Search NASA⌕ Search

SEARCH · Search NASA

Results for “precision”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Alignment of Short Reads: A Crucial Step for Application of Next-Generation Sequencing Data in Precision Medicine

Precision medicine or personalized medicine has been proposed as a modernized and promising medical strategy. Genetic variants of patients are the key information for implementation of precision medicine. Next-generation sequencing (NGS) is an emerging technology for deciphering genetic variants. Alignment of raw reads to a reference genome is one of the key steps in NGS data analysis. Many algorithms have been developed for alignment of short read sequences since 2008. Users have to make a decision on which alignment algorithm to use in their studies. Selection of the right alignment algorithm determines not only the alignment algorithm but also the set of suitable parameters to be used by the algorithm. Understanding these algorithms helps in selecting the appropriate alignment algorithm for different applications in precision medicine. Here, we review current available algorithms and their major strategies such as seed-and-extend and q-gram filter. We also discuss the challenges in current alignment algorithms, including alignment in multiple repeated regions, long reads alignment and alignment facilitated with known genetic variants.

59 BASIC BIOLOGICAL SCIENCES↗

Testing the Deployment Repeatability of a Precision Deployable Boom Prototype for the Proposed SWOT Karin Instrument

NASA's proposed Surface Water Ocean Topography (SWOT) mission, scheduled to launch in 2020, would provide critical information about Earth's oceans, ocean circulation, fresh water storage, and river discharge. The mission concept calls for a dual-antenna Ka-band radar interferometer instrument, known as KaRIn, that would map the height of water globally along two 50 km wide swaths. The KaRIn antennas, which would be separated by 10 meters on either side of the spacecraft, would need to be precisely deployable in order to meet demanding pointing requirements. Consequently, an effort was undertaken to design build and prototype a precision deployable Mast for the KaRIn instrument. Each mast was 4.5-m long with a required dilitation stability of 2.5 microns over 3 minutes. It required a minimum first mode of 7 Hz. Deployment repeatability was less than +/- 7 arcsec in all three rotation directions. Overall mass could not exceed 41.5 Kg including any actuators and thermal blanketing. This set of requirements meant the boom had to be three times lighter and two orders of magnitude more precise than the existing state of the art for deployable booms.

boom↗

NASA and Blue Origin Collaborative Assessment of Precision Landing Algorithms and Computing

NASA’s Safe and Precise Landing Integrated Capabilities Evolution (SPLICE) project is developing sensor, algorithm, and compute technologies for precision landing and hazard avoidance. These technologies are being tested as an integrated Precision Landing and Hazard Avoidance (PL&HA) system on Blue Origin’s New Shephard suborbital vehicle. A key goal for the computing element of this technology development is to characterize the performance of the SPLICE software workloads on the project’s Descent and Landing Computer (DLC). The DLC is a multi-core processor designed as a surrogate for NASA’s High-Performance Space Computer (HPSC). Measurements of the SPLICE workload performance on the DLC provides NASA insight on how PL&HA capabilities will perform on the HPSC, and guidance on how the SPLICE algorithms can be implemented to best utilize the DLC platform. This insight can also be used to derive requirements to guide trade studies on candidate computing architectures, for use on platforms like Blue Moon. NASA and Blue Origin are collaborating under an agreement to pursue this mutual benefit. Performance metrics collected are based on measurement of common compute resources such as percentage used of memory bandwidth, I/O utilization, interrupt latency, and kernel vs. user space code residency. Where possible existing performance counters and metrics that are part of the operating system kernel are used. As the design has a significant FPGA component, performance counters are identified and instantiated in the fabric to measure DMA performance and interface metrics. Collection of metrics is performed on the DLC with a representative workload that simulates a full landing cycle of the Blue Origin New Shepard vehicle. Consideration is given to the other compute implementations and whether they can run SPLICE algorithms at the same rate and with the same latency as the DLC. One option being considered is the use of a RISC-V soft core instantiated in a radiation resilient FPGA fabric such as the Xilinx KU60. Select algorithms from the SPLICE code will be run for comparison with the DLC. This paper describes how the DLC is instrumented to collect performance measurements of the SPLICE workloads, preliminary results from these measurements, and their implications on SPLICE algorithm implementation. The results of experimentation to derive candidate requirements for architecture trades on a PL&HA computing system are also presented.

