Search NASA⌕ Search

SEARCH · Search NASA

Results for “protocol technology”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Opportunities for Simultaneous Efficiency Improvement and Refrigerant Transition in Air Conditioning

In October of 2016, nearly 200 Parties agreed to amend the Montreal Protocol in Kigali, Rwanda, to phase-down consumption and production of hydrofluorocarbons (HFCs) by 2050. Growth in the use of HFCs, including those currently used as refrigerants in air-conditioning systems, is being driven by demand from emerging economies, hot climates, and rising incomes that are also undergoing rapid urbanization and electrification. Air conditioners (ACs), as an energy-intensive end-use technology, are also covered by a growing number of energy efficiency standards, labeling, procurement, incentive, and other supporting efficiency programs. Therefore, improving room AC energy efficiency and transitioning to low-global warming potential (GWP) refrigerants simultaneously presents significant opportunities to deploy energy efficient technology and reduce the energy and emissions impacts of room ACs, while keeping costs low for consumers. This report aims to provide an initial sense of the opportunities to improve efficiency and transition to low-GWP refrigerants by reviewing the HCFC and HFC regulatory framework and energy efficiency standards and labeling programs in 19 economies that account for roughly 65 percent of global room AC demand. Based on this analysis, we identified key opportunities for coordinated action on efficiency improvement and refrigerant transition for the domestic room AC sector (i.e., ductless mini-split ACs), such as: - implementing or revising standards and labeling programs to improve efficiency levels with the possibility of adding a low-GWP criterion. - combining fixed speed and inverter AC product categories to account for seasonal variations in climate and part-load operating conditions, and using seasonal energy efficiency ratio (SEER) instead of energy efficiency ratio (EER) to better reflect performance of inverter ACs. - implementing market transformation programs, such as bulk procurement programs, to drive down the costs of efficient technology through economies of scale. - aligning timelines for implementing efficiency standards with timelines for refrigerant management plans to coordinate policy actions. - maximizing the energy efficiency improvements of Montreal Protocol investments by coordinating efforts to help keep costs low for consumers and manufacturers during equipment redesign and manufacturing line retooling for refrigerant transition. In order to realize the significant peak load, energy saving and climate benefits of these opportunities associated with improving energy efficiency in tandem with the refrigerant transition, some risks may need to be mitigated, principally safety concerns over risks of accidental ignition with refrigerants rated flammable. This can be mitigated by continuing and accelerating the development of safety standards currently being updated, for example, by the International Electrotechnical Commission (IEC) and improving training for production, installation and maintenance during the use of flammable refrigerants. While some low-GWP refrigerants may cost more than the current baseline refrigerants, the cost of refrigerants is only ~1% of lifecycle costs for an AC. Costs can also be reduced through manufacturing advances and efficiency improvements, particularly if they are supported by policies that encourage technological development through deployment of superefficient ACs at scale. Finally, during the transition, there is a risk of obsolete technology being deployed in markets that either have not updated their standards or have later compliance dates. This risk can be mitigated by updating standards and reviewing them periodically to ensure their effectiveness.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Deep Learning for Spectral Filling in Radio Frequency Applications

Due to the Internet of Things (IoT) proliferation, Radio Frequency (RF) channels are increasingly congested with new kinds of devices, which carry unique and diverse communication needs. This poses complex challenges in modern digital communications, and calls for the development of technological innovations that (i) optimize capacity (bitrate) in limited bandwidth environments, (ii) integrate cooperatively with already-deployed RF protocols, and (iii) are adaptive to the ever-changing demands in modern digital communications. In this paper we present methods for applying deep neural networks for spectral filling. Given an RF channel transmitting digital messages with a pre-established modulation scheme, we automatically learn novel modulation schemes for sending extra information, in the form of additional messages, “around” the fixed-modulation signals (i.e., without interfering with them). In so doing, we effectively increase channel capacity without increasing bandwidth. We further demonstrate the ability to generate signals that closely resemble the original modulations, such that the presence of extra messages is undetectable to third-party listeners. We present three computational experiments demonstrating the efficacy of our methods, and conclude by discussing the implications of our results for modern RF applications.

