Search NASA⌕ Search

SEARCH · Search NASA

Results for “pressure sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

A stagnation pressure probe for use in supersonic flow

Probe was developed which is capable of recording true stagnation pressure in supersonic and subsonic flows. Static pressure orifices in the compression surface allow probe to be used as combined flow direction and stagnation pressure sensor.

Goodyer, M. J.↗

The role of fluctuating forces in the generation of compressor noise

The results of a theoretical and experimental study on the role of aerodynamically-induced fluctuating forces in the sound generation by axial-flow compressors are presented. Analytical models for the generation and radiation of sound by rotor/stator combinations were developed. For the experimental substantiation of the analytical results, the technology was developed to measure fluctuating forces directly on rotating airfoils using miniature differential-pressure sensors and FM telemetry. Under the assumption of full coherence of the force field on the blade, radiated sound power was predicted from the force measurements on blades and compared with measured sound power. Both broadband radiation from a single rotating airfoil and discrete frequency radiation due to interaction of multi-bladed stator/rotor configurations were investigated. The results indicate the necessity to obtain information on the details of the force field for accurate prediction of the radiated sound spectrum.

Heller, H. H.↗

A Wind Tunnel Flight Correlation of Apollo 15 Sonic Boom

A correlation of sonic boom pressure signatures recorded during reentry of the Apollo 15 command module with wind-tunnel signatures extrapolated to flight distances has been made for Mach numbers of 1.16 and 4.57. The flight pressure signatures were recorded by pressure sensors located onboard ships positioned near the ground track while the wind-tunnel signatures were measured during tests of a 0.016-scale model of the command module. The agreement between estimates based on wind-tunnel data and flight measurements was better at Mach 4.57 than at Mach 1.16.

Hicks, R. M.↗

Apparatus for absolute pressure measurement

An absolute pressure sensor (e.g., the diaphragm of a capacitance manometer) was subjected to a superimposed potential to effectively reduce the mechanical stiffness of the sensor. This substantially increases the sensitivity of the sensor and is particularly useful in vacuum gauges. An oscillating component of the superimposed potential induced vibrations of the sensor. The phase of these vibrations with respect to that of the oscillating component was monitored, and served to initiate an automatic adjustment of the static component of the superimposed potential, so as to bring the sensor into resonance at the frequency of the oscillating component. This establishes a selected sensitivity for the sensor, since a definite relationship exists between resonant frequency and sensitivity.

Hecht, R.↗

Extendible probe for atmosphere sampling

Sampling probe is extended through small plug in heat shield by loaded bellows to sample planetary atmosphere for compositional analysis and total pressure during entry of space probe. Assembly prevents contamination of sample by gases from pyrotechnic device and serves as sealed plenum for atmospheric pressure sensor.

Jones, W. J.↗

Test evaluation of potential heatshield contamination of an outer planet probe's gas sampling system

The feasibility of retaining the heat shield for outer planet probes was investigated as a potential source of atmospheric sample contamination by outgassing. The onboard instruments which are affected by the concept are the pressure sensor, temperature sensor, IR detector, nephelometer, and gas sampling instruments. It was found that: (1) The retention of the charred heatshield and the baseline atmospheric sampling concepts are compatible with obtaining noncontaminated atmospheric samples. (2) Increasing the sampling tube length so that it extends beyond the viscous boundary layer eliminates contamination of the atmospheric sample. (3) The potential for contamination increases with angle of attack.

Kessler, W. C.↗

Investigation of space shuttle vehicle 140C configuration orbiter (model 16-0) wheel well pressure loads in the Rockwell International 7.75 x 11 foot wind tunnel (OA143)

Experimental aerodynamic investigations were conducted on a sting mounted .0405-scale representation of the 140C outer mold line space shuttle orbiter configuration in the Rockwell International 7.75 x 11.00 foot low speed wind tunnel. The primary test objectives were to define the orbiter wheel well pressure loading and its effects on landing gear thermal insulation and to investigate the pressure environment experienced by both the horizontal flight nose probe and air vent door probes. Steady state and dynamic pressure values were recorded in the orbiter nose gear well, left main landing gear well, horizontal flight nose probe, and both left and right air vent door probe. All steady state pressure levels were measured by Statham differential pressure transducers while dynamic pressure levels were recorded by Kulite high frequency response pressure sensors.

Mennell, R. C.↗

A simple total energy sensor

This research concerns a simple technique for total energy compensation having the primary requirement of good compensation with a low cost, easy to make sensor. A comprehensive library search and a small wind tunnel were used to explore fundamentals and to develop a number of probes which were flight tested with satisfactory results. Simple probe configurations were tested using the characteristics of laminar flow separation around a small cylinder to produce a sensor pressure having the desired relationship between static and dynamic pressures. Wind tunnel and flight tests confirmed the concepts for a wide range of speeds, altitudes, and flow directions encountered in soaring. Data and findings are presented, along with a discussion of factors important to total energy compensation.

