At least 325 records · Page 18

Hawaii Solar Desalination Project

This project built the world’s largest Forward Osmosis (FO) solar thermal desalination plant at the NELHA Hawaii Ocean Science and Technology Park for a high visibility “on sun” demonstration of seawater desalination for agricultural applications. The project included re-commissioning an existing 2MW micro-dish solar thermal array and coupling it to a next-generation 500m3/day FO system. The purpose of the project was to validate FO at commercial scale; to verify that the water produced is safe for potential downstream agricultural users; to gather data on capital cost, energy consumption and operating expense for the technology; and to demonstrate that FO can be successfully coupled to low-grade thermal resources. The plant implemented advancements in FO component technology, including hot nano-filtration, polymeric heat exchangers, draw solutions, and improved FO membranes, and operated from June 2022 to September 2023 - producing 30gpm of permeate water. Thermal energy was below 30kWh/m 3 during operation, establishing a new benchmark in thermal desalination technology, with recovery rates at times exceeding 65%, well above what commercial RO systems can achieve. Combining the plant capital cost (CAPEX) and the operating expenses (OPEX) yields a Levelized Cost of Water (LCOW) that is competitive with existing carbon-intensive technologies such as RO. The ability of the plant to operate from a renewable resource paves the way toward a low-carbon desalination future using low-grade thermal resources.

14 SOLAR ENERGY↗

Enabling Grid-Aware Market Participation of Aggregate Flexible Resources

Increasing integration of distributed energy resources (DERs) within distribution feeders provides unprecedented flexibility at the distribution-transmission interconnection. With the new FERC 2222 order, DER aggregations are allowed to participate in energy market. To enable market participation, these virtual power plants need to provide their generation cost curves. This paper proposes efficient optimization formulations and solution approaches for the characterization of hourly as well as multi-time-step generation cost curves for a distribution system with high penetration of DERs. Network and DER constraints are taken into account when deriving these cost curves, and they enable active distribution systems to bid into the electricity market. The problems of deriving linear and quadratic cost curves are formulated as robust optimization problems and tractable reformulation/solution algorithm are developed to facilitate efficient calculations. The proposed formulations and solution algorithm are validated on a realistic test feeder with high penetration of flexible resources.

aggregated distributed energy resources↗

Ground-based Characterization of Plant Water Management (PWM) Hydroponic Root Modules for Spaceflight

Hydroponic crop production in space is crucial for long-term space travel but faces numerous challenges – one of which is providing sufficient dissolved oxygen (DO) in nutrient solution. In microgravity environments, surface tension is the primary force acting on liquids, causing water to form into suspended spherical droplets. This can suffocate plants as the liquid clings onto plant roots and the lack of aeration deprives the plant of oxygen needed for growth. To overcome these challenges, plant water management (PWM) systems explore options of growing plants in space autonomously and passively through capillary forces. From 2018-2023, there have been 6 PWM experiments conducted on the ISS. In past experiments conducted in microgravity, bubbles formed in test cells have disrupted fluid dynamics and may adversely affect plant growth. The accumulation of bubbles may lead to inconsistent nutrient delivery, break prime in tubing, and suspend plant roots in air, leading to plant stress and eventually death. Current research efforts focus on the oxygenation capabilities of the PWM system along with a comprehensive sensor array that will improve nutrient and DO monitoring capabilities.

