Search NASA⌕ Search

SEARCH · Search NASA

Results for “polarization time”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Disk instability and the time-dependent X-ray emission from the intermediate polar GK Persei

The correlation between the disk instability model for the 1981-1989 optical outbursts of the intermediate polar GK Per and the accompanying X-ray emission is examined, and the self-consistency of the combined optical-X-ray model is investigated. Special attention is given to the nature of the transition in the X-ray emission due to the time-dependent accretion rates in the simple column accretion model. The large variation in the efficiency of hard X-ray production is explained.

Yi, Insu↗

A Compact Polarization Imager

A new type of image detector has been designed to analyze the polarization of light simultaneously at all picture elements (pixels) in a scene. The Integrated Dual Imaging Detector (IDID) consists of a polarizing beamsplitter bonded to a custom-designed charge-coupled device with signal-analysis circuitry, all integrated on a silicon chip. The IDID should simplify the design and operation of imaging polarimeters and spectroscopic imagers used, for example, in atmospheric and solar research. Other applications include environmental monitoring and robot vision. Innovations in the IDID include two interleaved 512 x 1024 pixel imaging arrays (one for each polarization plane), large dynamic range (well depth of 10(exp 6) electrons per pixel), simultaneous readout and display of both images at 10(exp 6) pixels per second, and on-chip analog signal processing to produce polarization maps in real time. When used with a lithium niobate Fabry-Perot etalon or other color filter that can encode spectral information as polarization, the IDID can reveal tiny differences between simultaneous images at two wavelengths.

Thompson, Karl E.↗

Time Variations of Cosmic-Ray Helium Isotopes with BESS-Polar I

The Balloon-borne Experiment with a Superconducting Spectrometer (BESS) is configured with a solenoidal superconducting magnet and a suite of precision particle detectors, including time-of-flight hodoscopes based on plastic scintillators, a silica-aerogel Cherenkov detector, and a high resolution tracking system with a central jet-type drift chamber. The charges of incident particles are determined from energy losses in the scintillators. Their magnetic rigidities (momentum/charge) are measured by reconstructing each particle trajectory in the magnetic field, and their velocities are obtained by using the time-of-flight system. Together, these measurements can accurately identify helium isotopes among the incoming cosmic-ray helium nuclei up to energies in the GeV per nucleon region. The BESS-Polar I instrument flew for 8.5 days over Antarctica from December 13th to December 21st, 2004. Its long-duration flight and large geometric acceptance allow the time variations of isotopic fluxes to be studied for the first time. The time variations of helium isotope fluxes are presented here for rigidities from 1.2 to 2.5 GV and results are compared to previously reported proton data and neutron monitor data.

Cosmic-ray flux time variations↗

AVHRR-Based Polar Pathfinder Products: Evaluation, Enhancement and Transition to MODIS

Study of the environment has historically been done with observations and measurements in relatively few local areas. While some of these have been done over long time spans, most have not. The NOAA/NASA Pathfinder project was initiated to complement these data sets with satellite data that can provide information over larger spatial areas and longer time spans. The AVHRR Polar Pathfinder (APR) program was part of this project. The APR was to supply data from the NOAA AVHRR instruments that was consistently generated in a format usable to a wide range of scientific investigators. A grant was obtained from the NASA Research Announcement 97-MTPE-03 to evaluate the APP products, to provide any enhancements, and to compare with products from the new MODIS instrument. There was about a two year overlap between the projects, and this validation effort had several impacts on the APP products. The APP products are derived from the instruments aboard 4 NOAA satellites, NOAA-7, 9, 11, and 14. Initial validation efforts compared the thermal calibrations of these instruments, and differences are found. Calibration has undergone many revisions and techniques have changed since the satellites were launched. The first calibration methods were optimized for global ocean temperatures, as this was one of the primary and important uses of the AVHRR instruments. As the APP program started, newer methods that provided more accurate temperature retrievals over a wider range of temperatures were being developed. The calibration of a wider range of temperatures were necessary because of the extremely low values in the polar regions. These methods were also designed so that calibrated data was also consistent between all the NOAA satellites. These newer calibration methods were then adopted primarily because of the initial finding of this validation effort.

