Search NASA⌕ Search

SEARCH · Search NASA

Results for “plug loads”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Skylab Rescue Space Vehicle OAT No. 1 Plugs in Test

A test is described which demonstrates the compatibility of the Skylab Rescue Space Vehicle systems, the ground support equipment, and off-site support facilities by proceeding through a simulated launch countdown, liftoff, and flight. The functions of propellant loading, umbilical ejection, holddown arm release, service arm retraction, liftoff, and inflight separation are simulated. An external power source supplies transfer power to internal, and instrument unit commands are simulated by the digital command system. The test outline is presented along with a list of references, intercommunications information, radio frequency matrix, and interface control chart.

Jevitt, S. J.↗

Reusable Hot-Wire Cable Cutter

During the early development stage of balloon deployment systems for missions, nichrome wire cable cutters were often used in place of pyro-actuated cutters. Typically, a nichrome wire is wrapped around a bundle of polymer cables with a low melting point and connected to a relay-actuated electric circuit. The heat from the nichrome reduces the strength of the cable bundle, which quickly breaks under a mechanical load and can thus be used as a release mechanism for a deployment system. However, the use of hand-made heated nichrome wire for cutters is not very reliable. Often, the wrapped nichrome wire does not cut through the cable because it either pulls away from its power source or does not stay in contact with the cable being cut. Because nichrome is not readily soldered to copper wire, unreliable mechanical crimps are often made to connect the nichrome to an electric circuit. A self-contained device that is reusable and reliable was developed to sever cables for device release or deployment. The nichrome wire in this new device is housed within an enclosure to prevent it from being damaged by handling. The electric power leads are internally connected within the unit to the nichrome wire using a screw terminal connection. A bayonet plug, a quick and secure method of connecting the cutter to the power source, is used to connect the cutter to the power leads similar to those used in pyro-cutter devices. A small ceramic tube [0.25-in. wide 0.5-in. long (.6.4-mm wide 13-mm long)] houses a spiraled nichrome wire that is heated when a cable release action is required. The wire is formed into a spiral coil by wrapping it around a mandrel. It is then laid inside the ceramic tube so that it fits closely to the inner surface of the tube. The ceramic tube provides some thermal and electrical insulation so that most of the heat generated by the wire is directed toward the cable bundle in the center of the spiral. The ceramic tube is cemented into an aluminum block, which holds it in position. The leads of the nichrome wire are attached to screw terminals that connect them to power leads. A bayonet plug mounted at the bottom of the rectangular block connects the power leads to a relay circuit. A thin aluminum shell encloses the entire structure, leaving access points to attach to the bayonet plug and to feed a cable into the cylinder. The access holes for the deployment cable are a smaller diameter than the nichrome coil to prevent the cable from coming in direct contact with the nichrome when loaded. It uses the same general method of severing a cable with a heated wire as was used previously, but implements it in such a way that it is more reliable and less prone to failure. It creates a mechanism to create repeatability that was nonexistent in the previous method.

Pauken, Michael T.↗

Plug-in Hybrid Electric Vehicle Value Proposition Study - Final Report

PHEVs have been the subject of growing interest in recent years because of their potential for reduced operating costs, oil displacement, national security, and environmental benefits. Despite the potential long-term savings to consumers and value to stakeholders, the initial cost of PHEVs presents a major market barrier to their widespread commercialization. The study Objectives are: (1) To identify and evaluate value-added propositions for PHEVs that will help overcome the initial price premium relative to comparable ICEs and HEVs and (2) to assess other non-monetary benefits and barriers associated with an emerging PHEV fleet, including environmental, societal, and grid impacts. Study results indicate that a single PHEV-30 on the road in 2030 will: (1) Consume 65% and 75% less gasoline than a comparable HEV and ICE, respectively; (2) Displace 7.25 and 4.25 barrels of imported oil each year if substituted for equivalent ICEs and HEVs, respectively, assuming 60% of the nation's oil consumed is imported; (3) Reduce net ownership cost over 10 years by 8-10% relative to a comparable ICE and be highly cost competitive with a comparable HEV; (4) Use 18-22% less total W2W energy than a comparable ICE, but 8-13% more than a comparable HEV (assuming a 70/30 split of E10 and E85 use in 2030); and (5) Emit 10% less W2W CO{sub 2} than equivalent ICEs in southern California and emits 13% more W2W CO{sub 2} than equivalent ICEs in the ECAR region. This also assumes a 70/30 split of E10 and E85 use in 2030. PHEVs and other plug-in vehicles on the road in 2030 may offer many valuable benefits to utilities, business owners, individual consumers, and society as a whole by: (1) Promoting national energy security by displacing large volumes of imported oil; (2) Supporting a secure economy through the expansion of domestic vehicle and component manufacturing; (3) Offsetting the vehicle's initial price premium with lifetime operating cost savings (e.g., lower fuel and maintenance costs); (4) Supporting the use of off-peak renewable energy through smart charging practices. However, smart grid technology is not a prerequisite for realizing the benefits of PHEVs; and (5) Potentially using its bidirectional electricity flow capability to aid in emergency situations or to help better manage a building's or entire grid's load.