Setzler, Matthew D.↗

MO-G-18A-01: Radiation Dose Reducing Strategies in CT, Fluoroscopy and Radiography

Advances in medical x-ray imaging have provided significant benefits to patient care. According to NCRP 160, there are more than 400 million x-ray procedures performed annually in the United States alone that contributes to nearly half of all the radiation exposure to the US population. Similar growth trends in medical x-ray imaging are observed worldwide. Apparent increase in number of medical x-ray imaging procedures, new protocols and the associated radiation dose and risk has drawn considerable attention. This has led to a number of technological innovations such as tube current modulation, iterative reconstruction algorithms, dose alerts, dose displays, flat panel digital detectors, high efficient digital detectors, storage phosphor radiography, variable filters, etc. that are enabling users to acquire medical x-ray images at a much lower radiation dose. Along with these, there are number of radiation dose optimization strategies that users can adapt to effectively lower radiation dose in medical x-ray procedures. The main objectives of this SAM course are to provide information and how to implement the various radiation dose optimization strategies in CT, Fluoroscopy and Radiography. Learning Objectives: To update impact of technological advances on dose optimization in medical imaging. To identify radiation optimization strategies in computed tomography. To describe strategies for configuring fluoroscopic equipment that yields optimal images at reasonable radiation dose. To assess ways to configure digital radiography systems and recommend ways to improve image quality at optimal dose.

60 APPLIED LIFE SCIENCES↗

MO-FG-207-00: Technological Advances in PET/MR Imaging

The use of integrated PET/MRI systems in clinical applications can best benefit from understanding their technological advances and limitations. The currently available clinical PET/MRI systems have their own characteristics. Thorough analyses of existing technical data and evaluation of necessary performance metrics for quality assurances could be conducted to optimize application-specific PET/MRI protocols. This Symposium will focus on technical advances and limitations of clinical PET/MRI systems, and how this exciting imaging modality can be utilized in applications that can benefit from both PET and MRI. Learning Objectives: To understand the technological advances of clinical PET/MRI systems To correctly identify clinical applications that can benefit from PET/MRI To understand ongoing work to further improve the current PET/MRI technology Floris Jansen is a GE Healthcare employee.

60 APPLIED LIFE SCIENCES↗

MO-FG-207-01: Technological Advances and Challenges: Experience with the First Integrated Whole-Body PET/MRI

The use of integrated PET/MRI systems in clinical applications can best benefit from understanding their technological advances and limitations. The currently available clinical PET/MRI systems have their own characteristics. Thorough analyses of existing technical data and evaluation of necessary performance metrics for quality assurances could be conducted to optimize application-specific PET/MRI protocols. This Symposium will focus on technical advances and limitations of clinical PET/MRI systems, and how this exciting imaging modality can be utilized in applications that can benefit from both PET and MRI. Learning Objectives: To understand the technological advances of clinical PET/MRI systems To correctly identify clinical applications that can benefit from PET/MRI To understand ongoing work to further improve the current PET/MRI technology Floris Jansen is a GE Healthcare employee.

60 APPLIED LIFE SCIENCES↗

MO-FG-207-02: Technological Advances and Challenges: Experience with Time-Of-Flight PET Combined with 3-Tesla MRI

The use of integrated PET/MRI systems in clinical applications can best benefit from understanding their technological advances and limitations. The currently available clinical PET/MRI systems have their own characteristics. Thorough analyses of existing technical data and evaluation of necessary performance metrics for quality assurances could be conducted to optimize application-specific PET/MRI protocols. This Symposium will focus on technical advances and limitations of clinical PET/MRI systems, and how this exciting imaging modality can be utilized in applications that can benefit from both PET and MRI. Learning Objectives: To understand the technological advances of clinical PET/MRI systems To correctly identify clinical applications that can benefit from PET/MRI To understand ongoing work to further improve the current PET/MRI technology Floris Jansen is a GE Healthcare employee.

60 APPLIED LIFE SCIENCES↗

MO-FG-207-03: Maximizing the Utility of Integrated PET/MRI in Clinical Applications

The use of integrated PET/MRI systems in clinical applications can best benefit from understanding their technological advances and limitations. The currently available clinical PET/MRI systems have their own characteristics. Thorough analyses of existing technical data and evaluation of necessary performance metrics for quality assurances could be conducted to optimize application-specific PET/MRI protocols. This Symposium will focus on technical advances and limitations of clinical PET/MRI systems, and how this exciting imaging modality can be utilized in applications that can benefit from both PET and MRI. Learning Objectives: To understand the technological advances of clinical PET/MRI systems To correctly identify clinical applications that can benefit from PET/MRI To understand ongoing work to further improve the current PET/MRI technology Floris Jansen is a GE Healthcare employee.