Fowler, Charles↗

Fast polarization changes in mm microwave emission of weak multistructured solar bursts

Circular polarization of weak multistructured solar bursts was measured at mm microwaves with unprecedented sensitivity (0.03 sfu rms) and high time resolution (1ms). It was shown that sudden changes occur in the degree of polarization with time scales of 0.04 to 0.3 s. In most cases the degree of polarization attained maximum values before the maximum flux in both mm microwaves and hard X-rays with time scales of 0.04 to 1.0 s. The timing accuracy in determining the degree of polarization was 40 ms. Physical phenomena are discussed invoking one or a combination of various possible causes for the observed effects. The bursts at mm microwaves were weak compared to the contribution of the preexisting active regions, and therefore the changes in magnetoionic propagation conditions for emerging radiation plays an important role in the observed effects. Composite effects due to more than one polarizing mechanism or more than one polarized spots within the antenna beam are discussed.

Kaufmann, P.↗

The large-area hybrid-optics CLAS12 RICH: First years of data-taking

The CLAS12 deep-inelastic scattering experiment at the upgraded 12 GeV continuous electron beam accelerator facility of Jefferson Lab conjugates luminosity and wide acceptance to study the 3D nucleon structure in the yet poorly explored valence region, and to perform precision measurements in hadron spectroscopy. A large area ring-imaging Cherenkov detector has been designed to achieve the required hadron identification in the momentum range from 3 GeV/c to 8 GeV/c, with the kaon rate about one order of magnitude lower than the rate of pions and protons. The adopted solution comprises aerogel radiator and composite mirrors in a novel hybrid optics design, where either direct or reflected light could be imaged in a high-packed and high-segmented photon detector. The first RICH module was assembled during the second half of 2017 and installed at the beginning of January 2018, in time for the start of the experiment. The second RICH module, planned with the goal to be ready for the beginning of the operation with polarized targets, has been timely built despite the complications caused by the pandemic crisis and successfully installed in June 2022. Finally, the detector performance is here discussed with emphasis on the operation and stability during the data-taking, calibration and alignment procedures, reconstruction and pattern recognition algorithms, and particle identification.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental Demonstration of the Dependence of the First Hyperpolarizability of Donor-Acceptor Substituted Polyenes on the Ground-State Polarization and Bond Length Alternation

The dependence of the product of the first hyperpolarizability, beta, and the ground-state dipole moment, mu, for a series of donor-acceptor polyenes with a large range of ground-state polarization, was measured in a variety of solvents by electric field induced second harmonic generation. The observed behavior of mu times beta as a function of ground-state polarization agrees well with theoretical predictions. In particular, as a function of increasing polarization, mu times beta was found to first increase, peak in a positive sense, decrease, pass through zero, become large and negative, and eventually peak in a negative sense.

hyperpolarizability donor-acceptor substituted pol↗

A modular apparatus for use in high-precision measurements of parity violation in polarized eV neutron transmission

We describe a modular apparatus for use in parity-violation measurements in epithermal neutron–nucleus resonances with high instantaneous neutron fluxes at the Manuel Lujan Jr. Neutron Scattering Center at Los Alamos National Laboratory. This apparatus is designed to conduct high-precision measurements of the parity-odd transmission asymmetry of longitudinally polarized neutrons through targets containing nuclei with p-wave neutron–nucleus resonances in the 0.1–10 eV energy regime and to accommodate a future search for time reversal violation in polarized neutron transmission through polarized nuclear targets. The apparatus consists of an adjustable neutron and gamma collimation system, a 3 He- 4 He ion chamber neutron flux monitor, two identical cryostats for target cooling, an adiabatic eV-neutron spin flipper, a near-unit efficiency 6 Li- 7 Li scintillation detector operated in current mode, a flexible CAEN data acquisition system, and a neutron spin filter based on spin-exchange optical pumping of 3 He gas. We describe the features of the apparatus design devoted to the suppression of systematic errors in parity-odd asymmetry measurements. We describe the configuration of the apparatus used to conduct a precision measurement of parity violation at the 0.7 eV p-wave resonance in 139 La which employs two identical 139 La targets, one to polarize the beam on the p-wave resonance using the weak interaction and one to analyze the polarization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Rotational coherence dominates early-time dynamics and produces long-time revivals in the S 2 state of azulene

Here, the ultrafast dynamics of azulene have been debated for decades, with reported picosecond decay constants variously attributed to intramolecular vibrational redistribution (IVR), internal conversion, or rotational dephasing. Using polarization- and femtosecond time-resolved resonance-enhanced multiphoton ionization spectroscopy with a nanosecond delay window, we disentangle this long-standing inconsistency and show that the early 2–5 ps decay component arises entirely from the rotational dephasing of an excited-state wavepacket. Identical time constants extracted from the decay of the parallel signal and the rise of the perpendicular signal across multiple vibronic origins provide an unambiguous rotational anisotropy signature, eliminating the need for IVR-based interpretations. Extending the measurement window to 1.3 ns reveals well-structured J-type and C-type rotational coherence revivals in S 2 azulene on top of the well-documented fluorescence decay, demonstrating that both the short- and long-time dynamics contain information about the coherent rotational dynamics. These results show that azulene, and by extension polycyclic aromatic hydrocarbons, can sustain structured rotational coherence deep into the nanosecond regime, positioning PAHs as model systems for quantum-coherent wavepacket dynamics and providing a framework for probing coherence, decoherence, and rotational control in electronically rich molecular systems.