computer performance↗

Improving Efficacy and Safety of Pharmacological Treatment Through Precision Health and Pharmacogenomics

INTRODUCTION: Future spaceflight will require increased crew medical autonomy as exploration class missions expand in duration and distance from Earth, especially for Mars missions. As mission duration increases, it will be essential to have appropriate amounts of effective medication to ensure the maintenance of crew health and performance. Conversely, mass and volume constraints will become more severe as future spaceflight expands beyond low Earth orbit, where resupply is difficult or becomes impossible. These constraints thus convey an urgency to tailor medications for individual crewmembers and further examine appropriate dosing regimens. BACKGROUND: Precision Health is an exciting area of medicine focused on maintaining an individual’s health and performance through in-depth understanding of an individual’s unique clinical and environmental history, genetic makeup, and molecular profiles. This approach can be adapted to better predict, monitor, and address physiological responses to the spaceflight environment. A subset of this field is pharmacogenomics (PGX), the study of how the expressed genome impacts drug responses with the goal of prescribing the right dose of the right drug at the right time. Specifically, PGX testing provides valuable information on an individual’s precise allelic variations to guide physicians in making informed decisions on drug choice and dosing to avoid adverse events and maximize efficacy. The study goal was to identify which current space pharmacy drugs could be evaluated using PGX testing and to understand the potential impact on the health and wellness of the astronaut population. Additionally, we sought to evaluate clinically available FDA-approved PGX testing solutions to better understand its applicability. METHODS: A complete list of drugs on the ISS was analyzed for risk and likelihood of drug failure and PGX actionability. This analysis encompassed both astronauts’ personal medications, including supplements and over the counter drugs (n=151) contained in the ISS medical accessory kit (IMAK), and ISS MedKit formulary medications (n=95). Duplicate medications and different formulations were removed, which resulted in a total of 157 drugs used in the subsequent analysis. A 5x5 risk assessment table was produced by examining the likelihood of drug failure compared to the consequence of drug failure (LxC). Likelihood of individual drug failure was defined by whether existing processes are sufficient to prevent ineffective treatment or impactful side effect events, as ranked from 1 (very low, can easily be prevented) to 5 (very high, cannot be prevented) during a Mars mission. In contrast, the consequence of drug failure was defined by impact to safety, schedule, cost, or technical criteria and ranked from 1 (very low) to 5 (very high). An assessment of PGX reference laboratories is currently underway to evaluate sample requirements, benefit analysis (cost vs. utility of allele variant analysis), relevance to inflight medication usage, quality of reporting in enabling clinical application, and ease of integration into electronic medical records. RESULTS: Risk assessments (LxC 5x5 table) indicated 128 medications were in the green zone where risk is acceptable, with the remaining 29 of the medications in the yellow or red zone driven predominantly due to drug failure or safety concerns. We found that current PGX testing results could impact 21% of the total medications in the ISS MedKit and IMAK; of these, 9 medications currently have direct clinically actionable guidance available. Results of the clinical PGX solution evaluations as related to these medications will be presented. CONCLUSION: PGX testing has demonstrated clear benefits in terrestrial medicine and clinical environments for the selection of proper medications, avoiding adverse drug reactions, and maximizing drug efficacy. We propose that similar benefits would be bestowed on the astronaut and commercial spaceflight passenger population by performing preemptive preflight PGX testing to reduce risk of mission failure due to ineffective or toxic medications, improve drug efficacy, and further open the door to countermeasure research. For example, PGX results could allow tailoring of specific medications at optimal doses more precisely to each individual astronaut, particularly in areas of space motion sickness, sleep aids, and analgesics. An additional benefit is that PGX results could provide information for better planning of the components of a space pharmacy for deep space missions to be more effective and efficient in the utilization of limited pharmaceutical resources. Finally, while PGX testing of the astronaut corps is not currently conducted, this approach could provide immediate impact in support of mission success by reducing risks, optimizing astronaut performance, and providing valuable insights into long-term astronaut health. Such advancements in clinical decision making are important next steps in building dynamic individual risk profiles for astronauts, increasing selection of the best treatment choice, and providing tailored countermeasures for individual crewmembers.

