Microwave Remote Sensing Of Meteorological Quantities

Report discusses remote sensing of fluxes of heat and moisture occurring in exchange of energy, via turbulence and radiation, between ocean and atmosphere by microwave radiometers in orbit around Earth. Discusses satellite-borne microwave sensors and need to design sensors for optimal synergism with respect to determination of vertical structures of fluxes of moisture and heat at shorter time scales.

Liu, Wing-Yuen T.↗

Feasibility study of a low-energy gamma ray system for measuring quantity and flow rate of slush hydrogen

As part of a study to demonstrate the suitability of an X-ray or gamma ray probe for monitoring the quality and flow rate of slush hydrogen, mass attenuation coefficients for Cd-109 X- and gamma radiation in five chemical compounds were measured. The Ag-109 K rays were used for water and acetic acid, whereas E3 transition from the first excited state at 87.7 keV in Ag-109 provided the probe radiation for bromobenzene, alpha (exp 2) chloroisodurene, and cetyl bromide. Measurements were made for a single phase (gas, liquid, solid) as well as mixed phases (liquid plus solid) in all cases. It was shown that the mass attenuation coefficient for the selected radiations is independent of the phase of the test fluids or phase ratios in the case of mixed phase fluids. Described here are the procedure and the results for the five fluid systems investigated.

Singh, Jag J.↗

Modeling ice streams: Derived quantities

The model addressed is a finite-element, map-plane, time-dependent, column-averaged continuity equation solver. The key to the fitting process involves the balance between ice motion dominated by flow in internal layers, and ice motion dominated by sliding at the bed. The fitting process involves an iterative process carried out in the time domain. Beginning with the portion of the ice sheet being modeled identical to the present ice sheet with uniform flow, sliding, and fraction specified at nominal values, the model monitors each nodal point surface elevation. As the calculated surface elevation deviates from the present surface, a correction proportional to the difference is applied to selected parameter sets. This correction is in a sense that would tend to improve the fit at the particular nodal point. A calculated surface elevation that was higher than the present surface would result in an increased fraction, which would tend to lower the calculated surface (if the flow or sliding constant were being used as the fitting parameter, they would be lowered to improve the fit). This process is allowed to proceed as long as is necessary for the situation to stabilize. Typically, this takes tens of thousands of model years, but the rate is dependent on other external forcings such as the accumulation rate. The primary result is that while a typical sample of ice streams from around Antarctica can be fitted quite reasonably using only the fraction of the velocity due to sliding, a different mechanism seems to be in play along the Siple Coast, where reduced sliding constants are required to attain a reasonable fit. Flow is more strongly channelized in this region, and velocities are, in general, higher than are observed in other regions. It is unlikely that the mechanism that controls the ice movement along the Siple Coast is exactly similar to the mechanisms in the other ice streams. The concept of deformable sediments and their contribution to the fast flow along the Siple Coast may have limited applicability to other Antarctic ice streams.

Fastook, James↗

Calculation of surface and top of atmosphere radiative fluxes from physical quantities based on ISCCP data sets. 2: Validation and first results

We use global, multiyear observations of the properties of clouds, the atmosphere, and the surface to calculate global shortwave (SW) and longwave (LW) fluxes at the top of the atmosphere and at the surface at a resolution of 280 km and 3 hours for every third month from April 1985 to January 1989. Our validation studies suggest that the specification of cloud effects is no longer the dominant uncertainty in reconstructing the radiative fluxes at the top of atmosphere and at the surface. Rather cloud property uncertainties are now roughly equal contributors to the flux uncertainty, along with surface and atmospheric properties. The resulting SW and LW flux data sets suggest the following conclusions: (1) The net SW heating of Earth appears predominantly at the surface, whereas the net LW cooling arises predominantly from the atmosphere. The net cooling effect of clouds on top of atmospheric radiation appears primarily at the surface rather than in the atmosphere. (2) Clouds have almost no net effect on the global mean radiation balance of the atmosphere, but they enhance the latitudinal gradient in the LW cooling and reinforce the radiative forcing for the mean atmospheric circulation. Clouds act to mute seasonal contrasts however. (3) Clouds enhance the land-ocean contrasts of the atmospheric cooling, reinforcing the growth of standing eddy motions; but reduce land-ocean contrasts of the surface heating.