60 APPLIED LIFE SCIENCES↗

WE-A-BRC-00: The Quality Gap

Quality and safety in healthcare are inextricably linked. There are compelling data that link poor quality radiation therapy to inferior patient survival. Radiation Oncology clinical trial protocol deviations often involve incorrect target volume delineation or dosing, akin to radiotherapy incidents which also often involve partial geometric miss or improper radiation dosing. When patients with radiation protocol variations are compared to those without significant protocol variations, clinical outcome is negatively impacted. Traditionally, quality assurance in radiation oncology has been driven largely by new technological advances, and safety improvement has been driven by reactive responses to past system failures and prescriptive mandates recommended by professional organizations and promulgated by regulators. Prescriptive approaches to quality and safety alone often do not address the huge variety of process and technique used in radiation oncology. Risk-based assessments of radiotherapy processes provide a mechanism to enhance quality and safety, both for new and for established techniques. It is imperative that we explore such a paradigm shift at this time, when expectations from patients as well as providers are rising while available resources are falling. There is much we can learn from our past experiences to be applied towards the new risk-based assessments. Learning Objectives: Understand the impact of clinical and technical quality on outcomes Understand the importance of quality care in radiation oncology Learn to assess the impact of quality on clinical outcomes D. Followill, NIH Grant CA180803.

60 APPLIED LIFE SCIENCES↗

WE-A-BRC-01: Introduction to the Certificate Course

Quality and safety in healthcare are inextricably linked. There are compelling data that link poor quality radiation therapy to inferior patient survival. Radiation Oncology clinical trial protocol deviations often involve incorrect target volume delineation or dosing, akin to radiotherapy incidents which also often involve partial geometric miss or improper radiation dosing. When patients with radiation protocol variations are compared to those without significant protocol variations, clinical outcome is negatively impacted. Traditionally, quality assurance in radiation oncology has been driven largely by new technological advances, and safety improvement has been driven by reactive responses to past system failures and prescriptive mandates recommended by professional organizations and promulgated by regulators. Prescriptive approaches to quality and safety alone often do not address the huge variety of process and technique used in radiation oncology. Risk-based assessments of radiotherapy processes provide a mechanism to enhance quality and safety, both for new and for established techniques. It is imperative that we explore such a paradigm shift at this time, when expectations from patients as well as providers are rising while available resources are falling. There is much we can learn from our past experiences to be applied towards the new risk-based assessments. Learning Objectives: Understand the impact of clinical and technical quality on outcomes Understand the importance of quality care in radiation oncology Learn to assess the impact of quality on clinical outcomes D. Followill, NIH Grant CA180803.

60 APPLIED LIFE SCIENCES↗

WE-A-BRC-02: Lessons Learned: Clinical Trials and Operations

Quality and safety in healthcare are inextricably linked. There are compelling data that link poor quality radiation therapy to inferior patient survival. Radiation Oncology clinical trial protocol deviations often involve incorrect target volume delineation or dosing, akin to radiotherapy incidents which also often involve partial geometric miss or improper radiation dosing. When patients with radiation protocol variations are compared to those without significant protocol variations, clinical outcome is negatively impacted. Traditionally, quality assurance in radiation oncology has been driven largely by new technological advances, and safety improvement has been driven by reactive responses to past system failures and prescriptive mandates recommended by professional organizations and promulgated by regulators. Prescriptive approaches to quality and safety alone often do not address the huge variety of process and technique used in radiation oncology. Risk-based assessments of radiotherapy processes provide a mechanism to enhance quality and safety, both for new and for established techniques. It is imperative that we explore such a paradigm shift at this time, when expectations from patients as well as providers are rising while available resources are falling. There is much we can learn from our past experiences to be applied towards the new risk-based assessments. Learning Objectives: Understand the impact of clinical and technical quality on outcomes Understand the importance of quality care in radiation oncology Learn to assess the impact of quality on clinical outcomes D. Followill, NIH Grant CA180803.

