Search NASA⌕ Search

SEARCH · Search NASA

Results for “probing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

A heavy ion beam probe system for investigation of a modified Penning discharge

An ion beam probe diagnostic system can measure time- and space-resolved profiles of plasma space potential and electron density. In combination with a computer iterative technique, the ion beam probe can determine both the space potential profile in plasmas containing strong electric fields and potentials comparable in magnitude to the energy of the probing ion beam. During ion beam probing of a modified Penning discharge, several groups of secondary ions were observed coming from the plasma with a fixed primary beam energy and momentum. The energies of these ions were within 10 percent of the values predicted by a computer-generated model of the potential profile in the plasma. The mechanical and electronic components of the system are described, with particular emphasis on those features required to probe plasma potentials comparable in magnitude to the ion beam energy.

Kambic, G. X.↗

Navigation of the 1982 Jupiter Orbiter Probe mission

A new NASA interplanetary flight project, called Jupiter Orbiter Probe (JOP), has been recently approved by Congress. JOP involves a dual mission intended to explore the planet Jupiter and its environment with an atmospheric probe and a planetary orbiter spacecraft. The probe and orbiter vehicles are to be launched in tandem as a single spacecraft during the time from December 1981 to January 1982. The spacecraft will arrive at Jupiter at the earliest on November 14, 1984. Navigating the JOP spacecraft will be a critical task for the JOP mission. Attention is given to aspects of probe and orbiter delivery, Jupiter orbit insertion and perijove raise, the Satellite Tour, navigation development and the navigation system, the probe delivery, example orbits, velocity perturbation and correction, orbit determination characteristics, orbit determination and control profile, and the correction velocity requirements.

Rourke, K. H.↗

The strategy and technique in determining the orbits of the Pioneer Venus multiprobe bus and probes

The Venus Multiprobe Mission presented the greatest degree of complexity for an Orbit Determination task inasmuch as the spacecraft was composed of a bus, a large probe, and three small probes, all of which impacted the planet at various times and locations. In addition, there were eight major maneuvers for the purpose of spacecraft-probe separation and trajectory retargeting. The multiprobe antenna polarization, antenna offset from the spin axis, and spacecraft rotation introduce signatures into the radiometric Doppler data. These signatures, especially in regard to effects seen in Doppler residuals, further increase the complexity of the orbit determination problem. This paper describes the strategy and technique in using this Doppler data to determine the orbits of the multiprobe bus, the large probe, and the three small probes.

Wong, S. K.↗

Theory and calibration of non-nulling seven-hole cone probes for use in complex flow measurement

A seven-hole conical pressure probe capable of measuring flow conditions at angles up to 75 deg relative to its axis is described. The theoretical rationale of the seven-hole probe is developed and the calibration procedure outlined. Three-variable third order polynomials are used to represent local values of total pressure, static pressure, Mach number and relative flow angles. These flow conditions can be determined explicitly from measured probe pressures. Flow angles may be determined within 2.5 deg and Mach number within 0.05 with 95% certainty. The probe was calibrated in subsonic compressible and incompressible flows. Results of a calibration of four seven-hole probes are presented.

Everett, K. N.↗

Anomalous behavior of the Pioneer Venus entry probes during lower descent

Four Pioneer Venus Probe spacecraft entered the Venusian atmosphere on December 9 1978, and descended to the surface while making in situ measurements of chemical composition, structure, and radiative balance. In the lower Venusian atmosphere, a number of anomalous events were noted in some of the scientific instruments and Probe engineering data. Many of these anomalies occurred on each of the Probes at approximately the same altitude. The anomalies are thought to be the result of some unexpected electrical interaction between the Probe and the Venusian atmosphere. This conclusion is based on analysis and testing of similar Probe hardware on the ground. However, the possibility that some anomalies were a result of latent design of manufacturing flaws cannot be ruled out.

Polaski, L. J.↗

Galileo Atmospheric Entry Probe System - Design, development, and test

The overall development of the Galileo Atmospheric Entry Probe System is described. The Probe will be carried to Jupiter by the Galileo Orbiter and released on an entry trajectory 150 days before entry. A complement of seven science instruments will measure the near-Jupiter radiation field and the characteristics of the Jovian atmosphere from a distance of about 5 Jupiter radii above the 1-bar level down to levels in the 10-20-bar range. Probe data are to be transmitted to earth via the Orbiter. System requirements are discussed. Probe design features and those features of the development test program peculiar to entry probes are described.

