Search NASA⌕ Search

SEARCH · Search NASA

Results for “plane of array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

The Simons Observatory Microwave SQUID Multiplexing Detector Module Design

Advances in cosmic microwave background (CMB) science depend on increasing the number of sensitive detectors observing the sky. New instruments deploy large arrays of superconducting transition-edge sensor (TES) bolometers tiled densely into ever larger focal planes. High multiplexing factors reduce the thermal loading on the cryogenic receivers and simplify their design. We present the design of focal-plane modules with an order of magnitude higher multiplexing factor than has previously been achieved with TES bolometers. We focus on the novel cold readout component, which employs microwave SQUID multiplexing (μmux). Simons Observatory will use 49 modules containing 70,000 bolometers to make exquisitely sensitive measurements of the CMB. We validate the focal-plane module design, presenting measurements of the readout component with and without a prototype detector array of 1728 polarization-sensitive bolometers coupled to feedhorns. The readout component achieves a 95% yield and a 910 multiplexing factor. The median white noise of each readout channel is 65 . This impacts the projected SO mapping speed by <8%, which is less than is assumed in the sensitivity projections. The results validate the full functionality of the module. We discuss the measured performance in the context of SO science requirements, which are exceeded.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-490: Independent Three-Dimensional (3D) Dose Verification of VMAT/SBRT Using EPID and Cloud Computing

Purpose: Dosimetric verification of VMAT/SBRT is currently performed on one or two planes in a phantom with either film or array detectors. A robust and easy-to-use 3D dosimetric tool has been sought since the advent of conformal radiation therapy. Here we present such a strategy for independent 3D VMAT/SBRT plan verification system by a combined use of EPID and cloud-based Monte Carlo (MC) dose calculation. Methods: The 3D dosimetric verification proceeds in two steps. First, the plan was delivered with a high resolution portable EPID mounted on the gantry, and the EPID-captured gantry-angle-resolved VMAT/SBRT field images were converted into fluence by using the EPID pixel response function derived from MC simulations. The fluence was resampled and used as the input for an in-house developed Amazon cloud-based MC software to reconstruct the 3D dose distribution. The accuracy of the developed 3D dosimetric tool was assessed using a Delta4 phantom with various field sizes (square, circular, rectangular, and irregular MLC fields) and different patient cases. The method was applied to validate VMAT/SBRT plans using WFF and FFF photon beams (Varian TrueBeam STX). Results: It was found that the proposed method yielded results consistent with the Delta4 measurements. For points on the two detector planes, a good agreement within 1.5% were found for all the testing fields. Patient VMAT/SBRT plan studies revealed similar level of accuracy: an average γ-index passing rate of 99.2± 0.6% (3mm/3%), 97.4± 2.4% (2mm/2%), and 72.6± 8.4 % ( 1mm/1%). Conclusion: A valuable 3D dosimetric verification strategy has been developed for VMAT/SBRT plan validation. The technique provides a viable solution for a number of intractable dosimetry problems, such as small fields and plans with high dose gradient.

60 APPLIED LIFE SCIENCES↗

Synchronization of spin torque nano-oscillators through dipolar interactions

In an array of spin-torque nano-oscillators (STNOs) that combine a perpendicular polarized fixed layer with strong in-plane anisotropy in the free layers, magnetic dipolar interactions can effectively phase-lock the array, thus further enhancing the power of the output microwave signals. We perform a qualitative analysis of the synchronization of an array based on the Landau-Lifshitz-Gilbert equation, with a spin-transfer torque that assumes strong in-plane anisotropy. Finally, we present the numerical results for four coupled STNOs to provide further evidence for the proposed theory.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Surface modes at metallic an photonic crystal interfaces