Zhan, Jie [University of Georgia, Athens, GA (Unit↗

Mass flux in the ecliptic plane and near the Sun deduced from Doppler scintillation

During the late declining phase of the solar cycle, the tilt of the solar magnetic dipole with respect to the Sun's rotation axis leads to large-scale organization of the solar wind, such that alternating regions of high- and low-speed solar wind are observed in the ecliptic plane. In this paper, we use Doppler scintillation measurements to investigate mass flux of these two types of solar wind in the ecliptic plane and inside 0.3 AU, where in situ measurements have not been possible. To the extent that Doppler scintillation reflects mass flux, we find that mass flux in high-speed streams: (1) is lower (by a factor of approximately 2.2) than the mass flux of the average solar wind in the heliocentric distance range of 0.3-0.5 AU; (2) is lower still (by as much as a factor of about 4) than the mass flux of the slow solar wind associated with the streamer belt; and (3) appears to grow with heliocentric distance. These Doppler scintillation results are consistent with the equator to pole decrease in mass flux observed in earlier spectral broadening measurements, and with trends and differences between high- and low-speed solar wind observed by in situ measurements in the range of 0.3-0.1 AU. The mass flux results suggest that the solar wind flow in high-speed streams is convergent towards the ecliptic near the Sun, becoming less convergent and approaching radial with increasing heliocentric distance beyond 0.3 AU. The variability of mass flux observed within equatorial and polar high-speed streams close to the Sun is strikingly low. This low variability implies that, as Ulysses currently ascends to higher latitudes and spends more time in the south polar high-speed stream after crossing the heliocentric current sheet, it can expect to observe a marked decrease in variations of both mass flux and solar wind speed, a trend that appears to have started already.

Woo, Richard↗

Eddy intrusion of hot plasma into the polar cap and formation of polar-cap arcs

Plasma and electric field signatures of polar cap arcs in their formation region above 5000 km are examined. Signatures for active and for quiet magnetic conditions are presented, both indicating a virtual equivalence of plasma and electric field signatures between the polar and evening discrete arcs, although their optical configurations can be very different. It is proposed that the two types of arcs are indeed the same at active times except that the polar cap arcs occur at multiple convection reversal boundaries of plasmasheet plasmas which intrude into the normal polar cap in the form of multiple cellular eddies. A far-reaching consequence of this hypothesis is the unification of arc formation theory clarifying the distinct roles of arc formation parallel electric fields and of arc configuration and location. Optical and particle data which support this hypothesis are discussed.

Chiu, Y. T.↗

All Sky Search for Gravitational-Wave Bursts in the Second Joint LIGO-Virgo Run

We present results from a search for gravitational-wave bursts in the data collected by the LIGO and Virgo detectors between July 7, 2009 and October 20, 2010: data are analyzed when at least two of the three LIGO-Virgo detectors are in coincident operation, with a total observation time of 207 days. The analysis searches for transients of duration approx. < 1 s over the frequency band 64-5000 Hz, without other assumptions on the signal wa.veform, polarization, direction or occurrence time. All identified events are c.onsistent with the expected accidental background. We set frequentist upper limits on the rate of gravitational-wave bursts by combining this search with the previous LIGOVirgo search on the data collected "between November 2005 and October 2007. The upper limit on the rate of strong gravita.tional-wave bursts at the Earth is 1.3 events per year at 90% confidence. We also present upper limits on source rate density per yea.r and Mpc3 for sample popula.tions of standard-candle sources. As in the previous joint run, typical sensitivities of the search in terms of the root-sum-squared strain amplitude for these waveforms lie in the range approx 5 x 10(exp -22 Hz(exp-1/2) approx 1 X 10(exp -20) Hz(exp -1/2) . The combination of the two joint runs entails the most sensitive all-sky search for generic gravitational-wave bursts and synthesizes the results achieved by the initial generation of interferometric detectors.