02 PETROLEUM↗

A Study of a Diesel Engine Based Micro-CHP System

This project, funded by New York State Energy Research and Development Agency (NYSERDA), investigated the potential for an oil-fired combined heat and power system (micro-CHP system) for potential use in residences that use oil to heat their homes. Obviously, this requires the power source to be one that uses heating oil (diesel). The work consisted of an experimental study using a diesel engine and an analytical study that examined potential energy savings and benefits of micro-CHP systems for 'typical' locations in New York State. A search for a small diesel engine disclosed that no such engines were manufactured in the U.S. A single cylinder engine manufactured in Germany driving an electric generator was purchased for the experimental work. The engine was tested using on-road diesel fuel (15 ppm sulfur), and biodiesel blends. One of the main objectives was to demonstrate the possibility of operation in the so-called HCCI (Homogeneous Charge Compression Ignition) mode. The HCCI mode of operation of engines is being explored as a way to reduce the emission of smoke, and NOx significantly without exhaust treatment. This is being done primarily in the context of engines used in transportation applications. However, it is felt that in a micro-CHP application using a single cylinder engine, such an approach would confer those emission benefits and would be much easier to implement. This was demonstrated successfully by injecting the fuel into the engine air intake using a heated atomizer made by Econox Technologies LLC to promote significant vaporization before entering the cylinder. Efficiency and emission measurements were made under different electrical loads provided by two space heaters connected to the generator in normal and HCCI modes of operation. The goals of the analytical work were to characterize, from the published literature, the prime-movers for micro-CHP applications, quantify parametrically the expected energy savings of using micro-CHP systems instead of the conventional heating system, and analyze system approaches for interaction with the local electric utility. The primary energy savings between the space heating provided by a conventional space heating system with all the required electrical energy supplied by the grid and the micro-CHP system supplemented when needed by a conventional space heating and the grid supplied electricity. were calculated for two locations namely Long Island and Albany. The key results from the experimental work are summarized first and the results from the analytical work next. Experimental results: (1) The engine could be operated successfully in the normal and HCCI modes using both diesel and biodiesel blends. (2) The smoke levels are lower with biodiesel than with diesel in both modes of operation. (3) The NOx levels are lower with the HCCI mode of operation than with the normal mode for both fuels. (4) The engine efficiency in these tests is lower in the HCCI mode of operation. However, the system parameters were not optimized for such operation within the scope of this project. However, for an engine designed with such operation in mind, the efficiency would possibly be not lower. Analytical results: (1) The internal combustion engine (diesel engine in this case) is the only proven technology as a prime mover at present. However, as noted above, no U.S. engine is available at present. (2) For both locations, the use of a micro-CHP system results in primary energy savings. This is true whether the CHP system is used only to supply domestic hot water or to supply both hot water and space heat and even for a low efficiency system especially for the latter case. The size of the thermal storage (as long as it above a certain minimum) did not affect this. (3) For example, for a 2 kW CHP electrical efficiency of 25%, a typical house on Long Island will save about 30MBtu of energy per year for a combined space heat and domestic hot water system. This corresponds to annual energy savings of about 210 gallons oil equivalent per (4) The savings increased initially with the power capacity of the prime-mover, but flattened out at around 2 kW power output suggesting that a low power engine like the one tested is a good choice. (5) Reverse metering, that is, power returned to the electric grid when produced in excess of the local load, increased the primary energy savings significantly when using a 3kW to 5kW system with high fuel-to-electric efficiency. (6) In view of the current interest in plug-in electric or hybrid vehicles, the impact of night-time recharging on the micro-CHP operation was considered. Obviously, it will reduce the amount reverse metered and without reverse-metering, the primary energy savings were increased significantly. (7) The micro-CHP systems can contribute to the decrease of the carbon emissions of the local utility even with the use of diesel fuel and much more so with biodiesel use.

