Search NASA⌕ Search

SEARCH · Search NASA

Results for “quantum modulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Eutectic Processing of Semiconductor Colloidal Nanocrystals for Energy Applications

Colloidal semiconductor nanocrystals (NCs) offer a costeffective platform for light-energy conversion in X-ray scintillators, photovoltaics, lasers, and display technologies. Yet, device-relevant NCs often require complex heterostructured compositions, where lattice imperfections compromise the efficiency and stability of photoconversion processes. Here, we show that a simple synthetic detour through a eutectic state of II−VI semiconductor NCs (e.g., CdSe, ZnSe) with halide salts (e.g., CdCl 2 , ZnCl 2 ) overcomes this limitation by melting and reconstructing NC lattices into defect-free alloyed and core/shell architectures. Applied to ternary CdSeTe NCs, this process produces downconverters with record brightness and minimal line widths, delivering a 3-fold increase in film-side external quantum efficiency of commercial CdTe photovoltaic modules (First Solar Inc.). Meanwhile, eutectic processing of CdSe-based core/shell emitters yields an 8-fold enhancement in their photoluminescence stability under backlight operation, addressing the reliability bottleneck for display technologies. Together, these findings establish eutectic NC processing as a scalable route to efficient, durable photoconversion materials for energy applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

All-Electric Laser Beam Control Based on a Quantum-Confined Heterostructure with an Integrated Distributed Bragg Grating

The characteristics of semiconductor chip modulators providing the angular deflection of a laser beam due to all-electric modulation of the optical characteristics of a semiconductor heterostructure are theoretically studied. Designs for quantum-confined semiconductor waveguide heterostructures with a distributed Bragg reflector integrated on the heterostructure surface are developed. The design of a waveguide structure including 20 periods of coupled asymmetric quantum wells, which provide an optical confinement factor of the waveguide mode of 20%, and an optimized doping profile allowing a uniform electric-field distribution to be maintained in the quantum-well region in the entire range of operating voltages are proposed. In this waveguide structure, the change in the refractive index due to the quantum-confined Stark effect reaches 0.086 when the control signal changes from 0 to 6 V. It is shown that the spatial (angular) scanning of the laser beam emitted from the surface of a distributed Bragg mirror with a divergence of less than 0.1° in the range of 1°–2° is feasible for the proposed waveguide structure design.

36 MATERIALS SCIENCE↗

Upper critical magnetic field and multiband superconductivity in artificial high-𝑇 𝑐 superlattices of nano quantum wells

Artificial high-T c superlattices (AHTS) composed of quantum building blocks with tunable superconducting critical temperature have been synthesized by engineering their nanoscale geometry using the Bianconi-Perali Valletta (BPV) two-gap superconductivity theory. These quantum heterostructures consist of quantum wells made of superconducting, modulation-doped Mott insulators (S), confined by a metallic (N) potential barrier. The lattice geometry has been carefully engineered to induce the predicted Fano-Feshbach shape resonance between the gaps, near a topological Lifshitz transition. Here, we validate the BPV theory by providing compelling experimental evidence that AHTS samples, at the peak of the superconducting dome, exhibit resonant two-band, two-gap superconductivity. This is demonstrated by measuring the temperature dependence of the upper critical magnetic field, μ 0 H c2 , in samples with superlattice periods 3.3 < d < 5.28 nm and L/d ratios close to the magic value 2/3 (where L is the thickness of the superconducting La 2 CuO 4 layer and d is the superlattice period). Here, the data reveal the predicted upward concavity in H c2 (T) and a characteristic kink in the coherence length as a function of temperature, confirming the predicted two-band superconductivity with Fermi velocity ratio ≈ 0.25 and significant pair-exchange term among the two condensates.

Heterostructures↗

Investigation of the Impact of Illumination on the Polarization-Type Potential-Induced Degradation of Crystalline Silicon Photovoltaic Modules

Accelerated potential-induced degradation (PID) testing of photovoltaic modules is conventionally conducted in the dark and at high temperature and humidity levels without considering the influence of illumination. This study investigates the impact of illumination on the polarization-type PID (PID-p) on two different types of encapsulated (glass/backsheet) crystalline silicon solar cells: 1) n-type bifacial passivated emitter rear totally diffused (the front side is facing glass and PID-stressed); and 2) p-type bifacial passivated emitter and rear cell (the rear side is facing glass and PID-stressed). The samples are stressed under the conditions of -1000 V, 40 degrees C, and 40% relative humidity and at different irradiance levels (xenon lamps). While the type-A modules show no reduction in PID-p sensitivity under illumination up to 800 W/m 2 , PID-p in the type-B modules is arrested by the light at an irradiance level as low as 10 W/m 2 . Furthermore, PID-degraded type-B modules (degradation induced in the dark) exhibit a rapid recovery (full recovery in 20 min) upon exposure to light (40 W/m 2 ). External quantum efficiency measurements on the type-B modules show that ultraviolet from 300 to 400 nm is mainly responsible for the fast recovery.