L Wang↗

Distribution and metabolism of quaternary amines in salt marshes

Quaternary amines such as glycine betaine (GBT) are common osmotically active solutes in much of the marine biota. GBT is accumulated by various bacteria, algae, higher plants, invertebrates, and vertebrates in response to salinity or water stresses; in some species, GBT occurs at tens to hundreds of millimolar concentrations and can account for a significant fraction of total nitrogen. Initial studies suggest that GBT is readily converted to two potential methane precursors, trimethylamine (TMA) and acetate, in anoxic sediments. TMA is apparently the most important methane precursor in surface sediments containing sulfate reducing bacteria. In salt marshes, the bulk of the methane formed may be due to the metabolism of TMA rather than other substrates. Current research is focussed on testing this hypothesis and on determining the role of quaternary amino osmoregulatory solutes in methane fluxes from marine environments. Preliminary studies have dealt with several problems: (1) determination of GBT concentrations in the dominant flora and fauna of salt marshes; (2) synthesis of radiolabelled GBT for metabolic studies; and (3) determination of fates of BGT in marine sediments using radiotracers. Both GC and HPLC techniques have been used to assay GBT concentrations in plant and animal tissues. S. alterniflora is probably the only significant source of GBT (and indirectly of methane) since the biomass and distribution of most other species is limited. Current estimates suggest that S. alterniflora GBT could account for most of the methane efflux from salt marshes.

King, Gary M.↗

Proven Technologies for the Solidification of Complex Liquid Radioactive Waste (LRW): Global Case Studies of Applications and Disposal Options - 20424

Legacy radioactive waste streams from the Cold War still exist and newly generated waste streams from nuclear power plants and research institutes go untreated and expose environmental hazards at many nuclear sites. The nature of the waste is diverse, depending upon the source or the process from which it originated. The most problematic waste streams include complex liquids such as organic (tri-butyl-phosphate TBP) solutions contaminated with Pu and U isotopes, mixed sludge types, high acid radioactive waste, H-3 contaminated organic and aqueous streams, etc. Technological, environmental and economic challenges exist for the treatment and disposal of such waste streams. A proven technology that has been applied to LRW on a global basis provides one option as a low-cost solution to legacy streams and small volume, highly complex LRW frequently found during decommissioning at nuclear power plants and weapons sites. The engineered polymer technology from Nochar, USA, is capable of solidifying standard and highly complex LLW and ILW waste streams for interim or final storage, or for incineration. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Design of biomass management systems and components for closed loop life support systems

The design of a biomass management system (BMS) for use in a closed loop support system is presented by University of Florida students as the culmination of two design courses. The report is divided into two appendixes, each presenting the results of one of the design courses. The first appendix discusses the preliminary design of the biomass management system and is subdivided into five subsystems: (1) planting and harvesting, (2) food management, (3) resource recovery, (4) refurbishing, and (5) transport. Each subsystem is investigated for possible solutions to problems, and recommendations and conclusions for an integrated BMS are discussed. The second appendix discusses the specific design of components for the BMS and is divided into three sections: (1) a sectored plant growth unit with support systems, (2) a container and receiving mechanism, and (3) an air curtain system for fugitive particle control. In this section components are designed, fabricated, and tested.

Nevill, Gale E., Jr.↗

Photosynthetic Response to Long- and Short-Term Changes in Carbon Dioxide in Sweetpotatoes Grown Hydroponically with Enhanced Mineral Nutrition

Sweetpotato [Ipomoea batatas L.(Lam.)] has been selected by NASA as a potential food for long-term space missions. In previous experiments, sweetpotato plants grown hydroponically under elevated levels of CO2 depleted the nitrogen in the nutrient solution between the hi-weekly solution replacements. In this experiment, the effect of enhanced nutrient replenishment on photosynthetic rates of sweetpotato was determined. CO2 response curves were determined for "TU-82-155" and "Georgia-Jet" sweetpotatoes grown hydroponically in growth chambers at three different CO2 concentrations (400, 750, and 1000 micro-mol/mol CO2). Gas exchange measurements were made using infrared gas analysis, an open-flow gas exchange system, and a controlled-climate cuvette. Photosynthetic measurements were made at CO2 concentrations from 50-1000 micro-mol/mol CO2. Net photosynthetic rates showed an increase with increasing measurement CO2 in all nutrient regimes, but the response of photosynthetic rates to the growth CO2 conditions varied among the experiments and between the two varieties. Enhanced mineral nutrition led to increased net photosynthetic rates in "Georgia Jet" plants, but not in "TU-82-155" plants. The results of this study will help to determine the CO2 requirements for growth of sweetpotato on proposed space missions.