02 PETROLEUM↗

Ferroresonant Flux-Coupled Battery Charger

Portable battery charger operates at about 20 kHz to take advantage of relatively low weight and low acoustical noise of ferroresonant circuits operating in this frequency range. Charger split into stationary unit connected to powerline and mobile unit connected to battery or other load. Power transferred to mobile unit by magnetic coupling between mating transformer halves. Advantage where sparking at electrical connection might pose explosion hazard or where operator disabled and cannot manipulate plug into wall outlet. Likely applications for charger include wheelchairs and robots.

Mclyman, C. W.↗

Capillary electrophoresis: Imaging of electroosmotic and pressure driven flow profiles in fused silica capillaries

This study is a continuation of the summer of 1994 NASA/ASEE Summer Faculty Fellowship Program. This effort is a portion of the ongoing work by the Biophysics Branch of the Marshall Space Flight Center. The work has focused recently on the separation of macromolecules using capillary electrophoresis (CE). Two primary goals were established for the effort this summer. First, we wanted to use capillary electrophoresis to study the electrohydrodynamics of a sample stream. Secondly, there was a need to develop a methodology for using CE for separation of DNA molecules of various sizes. In order to achieve these goals we needed to establish a procedure for detection of a sample plug under the influence of an electric field Detection of the sample with the microscope and image analysis system would be helpful in studying the electrohydrodynamics of this stream under load. Videotaping this process under the influence of an electric field in real time would also be useful. Imaging and photography of the sample/background electrolyte interface would be vital to this study. Finally, detection and imaging of electroosmotic flow and pressure driven flow must be accomplished.

Williams, George O., Jr.↗

Design of P-3 Nadir Port

This project details the design and analysis of a structure to replace the interface of the P-3B nadir port with an optimized interface for science installations. A new nadir port plug has been designed to replace the OEM (Original Equipment Manufacturer) plug (Lockheed PN 910169) currently used in Nadir ports 1 and 2 on the NASA P-3B aircraft. The plug consists of a milled frame that can be outfitted with customizable flat plates to meet a broad range of science needs. The frame slides into place using the existing P-3B rail system using a lever and tie-rod assembly. The seal interface will contact the Fuselage skin of the aircraft and consists of a bulb E-seal that is riveted around the perimeter of the frame. The flat plate (20 inches x 31 inches) provides a large profile that can be outfitted based on science mission goals and requirements to attach multiple instruments. This is a significant increase to the aircraft capability. Previously, the OEM plug had to be modified to hold very small plates, windows, or instruments limiting the use of the ports.There were several challenges for this project that included a constrained schedule, lack of historical references, and reverse engineering. The unusually tight schedule for design, manufacture, and install limited potential approaches. In addition, design of a new interface to replace the existing plug, on an aircraft designed in the 1960's by Lockheed for the Navy with little to no documentation, required substantial reverse engineering. In order to accomplish this, a suitable method to determine interface requirements with the aircraft had to be solved. After several iterations, the solution was to implement laser scanning techniques to scan the aircraft and the OEM plug and generate a 3D model to capture the design envelope. The structure is designed to maintain a positive margin of safety when subjected to the inertial, pressure, and aerodynamic load requirements for an external installation on the P-3B, as described in the Wallops' P-3B Design Requirements 548-RQMT-0001 Rev. A . A finite element model is created in FEMAP (Finite Element Modeling And Postprocessing) and is run through NX Nastran solver to analyze the structure. After several iterations of analysis, the structure was enveloped to hold 115 pounds evenly distributed on the plate.