Rossow, W. B.↗

Effects of Subsurface Sampling & Processing on Martian Simulant Containing Varying Quantities of Water

The presence of water-ice in the Martian subsurface is a subject of much debate and excited speculation. Recent results from the gammaray spectrometer (GRS) on board NASA's Mars Odyssey spacecraft indicate the presence of large amounts of hydrogen in regions of predicted ice stability. The combination of chemistry, low gravitational field (3.71 m/s(exp 2)) and a surface pressure of about 6.36 mbar at the mean radius, place limits on the stability of H2O on the surface, however, results from the GRS indicate that the hydrogen rich phase may be present at a depth as shallow as one meter in some locations on Mars. The potential for water on Mars leads directly to the speculation that life may once have existed there, since liquid water is the unifying factor for environments known to support life on Earth. Lubricant-free drilling has been considered as a means of obtaining water-rich subsurface samples on Mars, and two recent white papers sponsored by the Mars Program have attempted to identify the problems associated with this goal. The two major issues identified were: the engineering challenges of drilling into a water-soil mixture where phase changes may occur; and the potential to compromise the integrity of in-situ scientific analysis due to contamination, volatilization, and mineralogical or chemical changes as a result of processing. This study is a first attempt to simulate lubricantfree drilling into JSC Mars-1 simulant containing up to 50% water by weight. The goal is to address the following: 1) Does sample processing cause reactions or changes in mineralogy which will compromise the interpretation of scientific measurements conducted on the surface? 2) Does the presence of water-ice in the sample complicate (1)? 3) Do lubricant-free drilling and processing leave trace contaminants which may compromise our understanding of sample composition? 4) How does the torque/power required for drilling change as a function of water content and does this lead to unexpected thermal effects?

Menard, J.↗

Analysis of mutant quantity and quality in human-hamster hybrid AL and AL-179 cells exposed to 137Cs-gamma or HZE-Fe ions

We measured the number of mutants and the kinds of mutations induced by 137Cs-gamma and by HZE-Fe (56Fe [600 MeV/amu, LET = 190 KeV/micrometer) in standard AL human hamster hybrid cells and in a new variant hybrid, AL-179. We found that HZE-Fe was more mutagenic than 137Cs-gamma per unit dose (about 1.6 fold), but was slightly less mutagenic per mean lethal dose, DO, at both the S1 and hprt- loci of AL cells. On the other hand, HZE-Fe induced about nine fold more complex S1- mutants than 137Cs-gamma rays, 28% vs 3%. 137Cs-gamma rays induced about twice as many S1- mutants and hprt-mutants in AL-179 as in AL cells, and about nine times more of the former were complex, and potentially unstable kinds of mutations.

NASA Discipline Radiation Health↗

On-line technique for measuring stable oxygen and hydrogen isotopes from microliter quantities of water

Detailed here is a method for extracting and analyzing oxygen and hydrogen isotopes from 10 microL-sized water samples. Based on the traditional CO2-H2O equilibration technique, the oxygen isotope exchange reaction is done exclusively in sealed 6-mm (o.d.) Pyrex tubes at 25 degrees C, with full isotope exchange completed in at least 28 h. Using the same water sample employed in the 18O equilibration, D/H extractions are done in separate sealed 6-mm (o.d.) Pyrex tubes by reaction with Zn at 450 degrees C to form H2(g). Provided that a correction factor is applied to 18O analyses, accuracy and precision for both 18O and D/H are comparable to standard techniques using much larger samples.

NASA Center JSC↗

Comparison Between Numerically Simulated and Experimentally Measured Flowfield Quantities Behind a Pulsejet

Pulsed combustion is receiving renewed interest as a potential route to higher performance in air breathing propulsion systems. Pulsejets offer a simple experimental device with which to study unsteady combustion phenomena and validate simulations. Previous computational fluid dynamic (CFD) simulation work focused primarily on the pulsejet combustion and exhaust processes. This paper describes a new inlet sub-model which simulates the fluidic and mechanical operation of a valved pulsejet head. The governing equations for this sub-model are described. Sub-model validation is provided through comparisons of simulated and experimentally measured reed valve motion, and time averaged inlet mass flow rate. The updated pulsejet simulation, with the inlet sub-model implemented, is validated through comparison with experimentally measured combustion chamber pressure, inlet mass flow rate, operational frequency, and thrust. Additionally, the simulated pulsejet exhaust flowfield, which is dominated by a starting vortex ring, is compared with particle imaging velocimetry (PIV) measurements on the bases of velocity, vorticity, and vortex location. The results show good agreement between simulated and experimental data. The inlet sub-model is shown to be critical for the successful modeling of pulsejet operation. This sub-model correctly predicts both the inlet mass flow rate and its phase relationship with the combustion chamber pressure. As a result, the predicted pulsejet thrust agrees very well with experimental data.