Hamilton, Casey↗

Plant Disease Detection: Exploring Applications in Hyperspectral Imaging and Machine Learning for Agriculture

The threat of crop disease on food security and agriculture is projected to escalate, leading to reduced crop yields, global economic loss, and endangered food availability to vulnerable populations. Early identification of plant disease is crucial to combatting the crisis but traditional manual methods for disease detection are laborious and may miss early signs of infection. The proposed solution suggests equipping a drone with a hyperspectral camera to collect images and analyzing the data with neural networks trained to flag and classify infected plants. This approach offers a faster, more accurate, and potentially more cost-effective alternative to current practices. While the expensive and complex nature of hyperspectral imaging (HSI) may be an obstacle to the adoption of the drone, rapidly advancing technologies compounded with rental-based usage may make these tools simpler, cheaper, and more accessible to a wider audience. The research further discusses the potential for automated flight paths and the expansion of disease detection to a broader range of crops.

plant disease detection↗

Converter-Interfaced CHP Plant for Improved Grid-Integration, Flexibility and Resiliency

GE Research and its partner GE Renewables have proposed the use of an interface converter solution to increase the penetration of small to medium-sized CHP (1MWe to 20MWe) into distribution grids and improve their flexibility and grid support capability. Indeed, the proposed interface converter solution thanks to presence of the grid-ready inverter, allows to streamline the compliance to grid codes requirements, reduce the interconnection delays and costs and ultimately one of the main barriers for CHP adoption by commercial and industrial facilities. An additional benefit provided by the interface converter is the use of the grid-ready inverter for reactive power which eliminates the need of sizing the generator for that capability. These two benefits highly favor the economic feasibility of converter-interfaced CHP. Five user cases, each in one of the leading U.S states for CHP potential reported by the DOE in its estimation of the U.S Technical Potential of CHP, were selected to compare the economic performances of converter-interfaced CHP as compared with directly-coupled. They include a college campus in California, a hospital in New York, a water reclamation plant in Texas, a hotel in Minnesota, and a large office building in Pennsylvania. Results showed that, the presence of the interface converter allows to increase the return on investment (ROI) by 0.5 to 2 percentage points in most of the cases (4 of 5). Indeed, the interface converter by shortening the interconnection process allows to accelerate revenues while reducing interconnection costs. Added to the reduced cost of the required generator these savings trade favorably the capital cost of the converter. The analysis also showed that the profitability of the converter-interfaced CHP is highly sensitive to the energy price, interconnection delay, and converter cost. However, it appears that if the interface converter can shorten the interconnection process by at least 6 months, adopting this solution will be more economically viable than directly-coupled configuration in almost all the +23,000 sites of the U.S Technical Potential CHP. The evaluation of the benefits of a converter-interfaced CHP also showed that it enables higher ROI when coupled with other distributed energy resources (DER) such as battery energy systems (BESS) or solar photovoltaic (PV). Indeed, in those scenario, the grid-ready inverter included in the interface converter eliminates the need of separate inverters if DC-coupling is used. On the technical performance, it has been verified that the presence of the interface converter allows to reduce by 70% to 80% the CHP short-circuit contribution to grid faults. This not only reduces the mechanical and thermal stresses exposed to the CHP electrical components but also increases the grid hosting capacity which ultimately enables higher penetrations CHP. Another key benefit of the interface converter validated with hardware-in-the-loop simulations and testing is its superior capability for reactive power support. Indeed, using a power hardware testbed with two +700kW inverters configured in back-to-back, a microgrid controller and actual facilities loads it was demonstrated that the presence of the interface converter can help maintain a power factor near ~1 or regulate the voltage to ~1.0pu at the point of common coupling. This benefit can be highly valuable if in the future, due to higher penetration of renewable distributed energy resources (DER), utilities start billing demand charge based on kVA instead of kW as currently. It was also validated that converter-interfaced CHP can dispatch heat and power commands and seamlessly switch between the two modes while consistently controlling the power factor or voltage at PCC. Indeed, the power hardware testing showed that grid-connected converter-interfaced CHP can follow either the power or heat demand while maintaining a unity power factor at converter output. This research proved that the adoption of an interface converter as the solution for interconnection of CHP system into the distribution grid can greatly improve the economic feasibility of small to medium-sized CHP as well as the plant power quality, flexibility and resiliency. Additionally, it allows increased penetrations of CHP into the distribution grid, extends their grid support capability, and facilitates the integration of BESS and PV DER by streamlining their collocation within the same facilities. This ultimately provides an opportunity for commercial and small industrial facilities in the U.S to accelerate their energy transition thanks to the high energy efficiency of CHP systems and its reliable, flexible, and resilient microgrid operation when interconnected with an interface converter.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Biomass and salt-dependent effects of Bacillus spores on radionuclide migration from the Waste Isolation Pilot Plant