Chance, Monica↗

Twenty years of dry interim storage of spent nuclear fuel (SNF) in Germany- History and developments - 15575

According to article 6 of the German Atomic Energy Act, storage of nuclear fuel requires a license granted by the competent authority in this field, which is the Federal Office of Radiation Protection. In 1983 a license to store spent nuclear fuel (SNF) and later expanded for vitrified high level waste (HAW) for the interim storage facility in Gorleben was granted. Dry Interim storage at the NPP sites in its actual form started in 2002 in the interim storage facility next to the NPP Lingen. Since this time each NPP erected its own storage facility and three central storage facilities have been built. All of these facilities use dry storage in metallic casks. The actual storage licenses for SNF and the HAW (which is stored in Gorleben and Rubenow) are limited to 40 years starting with the first cask emplacement. As no opening of the cask is intended during the storage period the condition of the inventory and the cask before loading has to be known in detail. This requires for instance detailed knowledge of the history of the SNF loaded as well as supervision of the manufacturing process of the cask. Within the last twenty years several mishaps influenced the regulatory point of view. During a loading campaign in a boiling water reactor traces of pool water remained in the gasket slot and during the drying procedure crystalline boron salts prevented the required tightness. After that event a long-term experiment was started and is still going on which studies the effects of water and minor damages to the gasket. As well changes in the loading procedure have been introduced. The pressure switch used to monitor the pressure in the space between primary and secondary lid has a self surveillance function. This indicated a malfunction 23 times in the last twenty years. Examinations of all events indicated no systematic failure, but a weak point seems to be the plug-in connection. The manufacturer introduced some modifications to improve the system. Introduction of FEM methods in safety analysis to amend the existing methods of testing allowed a new view on and in the cask safety analysis. Progress in this field is closely connected to the available computing capacity and stipulates experts to ongoing improvement. After expiring of the storage license which will be the case for the first cask loaded in 1992 and stored in Ahaus 2032 an extension or a new license can only be granted if the at this time relevant requirements are met. This will require detailed knowledge about the happenings and accidents during the previous storage period. All experience of the periodic safety assessment (PSA) which started in 2013 and accompanying experiments conducted till now and during the licensed storage time will be needed. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Salt Repository Concept for CSNF in 21-PWR Size Canisters

