Search NASA⌕ Search

SEARCH · Search NASA

Results for “pressure sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Convective Vortices and Dust Devils Detected and Characterized by Mars 2020

Abstract We characterize vortex and dust devils (DDs) at Jezero from pressure and winds obtained with the Mars Environmental Dynamics Analyzer (MEDA) instrument on Mars 2020 over 415 Martian days (sols) ( Ls = 6°–213°). Vortices are abundant (4.9 per sol with pressure drops >0.5 Pa correcting from gaps in coverage) and they peak at noon. At least one in every five vortices carries dust, and 75% of all vortices with Δ p > 2.0 Pa are dusty. Seasonal variability was small but DDs were abundant during a dust storm ( Ls = 152°–156°). Vortices are more frequent and intense over terrains with lower thermal inertia favoring high daytime surface‐to‐air temperature gradients. We fit measurements of winds and pressure during DD encounters to models of vortices. We obtain vortex diameters that range from 5 to 135 m with a mean of 20 m, and from the frequency of close encounters we estimate a DD activity of 2.0–3.0 DDs km −2 sol −1 . A comparison of MEDA observations with a Large Eddy Simulation of Jezero at Ls = 45° produces a similar result. Three 100‐m size DDs passed within 30 m of the rover from what we estimate that the activity of DDs with diameters >100 m is 0.1 DDs km −2 sol −1 , implying that dust lifting is dominated by the largest vortices in Jezero. At least one vortex had a central pressure drop of 9.0 Pa and internal winds of 25 ms −1 . The MEDA wind sensors were partially damaged during two DD encounters whose characteristics we elaborate in detail.

Hueso, R.↗

Temperature locale sensors and related methods

Temperature locale sensors include an enclosure defining a sealed volume with a phase-change material therein at a known pressure. The phase-change material is formulated to exhibit a gas-to-solid phase change, without condensing to a liquid phase, at the known pressure and a targeted temperature, i.e., the material's “deposition temperature.” The phase-change material—while at least partially in gaseous form, either initially or after sublimation—is exposed to an environment with temperatures varying by location, including a maximum temperature above the phase-change material's deposition temperature and other temperatures at or below the deposition temperature. The gaseous phase-change material, in a location at the deposition temperature, solidifies from its gaseous phase to form solid grain deposits on a surface within the enclosure of the sensor. The solid deposits precisely identify the location of the specific, targeted deposition temperature.

Skifton, Richard S.↗

Correlating Time-Resolved Pressure Measurements With Rim Sealing Effectiveness for Real-Time Turbine Health Monitoring

Purge flow is bled from the upstream compressor and supplied to the under-platform region to prevent hot main gas path ingress that damages vulnerable under-platform hardware components. A majority of turbine rim seal research has sought to identify methods of improving sealing technologies and understanding the physical mechanisms that drive ingress. While these studies directly support the design and analysis of advanced rim seal geometries and purge flow systems, the studies are limited in their applicability to real-time monitoring required for condition-based operation and maintenance. As operational hours increase for in-service engines, this lack of rim seal performance feedback results in progressive degradation of sealing effectiveness, thereby leading to reduced hardware life. To address this need for rim seal performance monitoring, the present study utilizes measurements from a one-stage turbine research facility operating with true-scale engine hardware at engine-relevant conditions. Time-resolved pressure measurements collected from the rim seal region are regressed with sealing effectiveness through the use of common machine learning techniques to provide real-time feedback of sealing effectiveness. Two modelling approaches are presented that use a single sensor to predict sealing effectiveness accurately over a range of two turbine operating conditions. Results show that an initial purely data-driven model can be further improved using domain knowledge of relevant turbine operations, which yields sealing effectiveness predictions within three percent of measured values.