A surface mode is an electromagnetic field distribution bounded at a surface. It decays exponentially with the distance from the surface on both sides of the surface and propagates at the surface. The surface mode exists at a metal-dielectric interface as surface plasmon (1) or at a photonic crystal surface terminated properly (34; 35; 36). Besides its prominent near-filed properties, it can connect structures at its propagation surface and results in far-field effects. Extraordinary transmission (EOT) and beaming are two examples and they are the subjects I am studying in this thesis. EOT means the transmission through holes in an opaque screen can be much larger than the geometrical optics limitation. Based on our everyday experience about shadows, the transmission equals the filling ratio of the holes in geometrical optics. The conventional diffraction theory also proved that the transmission through a subwavelength circular hole in an infinitely thin perfect electric conductor (PEC) film converges to zero when the hole's dimension is much smaller than the wavelength (40). Recently it is discovered that the transmission can be much larger than the the filling ratio of the holes at some special wavelengths (41). This cannot be explained by conventional theories, so it is called extraordinary transmission. It is generally believed that surface plasmons play an important role (43; 44) in the EOT through a periodic subwavelength hole array in a metallic film. The common theories in literatures are based on these arguments. The surface plasmons cannot be excited by incident plane waves directly because of momentum mismatch. The periodicity of the hole arrays will provide addition momentum. When the momentum-matching condition of surface plasmons is satisfied, the surface plasmons will be excited. Then these surface plasmons will collect the energy along the input surface and carry them to the holes. So the transmission can be bigger than the filling ratio. Based on this picture, they deduced naturally that when surface plasmons momentum-matching condition is satisfied, the surface plasmons are excited sufficiently and the transmission reaches its peak. I present a new theory from first principles to explain EOT through one-dimensional periodic subwavelength metallic slits in this thesis. This theory can also be extended to 2D hole arrays. I define the incident wavelengths that satisfy the momentum-matching condition as surface resonant wavelengths. I proved analytically that the transmission is actually zero at the surface resonant wavelengths. The correct logic is: When the momentum-matching condition is satisfied, the surface plasmons excited by each slit interfere constructively with each other, the total surface plasmons will go to infinity. But the law of nature forbids the infinity. The only solution is the surface plasmon excited by one slit is zero and all the energy is reflected. In my theory, the term corresponding to surface plasmons appear explicitly in the equations. So it confirms the importance of surface plasmons without any doubt. The theory divides the transmission process into two steps: energy collection process along the input surface and the propagation process in the slits. In the first process, the surface plasmons collect the energy along the input surface and carry them to the slits. This process happens efficiently at any wavelength other than the surface resonant wavelengths. So EOT can happen at almost any wavelength. After the energy enter the slits, the Fabry-Perot interference between the input and output surface decides how much energy is emitted from the slits. So the EOT wavelengths are decided by the Fabry-Perot resonances. I also use my theory to explain the data in literatures. The transmission spectra through 1D slits or 2D hole arrays in literatures agree with my theory very well. The new theory can explain a lot of experimental results published recently, such as the transmission through randomized hole arrays, the strong influence of the hole shape on the transmission peaks, and so on. Beaming is another far-field effect resulting from surface modes. Normally light coming from a subwavelength waveguide is diffracted to all angles. With the help of surface modes, we can confine the output field in a small angle interval. This phenomenon is called beaming (46). The principle of the beaming has been explained clearly in literatures (47). To achieve good beaming, a photonic crystal waveguide need a surface layer to support surface modes and a grating layer to coupling the evanescent surface modes into propagation modes. A metallic beaming structure is generally a subwavelength waveguide surrounded by periodic structures such as grooves or dielectric gratings (53; 54). The flat metal surface supports the surface mode, so additional surface layer is not necessary. The periodic structures work as the grating layer.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The microstructure of dislocation clusters in industrial directionally solidified multicrystalline silicon

The microstructure of commonly occurring dislocation patterns in industrial directionally solidified multicrystalline silicon has been systematically studied by light microscopy, electron backscatter diffraction, and transmission electron microscopy. The work has been focused on dislocation clusters on wafers near the top of cast blocks. In near {l_brace}111{r_brace} grain surface, dislocation arrays parallel to {l_brace}110{r_brace} plane traces are lying in parallel rows of {l_brace}111{r_brace} planes inclined to the surface, in mainly <112>30 deg. orientation. The dislocation configuration suggests that the microstructure may result from a recovery process. The dislocations formed during crystal growth and cooling have undergone transformations at high temperature in order to achieve low energy configurations for minimization of dislocation and crystal energy.

36 MATERIALS SCIENCE↗

Catalyst-free growth of Bi{sub 2}Te{sub 3} nanostructures by molecular beam epitaxy

We present the catalyst-free growth of binary Bi{sub 2}Te{sub 3} topological insulator nanostructures on c-plane sapphire substrates by molecular beam epitaxy. Dense arrays of single-crystalline nanostructures, growing along the [110] direction, are obtained for substrate temperatures ranging from ∼180 °C to 260 °C. The growth rate and shape of the nanostructures are highly temperature-dependent. The microscopic study of the nanostructures and their relationship to the underlying Bi{sub 2}Te{sub 3} thin film gives an insight into the growth mechanism.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