Pharmacogenomics↗

DPOD2020: A DORIS Extension of the ITRF2020 for Precise Orbit Determination

As one of the tracking systems used to determine orbits of the altimeter mission satellites (such as TOPEX/Poseidon, Envisat, Jason-1/-2/-3, CryoSat-2, Saral/Altika, Sentinel-3A/-3B, HY-2A/C/D, Jason-CS/Sentinel-6A, SWOT), DORIS (Doppler Orbitography Radiopositionning Integrated by Satellite) allows to determine positions and velocities of tracking stations that define a stable reference for the estimation of the precise orbits and thus are fundamental for the quality of the altimeter data and derived mean sea level products. Due to the time evolution of the DORIS ground network, some stations included in the 2020 realization of the International Terrestrial Reference Frame (ITRF2020) have been decommissioned and since 2021.0 a few new stations were added to the tracking network. Therefore, to satisfy operational requirements for POD (Precise Orbit Determination) and routine delivery of geodetic products, the International DORIS Service (IDS) regularly updates the DPOD (DORIS terrestrial reference frame for Precise Orbit Determination). The DPOD solutions include mean positions and velocities of all the DORIS stations since 1993.0 derived from the stacking of the latest IDS weekly combined series aligned to the current ITRF. In this paper, we first present the stacking process of the DPOD2020 version 1.0. Then, we address the validation procedure of the DPO2020 including comparison with ITRF2020 and POD tests. For eighty percent of all the time segments of all the DORIS stations, the station position differences between DPOD2020 version 1.0 and ITRF2020 are smaller than ten millimeters. The major position differences between these two solutions are associated with the DORIS sites either localized in the South Atlantic Anomaly region or with time spans smaller than one year. Compared to DPOD2014, the DPOD2020 shows reduction of the main statistics of the DORIS-to-DORIS tie residuals (differences between the estimated and measured ties). The POD tests showed similar results for DPOD2020 and DPOD2014 for most of the altimetric satellites (TOPEX/Poseidon, Jason-1, CryoSat-2, Jason-3). In addition, we observed better POD results with DPOD2020 for the latest altimetric satellite Sentinel-3A as well as a slight degradation for Jason-2. That degradation was fully explained by slightly worst results for the stations localized in the South Atlantic Anomaly region.

DORIS↗

Mixed-Precision Spectral Deferred Correction: Preprint

Convergence of spectral deferred correction (SDC), where low-order time integration methods are used to construct higher-order methods through iterative refinement, can be accelerated in terms of computational effort by using mixed-precision methods. Using ideas from multi-level SDC (in turn based on FAS multigrid ideas), some of the SDC correction sweeps can use function values computed in reduced precision without adversely impacting the accuracy of the final solution. This is particularly beneficial for the performance of combustion solvers such as S3D [6] which require double precision accuracy but are performance limited by the cost of data motion.