Spores of a Bacillus sp., isolated from radioactive waste, were tested for their ability to influence the fate and transport of neodymium (Nd3+) under high salt conditions expected at the Waste Isolation Pilot Plant (WIPP) nuclear waste repository. Spores were suspended in neodymium-spiked saline solutions up to 4 M NaCl, and concentrations of Nd and the complexing agent dipicolinic acid (DPA), a component of spores, were monitored along with optical densities and spore numbers. Overall, results support neodymium bioassociation that is dependent upon biomass, with more apparent adsorption occurring at higher spore concentrations. However, probable spore lysis in 2 and 4 M NaCl solutions and possible germination at 0.15 M NaCl appear to drive the release of DPA and subsequent return of Nd to solution. The implications of this work for the WIPP will depend on actual biomass levels and the ionic strength of the repository brines.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A ranking methodology for the coupling of pressurized water nuclear reactors and molten salt thermal energy storage

Thermal energy storage (TES) systems are a proposed solution to electricity market demand fluctuations and can be coupled to nuclear power plants to enable load following. Here, this work focuses on developing a methodology for evaluating potential designs for integrating a TES system into an existing pressurized water nuclear power plant. The proposed ranking methodology allows a group of experts to postulate and weigh designs based on ranking criteria derived from literature. The methodology developed in this study can aid in the final selection of a TES design for an existing nuclear power plant. The same process could be used to analyze other TES and nuclear reactor designs. The determined optimum design from this methodology was to place the TES system after the steam generator and to utilize the steam generated from the nuclear power plant to heat a molten salt TES unit. Another conclusion of this research was that human bias is prevalent during design selection, and actions such as standardized ranking criteria and large groups of experts should be used to minimize this error.

25 ENERGY STORAGE↗

Power and particle exhaust for the ARC fusion power plant

To successfully show that fusion is an attractive energy source, the ARCTM fusion power plant will need to operate with a robust, integrated power and particle exhaust solution. To maximise ARC’s fusion power output while avoiding excessive erosion of the plasma-facing components, we will need to radiatively dissipate most of the power crossing the last-closed flux surface, injecting radiating impurities such as argon or neon to access divertor detachment. Divertor detachment will need to be integrated with a high-performance core plasma, and with efficient impurity pumping to prevent the accumulation of helium ash in the core. To access and control detachment in high-performance plasmas, we have designed ARC with up–down-symmetric divertors, with secondary X-points in long, tightly baffled outer legs. Using a core-edge modelling workflow, we predict that with this divertor design, ARC will access detachment with modest argon seeding in the divertor (c Ar,div ∼0.9%), which should have minimal impact on the core ( Z eff,core <0.5) for reasonable argon enrichment (c Ar,div /c Ar,core =6). Due to the high predicted divertor neutral pressure (p div ∼20 Pa), we predict that ARC will sufficiently pump helium to limit ash accumulation in the core (c He,core <2%) for a helium enrichment of c He,div /c He,core =0.4. ARC’s divertor design is expected to increase the stability of a detachment front in the outer divertor leg, helping to prevent divertor reattachment during smaller heat-flux transients such as scrape-off-layer filaments associated with the quasi-continuous exhaust regime. However, this buffering will not be sufficient to prevent divertor reattachment during large type-I edge-localised modes (ELMs), and as such these will need to be avoided on ARC. Experiments on SPARC will be used to select an integrated scenario which avoids or mitigates type-I-ELMs while maintaining access to detachment, good core fusion performance and sufficient impurity exhaust. SPARC experiments will also be used to finalise ARC’s divertor design, by studying the impact of magnetic and first-wall geometry on detachment stability, impurity enrichment and neutral baffling under conditions similar to those expected for ARC. In conclusion, our analysis finds that ARC will have a viable power and particle exhaust solution which is compatible with high-power operations, and this solution will be validated in experiments on SPARC.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Cesium Ion Exchange Testing Using Crystalline Silicotitanate with Hanford Tank Waste 241-AP-107