Compressors↗

Feasibility study for test rig assessments of fish passage conditions in a Kaplan turbine

The assessment of fish passage conditions in hydroelectric turbines consists of identifying and quantifying physical magnitudes leading to increased risks of injury of fish passing through turbines in operation. Such assessments are usually carried out either with the use of computer-based methods during design or with field testing of live fish and sensors passing through prototypes. A method in between consists of test rig experimentation, which is critical for testing fish-focused design concepts and offers the opportunity for implementing the most effective design measures for improved fish survivability. However, fish-related assessments in test rigs are not sufficiently documented for industrial applications. This work presents the main findings of an experimental campaign to quantify fish-related hydraulic magnitudes in a physical model of a Kaplan turbine in a commercial test rig. Two operating conditions were tested by releasing miniaturized autonomous sensor devices (termed Sensor Fish Mini) at the turbine intake flow, passing them through the runner in motion and recovering them at the draft tube exit. During passage, time series of acceleration, absolute pressure and rotational velocity were recorded. The recordings were then interpreted to determine the magnitude and likely location of hydraulic stressors hazardous to fish. The statistical tests on the reported measurements indicated that low pressure, collisions on the runner and rotations in the draft tube were not different between the two tested operating points. On the other hand, pressure drop and collision rates on the distributor differed considerably as a function of net head. The outcomes of this investigation showed that test rig evaluations of fish-related properties with Sensor Fish Mini can contribute to an evidence-based development of turbine geometries designed for providing safer passage conditions. Future work will investigate the scaling of test rig measurements to hydraulically equivalent magnitudes in the prototype and their biological consequences.

13 HYDRO ENERGY↗

Time resolved X-ray diffraction using the FIDDLE diagnostic at NIF: Preliminary assessment of diffraction precision

The Flexible Imaging Diffraction Diagnostic for Laser Experiments (FIDDLE) is a new diagnostic at the National Ignition Facility (NIF) designed to observe in situ solid-solid phase changes at high pressures using time resolved X-ray diffraction. FIDDLE currently incorporates five Icarus Ultrafast X-ray Imager sensors that take 2 ns snapshots and can be tuned to collect X-rays for tens of ns. The platform utilizes the laser power at NIF for both the laser drive and the generation of 10 keV X-rays for ~10 ns using a Ge backlighter foil. We aim to use FIDDLE to observe diffraction at different times during compression to probe the kinetics of phase changes. Pb undergoes two solid-solid phase transitions during ramp compression: from FCC to HCP and HCP to BCC. Results will be reported on some of the first shots using the FIDDLE diagnostic at NIF on ramp compressed Pb to a peak pressure of ~110 GPa and a single undriven CeO2 calibration shot. A discussion of the uncertainties in the observed diffraction is included.

Vennari, C. E.↗

Design of Microwave Resonant Cavity Transducer. Development of sensor performance model of microwave cavity flow meter for advanced reactor high temperature fluids

High-temperature fluid reactors, such as molten salt cooled reactors (MSCR) and sodium fast reactors (SFR), are a promising advanced reactor option. Measurement of high-temperature fluid process variables, in particular the flow inside the pressure vessel, is a challenging task because of harsh environment, which includes high radiation, high temperature, and contact with highly corrosive coolant fluid. We are investigating a microwave cavity-based transducer for high-temperature fluid flow sensing. This sensor is a hollow metallic cylindrical cavity, which can be fabricated from stainless steel, and as such is expected to be resilient to radiation, high temperature and corrosive environment of MSCR and SFR. The principle of sensing consists of making one wall of the cylindrical cavity flexible enough so that dynamic pressure, which is proportional to fluid velocity, will cause membrane deflection. A cavity is characterized by its resonant frequencies. Membrane deflection causes cavity volume change, which leads to a shift in the resonant frequency. Feasibility of the flow sensor is evaluated with signal sensitivity using COMSOL computer simulations. A right cylinder geometry stainless steel cavity with dimeter of 0.8in was investigated. We choose membrane thickness of 10mil, so that corrosion anticipated to proceed at the rate of 1mil/year in liquid sodium would affect no more than 10% of the membrane. Using the properties of liquid sodium fluid, and stainless-steel material property values at 500oC, we calculate frequency shift for a range of values of fluid velocity from 0.5m/s to 2m/s. Results of computer simulations indicate measurable sensitivity to flow for this cavity design. Following these simulations, we have developed a preliminary design for fabrication of a transducer operating in microwave K-band for proof-of-principle tests.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Applications of Strain-Coupled Magnetoelectric Composites

