Search NASA⌕ Search

SEARCH · Search NASA

Results for “position measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Relative Navigation Strategies for the Magnetopheric Multiscale Mission

This paper evaluates several navigation approaches for the Magnetospheric Multiscale (MMS) mission, which consists of a tetrahedral formation of satellites flying in highly eccentric Earth orbits. For this investigation, inter-satellite separations of approximately 10 kilometers near apogee are used for the first two phases of the MMS mission. Navigation approaches were studied using ground station two-way Doppler measurements, Global Positioning System (GPS) pseudorange measurements, and cross-link range measurements between the members of the formation. An absolute position accuracy of 15 kilometers or better can be achieved with most of the approaches studied, and a relative position accuracy of 100 meters or better can be achieved at apogee in several cases.

Gramling, Cheryl↗

A profile monitor for proton radiography experiments at the Los Alamos Neutron Science Center

The Proton Radiography (pRad) facility at the Los Alamos Neutron Science Center utilizes pulses of protons delivered by the 800 MeV linear accelerator to produce a series of radiographic images to study the dynamic behavior of materials under extreme conditions. Radiographs taken with an empty field of view, or beam pictures, are used to normalize transmission. However, because the center of the proton beam shifts between pulses, an in situ method for measuring beam position is required to normalize images for beam movement to perform absolute radiography. The beam profile monitor described here uses an array of scintillating fibers positioned in the beam path to produce light proportional to beam intensity across the beam cross section. This light is detected using fast photodiodes and a digital oscilloscope, providing a response time of several nanoseconds—suitable for measuring the 50-ns proton pulses used in pRad. The profile monitor achieves a measured position precision of 40 μm and an intensity precision of 0.7%, allowing for beam movement corrections to be applied to images, thereby improving data accuracy and image quality.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of Two Computational Techniques of Calculating Multipath Using Global Positioning System Carrier Phase Measurements

Two computational techniques are used to calculate differential phase errors on Global Positioning System (GPS) carrier war phase measurements due to certain multipath-producing objects. The two computational techniques are a rigorous computati electromagnetics technique called Geometric Theory of Diffraction (GTD) and the other is a simple ray tracing method. The GTD technique has been used successfully to predict microwave propagation characteristics by taking into account the dominant multipath components due to reflections and diffractions from scattering structures. The ray tracing technique only solves for reflected signals. The results from the two techniques are compared to GPS differential carrier phase ns taken on the ground using a GPS receiver in the presence of typical International Space Station (ISS) interference structures. The calculations produced using the GTD code compared to the measured results better than the ray tracing technique. The agreement was good, demonstrating that the phase errors due to multipath can be modeled and characterized using the GTD technique and characterized to a lesser fidelity using the DECAT technique. However, some discrepancies were observed. Most of the discrepancies occurred at lower devations and were either due to phase center deviations of the antenna, the background multipath environment, or the receiver itself. Selected measured and predicted differential carrier phase error results are presented and compared. Results indicate that reflections and diffractions caused by the multipath producers, located near the GPS antennas, can produce phase shifts of greater than 10 mm, and as high as 95 mm. It should be noted tl the field test configuration was meant to simulate typical ISS structures, but the two environments are not identical. The GZ and DECAT techniques have been used to calculate phase errors due to multipath o the ISS configuration to quantify the expected attitude determination errors.

Gomez, Susan F.↗

Rapidly-Indexing Incremental-Angle Encoder

Optoelectronic system measures relative angular position of shaft or other device to be turned, also measures absolute angular position after device turned through small angle. Relative angular position measured with fine resolution by optoelectronically counting finely- and uniformly-spaced light and dark areas on encoder disk as disk turns past position-sensing device. Also includes track containing coarsely- and nonuniformly-spaced light and dark areas, angular widths varying in proportion to absolute angular position. This second track provides gating and indexing signal.

Christon, Philip R.↗

Position-And-Direction Sensor For Light Beams

Optoelectronic sensor measures both position and direction of incidence of laser beam or other narrow beam of light. New sensor part of robotic welding system in which laser beam reflected from pool of molten metal and monitored by lateral-position sensor. To provide unambiguous measurement of both lateral position and direction of incident beam, sensor includes two position-sensitive photodetectors or linear arrays of photodetectors.

Smith, Matthew A.↗

SHAPES - Spatial, high-accuracy, position-encoding sensor

Future space systems will require control sensors capable of real-time measurements of position coordinates of many structural locations. Applications for such a sensor include figure and vibration control, rendezvous and docking, and structure assembly verification. The paper discusses an experimental study of SHAPES (spatial, high-accuracy, position-encoding sensor), a 3D position sensor that provides range and two angular positions of laser-illuminated retroreflector targets that mark the locations to be measured. Simultaneous range measurements to multiple targets by a time-of-flight corelation of short laser pulses are made with a CCD-equipped streak tube. Angular positions are measured with a CCD camera. Position measurements of 24 targets with sub-millimeter range accuracy at a 10 Hz update rate have been demonstrated.