14 SOLAR ENERGY↗

Quantum benchmarks for the storage or transmission of quantum light from minimal resources

We investigate several recently published benchmark criteria for storage or transmission of continuous-variable quantum information. A comparison reveals that criteria based on a Gaussian distribution of coherent states are most resilient to noise. We then address the issue of experimental resources and derive an equally strong benchmark, solely based on three coherent states and homodyne detection. This benchmark is further simplified in the presence of naturally occurring random phases, which remove the need for active input-state modulation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A comparison of digital radiography systems in terms of effective detective quantum efficiency

Purpose: The purpose of this study is to compare digital radiography systems using the metric effective detective quantum efficiency (eDQE), which better reflects digital radiography imaging system performance under clinical operating conditions, in comparison with conventional metrics such as modulation transfer function (MTF), normalized noise power spectra (NNPS), and detective quantum efficiency (DQE). Methods: The eDQE was computed by the calculation of the MTF, the NNPS, the phantom attenuation and scatter, and estimation of x-ray flux. The physical characterization of the systems was obtained with the standard beam conditions RQA5 and RQA9, using the PA Chest phantom proposed by AAPM Report no. 31 simulating the attenuation and scatter characteristics of the adult human thorax. The MTF (eMTF) was measured by using an edge test placed at the frontal surface of the phantom, the NNPS (eNNPS) was calculated from images of the phantom acquired at three different exposure levels covering the operating range of the system (E{sub 0}, which is the exposure at which a system is normally operated, 1/3 E{sub 0}, and 3 E0), and scatter measurements were assessed by using a beam-stop technique. The integral of DQE (IDQE) and eDQE (IeDQE) was calculated over the whole spatial frequency range. Results: The eMTF results demonstrate degradation due to magnification and the presence of scattered radiation. The eNNPS was influenced by the grid presence, and in some systems, it contained structured noise. At typical clinical exposure levels, the magnitude of eDQE(0) with respect to DQE(0) at RQA9 beam conditions was 13%, 17%, 16%, 36%, and 24%, respectively, for Carestream DRX-1, Carestream DRX-1C, Carestream Direct View CR975, Philips Digital Diagnost VM, and GE Revolution XR/d. These results were confirmed by the ratio of IeDQE and IDQE in the same conditions. Conclusions: The authors confirm the robustness and reproducibility of the eDQE method. As expected, the DR systems performed better than the CR systems due to their superior signal-to-noise transfer characteristics. The results of this study suggest the eDQE method may provide an opportunity to more accurately assess the clinical performance of digital radiographic imaging systems by accounting for factors such as the presence of scatter, use of an antiscatter grid, and magnification and focal spot blurring effects, which are not reflected in conventional DQE measures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electrostatic modulation of periodic potentials in a two-dimensional electron gas: From antidot lattice to quantum dot lattice

We use a dual gated device structure to introduce a gate-tuneable periodic potential in a GaAs/AlGaAs two dimensional electron gas (2DEG). Using only a suitable choice of gate voltages we can controllably alter the potential landscape of the bare 2DEG, inducing either a periodic array of antidots or quantum dots. Antidots are artificial scattering centers, and therefore allow for a study of electron dynamics. In particular, we show that the thermovoltage of an antidot lattice is particularly sensitive to the relative positions of the Fermi level and the antidot potential. A quantum dot lattice, on the other hand, provides the opportunity to study correlated electron physics. We find that its current-voltage characteristics display a voltage threshold, as well as a power law scaling, indicative of collective Coulomb blockade in a disordered background.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Perspectives of active Si photonics devices for data communication and optical sensing