AN INFRARED THROUGH RADIO STUDY OF THE PROPERTIES AND EVOLUTION OF IRDC CLUMPS

We examine the physical properties and evolutionary stages of a sample of 17 clumps within 8 Infrared Dark Clouds (IRDCs) by combining existing infrared, millimeter, and radio data with new Bolocam Galactic Plane Survey (BGPS) 1.1 mm data, Very Large Array radio continuum data, and Heinrich Hertz Telescope dense gas (HCO{sup +} and N{sub 2}H{sup +}) spectroscopic data. We combine literature studies of star formation tracers and dust temperatures within IRDCs with our search for ultracompact (UC) H II regions to discuss a possible evolutionary sequence for IRDC clumps. In addition, we perform an analysis of mass tracers in IRDCs and find that 8 {mu}m extinction masses and 1.1 mm BGPS masses are complementary mass tracers in IRDCs except for the most active clumps (notably those containing UC H II regions), for which both mass tracers suffer biases. We find that the measured virial masses in IRDC clumps are uniformly higher than the measured dust continuum masses on the scale of {approx}1 pc. We use {sup 13}CO, HCO{sup +}, and N{sub 2}H{sup +} to study the molecular gas properties of IRDCs and do not see any evidence of chemical differentiation between hot and cold clumps on the scale of {approx}1 pc. However, both HCO{sup +} and N{sub 2}H{sup +} are brighter in active clumps, due to an increase in temperature and/or density. We report the identification of four UC H II regions embedded within IRDC clumps and find that UC H II regions are associated with bright ({approx}>1 Jy) 24 {mu}m point sources, and that the brightest UC H II regions are associated with 'diffuse red clumps' (an extended enhancement at 8 {mu}m). The broad stages of the discussed evolutionary sequence (from a quiescent clump to an embedded H II region) are supported by literature dust temperature estimates; however, no sequential nature can be inferred between the individual star formation tracers.

79 ASTRONOMY AND ASTROPHYSICS↗

Thermal Neutron Imaging Using A New Pad-Based Position Sensitive Neutron Detector

Thermal neutrons (with mean energy of 25 meV) have a scattering mean free path of about 20 m in air. Therefore it is feasible to find localized thermal neutron sources up to ~30 m standoff distance using thermal neutron imaging. Coded aperture thermal neutron imaging was developed in our laboratory in the nineties, using He-3 filled wire chambers. Recently a new generation of coded-aperture neutron imagers has been developed. In the new design the ionization chamber has anode and cathode planes, where the anode is composed of an array of individual pads. The charge is collected on each of the individual 5x5 mm2 anode pads, (48x48 in total, corresponding to 24x24 cm2 sensitive area) and read out by application specific integrated circuits (ASICs). The high sensitivity of the ASICs allows unity gain operation mode. The new design has several advantages for field deployable imaging applications, compared to the previous generation of wire-grid based neutron detectors. Among these are the rugged design, lighter weight and use of non-flammable stopping gas. For standoff localization of thermalized neutron sources a low resolution (11x11 pixel) coded aperture mask has been fabricated. Using the new larger area detector and the coarse resolution mask we performed several standoff experiments using moderated californium and plutonium sources at Idaho National Laboratory. In this paper we will report on the development and performance of the new pad-based neutron camera, and present long range coded-aperture images of various thermalized neutron sources.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Three dimensional metafilms with dual channel unit cells

Three-dimensional (3D) metafilms composed of periodic arrays of silicon unit cells containing single and multiple micrometer-scale vertical split ring resonators (SRRs) per unit cell were fabricated. In contrast to planar and stacked planar structures, these 3D metafilms have a thickness t ~λ d /4, allowing for classical thin film effects in the long wavelength limit. The infrared specular far-field scattering response was measured for metafilms containing one and two resonators per unit cell and compared to numerical simulations. Excellent agreement in the frequency region below the onset of diffractive scattering was obtained. For dense arrays of unit cells containing single SRRs, normally incident linearly polarized plane waves which do not excite a resonant response result in thin film interference fringes in the reflected spectra and are virtually indistinguishable from the scattering response of an undecorated array of unit cells. For the resonant linear polarization, the specular reflection for arrays is highly dependent on the SRR orientation on the vertical face for gap-up, gap-down, and gap-right orientations. For dense arrays of unit cells containing two SRRs per unit cell positioned on adjacent faces, the specular reflection spectra are slightly modified due to near-field coupling between the orthogonally oriented SRRs but otherwise exhibit reflection spectra largely representative of the corresponding single-SRR unit cell structures. Lastly, the ability to pack the unit cell with multiple inclusions which can be independently excited by choice of incident polarization suggests the construction of dual-channel films where the scattering response is selected by altering the incident polarization.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ultra-thin g-C{sub 3}N{sub 4} nanosheets wrapped silicon nanowire array for improved chemical stability and enhanced photoresponse