60 APPLIED LIFE SCIENCES↗

WE-A-BRC-03: Lessons Learned: IROC Audits

Quality and safety in healthcare are inextricably linked. There are compelling data that link poor quality radiation therapy to inferior patient survival. Radiation Oncology clinical trial protocol deviations often involve incorrect target volume delineation or dosing, akin to radiotherapy incidents which also often involve partial geometric miss or improper radiation dosing. When patients with radiation protocol variations are compared to those without significant protocol variations, clinical outcome is negatively impacted. Traditionally, quality assurance in radiation oncology has been driven largely by new technological advances, and safety improvement has been driven by reactive responses to past system failures and prescriptive mandates recommended by professional organizations and promulgated by regulators. Prescriptive approaches to quality and safety alone often do not address the huge variety of process and technique used in radiation oncology. Risk-based assessments of radiotherapy processes provide a mechanism to enhance quality and safety, both for new and for established techniques. It is imperative that we explore such a paradigm shift at this time, when expectations from patients as well as providers are rising while available resources are falling. There is much we can learn from our past experiences to be applied towards the new risk-based assessments. Learning Objectives: Understand the impact of clinical and technical quality on outcomes Understand the importance of quality care in radiation oncology Learn to assess the impact of quality on clinical outcomes D. Followill, NIH Grant CA180803.

60 APPLIED LIFE SCIENCES↗

A Novel Sensor Platform Matching the Improved Version of IPMVP Option C for Measuring Energy Savings

It is easy to measure energy consumption with a power meter. However, energy savings cannot be directly computed by the powers measured using existing power meter technologies, since the power consumption only reflects parts of the real energy flows. The International Performance Measurement and Verification Protocol (IPMVP) was proposed by the Efficiency Valuation Organization (EVO) to quantify energy savings using four different methodologies of A, B, C and D. Although energy savings can be estimated following the IPMVP, there are limitations on its practical implementation. Moreover, the data processing methods of the four IPMVP alternatives use multiple sensors (thermometer, hygrometer, Occupant information) and power meter readings to simulate all facilities, in order to determine an energy usage benchmark and the energy savings. This study proposes a simple sensor platform to measure energy savings. Using usually the Electronic Product Code (EPC) global standard, an architecture framework for an information system is constructed that integrates sensors data, power meter readings and occupancy conditions. The proposed sensor platform is used to monitor a building with a newly built vertical garden system (VGS). A VGS shields solar radiation and saves on energy that would be expended on air-conditioning. With this platform, the amount of energy saved in the whole facility is measured and reported in real-time. The data are compared with those obtained from detailed measurement and verification (M&V) processes. The discrepancy is less than 1.565%. Using measurements from the proposed sensor platform, the energy savings for the entire facility are quantified, with a resolution of ±1.2%. The VGS gives an 8.483% daily electricity saving for the building. Thus, the results show that the simple sensor platform proposed by this study is more widely applicable than the four complicated IPMVP alternatives and the VGS is an effective tool in reducing the carbon footprint of a building.

vertical garden system (VGS)↗

Mapping of Benthic Habitats at Marine Renewable Energy Sites Using Multibeam Echosounder and Sediment Profile Imaging Technologies

Objectives/Scope: The goal of this work was to develop a consistent and semi-automated seafloor survey method for generating high-resolution, benthic habitat maps for environmental assessments and monitoring of marine renewable energy sites. Sediment profile and plan view imaging (SPI/PV) technology was combined with multibeam bathymetry and acoustic backscatter methods to demonstrate a rapid, cost-effective benthic mapping protocol. A key technical innovation of this project was the development of an image processing platform that automatically measures key features from the images. Methods: Multibeam echosounder (MBES) acoustic and SPI/PV surveys were conducted at three coastal areas off the U.S. west coast, including the PacWave South energy test site off of Newport, Oregon. Point data on physical and biological sediment conditions obtained from the SPI/PV imagery were used to efficiently ground-truth the high-resolution MBES bathymetry and backscatter mosaics. The SPI camera is an optical corer that obtains an undisturbed 21 by 15 cm, high-resolution, cross-sectional image of the sediment–water interface and upper sediment column. The plan view camera attached to the SPI camera frame captures a downward looking view of the seabed immediately before the SPI image is obtained. As part of this project, we developed a computer vision image processing platform (iSPI) that uses deep convolutional neural networks and other approaches to automatically identify and measure key features in the images, such as grain size and surface relief. Results: Detailed benthic habitat maps were generated using this mapping approach for three different marine settings. The sites mapped included a silt-dominated embayment; a sloping, nearshore, transitional very fine to coarse sand bottom; and a medium, sand-dominated continental shelf marine energy test site. In each case, acoustic and imaging surveys were completed in less than week, and detailed benthic habitat maps were generated within 60 days. The results were placed within the Coastal and Marine Ecological Classification Standard (CMECS) habitat mapping framework, and various combinations of the bathymetry, backscatter, and SPI and PV data were used to generate CMECS component maps. Novel Information: This project developed and demonstrated a repeatable and cost-effective approach for efficiently mapping benthic habitat conditions over broad areas of the seafloor by combining state-of-the-art acoustic and imaging techniques. The primary survey tools used in this project have been used previously in both the offshore renewable (wind) and oil and gas sectors to map and monitor benthic environments. This project’s innovations include 1) the focused use of high-resolution SPI/PV imagery to ground-truth acoustic mosaics, and 2) the development of a computer automated image analysis processing tool that both streamlines and standardizes the generation of data from the imagery and makes the data extraction process more cost-effective and repeatable.