At the time of this testing, the Low-Activity Waste Pretreatment System (LAWPS) was to provide for the initial production of immobilized low-activity waste by feeding Hanford tank supernate from tank farms to the Hanford Tank Waste Treatment and Immobilization Plant (WTP) Low-Activity Waste (LAW) Facility for immobilization. Washington River Protection Solutions requested that Hanford tank waste collected from tank 241-AP-107 (hereafter called AP-107) be processed using conceived pretreatment steps (suspended solids removal by filtration, Cs removal by ion exchange) then vitrified. A small-scale test platform to demonstrate the solids filtration, Cs removal, and LAW vitrification was constructed and installed at Pacific Northwest National Laboratory. Bench-scale ion exchange testing with approximately 9 L of AP-107 supernate was conducted using crystalline silicotitanate (CST) ion exchange media. The IONSIV R9140-B CST was provided by Honeywell UOP, LLC in 2018 (Batch 2081000057). The ion exchange media was first tested with simulant and was previously described. This report describes the Cs ion exchange batch contact and column test results with the AP-107 tank waste. Batch contact testing helps to evaluate CST performance on tank waste supernate prior to processing it in the ion exchange columns. Batch contacts were performed with the waste at four Cs concentrations at a phase ratio of 200 (liquid volume to exchanger mass) with AP-107. The distribution coefficient (K d ) at the equilibrium condition of 8.57 µg Cs/mL (AP-107 feed condition) was determined to be 669 mL AP-107/g CST. With a CST bed density of 1.00 g/mL, this K d corresponded to a predicted 50% Cs breakthrough of 669 bed volumes (BVs). The Cs load capacity at the equilibrium feed condition was determined to be 7.5 mg Cs/g dry CST. The column testing was prototypic to the intended LAWPS operations in a lead-lag column format, although on a small-scale basis with 10-mL CST beds. The feed was processed downflow through the lead column and then through the lag column at ~2.2 BV/h. Loading continued until the lag column reached the WTP waste acceptance criteria (WAC) for receiving supernatant waste for vitrification (a function of the Na and 137 Cs concentrations). For AP-107, the WAC is 0.114% of the influent 137 Cs concentration; this required a Cs decontamination factor of 876. The Cs effluent from the lag column reached the WAC after processing ~410 BVs. To keep the subsequent product effluent below the WAC, a replacement lag column was prepared, the lead column was removed from service (after processing a total of 471 BVs), the lag column was put into the lead column position, and the replacement lag column was installed. Feed processing continued and after another ~290 BVs the Cs effluent from the lag column again exceeded the WAC. In both cases, the lead columns only reached 25% Cs breakthrough before removal. Although 50% Cs breakthrough was not reached, this value was estimated and averaged based on extrapolation of the loading curves (640 BVs) and agreed within 4% of the predicted 50% Cs breakthrough from batch contact test results (669 BVs). Table ES.1 summarizes the observed column performance and relevant Cs loading characteristics.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Algorithms and file structures to enhance software workflows for ion mobility mass spectrometry (IM-MS): CRADA 410 (Final Report)

This document is the final report for CRADA 410 (Project No. 72496). The purpose of this project was supporting customizations of algorithms and raw data file structures to enhance software workflows for liquid chromatography (LC), mass spectrometry (MS) and ion mobility mass spectrometry (IM-MS)-based metabolite characterization. PNNL worked with Agilent to evaluate and improve the integration of ion mobility into existing MS data analysis methods of Agilent software tools. The project augmented PNNL’s capabilities to analyze complex omics samples. These capabilities are directly beneficial to DOE and PNNL efforts to characterize and analyze compounds in microbial and plant communities. The project assisted Agilent in further developing improved instrument-software solutions combining ion mobility with mass spectrometry for widespread applications in life sciences and other fields.