97 MATHEMATICS AND COMPUTING↗

The Atomic Drill Bit: Precision Controlled Atomic Fabrication of 2D Materials

The ability to deterministically fabricate nanoscale architectures with atomic precision is the central goal of nanotechnology, whereby highly localized changes in the atomic structure can be exploited to control device properties at their fundamental physical limit. Here, an automated, feedback-controlled atomic fabrication method is reported and the formation of 1D–2D heterostructures in MoS 2 is demonstrated through selective transformations along specific crystallographic orientations. The atomic-scale probe of an aberration-corrected scanning transmission electron microscope (STEM) is used, and the shape and symmetry of the scan pathway relative to the sample orientation are controlled. The focused and shaped electron beam is used to reliably create Mo 6 S 6 nanowire (MoS-NW) terminated metallic-semiconductor 1D–2D edge structures within a pristine MoS 2 monolayer with atomic precision. From these results, it is found that a triangular beam path aligned along the zig-zag sulfur terminated (ZZS) direction forms stable MoS-NW edge structures with the highest degree of fidelity without resulting in disordering of the surrounding MoS 2 monolayer. Density functional theory (DFT) calculations and ab initio molecular dynamic simulations (AIMD) are used to calculate the energetic barriers for the most stable atomic edge structures and atomic transformation pathways. These discoveries provide an automated method to improve understanding of atomic-scale transformations while opening a pathway toward more precise atomic-scale engineering of materials.

2D materials↗

Precise Tailoring of Lithium-Ion Transport for Ultralong-Cycling Dendrite-Free All-Solid-State Lithium Metal Batteries

All-solid-state lithium metal batteries can address crucial challenges regarding insufficient battery cycling life and energy density. The demonstration of long-cycling dendrite-free all-solid-state lithium metal batteries requires precise tailoring of lithium-ion transport of solid-state electrolytes (SSEs). Here, in this work, a proof of concept is reported for precise tailoring of lithium-ion transport of a halide SSE, Li 3 InCl 6 , including intragranular (within grains) but also intergranular (between grains) lithium-ion transport. Lithium-ion migration tailoring mechanism in crystals is developed by unexpected enhanced Li, In, and Cl vacancy populations and lower energy barrier for hopping. The lithium-ion transport tailoring mechanism between the grains is determined by the elimination of voids between grains and the formation of unexpected supersonic conducting grain boundaries, boosting the lithium dendrite suppression ability of SSE. Due to boosted lithium-ion conduction and dendrite-suppression ability, the all-solid-state lithium metal batteries coupled with Ni-rich LiNi 0.83 Co 0.12 Mn 0.05 O 2 cathodes and lithium metal anodes demonstrate breakthroughs in electrochemical performance by achieving extremely long cycling life at a high current density of 0.5 C (2000 cycles, 93.7% capacity retention). This concept of precise tailoring of lithium-ion transport provides a cost, time, and energy efficient solution to conquer the remaining challenges in all-solid-state lithium-metal batteries for fast developing electric vehicle markets.

25 ENERGY STORAGE↗

Quantitative Electron Beam‐Single Atom Interactions Enabled by Sub‐20‐pm Precision Targeting

The ability to probe and control matter at the picometer scale is essential for advancing quantum and energy technologies. Scanning transmission electron microscopy offers powerful capabilities for materials analysis and modification, but sample damage, drift, and scan distortions hinder single atom analysis and deterministic manipulation. Materials analysis and modification via electron–solid interactions can be transformed by precise delivery of electrons to a specified atomic location, maintaining the beam position despite drift, and minimizing collateral dose. Here a fast, low-dose, sub-20-pm precision electron beam positioning technique is developed, “atomic lock-on,” (ALO), which offers the ability to position the beam on a specific atomic column without previously irradiating that column. This technique is used to lock onto a single selected atomic location to repeatedly measure its weak electron energy loss signal despite sample drift. Moreover, electron beam-matter interactions in single atomic events are measured with μ s time resolution. This enables observation of single-atom dynamics, such as atomic bistability, revealing partially bonded atomic configurations and recapture phenomena. This opens prospects for using electron microscopy for high-precision measurements and deterministic control of matter for quantum technologies.

