At least 325 records · Page 18

pnnl/oedisi_dopf

OpenEDI - System Integration (OEDI-SI) - PNNL Distributed Optimal Power Flow (DOPF)

Slay, Tylor↗

On Anomaly Detection for Transactive Energy Systems with Competitive Market

Two anomaly-detection criteria are proposed for transactive energy systems with competitive markets. Participants of transactive energy systems seek an optimal power allocation through hybrid economic-control methods to facilitate the integration of various types of distributed energy resources to power distribution systems. In transactive energy systems, every participant is assumed to be a rational entity, and consumers have diminishing marginal utility and suppliers have increasing marginal cost. With the first proposed anomaly-detection criterion, the monotonicity of marginal cost and marginal utility are examined. The impact of line flow constraints is also taken into consideration. Then, the second anomaly-detection criterion is proposed for TESs with marginal cost and marginal utility which change faster than a certain rate. The second criterion is more accurate than the first one for TES with marginal cost and marginal utility which change faster than a certain rate, but it requires the knowledge of that rate. Neither criteria requires more data than those necessary to find the optimal power allocation and the market-clear price in a transactive energy system. Therefore, the proposed criteria do not disclose any more data than necessary. As the monotonicity of marginal cost and marginal utility in a TES with competitive markets results in convex objective functions in an optimization problem and strongly convex ones when marginal cost and marginal utility changes faster than a certain rate, the two detection criteria are also applicable to anomaly detection of general convex optimization problems. Simulations are carried out to show the efficacy of the proposed criteria to detect anomalies caused by cyberattacks.

Wang, Peng↗

Conservation Voltage Reduction (CVR) via Two-Timescale Control in Unbalanced Power Distribution Systems

Voltage control devices are employed in power distribution systems to reduce the power consumption by operating the system closer to the lower acceptable voltage limits; this technique is called conservation voltage reduction (CVR). The different modes of operation for system’s legacy devices (with binary control) and new devices (e.g. smart inverters with continuous control) coupled with variable photovoltaic (PV) generation results in voltage fluctuations which makes it challenging to achieve CVR objective. This paper presents a two-timescale control of feeder’s voltage control devices to achieve CVR that includes (1)a centralized controller operating in a slower time-scale to coordinate voltage control devices across the feeder and (2) local controllers operating in a faster timescale to mitigate voltage fluctuations due to PV variability. The centralized controller utilizes a three-phase optimal power flow model to obtain the decision variables for both legacy devices and smart inverters. The local controllers operate smart inverters to minimize voltage fluctuations and restore nodal voltages to their reference values by adjusting the reactive power support. The proposed approach is validated using the IEEE-123 bus (medium-size) and R3-12.47-2 (large-size) feeders. It is demonstrated that the proposed approach is effective in achieving the CVR objective for unbalanced distribution systems.

optimal control, distributed generation, fluctuati↗

Personal Fuel Economy in Conventional and Hybrid Electric Vehicles: Integrating Driving Cycle Predictions with Power Distribution Optimization

Improving fuel efficiency and lowering emissions are key societal goals. Standard driving cycles, pre-designed by the US Environmental Protection Agency (EPA), have long been used to estimate vehicle fuel efficiency in laboratory controlled conditions. They have also been used to test and tune different energy management strategies for hybrid electric vehicles (HEVs). This study uses standard driving cycles as a base for comparison, while aiming to develop fuel efficiency estimates based on personalized driving cycles that can inform consumers’ vehicle purchase and use decisions. To do this, we extracted driving cycles for conventional vehicles and HEVs from a large-scale survey that contains real-world GPS-based driving records. Next, the driving cycles were assigned to one of three categories: aggressive, normal, or calm. Then the driving cycles were used along with a driver-vehicle simulation that captures driver decisions (vehicle speed during a trip), powertrain, and vehicle dynamics to estimate personal fuel efficiency for conventional vehicles and HEVs. To optimize personal fuel efficiency estimates, the Equivalent Consumption Minimization Strategy (ECMS) is applied. Depending on the driving style (aggressive, normal, or calm) and the driving scenario (city or highway driving), conventional vehicle fuel consumption can vary widely compared with standard EPA driving cycles. Specifically, conventional vehicle fuel efficiency was 13% lower in calm city driving, but almost 34% higher for aggressive highway driving compared with standard EPA driving cycles. Interestingly, when a driving cycle is predicted based on application of case-based reasoning and used to tune the power distribution in HEVs, their fuel consumption can improve by up to 12% in city driving. Implications and limitations of the findings are discussed in the paper.

Liu, Jun↗

OPFLearn.jl [SWR-21-109]

OPFLearn.jl is a Julia package for creating datasets for machine learning approaches to solving AC optimal power flow (AC OPF). It was developed to provide researchers with a standardized way to efficiently create AC OPF datasets that are representative of more of the AC OPF feasible load space compared to typical dataset creation methods. The OPFLearn dataset creation method uses a relaxed AC OPF formulation to reduce the volume of the unclassified input space throughout the dataset creation process. Over time this input space tightens around the relaxed AC OPF feasible region to increase the percentage of feasible load profiles found while uniformly sampling the input space. Load samples are processed using AC OPF formulations from PowerModels.jl. More information on the dataset creation method can be found in our publication, "OPF-Learn: An Open-Source Framework for Creating Representative AC Optimal Power Flow Datasets". To use OPFLearn.jl a PowerModels network data dictionary is required (can be loaded from Matpower ".m" files) to define the network the dataset is being created for.