Nerheim, Noble M.↗

Simultaneous Measurements of Noncommuting Observables: Positive Transformations and Instrumental Lie Groups

We formulate a general program for describing and analyzing continuous, differential weak, simultaneous measurements of noncommuting observables, which focuses on describing the measuring instrument autonomously, without states. The Kraus operators of such measuring processes are time-ordered products of fundamental differential positive transformations, which generate nonunitary transformation groups that we call instrumental Lie groups. The temporal evolution of the instrument is equivalent to the diffusion of a Kraus-operator distribution function, defined relative to the invariant measure of the instrumental Lie group. This diffusion can be analyzed using Wiener path integration, stochastic differential equations, or a Fokker-Planck-Kolmogorov equation. This way of considering instrument evolution we call the Instrument Manifold Program. We relate the Instrument Manifold Program to state-based stochastic master equations. We then explain how the Instrument Manifold Program can be used to describe instrument evolution in terms of a universal cover that we call the universal instrumental Lie group, which is independent not just of states, but also of Hilbert space. The universal instrument is generically infinite dimensional, in which case the instrument’s evolution is chaotic. Special simultaneous measurements have a finite-dimensional universal instrument, in which case the instrument is considered principal, and it can be analyzed within the differential geometry of the universal instrumental Lie group. Principal instruments belong at the foundation of quantum mechanics. We consider the three most fundamental examples: measurement of a single observable, position and momentum, and the three components of angular momentum. As these measurements are performed continuously, they converge to strong simultaneous measurements. For a single observable, this results in the standard decay of coherence between inequivalent irreducible representations. For the latter two cases, it leads to a collapse within each irreducible representation onto the classical or spherical phase space, with the phase space located at the boundary of these instrumental Lie groups.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The detection of dust storms over land and water with satellite visible and infrared measurements

The position of a large area of dust was successfully located over the Sahara Desert and off the west coast of Africa with infrared measurements from the Temperature Humidity Infrared Radiometer (THIR) and visible information from the Image Dissector Camera System (IDCS) on Nimbus 4 between 20 and 25 April 1970. Over land, near midday, the dust areas were associated with lower equivalent blackbody temperatures (TBB's) than in the surrounding areas due to the mixing of the dust with the cooler air just above the surface. Near midnight dust areas appeared to be located where the TBB's were higher than the surrounding regions. The TBB contrast was insufficient for dust detection over the ocean, but the contrast in the visible was great enough to track the movement of the dust for several days off the African west coast. Measurements from the THIR 6.5-7.2 micron channel were useful for detecting the presence of cirrus clouds which could have caused a misinterpretation of the 10.5-12.5 micron TBB's.

Shenk, W. E.↗

Comparison of melt-solid interface position by radiography and temperature measurement in a vertical Bridgman furnace

The melt-solid interface position was measured during the Bridgman growth of germanium by both temperature profiling and by X-ray imaging. The temperature field of the ampoule, growth material and measurement thermocouples was analyzed by means of numerical analysis. It is shown that both the temperature shift and the discontinuity in temperature gradient is a function of the imposed thermal field and the thermal properties of the thermocouples.

Hubert, James A.↗

GPS Measurement Of Attitude

Signals transmitted by satellites of Global Positioning System (GPS) measure orientation of baseline on ship, aircraft, or other vehicle with accuracy. Two GPS antennas and receivers placed at well separated points on platform. Receivers measure positions of ends of baseline as functions of time. Output processor computes vector difference between two positions and determines orientation of baseline. Combined with conventional GPS data, orientation data allows more precise navigation and mapping and enhances calculations related to performance and control of vehicle.

Dinardo, S. J.↗

A feasibility study for measuring stratospheric turbulence using metrac positioning system

The feasibility of obtaining measurements of Lagrangian turbulence at stratospheric altitudes is demonstrated by using the METRAC System to track constant-level balloons. The basis for current estimates of diffusion coefficients are reviewed and it is pointed out that insufficient data is available upon which to base reliable estimates of vertical diffusion coefficients. It is concluded that diffusion coefficients could be directly obtained from Lagrangian turbulence measurements. The METRAC balloon tracking system is shown to possess the necessary precision in order to resolve the response of constant-level balloons to turbulence at stratospheric altitudes. A small sample of data recorded from a tropospheric tetroon flight tracked by the METRAC System is analyzed to obtain estimates of small-scale three-dimensional diffusion coefficients. It is recommended that this technique be employed to establish a climatology of diffusion coefficients and to ascertain the variation of these coefficients with altitude, season, and latitude.

Gage, K. S.↗

Magnetic environment of hydrogen in Fe from muon precession measurements

Polarized positive muon radiation was stopped in an ellipsoidal iron target and its precession was observed in a transverse magnetic field. Results indicate that the conduction electron polarization in the 77 K-Fe Curie point region is less than expected, and that the relaxation time of the muon polarization is dominated by the static inhomogeneity to 900 K, at which point magnetization fluctuations become important.