97 MATHEMATICS AND COMPUTING↗

Algorithms and file structures to extend and enhance liquid chromatography and ion mobility mass spectrometry workflows (CRADA Final Report)

The purpose of this project was to continue supporting customizations of algorithms and raw data file structures to enhance software workflows for liquid chromatography (LC), mass spectrometry (MS) and ion mobility mass spectrometry (IM-MS)-based protein and metabolite characterization. PNNL worked with Agilent to design, implement, evaluate, and demonstrate new algorithms and integrated them as functionalities into the PNNL-PreProcessor software. The project augmented PNNL’s capabilities to analyze complex proteomics and metabolomics samples. These capabilities are directly beneficial to DOE and PNNL efforts to characterize and analyze these compounds in microbial and plant communities. The project assisted Agilent in further developing improved instrument-software solutions combining liquid chromatography and ion mobility with mass spectrometry for widespread applications in life sciences and other fields.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Microreactor Automated Control System - Digital Twin Models and Advanced Control Systems Updates

Automation of control systems is expected to be important in the economic and safe operation of microreactors. Therefore, there is a need to develop and demonstrate automated control for microreactors, along with the development of testbeds for this purpose. This report provides updates on the status of a nonnuclear microreactor automated control system (MACS)—a real-time, hardware-in-the-loop testbed for non-nuclear testing of microreactor control system automation. A real-time hardware-in-the-loop testbed incorporates the realistic dynamics of physical systems into control system development and testing. The collaborative effort between Oak Ridge National Laboratory (ORNL) and Idaho National Laboratory (INL) resulted in the development of a prototypic microreactor plant-level digital twin that includes the reactor and a balance of plant system. Advanced control strategies were incorporated to demonstrate testing of control automation solutions. The gRPC communication protocol, which was implemented in the hardware-in-the-loop testbed by INL, was coupled to a digital twin model developed using the TRANsient Simulation Framework of Reconfigurable Models (TRANSFORM) library in Modelica. This digital twin simulation was tested with the ViBRANT hardware for realistic feedback and visual representation of control action in real time. A modular Python client structure was developed to manage functional mock-up unit-based simulation and real-time gRPC communication. Hardware-in-the-loop testing indicated that the modeled reactor—a natural-convection, molten-salt coolant loop configuration—responds well to control of drum positioning for modulation of reactor core power, as well as system-level control and downstream demand changes. Ongoing research is focused on integrating additional control algorithms that utilize data from newly included sensors within the MACS hardware testbed, as well as demonstrating and assessing the performance of the different automated control algorithms on multiple additional operational scenarios.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Specific-optimal control with a dual minimal-order observer-based compensator

The steady-state optimal control of a linear time-invariant stochastic system by means of a minimal-order dual-observer-based compensator is considered in this paper. The structure of the compensator is fixed while the associated gains are to be chosen so as to minimize a quadratic penalty on the plant state. Necessary and sufficient conditions for optimality are given, and an explicit solution is displayed. Salient features pertaining to the optimal system are: a decoupling property, a projection property, and an innovation property. Finally, it is shown that this design corresponds to a singular LQG problem, which is precisely the dual of another singular LQG problem: namely Newmann's problem. A complete picture is then given showing clearly the correspondence between the two designs.

Blanvillain, P. J.↗

Bismaleimide resins for flame resistant honeycomb sandwich panels

A 60 kg batch of Resin M751 was produced in pilot plant scale. The resin was delivered to the prepreg company as an NMP solution. 100 kg of glass-fabric prepregs were fabricated. Prepreg characteristics and curing cycles for laminate fabrication were provided. A new batch of Resin M756 (Code M756 - 2) was synthesized.

Source record↗