Joswig-Jones, Trager↗

OPFLearn.jl v0.1.2 5/18/2023 [SWR-21-109]

OPFLearn.jl is a Julia package for creating datasets for machine learning approaches to solving AC optimal power flow (AC OPF). It was developed to provide researchers with a standardized way to efficiently create AC OPF datasets that are representative of more of the AC OPF feasible load space compared to typical dataset creation methods. The OPFLearn dataset creation method uses a relaxed AC OPF formulation to reduce the volume of the unclassified input space throughout the dataset creation process. Over time this input space tightens around the relaxed AC OPF feasible region to increase the percentage of feasible load profiles found while uniformly sampling the input space. Load samples are processed using AC OPF formulations from PowerModels.jl. More information on the dataset creation method can be found in our publication, "OPF-Learn: An Open-Source Framework for Creating Representative AC Optimal Power Flow Datasets". To use OPFLearn.jl a PowerModels network data dictionary is required (can be loaded from Matpower ".m" files) to define the network the dataset is being created for.

Joswig-Jones, Trager↗

Recovery Act: A Measurement -- Management Technology for Improving Energy Efficiency in Data Centers and Telecommunication Facilities (Final Technical Report)

Data center (DC) electricity use is increasing at an annual rate of over 20% and presents a concern for the Information Technology (IT) industry, governments, and the society. A large fraction of the energy use is consumed by the compressor cooling to maintain the recommended operating conditions for IT equipment. The most common way to improve the DC efficiency is achieved by optimally provisioning the cooling power to match the global heat dissipation in the DC. However, at a more granular level, the large range of heat densities of today's IT equipment makes the task of provisioning cooling power optimized to the level of individual computer room air conditioning (CRAC) units much more challenging. Distributed sensing within a DC enables the development of new strategies to improve energy efficiency, such as hot spot elimination through targeted cooling, matching power consumption at rack level with workload schedule, and minimizing power losses. The scope of Measurement and Management Technologies (MMT) is to develop a software tool and the underlying sensing technology to provide critical decision support and control for DC and telecommunication facilities (TF) operations. A key aspect of MMT technology is integration of modeling tools to understand how changes in one operational parameter affect the overall DC response. It is demonstrated that reduced ordered models for DC can generate, in less than 2 seconds computational time, a three dimensional thermal model in a 50 kft 2 DC. This rapid modeling enables real time visualization of the DC conditions and enables "0what if" scenarios simulations to characterize response to "disturbances". One such example is thermal zone modeling that matches the cooling power to the heat generated at a local level by identifying DC zones cooled by a specific CRAC. Turning off a CRAC unit can be simulated to understand how the other CRAC utilization changes and how server temperature responds. Several new sensing technologies were added to the existing MMT platform: (1) air contamination (corrosion) sensors, (2) power monitoring, and (3) a wireless environmental sensing network. All three technologies are built on cost effective sensing solutions that increase the density of sensing points and enable high resolution mapping of DCs. The wireless sensing solution enables Air Conditioning Unit (ACU) control while the corrosion sensor enables air side economization and can quantify the risk of IT equipment failure due to air contamination. Validation data for six test sites demonstrate that leveraging MMT energy efficiency solutions combined with industry best practices results in an average of 20% reduction in cooling energy, without major infrastructure upgrades. As an illustration of the unique MMT capabilities, a data center infrastructure efficiency (DCIE) of 87% (industry best operation) was achieved. The technology is commercialized through IBM System and Technology Lab Services that offers MMT as a solution to improve DC energy efficiency. Estimation indicates that deploying MMT in existing DCs can results in an 8 billion kWh savings and projection indicates that constant adoption of MMT can results in obtainable savings of 44 billion kWh in 2035. Negotiations are under way with business partners to commercialize/license the ACU control technology and the new sensor solutions (corrosion and power sensing) to enable third party vendors and developers to leverage the energy efficiency solutions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Constraints on OPF Surrogates for Learning Stable Local Volt/Var Controllers

We consider the problem of learning local Volt/Var controllers in distribution grids (DGs). Our approach starts from learning separable surrogates that take both local voltages and reactive powers as arguments and predict the reactive power setpoints that approximate optimal power flow (OPF) solutions. We propose an incremental control algorithm and identify two different sets of slope conditions on the local surrogates such that the network is collectively steered toward desired configurations asymptotically. Our results reveal the trade-offs between each set of conditions, with coupled voltage-power slope constraints allowing an arbitrary shape of surrogate functions but risking limitations on exploiting generation capabilities, and reactive power slope constraints taking full advantage of generation capabilities but constraining the shape of surrogate functions. AC power flow simulations on the IEEE 37-bus feeder illustrate their guaranteed stability properties and respective advantages in two DG scenarios.

asymptotic stability↗

MIDAS-DC-AC Tool: Fully Automating the Acquisition of AC Power Flow Solution (MIDAS-DC2AC)

MIDAS DC2AC is an automated tool for achieving a converged AC power flow solution from any dispatch, e.g., determined using DC power flow model based optimal power flow. The entire process is free of human interference. It is usually encountered in practice that, even with a DC power flow solution, acquiring the solved AC power flow solution, if exists, sometimes could be a challenging task, especially during the planning stage. It is also difficult to distinguish the unsolvable cases from diverging iterations. Manual adjustments to approach the desired power flow condition has been largely relied on in the past using lots of engineering heuristics. This tool provides a systematic way to first achieve a solvable AC power flow case by modifying the power flow condition, and then try to track the AC power flow solution while gradually removing the adopted changes. If all adopted changes can be completely removed, then the original AC power flow solution is obtained. Otherwise, insights for actionable controls are derived to help operation and planning. Currently, this tool has been implemented in Python using SIEMENS PTI PSS/E as power flow solver, where only adjusting generator terminal voltage set point is considered as an available means to try to turn an unsolved power flow to a solved one. In future, more means should be considered, including the operation of tap-changing transformers, switched shunts and redispatch of active power.

Tan, Jin↗