This article deals with research, development and future directions of magnetoelectric composites for practical devices applications. In the past 20 years there has been a surge of research in the area of multiferroics (MF) and magnetoelectrics (ME) due to their potential to replace existing technologies based only on ferroelectric or ferromagnetic materials. Some of the magnetoelectric composites show exceptionally high potential in the area of magnetic field sensors, however, work remains before commercialization can be realized. The cross coupling among various ferroic parameters in magnetoelectric composites is several orders higher than single phase magetoelectrics, which make its favorable for low detection (nT or pT) magnetic field sensors. Advances in both layered structures or controlled three-dimensional matrix composites for applications as magnetoelectric nonvolatile memory elements are both required. Robust cross-coupling among various parameters with more than four logic states and its compatibility with complementary-symmetry metal–oxide–semiconductor (CMOS) technology are the main requirements for heterostructure magnetoelectric thin films. The major hurdles in the area of magnetoelectric nonvolatile memory elements are poor interfacial properties and weak magnetoelectric coupling for high density fast read and write processes. Another potential area is strained coupled magneto-electric composites where magnetostriction mediated dimensional change in the magnetic layer effectively modulate the change in the dimension of piezoelectric layers via piezostriction, which leads to a strong ME coupling where their coupling magnitude is sufficient for magnetic field sensors. Energy harvesters based on magnetoelectric composites are also intriguing concepts to capture various types of waste energy, in the form mechanical vibration, pressure, wind energy, hydrothermal and waste temperature.

36 MATERIALS SCIENCE↗

Development of an ERT‐Based Framework for Bentonite Buffers Monitoring From Laboratory Tests: 1. Characterizing Thermal–Hydrological–Mechanical Processes

Abstract Bentonite clay is widely used in engineered barrier systems for the permanent disposal of high‐level radioactive waste due to its low permeability, high swelling capacity, and thermal stability. However, the complex thermal‐hydrological‐mechanical (THM) processes induced by heating from decaying radioactive waste and hydration from surrounding rock can lead to heterogeneous changes that are difficult to measure and predict. This study develops an Electrical Resistivity Tomography (ERT)‐based framework for monitoring THM processes, progressing from sample‐scale to bench‐scale tests, to inform field‐scale applications. Sample‐scale tests analyzed small bentonite samples under controlled variations in water content, temperature, and porosity to establish fundamental resistivity relationships. Bench‐scale tests involved larger bentonite columns subjected to heating (up to 200°C) and hydration under controlled pressure, simulating repository conditions. ERT measurements, complemented by X‐ray CT imaging, temperature monitoring, and tracing sensors, revealed coupled THM processes, such as hydration‐induced compression, swelling, and thermal gradients, leading to complex resistivity patterns. The results demonstrate the potential of ERT for capturing THM‐induced resistivity changes, though challenges remain in upscaling and quantitative analysis. This study evaluates laboratory test capabilities and proposes future improvements for understanding THM‐induced resistivity responses. A conceptual framework for ERT implementation in field‐scale monitoring is presented, synthesizing findings from both scales and exploring how ERT data can inform long‐term modeling and reduce prediction uncertainties. Overall, this ERT‐based framework offers a robust method for monitoring bentonite buffers, aiding in early issue detection and supporting the safe long‐term disposal of radioactive waste in geological repositories, while highlighting the need for future development. Plain Language Summary Bentonite clay is crucial in engineered barrier systems (EBS) for containing high‐level radioactive waste due to its ability to absorb water, swell, seal and remain stable under high temperatures. When bentonite absorbs water and heats up from radioactive decay, it experiences complex changes in its physical and mechanical properties. Understanding these changes is important for ensuring the long‐term safety and effectiveness of EBS. This study used Electrical Resistivity Tomography (ERT), a non‐invasive method that measures electrical conductivity to monitor these changes during laboratory experiments. The ERT data revealed significant variations in resistivity corresponding to changes in water content, temperature, and density, providing detailed spatial and temporal insights into the behavior of bentonite. These findings enhance our ability to predict the long‐term performance of bentonite barriers, ensuring the safe containment of radioactive waste. By improving our understanding of bentonite's behavior, this research supports the development of more reliable and effective barrier systems for radioactive waste disposal, protecting the environment and public health. Key Points ERT monitoring was employed to capture resistivity changes in bentonite during controlled heating and hydration experiments, providing insights into THM processes ERT data reveal significant resistivity changes correlated with water content, temperature, and mechanical effects, enhancing the understanding of THM dynamics in bentonite This study explores the potential of the framework for application in field‐scale EBS monitoring, emphasizing the need for integrating additional geophysical methods for comprehensive subsurface imaging