13 HYDRO ENERGY↗

Multiqubit entanglement generation with squeezed modes

We present a hybrid continuous variable–discrete variable entanglement generation protocol using linear optics and homodyne measurements, capable of producing multiple high-fidelity Bell pairs per protocol iteration, with an approximate 0.5 success probability. The effectiveness of the protocol is determined by the squeezing strength. To increase the number of Bell pairs, approximately 3 dB of extra squeezing is needed for each additional Bell pair. The protocol also generates single Bell pairs with an approximate 0.75 probability for squeezing strengths ⪅ 15 dB , achievable with current technology.

Macridin, Alexandru [Fermilab] (ORCID:000000022228↗

Enterprise SRS: Leveraging Ongoing Operations To Advance Nuclear Fuel Cycles Research And Development Programs

The Savannah River Site (SRS) is repurposing its vast array of assets to solve future national issues regarding environmental stewardship, national security, and clean energy. The vehicle for this transformation is Enterprise SRS which presents a new, radical view of SRS as a united endeavor for ''all things nuclear'' as opposed to a group of distinct and separate entities with individual missions and organizations. Key among the Enterprise SRS strategic initiatives is the integration of research into facilities in conjunction with on-going missions to provide researchers from other national laboratories, academic institutions, and commercial entities the opportunity to demonstrate their technologies in a relevant environment and scale prior to deployment. To manage that integration of research demonstrations into site facilities, The Department of Energy, Savannah River Operations Office, Savannah River Nuclear Solutions, the Savannah River National Laboratory (SRNL) have established a center for applied nuclear materials processing and engineering research (hereafter referred to as the Center). The key proposition of this initiative is to bridge the gap between promising transformational nuclear fuel cycle processing discoveries and large commercial-scale-technology deployment by leveraging SRS assets as facilities for those critical engineering-scale demonstrations necessary to assure the successful deployment of new technologies. The Center will coordinate the demonstration of R&D technologies and serve as the interface between the engineering-scale demonstration and the R&D programs, essentially providing cradle-to-grave support to the research team during the demonstration. While the initial focus of the Center will be on the effective use of SRS assets for these demonstrations, the Center also will work with research teams to identify opportunities to perform research demonstrations at other facilities. Unique to this approach is the fact that these SRS assets will continue to accomplish DOE's critical nuclear material missions (e.g., processing in H-Canyon and plutonium storage in K-Area). Thus, the demonstration can be accomplished by leveraging the incremental cost of performing demonstrations without needing to cover the full operational cost of the facility. Current Center activities have been focused on integrating advanced safeguards monitoring technologies demonstrations into the SRS H-Canyon and advanced location technologies demonstrations into K-Area Materials Storage. These demonstrations are providing valuable information to researchers and customers as well as providing the Center with an improved protocol for demonstration management that can be exercised across the entire SRS (as well as to offsite venues) so that future demonstrations can be done more efficiently and provide an opportunity to utilize these unique assets for multiple purposes involving national laboratories, academia, and commercial entities. Key among the envisioned future demonstrations is the use of H-Canyon to demonstrate new nuclear materials separations technologies critical for advancing the mission needs DOE-Nuclear Energy (DOE-NE) to advance the research for next generation fuel cycle technologies. The concept is to install processing equipment on frames. The frames are then positioned into an H-Canyon cell and testing in a relevant radiological environment involving prototypic radioactive materials can be performed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Application of the NREL Test-to-Failure Protocol for PV Modules