The most straightforward concept for disposal of large, heavy packages containing commercial spent nuclear fuel (CSNF) in a repository in bedded salt, would be to emplace them directly on the floor in emplacement tunnels. In-tunnel axially aligned horizontal emplacement would minimize excavated volume and avoid drilling of large-diameter emplacement boreholes. A similar concept was proposed in Germany for direct disposal of POLLUX ® canisters. The repository would be constructed at a depth of 500 to 1,000 m for isolation from the surface, and for sufficient overburden stress to ensure creep reconsolidation of repository openings. It could entail modular panels of emplacement tunnels arranged on headings oriented in cardinal directions from a central core, to accommodate the estimated 140,000 MTU total U.S. CSNF inventory. To do so, the overall area of the repository layout would be approximately 20 km 2 . Many layouts are possible, but the approach should be modular, excavation should be deferred for as long as possible to avoid maintenance, and the emplacement areas should share support facilities and shafts. Vertical shafts would be used in accordance with mining practice in sedimentary basins. Large diameter shafts would be needed for ventilation exhaust and waste transport, with smaller shafts for waste salt removal, men & materials, and ventilation intake. The spacing between disposal tunnels as estimated from thermal modeling, seeks to limit the maximum average areal thermal load in the panels to 11 W/m 2 to control long-term heat buildup in the host rock. Peak salt temperature would occur within a few years and would be dominated by each waste package locally, simplifying thermal management. There would be some flexibility to decrease the package spacing or increase the emplacement thermal power limit Backfilling emplaced waste packages immediately with mine-run crushed salt would provide shielding and expedite reconsolidation. This arrangement would isolate adjacent waste packages from one another by the intervening backfill, especially after it reconsolidates and its properties approach those of intact salt. After the repository is fully loaded and the performance confirmation program is complete, activities to permanently close the repository would be initiated. During closure operations all openings in the host salt would be backfilled, then shafts would be sealed, and boreholes plugged. Plans for the Waste Isolation Pilot Plant (WIPP) show how sealing and plugging could be done. A monitoring program could continue for 50 years or longer after repository closure. With an emplacement thermal power limit of 10 kW per waste package, nearly all the CSNF that is projected to be produced by the current fleet of reactors in the U.S. could be emplaced over a period of approximately 50 years starting in calendar 2048. No barriers to implementation in a reasonable timeframe have been identified from this generic analysis. Engineering challenges include: 1) shaft construction; 2) a very-large capacity shaft hoist; 3) overpack design; 4) a transport-emplacement-vehicle (TEV) for transporting waste packages once they are underground and emplacing them remotely; and 5) remotely operated equipment for emplacing backfill. The method of shaft construction would depend on site-specific conditions, and could involve freezing the subsurface. A shaft hoist with payload capacity of 175 MT seems technically and economically feasible based on development work in Germany, and it would be the largest hoist of its kind. The function of disposal overpacks would be to provide reliable containment during repository operations, which could be accomplished using a corrosion allowance material such as a low-carbon steel. Development effort would be needed to determine overpack thickness (e.g., 7 to 20 cm) that can resist corrosion and loading from salt creep, to rovide containment throughout the repository operational period. The transport-emplacement vehicle (TEV) would be similar to previous concepts, particularly one option proposed for a Yucca Mountain repository. It would move over a rough salt floor on independently driven and steered wheels, and carry heavy shielding in addition to a waste package. By analogy to the safety case for the WIPP in New Mexico, human intrusion is likely to be the dominant mode of radionuclide release from the repository. Treatment of human intrusion for a CSNF repository in salt could depend on promulgation of site-specific changes in the regulations. Radionuclide release and migration would be quite limited for undisturbed conditions. There may be opportunities for improved understanding of salt performance with waste heating, based on future in situ testing in an underground salt research laboratory. This report also discusses a developing area of salt rock mechanics that involves low-stress, low strain-rate creep that might cause large, heavy waste packages to slowly sink. Site-specific sampling, testing, and modeling would be used to determine if the mechanism is important enough to merit consideration in design, or inclusion in performance assessment. Part of engineering design and postclosure safety assessment for a CSNF repository in salt would be to implement a methodology to show that the probability of a criticality event in the repository, when waste packages eventually breach and are flooded, is less than the probability screening threshold for performance assessment. In the methodology, a criticality analysis would be performed for waste packages in the repository, incorporating measures that could be introduced as needed to limit reactivity, for example using fuel selection and loading rules, and crediting the absorption of thermal neutrons by natural chlorine in the environment. A similar analysis has been underway for CSNF stored in dual-purpose canisters. Ideally the strategy would be developed prior to actually loading SNF assemblies into canisters used in waste packages for disposal.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

An economic and technical feasibility analysis of a dual-source heat pump using both the air and the ground

The study investigates the economic and technical performance of a novel dual-source heat pump (DSHP) compared with that of air-source heat pumps (ASHPs) and ground-source heat pumps (GSHPs). The DSHP can use both ambient air and the ground as a heat source or heat sink. It uses ambient air when its temperature is favorable for efficient heat pump operation. When the ambient temperature is too hot or cold, the ground source is used to retain high-efficiency heat pump operation. Since the DSHP can alternately use either the ground heat exchanger (GHE) or ambient air to meet the thermal load, the required size of GHE can be smaller than those of GSHPs. This study models the DSHP using a whole building energy simulation tool (EnergyPlus) coupled with a Python plug-in and Heat Pump Design Model (HPDM) to simulate its heating and cooling performance for a typical single-family home in 15 US climate zones. The required GHE size of the DSHP system is determined through simulations and compared with that of GSHPs. DSHP deployment can reduce electricity use compared to ASHPs, especially in cold climates where it shows a reduction of around 50%. When compared to GSHPs, DSHPs use 20%–40% more electricity in warm climates but consume around the same amount in moderate and colder climates. Since the DSHP can use air source when the ambient temperature is mild, the GHE size needed for the DSHP is about 40% less than that needed for GSHPs in hot climates and about 25% less in cold climates. In conclusion, the life cycle cost analysis shows that the DSHP is economically more feasible than ASHPs in colder regions and economically more feasible than GSHPs in hot and cold regions.