Chen, Hang↗

Thermodynamic Modeling of Complex Solid Solutions in the Lu-H-N System via Graph Neural Network Accelerated Monte Carlo Simulations

Metal hydrides are important across diverse applications, such as hydrogen storage, batteries, gas sensors, nuclear reactions, and high-temperature superconductivity. Previous computational studies of metal hydrides under extreme pressures, e.g., 𝑂⁡(10 2 ) ⁢GPa, usually treat them as stoichiometric compounds without considering interstitial lattice disorder. As pressures become more moderate in the 𝑂⁡(10 0 ) ⁢GPa and below range, hydrogen disorder at interstitial lattice sites becomes prominent, e.g., in the N-doped Lu hydride that was recently claimed superconducting near 1 GPa. Further adding compositional complexity from alloying and/or multielement interstitial occupation makes elucidating pressure- and temperature-dependent observables intractable by first-principles calculations alone. We therefore propose a lattice graph neural-network surrogate modeling approach to predict configuration- and pressure-dependent equation-of-state properties. Their efficiency permits Monte Carlo simulations to calculate Gibbs energies and pressure-dependent phase diagrams, thereby revealing insights into the synthesis conditions required for achieving desired phase equilibria. We demonstrate this concept for the compositionally complex cubic Lu(H,N,Va) 3 system where three constituents (hydrogen, nitrogen and vacancy) have disordered multielement interstitial occupancies and insights into pressure-dependent phase equilibria are critically needed, e.g., N-doping levels can significantly lower dehydrogenation temperatures and provide a new strategy to optimize hydrogen-storage alloys. This work can improve the thermodynamic understanding of the Lu-H-N system and help rational synthesis of N-doped Lu hydrides, but more generally demonstrates an efficient approach to model pressure-dependent thermodynamics of multicomponent solid solutions.

Monte Carlo methods↗

Evaluating the Feasibility of Using Strain Measured During Sinusoidal Rate Pumping Tests to Characterize an Aquifer

Pumping tests with sinusoidal variation in pumping rate have been proposed as a method for improving aquifer characterization. These tests can interrogate a larger aquifer volume than slug tests and they can be more sensitive to small variations in drawdown. Current methods of using sinusoidal variations of rate are based on measuring pressure signals from the reservoir or aquifer, which requires access to monitoring wells. An alternative approach has been developed that measures the strain in the vadose zone instead of pressure in the reservoir. An instrument has been developed at Clemson University that can measure small strains using optical fiber sensors, and we propose that it can be used to measure strain during sinusoidal pumping tests. The objective of this project is to evaluate the feasibility of measuring and interpreting the vertical strain in the vadose zone generated during a sinusoidal rate pumping tests to estimate aquifer and/or overburden properties. Pumping tests were performed at a site with a water table at 9 m and saturated saprolite from 9 to 30m depth. Sinusoidal pumping tests in the saprolite used different pumping amplitudes and periods while pressure was measured at three piezometers and vertical strain was measured in the vadose zone from 1 to 7 m depth. The delay time of the pressure increased linearly with distance, and it increased with the square root of the period, while the amplitude of the pressure decreased with distance and increased with amplitude. Vertical strain in the vadose zone varied with the same period as the pumping rate and the delay times were similar to those for pressures measured at similar radial distances. Delay times for the strain increased with an increasing propagation of the strain field. The hydraulic diffusivity was estimated using delay times for pressure and strain, and the results were compared with the values estimated from a constant-rate pumping test. The hydraulic diffusivity from the constant rate test was 0.039 m2/sec, whereas it was 0.053 (±0.05) m2/sec and 0.035 (±0.03) m2/sec from the pressure data and 0.08 (±0.022) m2/sec and 0.035 (±0.001) m2/sec from the strain data from sinusoidal tests of various periods and amplitudes. There is no statistical difference among these values. This study indicates that strain measurements in the vadose zone can be used to estimate aquifer properties during sinusoidal pumping tests.