Givens, J. J.↗

Numerical simulation of a disk-shaped electron accelerating electrostatic probe

This paper presents a method utilizing the numerical plasma simulation particle-in-cell technique for studying electron accelerating probe characteristics. A probe configuration other than the commonly used plane, cylindrical, or spherical case will be studied; the probe configuration used is that of a disk. Cylindrical geometry is used in the simulation model. One of the advantages of a numerical simulation is the ease with which the details of the system can be examined. Therefore, in addition to the current-voltage characteristics of the static probe, other results are presented such as the time evolution of the plasma properties and studies of the sheath region surrounding the probe.

Nonnast, J. H.↗

A new concept for a Titan atmospheric probe

Since the Voyager 1 close-pass observations of Titan, scientific interest in the nature and composition of the atmosphere and surface of Titan has increased greatly. This enhanced interest has led to the study of mission options to the Saturnian system with a principal goal of depositing a probe into the atmosphere of Titan. Such a probe could carry instrumentation to perform in situ measurements of the structure and composition of the atmosphere and clouds and of the morphology and composition of the surface. Previous studies have examined the possibility of modifying, in a minimal way, the Galileo probe currently being prepared for an atmospheric sampling mission to Jupiter. The purpose of this paper is to report the results of a study of probe-system concepts optimized for the Titan mission. The scientific rationale for such a mission to Titan is discussed and instruments to accomplish the scientific goals are indicated. Probe systems compatible with those goals and instruments are described, and the associated development costs for each are discussed.

Swenson, B. L.↗

Titan atmospheric probe

Increased scientific interest in the structure and composition of Titan's atmosphere, clouds and surface have led to the study of mission options to the Saturnian system with the main goal of placing a probe into the atmosphere of the satellite. Two probe concepts have been studied by NASA: the first concept, a slightly modified Galileo probe capable of withstanding approximately 50 earth G during atmospheric entry heating and deceleration, would consist of a blunted 53 degree, 136-cm-diameter half-angle cone with a hemispherical afterbody, and a descent module containing scientific instruments and a parachute; the second concept, a system designed to provide in situ atmospheric measurements of Titan's organic haze layer, would consist of a probe using a 165-cm deployable graphite fabric decelerator, a 50-cm-diameter cylindrical descent module containing five instruments and a 2.5 m-diameter parachute and a 50-cm-radius spherical nose cap. Although the modified Galileo probe is feasible, its scientific drawback includes its inability to obtain in situ measurements above approximately 100 km.

Swenson, B. L.↗

Heat pipe cooled probe

The basic heat pipe principle is employed to provide a self-contained passively cooled probe that may be placed into a high temperature environment. The probe consists of an evaporator region of a heat pipe and a sensing instrument. Heat is absorbed as the working fluid evaporates in the probe. The vapor is transported to the vapor space of the condenser region. Heat is dissipated from the condenser region and fins causing condensation of the working fluid, which returns to the probe by gravity and the capillary action of the wick. Working fluid, wick and condenser configurations and structure materials can be selected to maintain the probe within an acceptable temperature range.

Camarda, C. J.↗

A stagnation pressure probe for droplet-laden air flow

It is often of interest in a droplet-laden gas flow to obtain the stagnation pressure of both the gas phase and the mixture. A flow-decelerating probe (TPF), with separate, purged ports for the gas phase and the mixture and with a bleed for accumulating liquid at the closed end, has been developed. Measurements obtained utilizing the TPF in a nearly isothermal air-water droplet mixture flow in a smooth circular pipe under various conditions of flow velocity, pressure, liquid concentration and droplet size are presented and compared with data obtained under identical conditions with a conventional, gas phase stagnation pressure probe (CSP). The data obtained with the CSP and TPF probes are analyzed to determine the applicability of the two probes in relation to the multi-phase characteristics of the flow and the geometry of the probe.

Murthy, S. N. B.↗

Aerothermodynamic environment for a Titan probe with deployable decelerator

It is pointed out that further exploration of Titan, Saturn's largest moon, is of current interest to the scientific community, particularly from the standpoint of the organic chemical evolution of its atmosphere. For a suitable study of this Saturnian satellite, a mission involving a Titan atmospheric entry probe is to be conducted. The probe is to employ a deployable decelerator with the aim to allow scientific measurements in the haze layer. The present investigation is concerned with an assessment of the aerothermodynamic environment for the considered probe during its hypervelocity, low-Reynolds-number entry. Attention is given to the employed computational method, the Titan probe configuration, the Titan probe trajectory, the viscous-layer regime of the aerothermodynamic environment, and the incipient merged-layer regime.

