spectrometer is required for 20-to-200-keV range.

Yin, L. I.↗

Laser radar

A laser radar system to measure the altitude distribution of atmospheric sodium in the 80 to 100 km altitude region was constructed. The system consists of a high power pulsed dye laser, large aperture receiving telescope, and photon counting and signal processing equipment. The receiving system development, and the construction and development of the dye laser are discussed. Spatial and temporal filtering of the data to enhance the resolution of the sodium lidar profiles is described as well as computer model studies of the sodium density response to gravity wave perturbations.

Source record↗

A lower limit on the magnitude of the companion to HDE 226868 /Cygnus X-1/

High-precision digital spectra of the HDE 226868/Cygnus X-1 system have been obtained at a variety of orbital phases, using a Digicon photon counting array at the coude focus of the Lick Shane reflector. The spectra have been cross-correlated to search for evidence for the existence of a luminous stellar companion to HDE 226868, as has been suggested by several models where the secondary star is not a black hole. We find no evidence for such a star and place a lower limit on the difference between HDE 226868 and its companion of 4 magnitudes. This limit rules out all of the models for the Cygnus X-1 system calculated by Avni and Bahcall which include main-sequence stars as secondaries rather than black holes. A merit function generally useful for cross-correlation of digital spectra is described.

Shafter, A. W.↗

A dual charge-coupled device /CCD/, astronomical spectrometer and direct imaging camera. I - Optical and detector systems

The MASCOT (MIT Astronomical Spectrometer/Camera for Optical Telescopes), an instrument capable of simultaneously performing both direct imaging and spectrometry of faint objects, is examined. An optical layout is given of the instrument which uses two CCD's mounted on the same temperature regulated detector block. Two sources of noise on the signal are discussed: (1) the CCD readout noise, which results in a constant uncertainty in the number of electrons collected from each pixel; and (2) the photon counting noise. The sensitivity of the device is limited by the sky brightness, the overall quantum efficiency, the resolution, and the readout noise of the CCD. Therefore, total system efficiency is calculated at about 15%.

Meyer, S. S.↗

The Johns Hopkins Ultraviolet Telescope for Shuttle astronomy

The Hopkins Ultraviolet Telescope (HUT) is a 90-cm f/2 prime focus telescope and spectrometer with a photon-counting microchannel plate detector designed to obtain moderate resolution (wavelength interval, approximately 4 A) spectrophotometry of faint (visual magnitude, less than approximately 17) objects in the far-ultraviolet spectral region (approximately 900-1700 A). The HUT will be mounted on the Spacelab Instrument Pointing System and will be operated by a Payload Specialist using a field acquisition TV system to assist in locating targets. The initial flight of the HUT, expected in 1984 or 1985, will be devoted primarily to the study of quasars and active galactic nuclei, emphasizing the 900-1200 A spectral region which is inaccessible with other existing or currently planned orbiting instruments.

Davidson, A. F.↗

A spectroscopic study of the high excitation nebula NGC 6302

The wonderfully intricate irregular gaseous nebula NGC 6302 shows a great range of excitation from the S I to Fe VII forbidden lines. Data obtained with the International Ultraviolet Explorer (IUE) covering the spectral range of wavelengths 1200-3203 and with the image-photon counting system at the Anglo-Australian telescope emphasizing the region of wavelengths 3200-4880 are used for a new determination of the chemical composition of this object. No simple theoretical model can represent the observed intensities. Helium and nitrogen are enhanced in abundance, as noted by previous observers, but the enrichment of nitrogen is a whole order of magnitude. Carbon and oxygen are decreased in abundance, neon and heavier elements show a 'normal' abundance pattern, but calcium and possibly silicon are depleted; presumably they are concentrated in grains.

Aller, L. H.↗

MAGELLAN: High resolution spectroscopy at FUV and EUV wavelengths

The aim of ESA's MAGELLAN mission is to provide high resolution spectra of celestial sources down to sixteenth magnitude over the extreme ultraviolet wavelength range (between 50 and 140 nm). This range extends from studies of interstellar matter in the disc and halo of this and other galaxies, to stellar envelopes, hot and evolved stars, clusters, intergalactic matter, nuclei of galaxies, quasars, and, finally, planets and satellites. The instrument has a nonconventional optical design using only one reflecting surface; a high groove density concave grating collects the star light, diffracts it and focuses its spectrum into a bidimensional windowless detector operated in a photon counting mode. The slitless configuration provides the spectra of all the sources (point like and extended) in the field of view of the grating. This field of view is limited by a grid collimator to reduce the diffuse background, the stray light and the probability of overlapping spectra in crowded fields.

Grewing, M.↗

Performance of a near-optimum receiver for optical antipodal signals

The well known photon-counting, heterodyning and homodyning optical receivers (operating over a free-space channel) do not achieve the performance of the optimum quantum receiver, which attains significantly lower error-probabilities than the above receiver structures. A demonstration and analysis are given of a binary antipodal optical receiver that exponentially approaches the performance of the optimum quantum receiver. A general mathematical model is developed, and subsequently used to evaluate the effects of external interference and internal error-sources on receiver performance.