Highlights: • g-C{sub 3}N{sub 4}, as an oxygen free and metal free protective material for Si, was proposed. • g-C{sub 3}N{sub 4} nanosheets wrapped Si nanowire array was synthesized. • SiNW/g-C{sub 3}N{sub 4} exhibited enhancement of photoelectrochemical stability and photocurrent. - Abstract: In order to inhibit the oxidation of Si materials in aqueous solution, Si nanowire array was wrapped by ultra-thin g-C{sub 3}N{sub 4} nanosheets via an electrophoresis process. Scanning electron microscopy and transmission electron microscopy images showed that g-C{sub 3}N{sub 4} nanosheets were evenly distributed on the surface of Si nanowire array. X-ray diffraction patterns indicated that Si nanowire array/g-C{sub 3}N{sub 4} nanosheets were composed of Si (4 0 0 crystal plane) and g-C{sub 3}N{sub 4} (0 0 2 and 1 0 0 crystal planes). The cyclic voltammetry curves revealed that the corrosion of Si nanowire array was restrained under the protection of g-C{sub 3}N{sub 4} nanosheets. Furthermore, the photocurrent density of Si nanowire array/g-C{sub 3}N{sub 4} nanosheets increased by nearly 3 times compared to that of bare Si nanowire array due to the effective charge separation caused by the built-in electric field at the interface. This work will facilitate the applications of Si materials in aqueous solution, such as solar energy harvest and photocatalytic pollution control.

36 MATERIALS SCIENCE↗

Retinal instrument

In one embodiment, the present invention provides a method of removing scar tissue from an eye that includes inserting a device including an array of micro-rods into an eye, wherein at least one glass micro-rod of the array of glass micro-rods includes a sharp feature; contacting a scar tissue with the array of micro-rods; and removing the array of micro-rods and the scar tissue from the eye. In another embodiment, the present invention provides a medical device for engaging a tissue including and an array of glass micro-rods, wherein at least one glass micro-rod of the array of glass micro-rods includes a sharp feature opposite a base of the array of glass micro-rods that is connected to the cannula, wherein the sharp feature of the at least one micro-rod is angled from a plane that is normal to a face of the base of the array of glass micro-rods.

47 OTHER INSTRUMENTATION↗

Observation of Large Arrays of Plasma Filaments in Air Breakdown by 1.5-MW 110-GHz Gyrotron Pulses

We report the observation of two-dimensional plasma filamentary arrays with more than 100 elements generated during breakdown of air at atmospheric pressure by a focused Gaussian beam from a 1.5-MW, 110-GHz gyrotron operating in 3-{mu}s pulses. Each element is a plasma filament elongated in the electric field direction and regularly spaced about one-quarter wavelength apart in the plane perpendicular to the electric field. The development of the array is explained as a result of diffraction of the beam around the filaments, leading to the sequential generation of high intensity spots, at which new filaments are created, about a quarter wavelength upstream from each existing filament. Electromagnetic wave simulations corroborate this explanation and show very good correlation to the observed pattern of filaments.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Controlled Growth of Ordered III-Nitride Core-Shell Nanostructure Arrays for Visible Optoelectronic Devices

In our paper, we demonstrate the growth of ordered arrays of nonpolar {101 ¯ 0} core–shell nanowalls and semipolar {101 ¯ 1} core–shell pyramidal nanostripes on c-plane (0001) sapphire substrates using selective-area epitaxy and metal organic chemical vapor deposition. The nanostructure arrays are controllably patterned into LED mesa regions, demonstrating a technique to impart secondary lithography features into the arrays. Moreover, we study the dependence of the nanostructure cores on the epitaxial growth conditions and show that the geometry and morphology are strongly influenced by growth temperature, V/III ratio, and pulse interruption time. We also demonstrate the growth of InGaN quantum well shells on the nanostructures and characterize the structures by using micro-photoluminescence and cross-section scanning tunneling electron microscopy.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Quantification of Proton Dose Calculation Accuracy in the Lung