Green, M. J.↗

Semiautomatic Probe-And-Drogue Attachment Mechanism

Spring-loaded pawls provide quick coupling. As probe enters drogue during coupling, three spring-loaded pawls in probe latch probe in drogue, preventing accidental uncoupling. Then worm-gear mechanism turned by standard 0.25-in. (6.35-mm) tool transfers motion to central threaded shaft, extending cap at tip of probe until all play taken up. This centers probe in drogue and renders coupling pawls to extend again. New mechanism useful for coupling modular components in other applications where ease and security of attachment, precise final alignment, and ease of removal important and where stresses and bending reasonably low.

Wanagas, John D.↗

Technique for temperature compensation of eddy-current proximity probes

Eddy-current proximity probes are used in turbomachinery evaluation testing and operation to measure distances, primarily vibration, deflection, or displacment of shafts, bearings and seals. Measurements of steady-state conditions made with standard eddy-current proximity probes are susceptible to error caused by temperature variations during normal operation of the component under investigation. Errors resulting from temperature effects for the specific probes used in this study were approximately 1.016 x 10 to the -3 mm/deg C over the temperature range of -252 to 100 C. This report examines temperature caused changes on the eddy-current proximity probe measurement system, establishes their origin, and discusses what may be done to minimize their effect on the output signal. In addition, recommendations are made for the installation and operation of the electronic components associated with an eddy-current proximity probe. Several techniques are described that provide active on-line error compensation for over 95 percent of the temperature effects.

Masters, Robert M.↗

Miniaturized compact water-cooled pitot-pressure probe for flow-field surveys in hypersonic wind tunnels

An experimental investigation of the design of pitot probes for flowfield surveys in hypersonic wind tunnels is reported. The results show that a pitot-pressure probe can be miniaturized for minimum interference effects by locating the transducer in the probe support body and water-cooling it so that the pressure-settling time and transducer temperature are compatible with hypersonic tunnel operation and flow conditions. Flowfield surveys around a two-to-one elliptical cone model in a 20-inch Mach 6 wind tunnel using such a probe show that probe interference effects are essentially eliminated.

Ashby, George C.↗

Circumferential pressure probe

A probe for measuring circumferential pressure inside a body cavity is disclosed. In the preferred embodiment, a urodynamic pressure measurement probe for evaluating human urinary sphincter function is disclosed. Along the length of the probe are disposed a multiplicity of deformable wall sensors which typically comprise support tube sections with flexible side wall areas. These are arranged along the length of the probe in two areas, one just proximal to the tip for the sensing of fluid pressure inside the bladder, and five in the sensing section which is positioned within the urethra at the point at which the urinary sphincter constricts to control the flow of urine. The remainder of the length of the probe comprises multiple rigid support tube sections interspersed with flexible support tube sections in the form of bellows to provide flexibility.

Holmes, Harlan K.↗

The application of the triple probe method to MPD thruster plumes

The triple probe method is an attractive technique for measuring axial and radial profiles of electron temperature T(e) and electron number density n(e) in magnetoplasmadynamic (MPD) thruster plumes. In this paper the performance and applicability of the triple probe to MPD thruster plumes is evaluated by identifying sources of error, correction methods, and error estimation techniques. Included in the analysis is an adaptation of Laframboise's exact calculations to the triple probe, aligned with the flow vector, and a preliminary investigation of the effect of flow transverse to the probe axis. In MPD thrusters, the triple probe method can provide measurement accuracy of T(e) wintin about 10 percent and n(e) within about 60 percent.

Kelly, Arnold J.↗

Evaluation of water cooled supersonic temperature and pressure probes for application to 1366 K flows

Water cooled supersonic probes are developed to investigate total pressure, static pressure, and total temperature in high-temperature jet plumes and thereby determine the mean flow properties. Two probe concepts, designed for operation at up to 1366 K in a Mach 2 flow, are tested on a water cooled nozzle. The two probe designs - the unsymmetric four-tube cooling configuration and the symmetric annular cooling design - take measurements at 755, 1089, and 1366 K of the three parameters. The cooled total and static pressure readings are found to agree with previous test results with uncooled configurations. The total-temperature probe, however, is affected by the introduction of water coolant, and effect which is explained by the increased heat transfer across the thermocouple-bead surface. Further investigation of the effect of coolant on the temperature probe is proposed to mitigate the effect and calculate more accurate temperatures in jet plumes.

Lagen, Nicholas↗