Blais, Riley↗

Analysis of Liquids Using the Submerged Plasma for Isotopic Detection and Elemental Resolution (SPIDER)

We developed a sensor called the Submerged Plasma for Isotopic Detection and Elemental Resolution (SPIDER) probe, which uses an atmospheric pressure glow discharge below the surface of liquids to excite species in the liquid. Through emission spectroscopy of molten salts, liquid metals, and heavy water, we demonstrated the SPIDER probe’s high resolution, accuracy, and versatility. We successfully identified trace concentrations of transition and rare-earth metals in molten salts and detected the isotopic shift of the H β → D β emission line. Our analysis revealed unconventional spectral alkali line shapes, indicating two competing excitation modes: film explosion and droplet vaporization. The film explosion mode, characterized by dense plasma, exhibited self-reversal and broadband continuum emission, while the droplet vaporization mode, associated with diffusive plasma, produced narrow-line emissions. Furthermore, by analyzing circuit transients alongside individual plasma events, we observed that film explosions generate higher currents, likely due to a shorter plasma length as the current preferentially flows through the thin liquid layer. Altogether, our results highlight the SPIDER probe’s efficacy and flexibility, making it well-suited for online material quantification of liquids in extreme environments.

AES↗

Piezochromic Behavior of 2,4,6-Triphenylpyrylium Tetrachloroferrate

In advanced photonics, there is a growing interest in piezochromic luminescent materials that exhibit multicolor switching, driven by their potential applications in optical recording, memory, and sensors. Here, the piezochromic behavior of 2,4,6-triphenylpyrylium tetrachloroferrate (Py-FeCl 4 ) under high pressures from 0 to 9 GPa is reported. The observed multicolor changing properties of Py-FeCl 4 (yellow–orange–red–maroon–black) are found to be fully reversible upon decompression to ambient conditions. The mechanism of Py-FeCl 4 piezochromism is investigated via Raman, infrared, and UV–vis spectroscopy combined with powder X-ray Diffraction. The absence of structural phase transitions as well as the abrupt shifts of bandgap values together with characteristic Raman and IR peaks within 0-9 GPa suggests that the Py-FeCl 4 multicoloring switching behavior is driven by an electron transfer between the inorganic FeCl 4 – anion and the organic pyrylium cation. The obtained results demonstrate that Py-FeCl 4 dye is a good candidate for developing high-pressure sensing technologies designed to function in extreme environments. Moreover, due to the inherent role of molecular-structure relationships in the pyrylium salt's photophysical properties, findings suggest the potential discovery of piezochromic behavior in other pyrylium compounds.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Skipper CCD Long-Term Vacuum Chamber

The Skipper CCD is a high-sensitivity Charge Coupled Device (CCD) sensor designed at Fermilab that has extremely low readout noise. The Skipper can only be operated at pressures below 10-4Torr (about a millionth of an atmosphere). The purpose of this project was to investigate whether a long-term vacuum chamber could be used for the Skipper CCD, which would require only being re-pumped once a year. This would allow the Skipper to be fully integrated here at Fermilab and then be transported anywhere for immediate use.