2D materials↗

Sensor selection and tool wear prediction with data‐driven models for precision machining

Abstract Estimation of tool wear in precision machining is vital in the traditional subtractive machining industry to reduce processing cost, improve manufacturing efficiency and product quality. In this vein, fusion of time and frequency‐domain features of commonly sensed signals can provide an early indication of tool wear and improve its prediction accuracy for prognostics and health management. This paper presents a data‐driven methodology and a complete tool chain for the inference of precision machining tool wear from fused machine measurements, such as cutting force, power, audio and vibration signals, and quantify the usefulness of each measurement. Indicators of tool wear are extracted from time‐domain signal statistics, frequency‐domain analysis, and time‐frequency domain analysis. Correlation coefficients between the extracted features (indicators) and the tool wear are used to select the most informative features. Principal Component Analysis and Partial Least‐Squares are used to reduce the dimensionality of the feature space. Regression models, including linear regression, support vector regression, Decision tree regression, neural network regression and Gaussian process regression, are used to predict the tool wear using data from a Haas milling machine performing spiral boss face milling. The performance of the regression models based on subsets of sensors validates the preliminary estimates about the saliency of the sensors. The experimental results show that the proposed methods can predict the machine tool wear precisely, with readily available sensor measurements. Neural network and Gaussian process regression were able to achieve good estimates of tool wear at different machine operating conditions. The most informative signal in predicting tool wear was shown to be the vibration signal. Time‐frequency domain features were the most informative features among the combination of features of three domains. In addition, using partial least squares components extracted from the original features of signals led to higher prediction accuracy.

Han, Seulki↗

Precise Control of Dissipative Self-assembly by Light and Electricity

Nature-inspired synthetic dissipative self-assemblies have attracted much attention recently. However, it remains a major challenge to achieve precise control over dissipative supramolecular assembly structures and functions of self-contained systems. Here we combine light and electricity as two clean, and spatiotemporally addressable fuels to provide precise control over the morphology for dissipative self-assembly of a perylene bisimide glycine (PBIg) building block in a self-contained solution. In this design, electrochemical oxidation provides the positive fuel to activate PBIg self-assembly while photoreduction supplies the negative fuel to deactivate the system for disassembly. Further, through programming the two counteracting fuels, we demonstrated the control of PBIg self-assembly into a variety of assembly morphologies in a self-contained system. In addition, by exerting light and electrical dual fuels simultaneously, we could create an active homeostasis exhibiting dynamic instability, leading to morphological change to asymmetric assemblies with curvatures. Such precise control over self-assembly of self-contained systems may find future applications in programming complex active materials as well as formulating pharmaceutical reagents with desired morphologies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Observable optimization for precision theory: machine learning energy correlators

The practice of collider physics typically involves the marginalization of multi-dimensional collider data to uni-dimensional observables relevant for some physics task. In many cases, such as classification or anomaly detection, the observable can be arbitrarily complicated, such as the output of a neural network. However, for precision measurements, the observable must correspond to something computable systematically beyond the level of current simulation tools. In this work, we demonstrate that precision-theory-compatible observable space exploration can be systematized by using neural simulation-based inference techniques from machine learning. We illustrate this approach by exploring the space of marginalizations of the energy 3-point correlator to optimize sensitivity to the top quark mass. We first learn the energy-weighted probability density from simulation, then search in the space of marginalizations for an optimal triangle shape. Although simulations and machine learning are used in the process of observable optimization, the output is an observable definition which can be then computed to high precision and compared directly to data without any memory of the computations which produced it. We find that the optimal marginalization is isosceles triangles on the sphere with a side ratio approximately $1 : 1 : \sqrt{2}$ (i.e. right triangles) within the set of marginalizations we consider.