Initial results of application of the NREL Test-to-Failure Protocol are presented and discussed. Six commercially available multicrystalline Si-cell flat-plate modules were subjected to the protocol with controls. The samples were divided among three test sequences, (1) 1000 hours of 85C/85% relative humidity with positive or negative 600 V bias to the active layers with respect to the grounded frame, (2) -40/85C thermal cycling with electrical load at the rated module power, and (3) an alternating sequence between tests (1) and (2). Application of the protocol manifested in the acceleration of degradation mechanisms seen in the field including backsheet delamination, corrosion, bubble formation within the laminate, discoloration of the antireflective coating, and localized heating with degradation of the backsheet as a result of moisture ingress, corrosion, and concentrated current flow. Significant differences in performance after one round of the protocol are seen in damp heat depending on the polarity of the bias applied to the active layer (the short-circuited power leads of the module). The protocol is found to successfully accelerate module degradation mechanisms that have been observed in the field and will help to differentiate the performance and reliability of various module technologies.

14 SOLAR ENERGY↗

PV Cyber Security Research (Final Report)

Extensive deployment of interoperable distributed energy resources (DER) on power systems is increasing the power system cyber security attack surface. National and jurisdictional interconnection standards require DER to include a range of autonomous and commanded grid support functions which can drastically influence power quality, voltage, and bulk system frequency. This project was split into two phases. The first provided a survey and roadmap of the cybersecurity for the solar industry. The second investigated multiple PV cybersecurity research and development (R&D) concepts identified in the first phase. In the first year, the team created a roadmap for improving cybersecurity for distributed solar energy resources. This roadmap was intended to provide direction for the nation over the next five years and focused on the intersection of industry and government and recommends activities in four related areas: stakeholder engagement, cyber security research and development, standards development, and industry best practices. At the same time, the team produced a primer for DER vendors, aggregators, and grid operators to establish a common taxonomy and describe basic principles of cyber security, encryption, communication protocols, DER cyber security recommendations and requirements, and device-, aggregator-, and utility-level security best practices to ensure data confidentiality, integrity, and availability. This material was motivated by the need to assist the broader PV industry with cybersecurity resilience and describe the state-of-the-art for securing DER communications. Lastly, an adversary-based assessment of multiple PV devices was completed at the Distributed Energy Technologies Laboratory at Sandia National Laboratories to determine the status of industry cybersecurity practices. The team found multiple deficiencies in the security features of the assessed devices. In the second year, a set of recommendations was created for DER communication protocols— especially with respect to the state-of-the-art requirements in IEEE 2030.5. Additionally, several cybersecurity R&D technologies related to communications-enabled photovoltaic systems were studied to harden DER communication networks. Specifically, the team investigated (a) using software defined networking to create a moving target defense system for DER communications, and (b) engineering controls that prevent misprogramming or adversary action on DER devices/networks by disallowing setpoints that will generate unstable power system operations.

14 SOLAR ENERGY↗

Reliable Power Rating of Perovskite PV Modules

As the perovskite technology is ramping up into commercialization, reliable and accurate power rating of large-size perovskite modules becomes a prominent aspect for its future deployment in the PV market. It is known that the performance calibration of perovskite PV devices is very challenging due to its complex dynamic response during a conventional current-voltage (IV) measurement. PV researchers have previously proposed several steady-state performance calibration methods to reliably extract PV efficiencies, but mostly focus on small area research-type cells. In this paper, we emphasize the importance of reliable performance calibration on large-size perovskite modules. Extending the NREL Cell and Module Performance (CMP) group's steady-state performance calibration protocol (i.e., Asymptotic P MAX Scan) for perovskite cells to modules, we justify the necessity of reporting steady-state efficiencies for perovskite cells and discuss the challenges of applying this protocol to modules. We also present our protocol for Maximum Power Point Tracking (MPPT), which is a technique often used for performance calibration of perovskite cells and modules, and show a comparison between MPPT and Asymptotic P MAX . Using MPPT we demonstrate the interplay between metastability and degradation in perovskite modules, and emphasize the necessity to develop preconditioning protocols for stabilizing these devices. Our aim is to promote development of consensus protocols for performance calibration of perovskite modules, and to advance their credible power ratings, which will be beneficial to the growth of perovskite technology in the PV market.

perovskite↗