Heiman, N.↗

Cardiovascular regulation in microgravity

The human cardiovascular adaptation to microgravity was investigated in the framework of the German Spacelab D2 mission. Preflight and postflight studies were performed to examine the relationship between disuse atrophy and the function of cardiac and skeletal muscles. Special attention was given to fluid load responses and postflight orthostatic hypotension. The preflight measurements were obtained, in supine and sitting positions. These measurements, carried out in the four D2 crew members, were performed six and nine months before flight and on mission day number five. The results obtained on the male crew showed that the stroke volume data from microgravity are virtually identical to preflight measurements in the sitting position.

C. G. Blomqvist↗

Exposure to a Rotating Virtual Environment During Treadmill Locomotion Causes Adaptation in Heading Direction

The goal of the present study was to investigate the adaptive effects of variation in the direction of optic flow, experienced during linear treadmill walking, on modifying locomotor trajectory. Subjects (n = 30) walked on a motorized linear treadmill at 4.0 kilometers per hour for 24 minutes while viewing the interior of a 3D virtual scene projected onto a screen 1.5 in in front of them. The virtual scene depicted constant self-motion equivalent to either 1) walking around the perimeter of a room to one s left (Rotating Room group) 2) walking down the center of a hallway (Infinite Hallway group). The scene was static for the first 4 minutes, and then constant rate self-motion was simulated for the remaining 20 minutes. Before and after the treadmill locomotion adaptation period, subjects performed five stepping trials where in each trial they marched in place to the beat of a metronome at 90 steps/min while blindfolded in a quiet room. The subject's final heading direction (deg), final X (for-aft, cm) and final Y (medio-lateral, cm) positions were measured for each trial. During the treadmill locomotion adaptation period subject's 3D torso position was measured. We found that subjects in the Rotating Room group as compared to the Infinite Hallway group: 1) showed significantly greater deviation during post exposure testing in the heading direction and Y position opposite to the direction of optic flow experienced during treadmill walking 2) showed a significant monotonically increasing torso yaw angular rotation bias in the direction of optic flow during the treadmill adaptation exposure period. Subjects in both groups showed greater forward translation (in the +X direction) during the post treadmill stepping task that differed significantly from their pre exposure performance. Subjects in both groups reported no perceptual deviation in position during the stepping tasks. We infer that viewing simulated rotary self-motion during treadmill locomotion causes adaptive modification of sensory-motor integration in the control of position and trajectory during locomotion which functionally reflects adaptive changes in the integration of visual, vestibular, and proprioceptive cues. Such an adaptation in the control of position and heading direction during locomotion due to the congruence of sensory information demonstrates the potential for adaptive transfer between sensorimotor systems and suggests a common neural site for the processing and self-motion perception and concurrent adaptation in motor output. This will result in lack of subjects perception of deviation of position and trajectory during the post treadmill step test while blind folded.

Ruttley, T↗

Exposure to a Rotating Virtual Environment During Treadmill Locomotion Causes Adaptation in Heading Direction

The goal of the present study was to investigate the adaptive effects of variation in the direction of optic flow, experienced during linear treadmill walking, on modifying locomotor trajectory. Subjects (n = 30) walked on a motorized linear treadmill at 4.0 km/h for 24 minutes while viewing the interior of a 3D virtual scene projected onto a screen 1.5 m in front of them. The virtual scene depicted constant self-motion equivalent to either 1) walking around the perimeter of a room to one s left (Rotating Room group) 2) walking down the center of a hallway (Infinite Hallway group). The scene was static for the first 4 minutes, and then constant rate self-motion was simulated for the remaining 20 minutes. Before and after the treadmill locomotion adaptation period, subjects performed five stepping trials where in each trial they marched in place to the beat of a metronome at 90 steps/min while blindfolded in a quiet room. The subject s final heading direction (deg), final X (for-aft, cm) and final Y (medio-lateral, cm) positions were measured for each trial. During the treadmill locomotion adaptation period subject s 3D torso position was measured. We found that subjects in the Rotating Room group as compared to the Infinite Hallway group: 1) showed significantly greater deviation during post exposure testing in the heading direction and Y position opposite to the direction of optic flow experienced during treadmill walking 2) showed a significant monotonically increasing torso yaw angular rotation bias in the direction of optic flow during the treadmill adaptation exposure period. Subjects in both groups showed greater forward translation (in the +X direction) during the post treadmill stepping task that differed significantly from their pre exposure performance. Subjects in both groups reported no perceptual deviation in position during the stepping tasks. We infer that 3 viewing simulated rotary self-motion during treadmill locomotion causes adaptive modification of sensory-motor integration in the control of position and trajectory during locomotion which functionally reflects adaptive changes in the integration of visual, vestibular, and proprioceptive cues. Such an adaptation in the control of position and heading direction during locomotion due to the congruence of sensory information demonstrates the potential for adaptive transfer between sensorimotor systems and suggests a common neural site for the processing and self-motion perception and concurrent adaptation in motor output. This will result in lack of subjects perception of deviation of position and trajectory during the post treadmill step test while blind folded.

Mulavara, A. P.↗

Slot-Height Measuring System

Height displayed as function of position. Slot-depth measuring system uses spring-loaded transducer to measure slot depth and wheel-driven rotary optical encoder to measure position along slot. An x-y recorder plots depth vs. position.

Clarke, Alan D.↗