Jets and Jet Substructure↗

Type-I 2HDM under the Higgs and electroweak precision measurements

We explore the extent to which future precision measurements of the Standard Model (SM) observables at the proposed Z -factories and Higgs factories may have impacts on new physics beyond the Standard Model, as illustrated by studying the Type-I Two-Higgs-doublet model (Type-I 2HDM). We include the contributions from the heavy Higgs bosons at the tree-level and at the one-loop level in a full model-parameter space. While only small tan β region is strongly constrained at tree level, the large tan β region gets constrained at loop level due to tan β enhanced tri-Higgs couplings. We perform a multiple variable χ 2 fit with non-alignment and non-degenerate masses. We find that the allowed parameter ranges could be tightly constrained by the future Higgs precision measurements, especially for small and large values of tan β . Indirect limits on the masses of heavy Higgs bosons can be obtained, which can be complementary to the direct searches of the heavy Higgs bosons at hadron colliders. We also find that the expected accuracies at the Z -pole and at a Higgs factory are quite complementary in constraining mass splittings of heavy Higgs bosons. The typical results are | cos( β - α ) | < 0 . 05 , | Δ m Φ | < 200 GeV, and tan β ≳ 0 . 3. The reaches from CEPC, Fcc-ee and ILC are also compared, for both Higgs and Z -pole precision measurements. Comparing to the Type-II 2HDM, the 95% C.L. allowed range of cos( β - α ) is larger, especially for large values of tan β .

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Higgs-precision constraints on colored naturalness

The presence of weak-scale colored top partners is among the simplest solutions to the Higgs hierarchy problem and allows for a natural electroweak scale. We examine the constraints on generic colored top partners coming solely from their effect on the production and decay rates of the observed Higgs with a mass of 125 GeV. We use the latest Higgs precision data from the Tevatron and the LHC as of EPS 2017 to derive the current limits on spin-0, spin-1/2, and spin-1 colored top partners. We also investigate the expected sensitivity from the Run 3 and Run 4 of the LHC, as well from possible future electron-positron and proton-proton colliders, including the ILC, CEPC, FCC-ee, and FCC-hh. We discuss constraints on top partners in the Minimal Supersymmetric Standard Model and Little Higgs theories. We also consider various model-building aspects — multiple top partners, modified couplings between the Higgs and Standard-Model particles, and non-Standard-Model Higgs sectors — and evaluate how these weaken the current limits and expected sensitivities. By modifying other Standard-Model Higgs couplings, we find that the best way to hide low-mass top partners from current data is through modifications of the top-Yukawa coupling, although future measurements of top-quark-pair production in association with a Higgs will extensively probe this possibility. We also demonstrate that models with multiple top partners can generically avoid current and future Higgs precision measurements. Nevertheless, some of the model parameter space can be probed with precision measurements at future electron-positron colliders of, for example, the e + e - → Zhcrosssection.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Tracking Error Learning Control for Precise Mobile Robot Path Tracking in Outdoor Environment

This article presents a Tracking-Error Learning Control (TELC) algorithm for precise mobile robot path tracking in off-road terrain. In traditional tracking error-based control approaches, feedback and feedforward controllers are designed based on the nominal model which cannot capture the uncertainties, disturbances and changing working conditions so that they cannot ensure precise path tracking performance in the outdoor environment. In TELC algorithm, the feedforward control actions are updated by using the tracking error dynamics and the plant-model mismatch problem is thus discarded. Therefore, the feedforward controller gradually eliminates the feedback controller from the control of the system once the mobile robot has been ontrack. In addition to the proof of the stability, it is proven that the cost functions do not have local minima so that the coefficients in TELC algorithm guarantee that the global minimum is reached. The experimental results show that the TELC algorithm results in better path tracking performance than the traditional tracking error-based control method. The mobile robot controlled by TELC algorithm can track a target path precisely with less than 10 cm error in off-road terrain.