Struven, Wolfgang↗

Laser-Induced Breakdown Spectroscopy (LIBS) Sensing for Environmental and Subsurface Monitoring

Groundwater monitoring is essential to timely and accurately reflect the current situations and the trends of water quality. However, the long-term stability and survival of any potential in-situ monitoring method is threatened by the harsh conditions and the groundwater monitoring in downhole environments poses numerous challenges to the sensor community. Laser induced breakdown spectroscopy (LIBS) has been demonstrated as a promising technology for chemical monitoring in high-temperature high-pressure (HTHP) environments and hard to reach places. The technique demonstrates several advantages, such as rapid, real-time, in-situ, and simultaneous detection of multiple elements with simple or no sample preparation. This chapter includes a brief review of the field-portable LIBS systems, and development of a compact, robust, and simple LIBS instrument for downhole HTHP water quality monitoring. The fieldable prototype sensor is tested in an onsite monitoring well where trace elements’ concentrations are tracked over an extended period. The testing has verified that the fiber coupled design performs as desired. The system shows good calibration linearity for tested elements and collection times, and Limits of Detection (LODs) that are comparable to those of tabletop LIBS instruments. In addition to groundwater quality monitoring, the fabricated LIBS-based sensor could have widespread sub-surface detection applications.

Jain, Jinesh [NETL Site Support Contractor, Nation↗

Calcined Polyethyleneimine Coated Optical Fibers for Distributed pH Monitoring at High Pressures and Temperatures

In the oil and gas, CO2 sequestration, H2 subsurface storage, and geothermal energy sectors, subsurface pH measurements are critical for monitoring the geochemical conditions and estimating potential corrosion rates of wellbore systems. Real-time pH measurements in these conditions are vital for detecting and predicting corrosion deterioration of wellbore components that may jeopardize the safety and continued operation of wellbore systems. Building off of earlier TiO2 based pH sensors and the known pH sensitivity of amine-based polymers, a coating based on the secondary amine polymer polyethyleneimine (PEI) was developed. The sensor coating was treated with a high temperature (500 °C) calcination procedure in air to convert it into a more stable oxidized coating capable of withstanding hot aqueous solutions without dissolving while retaining linear pH sensitivity from pH values between 2 and 11. The sensor performance was measured using optical transmission measurements in solutions of various pHs and using optical backscatter reflectometry for distributed pH sensing demonstration in wellbore-relevant pressures (up to 1000 psi) and temperatures (80 °C). A calibration curve with strong differentiation between acidic and alkaline pH was developed for both transmission-based and distributed pH measurements, using fixed wavelength transmission and integrated linear amplitude of backscattered light for distributed measurements.

Shumski, Alexander↗

The Strange Case of Ground-Coupled Airwaves on Seismoacoustic Stations at Local to Near-Regional Scales

Here we investigate the application of ground-coupled airwaves observed by seismoacoustic stations at local to near-regional scales to detect signals of interest and determine back-azimuth information. Ground-coupled airwaves are created from incident pressure waves traveling through the atmosphere that couple to the earth and transmit as a seismic wave with retrograde elliptical motion. Previous studies at sub-local scales (<10 km from a source of interest) found the back-azimuth to the source could be accurately determined from seismoacoustic signals recorded by acoustic and 3-component seismic sensors spatially separated on the order of 10 to 150 m. The potential back-azimuth directions are estimated from the coherent signals between the acoustic and vertical seismic data, via a propagation-induced phase shift of the seismoacoustic signal. A unique solution is then informed by the particle motion of the 3-component seismic station, which was previously found to be less accurate than the seismoacoustic-sensor method. We investigate the applicability of this technique to greater source-receiver distances, from 50-100 km and up to 400 km, which contains pressure waves with tropospheric and stratospheric ray paths, respectively. Specifically, we analyze seismoacoustic sources with ground truth from rocket motor fuel elimination events at the Utah Test and Training Range (UTTR) as well as a 2020 rocket launch in Southern California. From these sources we observe evidence that while coherent signals can be seen from both sources on multiple seismoacoustic station pairs, the determined ground-coupled airwave back-azimuths are more complicated than results at more local scales. Our findings suggest more complex factors including incidence angle, coupling location, subsurface material, and atmospheric propagation effects need to be fully investigated before the ground-coupled airwave back-azimuth determination method can be applied or assessed at these further distances.