Dual-source heat pumps↗

Using Electric Vehicles to Mitigate Imbalance Requirements Associated with an Increased Penetration of Wind Generation

The integration of variable renewable generation sources continues to be a significant area of focus for power system planning. Renewable portfolio standards and initiatives to reduce the dependency on foreign energy sources drive much of the deployment. Unfortunately, renewable energy generation sources like wind and solar tend to be highly variable in nature. To counter the energy imbalance caused by this variability, wind generation often requires additional balancing resources to compensate for the variability in the electricity production. With the expected electrification of transportation, electric vehicles may offer a new load resource for meeting all, or part, of the imbalance created by the renewable generation. This paper investigates a regulation-services-based battery charging method on a population of plug-in hybrid electric vehicles to meet the power imbalance requirements associated with the introduction of 11 GW of additional wind generation into the Northwest Power Pool. It quantifies the number of vehicles required to meet the imbalance requirements under various charging assumptions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Java Application Shell: A Framework for Piecing Together Java Applications

This session describes the architecture of Java Application Shell (JAS), a Swing-based framework for developing interactive Java applications. Java Application Shell is being developed by Commerce One, Inc. for NASA Goddard Space Flight Center Code 588. The purpose of JAS is to provide a framework for the development of Java applications, providing features that enable the development process to be more efficient, consistent and flexible. Fundamentally, JAS is based upon an architecture where an application is considered a collection of 'plugins'. In turn, a plug-in is a collection of Swing actions defined using XML and packaged in a jar file. Plug-ins may be local to the host platform or remotely-accessible through HTTP. Local and remote plugins are automatically discovered by JAS upon application startup; plugins may also be loaded dynamically without having to re-start the application. Using Extensible Markup Language (XML) to define actions, as opposed to hardcoding them in application logic, allows easier customization of application-specific operations by separating application logic from presentation. Through XML, a developer defines an action that may appear on any number of menus, toolbars, and buttons. Actions maintain and propagate enable/disable states and specify icons, tool-tips, titles, etc. Furthermore, JAS allows actions to be implemented using various scripting languages through the use of IBM's Bean Scripting Framework. Scripted action implementation is seamless to the end-user. In addition to action implementation, scripts may be used for application and unit-level testing. In the case of application-level testing, JAS has hooks to assist a script in simulating end-user input. JAS also provides property and user preference management, JavaHelp, Undo/Redo, Multi-Document Interface, Single-Document Interface, printing, and logging. Finally, Jini technology has also been included into the framework by means of a Jini services browser and the ability to associate services with actions. Several Java technologies have been incorporated into JAS, including Swing, Internal Frames, Java Beans, XML, JavaScript, JavaHelp, and Jini. Additional information is contained in the original extended abstract.

Miller, Philip↗

Variance Decomposition of MEDLI2 Reconstructed Heating Using Neural Networks

The Mars Entry, Descent, and Landing Instrumentation (MEDLI2) sensor suite collected data during entry of the Mars 2020 Perseverance rover into Mars’ atmosphere. An inverse estimation of the backshell and heatshield surface aeroheating was performed, using the data from the MEDLI2 Instrumented Sensor Plugs, a network of thermocouples embedded within the thermal protection system across the aeroshell. Monte Carlo analysis was conducted to assess the sensitivity of the surface heat rate, temperature, and heat load to uncertainties in thermocouple depth and material properties. In this paper, a variance decomposition method using Sobol indices was employed to understand the relative contributions of each uncertainty parameter. Performing this analysis using results from the inverse analysis tool FIAT_Opt was found to require incredibly high computation time, and thus machine learning models were trained and evaluated as a surrogate model for FIAT_Opt. This paper demonstrates that machine learning models can be an efficient, accurate alternative to state-of-the-art inverse analysis tools like FIAT_Opt, especially for computationally-expensive processes. Using these models, the sensitivity analysis showed that uncertainties in heat capacity and thermal conductivity were the main drivers for the overall uncertainty in peak reconstructed heating and heat load.