Si photonics has made rapid progress in research and commercialization in the past two decades. While it started with electronic–photonic integration on Si to overcome the interconnect bottleneck in data communications, Si photonics has now greatly expanded into optical sensing, light detection and ranging (LiDAR), optical computing, and microwave/RF photonics applications. From an applied physics point of view, this perspective discusses novel materials and integration schemes of active Si photonics devices for a broad range of applications in data communications, spectrally extended complementary metal–oxide–semiconductor (CMOS) image sensing, as well as 3D imaging for LiDAR systems. We also present a brief outlook of future synergy between Si photonic integrated circuits and Si CMOS image sensors toward ultrahigh capacity optical I/O, ultrafast imaging systems, and ultrahigh sensitivity lab-on-chip molecular biosensing.

electronic band structure↗

Deep Learning Approach for High-accuracy Electron Counting of Monolithic Active Pixel Sensor-type Direct Electron Detectors at Increased Electron Dose

Abstract Electron counting can be performed algorithmically for monolithic active pixel sensor direct electron detectors to eliminate readout noise and Landau noise arising from the variability in the amount of deposited energy for each electron. Errors in existing counting algorithms include mistakenly counting a multielectron strike as a single electron event, and inaccurately locating the incident position of the electron due to lateral spread of deposited energy and dark noise. Here, we report a supervised deep learning (DL) approach based on Faster region-based convolutional neural network (R-CNN) to recognize single electron events at varying electron doses and voltages. The DL approach shows high accuracy according to the near-ideal modulation transfer function (MTF) and detector quantum efficiency for sparse images. It predicts, on average, 0.47 pixel deviation from the incident positions for 200 kV electrons versus 0.59 pixel using the conventional counting method. The DL approach also shows better robustness against coincidence loss as the electron dose increases, maintaining the MTF at half Nyquist frequency above 0.83 as the electron density increases to 0.06 e−/pixel. Thus, the DL model extends the advantages of counting analysis to higher dose rates than conventional methods.

Materials Science↗

Phase diagram of two-dimensional fast-rotating ultracold fermionic atoms near unitarity

By analyzing vortex lattices, re-entrant Cooper pairing, and Fulde-Ferrell-Larkin-Ovchinnikov (FFLO) states in a single theoretical framework, we explore how vortices and spin textures join to protect superconductivity against large magnetic fields. We use a rapidly rotating ultracold gas of fermionic atoms near unitarity as a model system amenable to experimental exploration and discover a hierarchy of spin-polarized and FFLO phases in which a metal or a band insulator of unpaired particles coexists with a spatially modulated superfluid hosting a vortex lattice. Quantum fluctuations can transform these phases into strongly correlated 'vortex-liquid' metals and insulators, respectively. We argue that vortex lattices significantly enhance the stability of FFLO states and discuss prospects for observing these states in cold-atom experiments.

36 MATERIALS SCIENCE↗

Gravity dual of spatially modulated phase

We show that the five-dimensional Maxwell theory with the Chern-Simons term is tachyonic in the presence of a constant electric field. When coupled to gravity, a sufficiently large Chern-Simons coupling causes instability of the Reissner-Nordstroem black holes in anti-de Sitter space. The instability happens only at nonvanishing momenta, suggesting a spatially modulated phase in the holographically dual quantum field theory in (3+1) dimensions, with spontaneous current generation in a helical configuration. The three-charge extremal black hole in the type IIB superstring theory on AdS{sub 5}xS{sup 5} barely satisfies the stability condition.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development and Characterization of a High-Energy Neutron Time-of-Flight Imaging System

We present that Los Alamos National Laboratory has developed a prototype of a high-energy neutron time-of-flight imaging system for the non-destructive evaluation of dense, massive, and/or high atomic number objects. High-energy neutrons provide the penetrating power, and thus the high dynamic range necessary to image internal features and defects of such objects. The addition of the time gating capability allows for scatter rejection when paired with a pulsed monoenergetic beam, or neutron energy selection when paired with a pulsed broad-spectrum neutron source. The Time Gating to Reject Scatter and Select Energy (TiGReSSE) system was tested at the Los Alamos Neutron Science Center’s (LANSCE) Weapons Nuclear Research (WNR) facility, a spallation neutron source, to provide proof of concept measurements and to characterize the instrument response. This paper will show results of several objects imaged during this run cycle. In addition, results from system performance metrics such as the Modulation Transfer Function and the Detective Quantum Efficiency measured as a function of neutron energy, characterize the current system performance and inform the next generation of neutron imaging instrument.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A dedicated cone-beam CT system for musculoskeletal extremities imaging: Design, optimization, and initial performance characterization