Purpose: To quantify the accuracy of a clinical proton treatment planning system (TPS) as well as Monte Carlo (MC)–based dose calculation through measurements and to assess the clinical impact in a cohort of patients with tumors located in the lung. Methods and Materials: A lung phantom and ion chamber array were used to measure the dose to a plane through a tumor embedded in the lung, and to determine the distal fall-off of the proton beam. Results were compared with TPS and MC calculations. Dose distributions in 19 patients (54 fields total) were simulated using MC and compared to the TPS algorithm. Results: MC increased dose calculation accuracy in lung tissue compared with the TPS and reproduced dose measurements in the target to within ±2%. The average difference between measured and predicted dose in a plane through the center of the target was 5.6% for the TPS and 1.6% for MC. MC recalculations in patients showed a mean dose to the clinical target volume on average 3.4% lower than the TPS, exceeding 5% for small fields. For large tumors, MC also predicted consistently higher V5 and V10 to the normal lung, because of a wider lateral penumbra, which was also observed experimentally. Critical structures located distal to the target could show large deviations, although this effect was highly patient specific. Range measurements showed that MC can reduce range uncertainty by a factor of ∼2: the average (maximum) difference to the measured range was 3.9 mm (7.5 mm) for MC and 7 mm (17 mm) for the TPS in lung tissue. Conclusion: Integration of Monte Carlo dose calculation techniques into the clinic would improve treatment quality in proton therapy for lung cancer by avoiding systematic overestimation of target dose and underestimation of dose to normal lung. In addition, the ability to confidently reduce range margins would benefit all patients by potentially lowering toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Magnetic anisotropies of laterally confined structures of epitaxial Fe films on GaAs (001)

We have investigated magnetic properties of laterally confined structures of epitaxial Fe films on GaAs (001). Fe films with different thicknesses were grown by molecular-beam epitaxy and patterned into regular arrays of rectangles with varying aspect ratios. In-plane magnetic anisotropy was observed in all of the patterned Fe films both at 15 and 300 K. We have demonstrated that the coercive fields can be tuned by varying the aspect ratios of the structures. The magnitudes of the corresponding anisotropy constants have been determined and the shape anisotropy constant is found to be enhanced as the aspect ratio is increased.

36 MATERIALS SCIENCE↗

Dislocation baskets in thick In x Ga 1–x N epilayers

Dislocation clusters have been observed in thick In x Ga 1–x N films with 0.07 ≤ x ≤ 0.12. The clusters resemble baskets with a higher indium content at their interior. Threading dislocations at the basket boundaries are of the misfit edge type, and their separation is consistent with misfit strain relaxation due to the difference in indium content between the baskets and the surrounding matrix. The interior of the base of the baskets reflects no observable dislocations connecting the threading dislocations, and often no net displacements like those due to stacking faults. We believe that the origin of these threading dislocation arrays is associated with misfit dislocations at the basal plane that dissociate, forming stacking faults. And when the stacking faults form simultaneously satisfying the crystal symmetry, the sum of their translation vectors add up to a lattice vector, or equivalently to no change in the stacking sequence, which is consistent with our observations.

36 MATERIALS SCIENCE↗

Single-particle and dipole excitations in Co 62

An extensive study of the level structure of 62 Co has been performed following a complex multinucleon transfer reaction, 26 Mg( 48 Ca, 2α3npγ) 62 Co, at beam energies of 275, 290, and 320 MeV. The combination of the Gammasphere array, the fragment mass analyzer, and a focal-plane ionization chamber was used to identify and delineate excited levels in 62 Co. A considerable extension to the 62 Co level scheme is proposed with firm spin-parity values assigned on the basis of angular distribution and correlation analyses. Here, various level sequences built upon states of single-particle character have been observed, and an interpretation of these structures in the framework of the spherical shell model is presented. At moderate spins, two dipole bands have been observed and, based on their phenomenological study, a possible magnetic rotation character is suggested. However, theoretical calculations performed using the particle rotor model support magnetic rotation for only one of these dipole bands.

59 ≤ A ≤ 89↗

A Fisheye Lens as a Photonic Doppler Velocimetry Probe

A new fisheye lens design is used as a miniature probe to measure the velocity distribution of an imploding surface along many lines of sight. Laser light, directed and scattered back along each beam on the surface, is Doppler shifted by the moving surface and collected into the launching fiber. The received light is mixed with reference laser light in each optical fiber in a technique called photonic Doppler velocimetry, providing a continuous time record. An array of single-mode optical fibers sends laser light through the fisheye lens. The lens consists of an index-matching positive element, two positive doublet groups, and two negative singlet elements. The optical design minimizes beam diameters, physical size, and back reflections for excellent signal collection. The fiber array projected through the fisheye lens provides many measurement points of surface coverage over a hemisphere with very little crosstalk. The probe measures surface movement with only a small encroachment into the center of the cavity. The fiber array is coupled to the index-matching element using index-matching gel. The array is bonded and sealed into a blast tube for ease of assembly and focusing. This configuration also allows the fiber array to be flat polished at a common object plane. In areas where increased measurement point density is desired, the fibers can be close packed. To further increase surface density coverage, smaller-diameter cladding optical fibers may be used.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