Geng, Tao↗

Radio-Frequency Tank Eigenmode Sensor for Propellant Quantity Gauging

Although there are several methods for determining liquid level in a tank, there are no proven methods to quickly gauge the amount of propellant in a tank while it is in low gravity or under low-settling thrust conditions where propellant sloshing is an issue. Having the ability to quickly and accurately gauge propellant tanks in low-gravity is an enabling technology that would allow a spacecraft crew or mission control to always know the amount of propellant onboard, thus increasing the chances for a successful mission. The Radio Frequency Mass Gauge (RFMG) technique measures the electromagnetic eigenmodes, or natural resonant frequencies, of a tank containing a dielectric fluid. The essential hardware components consist of an RF network analyzer that measures the reflected power from an antenna probe mounted internal to the tank. At a resonant frequency, there is a drop in the reflected power, and these inverted peaks in the reflected power spectrum are identified as the tank eigenmode frequencies using a peak-detection software algorithm. This information is passed to a pattern-matching algorithm, which compares the measured eigenmode frequencies with a database of simulated eigenmode frequencies at various fill levels. A best match between the simulated and measured frequency values occurs at some fill level, which is then reported as the gauged fill level. The database of simulated eigenmode frequencies is created by using RF simulation software to calculate the tank eigenmodes at various fill levels. The input to the simulations consists of a fairly high-fidelity tank model with proper dimensions and including internal tank hardware, the dielectric properties of the fluid, and a defined liquid/vapor interface. Because of small discrepancies between the model and actual hardware, the measured empty tank spectra and simulations are used to create a set of correction factors for each mode (typically in the range of 0.999 1.001), which effectively accounts for the small discrepancies. These correction factors are multiplied to the modes at all fill levels. By comparing several measured modes with the simulations, it is possible to accurately gauge the amount of propellant in the tank. An advantage of the RFMG approach of applying computer simulations and a pattern-matching algorithm is that the Although there are several methods for determining liquid level in a tank, there are no proven methods to quickly gauge the amount of propellant in a tank while it is in low gravity or under low-settling thrust conditions where propellant sloshing is an issue. Having the ability to quickly and accurately gauge propellant tanks in low-gravity is an enabling technology that would allow a spacecraft crew or mission control to always know the amount of propellant onboard, thus increasing the chances for a successful mission. The Radio Frequency Mass Gauge (RFMG) technique measures the electromagnetic eigenmodes, or natural resonant frequencies, of a tank containing a dielectric fluid. The essential hardware components consist of an RF network analyzer that measures the reflected power from an antenna probe mounted internal to the tank. At a resonant frequency, there is a drop in the reflected power, and these inverted peaks in the reflected power spectrum are identified as the tank eigenmode frequencies using a peak-detection software algorithm. This information is passed to a pattern-matching algorithm, which compares the measured eigenmode frequencies with a database of simulated eigenmode frequencies at various fill levels. A best match between the simulated and measured frequency values occurs at some fill level, which is then reported as the gauged fill level. The database of simulated eigenmode frequencies is created by using RF simulation software to calculate the tank eigenmodes at various fill levels. The input to the simulations consists of a fairly high-fidelity tank model with proper dimensions and including internal tank harare, the dielectric properties of the fluid, and a defined liquid/vapor interface. Because of small discrepancies between the model and actual hardware, the measured empty tank spectra and simulations are used to create a set of correction factors for each mode (typically in the range of 0.999 1.001), which effectively accounts for the small discrepancies. These correction factors are multiplied to the modes at all fill levels. By comparing several measured modes with the simulations, it is possible to accurately gauge the amount of propellant in the tank. An advantage of the RFMG approach of applying computer simulations and a pattern-matching algorithm is that the

Zimmerli, Gregory A.↗

Aerogel-Positronium Technology for the Detection of Small Quantities of Organic and/or Toxic Materials

The Ps-aerogel system [Ps is positronium (an electron-positron-hydrogen-like atom)] has been evaluated and optimized as a potential tool for planetary exploration missions. Different configurations of use were assessed, and the results provide a quantitative measure of the expected performance. The aerogel density is first optimized to attain maximum production of Ps that reaches the pores of the aerogel. This has been accomplished, and the optimum aerogel density is .70 mg/cm3. The aerogel is used as a concentrator for target volatile moieties, which accumulate in its open porosity over an extended period of time. For the detection of the accumulated materials, the use of Ps as a probe for the environment at the pore surface, has been proposed. This concept is based on two steps: (1) using aerogel to produce Ps and (2) using the propensity of Ps to interact differently with organic and inorganic matter. The active area of such a detector will comprise aerogel with a certain density, specific surface area, and gas permeability optimized for Ps production and gas diffusion and adsorption. The aerogel is a natural adsorber of organic molecules, which adhere to its internal surface, where their presence is detected by the Ps probe. Initial estimates indicate that, e.g., trace organic molecules in the Martian atmosphere, can be detected at the ppm level, which rivals current methods having significantly higher complexity, volume, mass, and power consumption (e.g. Raman, IR).