42 ENGINEERING↗

Calculation of machine precision second order derivatives using dual-complex numbers

It is well known that both complex and dual numbers can be employed to obtain machine precision first-order derivatives; however, neither, on their own, can compute machine precision 2nd order derivatives. To address this limitation, it is demonstrated in this paper that combined dual-complex numbers can be used to compute machine precision 1st and 2nd order derivatives. The dual-complex approach is simpler than utilizing multicomplex or hyper-dual numbers as existing dual libraries can be used as is or easily augmented to accept complex numbers, and the complexity of developing, integrating, and deploying multicomplex or hyper-dual libraries is avoided. The efficacy of this approach is demonstrated for both univariate and multivariate functions. Finally, source code examples using the Python, Julia, and Mathematica languages are provided as supplemental material.

97 MATHEMATICS AND COMPUTING↗

Alternated Prone and Supine Whole-Breast Irradiation Using IMRT: Setup Precision, Respiratory Movement and Treatment Time

Purpose: The objective of this study was to compare setup precision, respiration-related breast movement and treatment time between prone and supine positions for whole-breast irradiation. Methods and Materials: Ten patients with early-stage breast carcinoma after breast-conserving surgery were treated with prone and supine whole breast-irradiation in a daily alternating schedule. Setup precision was monitored using cone-beam computed tomography (CBCT) imaging. Respiration-related breast movement in the vertical direction was assessed by magnetic sensors. The time needed for patient setup and for the CBCT procedure, the beam time, and the length of the whole treatment slot were also recorded. Results: Random and systematic errors were not significantly different between positions in individual patients for each of the three axes (left-right, longitudinal, and vertical). Respiration-related movement was smaller in prone position, but about 80% of observations showed amplitudes <1 mm in both positions. Treatment slots were longer in prone position (21.2 {+-} 2.5 min) than in supine position (19.4 {+-} 0.8 min; p = 0.044). Conclusion: Comparison of setup precision between prone and supine position in the same patient showed no significant differences in random and systematic errors. Respiratory movement was smaller in prone position. The longer treatment slots in prone position can probably be attributed to the higher repositioning need.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

How Advances in Imaging Will Affect Precision Radiation Oncology

Radiation oncology is 1 of the most structured disciplines in medicine. It is of a highly technical nature with reliance on robotic systems to deliver intervention, engagement of diverse expertise, and early adoption of digital approaches to optimize and execute the application of this highly effective cancer treatment. As a localized intervention, the dependence on sensitive, specific, and accurate imaging to define the extent of disease, its heterogeneity, and adjacency to normal tissues directly affects the therapeutic ratio. Image-based in vivo temporal monitoring of the response to treatment enables adaptation and further affects the therapeutic ratio. Thus, more precise intervention will enable fractionation schedules that better interoperate with advances such as immunotherapy. In the data set–rich era that promises precision and personalized medicine, the radiation oncology field will integrate these new data into highly protocoled pathways of care that begin with multimodality prediction and enable patient-specific adaptation of therapy based on quantitative measures of the individual's dose–volume temporal trajectory and midtherapy predictions of response. In addition to advancements in computed tomography imaging, emerging technologies, such as ultra-high-field magnetic resonance and molecular imaging will bring new information to the design of treatments. Next-generation image guided radiation therapy systems will inject high specificity and sensitivity data and stimulate adaptive replanning. In addition, a myriad of pre- and peritherapeutic markers derived from advances in molecular pathology (eg, tumor genomics), automated and comprehensive imaging analytics (eg, radiomics, tumor microenvironment), and many other emerging biomarkers (eg, circulating tumor cell assays) will need to be integrated to maximize the benefit of radiation therapy for an individual patient. We present a perspective on the promise and challenges of fully exploiting imaging data in the pursuit of personalized radiation therapy, drawing from the presentations and broader discussions at the 2016 American Society of Therapeutic Radiation Oncology–National Cancer Institute workshop on Precision Medicine in Radiation Oncology (Bethesda, MD).

62 RADIOLOGY AND NUCLEAR MEDICINE↗