Nicks, O. W.↗

Compressor blade setting angle accuracy study, volume 1

The aerodynamic test of a small, single stage, highly loaded, axial flow transonic compressor is covered. The stage was modified by fabricating a 24 blade rotor with mis-set blades in a repeating pattern - two degrees closed from nominal, two degrees open from nominal and nominal. The unit was instrumented to determine overall performance and average blade element data. High-response, dynamic pressure probes were installed to record pressure patterns at selected points in the flowpath. Testing was conducted at speeds from 70 to 94% of design equivalent speed with a conventional casing and also with circumferential grooves over the rotor tip. Testing indicated severe performance penalties were incurred as a result of the mis-set blading. Lower flow, pressure ratio, and efficiency were observed for the stage with or without casing treatment. Periodic pressure variations were detected at every location where high response pressure sensors were located and were directly related to blading geometry.

Holman, F. F.↗

Biomedical technology transfer: Applications of NASA science and technology

The major efforts of the Stanford Biomedical Applications Team Program at the Stanford University School of Medicine for the period from October 1, 1975 to September 31, 1976 are covered. A completed EMG biotelemetry system which monitors the physiological signals of man and animals in space related research is discussed. The results of a pilot study involving lower body negative pressure testing in cardiac patients has been completed as well as the design and construction of a new leg negative pressure unit for evaluating heart patients. This technology utilizes vacuum chambers to stress the cardiovascular system during space flight. Laboratory tests of an intracranial pressure transducer, have been conducted. Extremely stable long term data using capacative pressure sensors has lead to the order of commercially manufactured monitoring systems base. Projects involving commercialization are: flexible medical electrodes, an echocardioscope, a miniature biotelemetry system, and an on-line ventricular contour detector.

Source record↗

Buffet characteristics of the F-8 supercritical wing airplane

The buffet characteristics of the F-8 supercritical wing airplane were investigated. Wing structural response was used to determine the buffet characteristics of the wing and these characteristics are compared with wind tunnel model data and the wing flow characteristics at transonic speeds. The wingtip accelerometer was used to determine the buffet onset boundary and to measure the buffet intensity characteristics of the airplane. The effects of moderate trailing edge flap deflections on the buffet onset boundary are presented. The supercritical wing flow characteristics were determined from wind tunnel and flight static pressure measurements and from a dynamic pressure sensor mounted on the flight test airplane in the vicinity of the shock wave that formed on the upper surface of the wing at transonic speeds. The comparison of the airplane's structural response data to the supercritical flow characteristics includes the effects of a leading edge vortex generator.

Deangelis, V. M.↗

Comparison of Estimated with Measured Maximum Instantaneous Distortion Using Flight Data from an Axisymmetric Mixed Compression Inlet

YF-12C flight-measured inlet dynamic distortion data are compared with predictions made on the basis of the method reported by Melick et al. (1976). The YF-12C aircraft is a twin engine aircraft capable of speeds above 3. The inlets have a translating spike to control the inlet throat area. A bypass system is used to control the terminal shock of the inlet for operation in the mixed compression mode. The dynamic data were obtained with the aid of 24 high frequency response total pressure sensors. The model of Melick et al. is discussed along with the computer program used to implement the model. It is found that the predictions of maximum instantaneous distortion are within 20 percent of the measured values, which had been obtained at Mach numbers of 1.8, 2.1, 2.5, and 3.0.

Brilliant, H. M.↗

Application of microelectronic technology to general aviation flight control

This paper presents several different methods that can be used to determine the aircraft orientation (attitude) without direct measurement. The methods combine state estimation techniques with measurements from solid state pressure sensors, accelerometers, and magnetometers to determine the aircraft state. The paper demonstrates how the estimation algorithms were validated and compared using flight test data, and it presents results of performance sensitivity analyses of sensor error, modeling inaccuracies, and wind disturbance effects on the attitude estimation errors. If implemented, the methods presented could make it possible to eliminate directional and vertical gyros and to change from many isolated sensors to an integrated, small, reliable sensing package for determining the aircraft state.

Sorensen, J. A.↗

Wideband EMG telemetry system

Miniature, individual crystal-controlled RF transmitters located in EMG pressure sensors simplifies multichannel EMG telemetry for electronic gait monitoring. Transmitters which are assigned operating frequencies within 174 - 216 MHz band have linear frequency response from 20 - 2000 Hz and operate over range of 15 m.

Rosatino, S. A.↗

Adaptation of ion beam technology to microfabrication of solid state devices and transducers

A number of areas were investigated to determine the potential uses of ion beam techniques in the construction of solid state devices and transducers and the packaging of implantable electronics for biomedical applications. The five areas investigated during the past year were: (1) diode-like devices fabricated on textured silicon; (2) a photolithographic technique for patterning ion beam sputtered PVC (polyvinyl chloride); (3) use of sputtered Teflon as a protective coating for implantable pressure sensors; (4) the sputtering of Macor to seal implantable hybrid circuits; and (5) the use of sputtered Teflon to immobilize enzymes.

Topich, J. A.↗