H S Alpert↗

Damaged Fuel in the United States - 20325

Throughout the history of commercial nuclear power plant operations in the U.S., many fuel assemblies have lost the capability to perform all of their desired functions. Since they can no longer be handled, stored, or transported in accordance with established regulations, they are classified as damaged fuel. The causes of these failed assemblies are diverse and plant-specific. The majority of these failed assemblies are contained in damaged fuel cans to be used in conjunction with storage and/or transportation systems. These systems have a limited number of slots that can be filled with damaged fuel cans. A damaged fuel can is generally a stainless-steel container that confines damaged spent nuclear fuel (SNF) and is closed at one end by mesh endpoints that allow gaseous and liquid media to escape but minimize the dispersal of gross particulate material. Out of extreme caution, a few reactors have loaded high burnup fuel into damaged fuel cans. Damaged fuel is not licensed for storage or transport in the U.S. because relevant regulations do not specify exactly how to classify damaged fuel. Instead, these regulations license/certify packages that specify approved contents. Damaged fuel must be included among the approved contents to be considered acceptable. In many cases, damaged SNF is encapsulated in damaged fuel cans to ensure it can confine gross fuel particles, debris, and/or damaged assemblies to known volumes within loaded casks. A damaged fuel can may then be utilized in the same way as an assembly in a storage and transportation system. Some storage cask systems utilize top and bottom plugs to confine debris in damaged fuel. The most recent domestic documentation on damaged SNF was published by the U.S. Energy Information Administration (EIA), which used data from U.S. reactors compiled from 1968 to June 30, 2013, to produce Form GC-859, 'Nuclear Fuel Data Survey.' According to this form, there were 136,821 boiling water reactor (BWR) SNF assemblies and 104,647 pressurized water reactor (PWR) SNF assemblies, for a combined total of 241,468. Of these, 4,521 were classified as failed. Some were also disassembled and the fuel rods or pieces of fuel rods combined to make consolidated assemblies. These consolidated assemblies may include damaged fuel or were perhaps consolidated as part of a demonstration project. The GC-859 data includes 2,550 consolidated assemblies containing 0 - 264 entire fuel rods. These consolidated assemblies could be placed in single assembly canisters and stored in the spent fuel pool. For dry storage and transportation, a single assembly canister is generally placed in each damaged fuel can. In addition to the consolidated assemblies, 2,391 un-canistered fuel rod pieces exist, which were removed from 494 assemblies. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

88 kilowatt automotive inverter with new 900 Volt silicon carbide MOSFET technology

This final report is on the design and experimental verification of a 200 kVA traction inverter using three 900 V, 2.5 mΩ, SiC MOSFET-based half-bridge power modules comprising the power stage. Each dual power module contains four 900 V, 10 mΩ SiC MOSFETs per switch position and uses synchronous conduction to achieve high average and peak efficiencies over its entire operating region to meet the demands of hybrid, plug-in hybrid, and extended-range electrified vehicle architectures. Significant performance improvement, via conduction, switching, and reverse-recovery loss metrics, from this SiC MOSFET-based inverter—especially at light load conditions—will be discussed.