Vilnrotter, V. A.↗

Rocket-borne instrument with a high-resolution microchannel plate detector for planetary UV spectroscopy

A telescope-spectrograph employing a photon-counting microchannel plate (MCP)-CODACON detector has been built, tested, and flown on a sounding rocket. The detector uses a curved-channel MCP proximity focused onto a coded anode array of 1024 channels spaced 25.4-mm center to center. High quantum efficiency is obtained by depositing a cesium iodide photocathode on the front surface of the MCP. The instrument has obtained an ultraviolet spectrum of Jupiter with a spectral resolution of 8 A, which is higher than that of any previously reported observation in this wavelength range.

Mcclintock, W. E.↗

Recent progress with multi-anode microchannel array detector systems

The construction and modes of operation of Multi-Anode Microchannel Arrays (MAMA's) are briefly reviewed. The MAMA detectors, which are a family of photoelectric, photon-counting array detectors being developed specifically for use in instruments on ground-based and space-borne telescopes, combine the high sensitivity and photometric stability of a conventional channel electron multiplier with a high-resolution imaging capability. The MAMA detectors feature low applied potential (less than 3 kV), high gain (greater than 10 to the 6th electrons/pulse), an absolute event timing accuracy of 100 ns or better, a very long count lifetime (greater than 2.5 x 10 to the 11th counts/sq mm), and a power consumption of less than 30 W for a complete system

Timothy, J. G.↗

Efficient Coding for Optical Communication

Possibility of using photon counting, rather than conventional linear amplification, for optical communications discussed. Study suggests combination of pulse-position modulation and Reed-Solomon coding gives signaling efficiency of 3 to 4 bits/photon.

Mceliece, R. J.↗

Current NASA studies for a Far Ultraviolent Spectrographic Explorer (FUSE)

The NASA plans for FUSE, a satellite which obtains spectra with resolutions between 100,000 and 100 in the spectral regions from 912 to 1216A and 100 to 912A, are outlined. Scientific problems which can be tackled by FUSE, but not by IUE or the Space Telescope, are discussed. A grazing incidence echelle and a hybrid echelle design are presented. They have high throughput, large simultaneous spectral range, and low background photon counting statistics. The satellite operational organization is similar to that of IUE.

Linsky, J.↗

Feasibility study of an optically coherent telescope array in space

Numerical methods of image construction which can be used to produce very high angular resolution images at optical wavelengths of astronomical objects from an orbiting array of telescopes are discussed and a concept is presented for a phase-coherent optical telescope array which may be deployed by space shuttle in the 1990's. The system would start as a four-element linear array with a 12 m baseline. The initial module is a minimum redundant array with a photon-counting collecting area three times larger than space telescope and a one dimensional resolution of better than 0.01 arc seconds in the visible range. Later additions to the array would build up facility capability. The advantages of a VLBI observatory in space are considered as well as apertures for the telescopes.

Traub, W. A.↗

A study of the temporal and spectral characteristics of gamma ray bursts

Gamma-ray burst data obtained from the ISEE-3 Gamma Ray Burst Spectrometer and the Solar Maximum Mission's Hard X-ray Burst Spectrometer (HXRBS) were analyzed to yield information on burst temporal and spectral characteristics. A Monte Carlo approach was used to simulate the HXRBS response to candidate spectral models. At energies above about 100 keV, the spectra are well fit by exponential forms. At lower energies, 30 keV to 60 keV, depressions below the model continua are apparent in some bursts. The depressions are not instrumental or data-reduction artifacts. The event selection criterion of the ISEE-3 experiment is based on the time to accumulate a present number of photons rather than the photon count per unit time and is consequently independent of event duration for a given burst intensity, unlike most conventional systems. As a result, a significantly greater percentage of fast, narrow events have been detected. The ratio of count rates from two ISEE-3 detectors indicates that bursts with durations or approx. one second have much softer spectra than longer bursts.

Norris, J.↗

Evaluation of a virtual phase charged-coupled device as an imaging X-ray spectrometer

The X-ray response of an 800 x 800 Texas Instruments virtual phase charge-coupled device (CCD) has been measured in the range 1-8 keV. In the single-photon counting mode, excellent energy resolution (approximately 250 eV FWHM is found for single-pixel Fe-55 X-ray events at a spatial resolution of 15 microns. The detector quantum efficiency for all events is 65% at 2.3 keV (S K line) and approximately 34% at 5.9 keV (Mn K line from Fe-55). The CCD response is linear in energy to a few percent over the 1-8 keV energy range. These results demonstrate that virtual phase CCDs are superior imaging X-ray spectrometers with applications for X-ray astronomy and laboratory plasma research.

Stern, R. A.↗

Speckle imaging for planetary research

The present study of speckle imaging technique effectiveness encompasses image reconstruction by means of a division algorithm for Fourier amplitudes, and the Knox-Thompson (1974) algorithm for Fourier phases. Results which have been obtained for Io, Titan, Pallas, Jupiter and Uranus indicate that spatial resolutions lower than the seeing limit by a factor of four are obtainable for objects brighter than Uranus. The resolutions obtained are well above the diffraction limit, due to inadequacies of the video camera employed. A photon-counting camera has been developed to overcome these difficulties, making possible the diffraction-limited resolution of objects as faint as Charon.

Nisenson, P.↗