Abadie, J.↗

Interplanetary magnetic sector polarity inferred from polar geomagnetic field observations

In order to infer the interplanetary sector polarity from polar geomagnetic field diurnal variations, measurements were carried out at Godhavn and Thule (Denmark) Geomagnetic Observatories. The inferred interplanetary sector polarity was compared with the polarity observed at the same time by Explorer 33 and 35 magnetometers. It is shown that the polarity (toward or away from the sun) of the interplanetary magnetic field can be reliably inferred from observations of the polar cap geomagnetic fields.

Friis-Christensen, E.↗

The solar vector magnetograph of the Okayama Astrophysical Observatory

The vector magnetograph of the Okayama Astrophysical Observatory is fed to the 65 cm solar coude telescope with a 10 m Littrow spectrograph. The polarimeter put at the telescope focus analyzes the incident polarization. Photomultipliers (PMT) at the exit of the spectrograph pick up the modulated light signals and send them to the electronic controller. The controller analyzes frequency and phase of the signal. The analyzer of the polarimeter is a combination of a single wave plate rotating at 40 Hz and a Wallaston prism. Incident linear and circular polarizations are modified at four times and twice the rotation frequency, respectively. Two compensators minimize the instrumental polarization, mainly caused by the two tilt mirrors in the optical path of the telescope. The four photomultipliers placed on the wings of the FeI 5250A line give maps of intensity, longitudinal field and transverse field. The main outputs, maps of intensity, and net linear and circular polarizations in the neighboring continuum are obtained by the other two monitor PMTs.

Makita, M.↗

Model study of multiple polar cap arcs: Occurrence and spacing

A new scenario for the formation of multiple polar cap arcs is proposed based on the results from a time-dependent electrodynamic model of polar cap arcs developed by Zhu et al. (1993). The results suggest that the appearance of multiple polar cap arcs may not be due to multiple structures in the magnetospheric source region, but instead, may primarily be determined by the coupled magnetosphere-ionosphere system in which the ionosphere plays an active role. It was found that with the same magnetospheric driver, a strong ionospheric background convection and an ionospheric background Hall conductance in the range of from 0.5 to 1.5 mho favor the occurrence of multiple polar cap arcs. It was also found that the spacing between individual arcs is highly correlated with the ratio of the enhanced Hall and Pedersen conductances (i.e., the hardness of the primary magnetospheric precipitation), which is allowed to vary in the model runs. A harder precipitation causes a wider spacing. In the modelings, the spacing ranged from about 20 kilometers to about 60 kilometers when the precipitation hardness increased.

Zhu, L.↗

An Integrated Imaging Detector of Polarization and Spectral Content

A new type of image detector has been designed to simultaneously analyze the polarization of light at all picture elements in a scene. The Integrated Dual Imaging Detector (IDID) consists of a polarizing beamsplitter bonded to a charge-coupled device (CCD), with signal-analysis circuitry and analog-to-digital converters, all integrated on a silicon chip. It should be capable of 1:10(exp 4) polarization discrimination. The IDID should simplify the design and operation of imaging polarimeters and spectroscopic imagers used, for example, in atmospheric and solar research. Innovations in the IDID include (1) two interleaved 512 x 1024-pixel imaging arrays (one for each polarization plane); (2) large dynamic range (well depth of 10(exp 6) electrons per pixel); (3) simultaneous readout of both images at 10 million pixels per second each; (4) on-chip analog signal processing to produce polarization maps in real time; (5) on-chip 10-bit A/D conversion. When used with a lithium-niobate Fabry-Perot etalon or other color filter that can encode spectral information as polarization, the IDID can collect and analyze simultaneous images at two wavelengths. Precise photometric analysis of molecular or atomic concentrations in the atmosphere is one suggested application. When used in a solar telescope, the IDID will charge the polarization, which can then be converted to maps of the vector magnetic fields on the solar surface.

Rust, D. M.↗

The Imaging X-Ray Polarimetry Explorer (IXPE): Technical Overview II

The Imaging X-ray Polarimetry Explorer (IXPE) will add polarization to the properties (time, energy, and position) observed in x-ray astronomy. A NASA Astrophysics Small Explorer (SMEX) in partnership with the Italian Space Agency (ASI), IXPE will measure the 2–8-keV polarization of a few dozen sources during the first 2 years following its 2021 launch. The IXPE Observatory includes three identical x-ray telescopes, each comprising a 4-m-focal-length (grazingincidence) mirror module assembly (MMA) and a polarization-sensitive (imaging) detector unit (DU), separated by a deployable optical bench. The Observatory’s Spacecraft provides typical subsystems (mechanical, structural, thermal, power, electrical, telecommunications, etc.), an attitude determination and control subsystem for 3-axis stabilized pointing, and a command and data handling subsystem communicating with the science instrument and the Spacecraft subsystems.

X-ray astronomy↗