30 DIRECT ENERGY CONVERSION↗

Damaged Fuel in the United States

Over the years of commercial nuclear power plant operations in the United States (U.S.), many fuel assemblies have lost the capability to perform all of their desired functions. These assemblies have lost the capability to be handled, stored, or transported to meet regulations resulting in them being classified as damaged fuel. The causes of these failed assemblies are diverse and plant-specific. The majority of these failed assemblies are contained in a damaged fuel can that will be used in conjunction with a storage and/or transportation system. The storage and transportation systems have a limit on how many slots can be filled with damaged fuel cans. A damaged fuel can is generally a stainless steel container that confines damaged SNF and is closed on its end by screened openings. These screened openings allow gaseous and liquid media to escape but minimize the dispersal of gross particulate material. Out of an abundance of caution a few reactors have loaded high burnup fuel into damaged fuel cans. Damaged fuel is not licensed for storage or transport in the U.S., because the regulations for storage and transport do not specify exactly how to classify damaged fuel. Instead the regulations license/certify packages that specify approved contents. Damaged fuel must be included in the approved contents to be a viable option. In many cases damaged SNF is encapsulated in a damaged fuel can to ensure it can confine gross fuel particles, debris, and or damaged assemblies to a known volume within a loaded cask. This damaged fuel can may then be utilized in the same way as an assembly in a storage and transportation design system. Some storage cask systems utilize top and bottom plugs to confine debris in damaged fuel. The most recent domestic documentation on damaged SNF was performed by the U.S. Energy Information Administration (EIA) and used data from U.S. reactors concluding in June 30th 2013 to produce Form GC-859, “Nuclear Fuel Data Survey”. Based on this form there were 136,821 boiling water reactor (BWR) spent nuclear fuel (SNF) assemblies and 104,647 pressurized water reactor (PWR) SNF assemblies for a total of 241,468 SNF assemblies in the U.S. Out of these 241,468 SNF assemblies, 4,521 assemblies were classified as failed. Some assemblies were also disassembled and the fuel rods or pieces of fuel rods were combined together to make a consolidated assembly. A consolidated assembly may include damaged fuel, or it could have been consolidated as part of a demonstration project. The GC-859 data includes 2,550 consolidated assemblies containing between 0 and 264 whole fuel rods. These consolidated assemblies could be placed in single assembly canisters and stored in the spent fuel pool. For dry storage and transportation, a single assembly canister is generally placed in a damaged fuel can. In addition to the consolidated assemblies, 2,391 uncanistered fuel rod pieces exist, which were removed from 494 assemblies.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

2014/2219 Tri-Point Crack Analysis

Friction stir welding (FSW) is a solid state welding process with potential advantages for aerospace and automotive industries dealing with light alloys. Self-reacting friction stir welding (SR-FSW) is one variation of the FSW process being developed at the National Aeronautics and Space Administration (NASA) for use in the fabrication of propellant tanks. Friction plug welding is used to seal the exit hole that remains in a circumferential SR-FSW. The objective of this study was to evaluate the deformation response at the tips of cracks located in the heat affected zone of friction plug welds and to study the fracture behavior of welds with defects in the form of fatigue cracks. The study used existing 2014-T6 to 2219-T87 self-reacting friction stir weld panels with 2219-T87 friction plug welds. Electro-discharge machined (EDM) notches were machined into the heat affected zone of the plug at the plug-to-base metal interface. Samples were then cycled to generate a fatigue crack emanating from the notch. After the fatigue crack reached a pre-defined length, a speckle pattern was applied and the ARAMIS system (a three dimensional imaging correlation system) was used to measure the deformations at the crack tip under a sequence of loads. Testing was conducted at ambient laboratory conditions. Fracture data from the testing was analyzed to evaluate residual strength capability of the panel as a function of flaw size. ARAMIS strain data was evaluated to examine strain and deformation patterns that develop around the crack tip and at the plug/weld interfaces. Four samples were used in this study, with three samples in a post-weld heat treated condition. Three samples contained large diameter plugs (M5) and one sample contained a small diameter plug (M3). Two samples were 4 inches in width and two samples were 8.5 inches in width. All samples failed through the precrack with residual strengths ranging from 37 ksi to 42 ksi.

Horton, Karla Renee↗

Multiphysics Engineering Analysis for an Integrated Design of ITER Diagnostic First Wall and Diagnostic Shield Module Design

ITER diagnostic first walls (DFWs) and diagnostic shield modules (DSMs) inside the port plugs (PPs) are designed to protect diagnostic instrument and components from a harsh plasma environment and provide structural support while allowing for diagnostic access to the plasma. The design of DFWs and DSMs are driven by 1) plasma radiation and nuclear heating during normal operation 2) electromagnetic loads during plasma events and associate component structural responses. A multi-physics engineering analysis protocol for the design has been established at Princeton Plasma Physics Laboratory and it was used for the design of ITER DFWs and DSMs. The analyses were performed to address challenging design issues based on resultant stresses and deflections of the DFW-DSM-PP assembly for the main load cases. ITER Structural Design Criteria for In-Vessel Components (SDC-IC) required for design by analysis and three major issues driving the mechanical design of ITER DFWs are discussed. The general guidelines for the DSM design have been established as a result of design parametric studies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