Petkov, Mihail P.↗

Quantity Distance for the Kennedy Space Center Vehicle Assembly Building for Solid Propellant Fueled Launchers

The NASA KSC VAB was built to process Apollo launchers in the 1960's, and later adapted to process Space Shuttles. The VAB has served as a place to assemble solid rocket motors (5RM) and mate them to the vehicle's external fuel tank and Orbiter before rollout to the launch pad. As Space Shuttle is phased out, and new launchers are developed, the VAB may again be adapted to process these new launchers. Current launch vehicle designs call for continued and perhaps increased use of SRM segments; hence, the safe separation distances are in the process of being re-calculated. Cognizant NASA personnel and the solid rocket contractor have revisited the above VAB QD considerations and suggest that it may be revised to allow a greater number of motor segments within the VAB. This revision assumes that an inadvertent ignition of one SRM stack in its High Bay need not cause immediate and complete involvement of boosters that are part of a vehicle in adjacent High Bay. To support this assumption, NASA and contractor personnel proposed a strawman test approach for obtaining subscale data that may be used to develop phenomenological insight and to develop confidence in an analysis model for later use on full-scale situations. A team of subject matter experts in safety and siting of propellants and explosives were assembled to review the subscale test approach and provide options to NASA. Upon deliberations regarding the various options, the team arrived at some preliminary recommendations for NASA.

Stover, Steven↗

Validation of Quasi-Invariant Ice Cloud Radiative Quantities with MODIS Satellite-Based Cloud Property Retrievals

Similarity relations applied to ice cloud radiance calculations are theoretically analyzed and numerically validated. If t(1v) and t(1vg) are conserved where t is optical thickness, v the single-scattering albedo, and g the asymmetry factor, it is possible that substantially different phase functions may give rise to similar radiances in both conservative and non-conservative scattering cases, particularly in the case of large optical thicknesses. In addition to theoretical analysis, this study uses operational ice cloud optical thickness retrievals from the Moderate Resolution Imaging Spectroradiometer (MODIS) Level 2 Collection5 (C5) and Collection 6 (C6) cloud property products to verify radiative similarity relations. It is found that, if the MODIS C5 and C6 ice cloud optical thickness values are multiplied by their respective (1wg)factors, the resultant products referred to as the effective optical thicknesses become similar with their ratio values around unity. Furthermore, the ratios of the C5 and C6 ice cloud effective optical thicknesses display an angular variation pattern similar to that of the corresponding ice cloud phase function ratios. The MODIS C5 and C6 values of ice cloud similarity parameter, defined as [(1w)(1(exp. 1/2)wg)]12, also tend to be similar.

Radiative transfer↗

Tidal Disruptions of Main Sequence Stars - I. Observable Quantities and their Dependence on Stellar and Black Hole Mass

This paper introduces a series of papers presenting a quantitative theory for the tidal disruption of main-sequence stars by supermassive black holes. Using fully general relativistic hydrodynamics simulations and MESA-model initial conditions, we explore the pericenter-dependence of tidal disruption properties for eight stellar masses(MM0.1510)and six black hole masses( MM105 105BH7). We present here the results most relevant to observations. The effects of internal stellar structure and relativity decouple for both the disruption cross section and the characteristic energy width of the debris. Moreover, the full disruption cross section is almost independent of Må for Må/Me3. Independent of Må, relativistic effects increase the critical pericenter distance for full disruption events by up to a factor of∼3 relative to the Newtonian prediction. The probability of a direct capture is also independent of Må; at MBH/Me;5×106 this probability is equal to the probability of a complete disruption. The breadth of the debris energy distribution ΔE can differ from the standard estimate by factors of0.35−2, depending on Må and MBH, implying a corresponding change(∝(ΔE)−3/2)in the characteristic mass-return timescale. We provide analytic forms, suitable for use in both event rate estimates and parameter inference, to describe all these trends. For partial disruptions, we find a nearly universal relation between the star’s angular momentum and the fraction of Må remaining. Within the “empty loss-cone” regime, partial disruptions must precede full disruptions. These partial disruptions can drastically affect the rate and appearance of subsequent total disruptions.