58 GEOSCIENCES↗

First Annual Report on Development of Microwave Resonant Cavity Transducer for Fluid Flow Sensing: Development of Sensor Performance Model of Microwave Cavity Flow Meter for Advanced Reactor High Temperature Fluids

We are investigating a microwave cavity-based transducer for in-core high-temperature fluid flow sensing in molten salt cooled reactors (MSCR) and sodium fast reactors (SFR). This sensor is a hollow metallic cylindrical cavity, which can be fabricated from stainless steel, and as such is expected to be resilient to radiation, high temperature and corrosive environment of MSCR and SFR. The principle of sensing consists of making one wall of the cylindrical cavity flexible enough so that dynamic pressure, which is proportional to fluid velocity, will cause membrane deflection. Membrane deflection causes cavity volume change, which leads to a shift in the resonant frequency. Feasibility of the sensor was initially investigated with analytical derivations and with COMSOL RF Module computer simulations of resonant frequency spectral shift due to uniform load. We also investigated the mechanical integrity of the flowmeter’s membrane through analytical modelling and COMSOL Structural Mechanics Module computer simulations. Both the analytic model and COMSOL model showed that maximum stresses on the plate, which are at the radial boundary of the plate, are three orders of magnitude smaller than the material’s yield strength and ultimate tensile strength. This indicates that the sensor is at a low risk of mechanical failure. Using results from models, we have developed an initial design for a microwave K-band sensor. A cylindrical resonator prototype was fabricated from brass for the initial tests. The external dimensions of the cavity are matched to the flange of a standard WR-42 waveguide. Microwave field is coupled into the resonant cavity through a subwavelength-size aperture. A test article was developed consisting of a piping Tee with a bulkhead WR-42 microwave waveguide installed in a leak-proof assembly. A microwave waveguide circulator was installed in the setup to suppress the effect of reflections at the cavity entrance by increasing the isolation between the input and the output port. Preliminary spectral characterization of cavity spectral response was performed with a portable PXIe chassis microwave VNA with a custom GUI. Preliminary dry tests of the transducer response were conducted with a set of calibrated weights. Transducer frequency shift was shown to be monotonically increasing with increasing pressure. The next steps will involve investigation of the transducer performance for water flow sensing.

42 ENGINEERING↗

NPFTURBULENCE: Fast Response Temperature by Airborne Measurements

The original data were collected during the field campaign of the “Turbulent layers promoting New Particle Formation” experiment (NPFTURBULENCE; https://www.arm.gov/research/campaigns/aaf2024npfturbulence; https://www.arm.gov/publications/programdocs/doe-sc-arm-25-004.pdf ) over the Atmospheric Radiation Measurement (ARM) Southern Great Plains (SGP) Atmospheric Observatory (https://www.arm.gov/capabilities/observatories/sgp ) in north-central Oklahoma. The ARM Aerial Facility ArcticShark uncrewed aerial system (UAS, https://www.arm.gov/capabilities/observatories/aaf/uas) was based at Blackwell–Tonkawa Municipal Airport (IATA: BWL, ICAO: KBKN, FAA LID: BKN, 36.74475° N, 97.34918° W, 313.9 m MSL), for the field campaign from May 5 through May 29, 2024. The ArcticShark UAS performed 11 flights, including 10 research flights over the Central Facility of the ARM SGP to measure atmospheric state, turbulence, surface IR temperature and imagery, aerosol number concentration and size distribution. The current dataset presents fast response temperature in the atmospheric boundary layer and lower free troposphere measured on the airborne platform throughout the field campaign. The primary instruments used to create the current dataset were the fine wire thermocouple probe, Pitot-static system (part of the UAS control), and infrared gas analyzer sensor for H2O and CO2 (LI-840A). All parameters used in the temperature calculations (static and dynamic pressure, absolute humidity in form of dew point temperature) were included in the data set. For user convenience, one additional parameter was also included: the type of flight flag (level, up, down, turn, and combination of thereof).

Air temperature↗