Purpose: This paper reports on the design and initial imaging performance of a dedicated cone-beam CT (CBCT) system for musculoskeletal (MSK) extremities. The system complements conventional CT and MR and offers a variety of potential clinical and logistical advantages that are likely to be of benefit to diagnosis, treatment planning, and assessment of therapy response in MSK radiology, orthopaedic surgery, and rheumatology. Methods: The scanner design incorporated a host of clinical requirements (e.g., ability to scan the weight-bearing knee in a natural stance) and was guided by theoretical and experimental analysis of image quality and dose. Such criteria identified the following basic scanner components and system configuration: a flat-panel detector (FPD, Varian 3030+, 0.194 mm pixels); and a low-power, fixed anode x-ray source with 0.5 mm focal spot (SourceRay XRS-125-7K-P, 0.875 kW) mounted on a retractable C-arm allowing for two scanning orientations with the capability for side entry, viz. a standing configuration for imaging of weight-bearing lower extremities and a sitting configuration for imaging of tensioned upper extremity and unloaded lower extremity. Theoretical modeling employed cascaded systems analysis of modulation transfer function (MTF) and detective quantum efficiency (DQE) computed as a function of system geometry, kVp and filtration, dose, source power, etc. Physical experimentation utilized an imaging bench simulating the scanner geometry for verification of theoretical results and investigation of other factors, such as antiscatter grid selection and 3D image quality in phantom and cadaver, including qualitative comparison to conventional CT. Results: Theoretical modeling and benchtop experimentation confirmed the basic suitability of the FPD and x-ray source mentioned above. Clinical requirements combined with analysis of MTF and DQE yielded the following system geometry: a {approx}55 cm source-to-detector distance; 1.3 magnification; a 20 cm diameter bore (20 x 20 x 20 cm{sup 3} field of view); total acquisition arc of {approx}240 deg. The system MTF declines to 50% at {approx}1.3 mm{sup -1} and to 10% at {approx}2.7 mm{sup -1}, consistent with sub-millimeter spatial resolution. Analysis of DQE suggested a nominal technique of 90 kVp (+0.3 mm Cu added filtration) to provide high imaging performance from {approx}500 projections at less than {approx}0.5 kW power, implying {approx}6.4 mGy (0.064 mSv) for low-dose protocols and {approx}15 mGy (0.15 mSv) for high-quality protocols. The experimental studies show improved image uniformity and contrast-to-noise ratio (without increase in dose) through incorporation of a custom 10:1 GR antiscatter grid. Cadaver images demonstrate exquisite bone detail, visualization of articular morphology, and soft-tissue visibility comparable to diagnostic CT (10-20 HU contrast resolution). Conclusions: The results indicate that the proposed system will deliver volumetric images of the extremities with soft-tissue contrast resolution comparable to diagnostic CT and improved spatial resolution at potentially reduced dose. Cascaded systems analysis provided a useful basis for system design and optimization without costly repeated experimentation. A combined process of design specification, image quality analysis, clinical feedback, and revision yielded a prototype that is now awaiting clinical pilot studies. Potential advantages of the proposed system include reduced space and cost, imaging of load-bearing extremities, and combined volumetric imaging with real-time fluoroscopy and digital radiography.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A forward bias method for lag correction of an a-Si flat panel detector

Purpose: Digital a-Si flat panel (FP) x-ray detectors can exhibit detector lag, or residual signal, of several percent that can cause ghosting in projection images or severe shading artifacts, known as the radar artifact, in cone-beam computed tomography (CBCT) reconstructions. A major contributor to detector lag is believed to be defect states, or traps, in the a-Si layer of the FP. Software methods to characterize and correct for the detector lag exist, but they may make assumptions such as system linearity and time invariance, which may not be true. The purpose of this work is to investigate a new hardware based method to reduce lag in an a-Si FP and to evaluate its effectiveness at removing shading artifacts in CBCT reconstructions. The feasibility of a novel, partially hardware based solution is also examined. Methods: The proposed hardware solution for lag reduction requires only a minor change to the FP. For pulsed irradiation, the proposed method inserts a new operation step between the readout and data collection stages. During this new stage the photodiode is operated in a forward bias mode, which fills the defect states with charge. A Varian 4030CB panel was modified to allow for operation in the forward bias mode. The contrast of residual lag ghosts was measured for lag frames 2 and 100 after irradiation ceased for standard and forward bias modes. Detector step response, lag, SNR, modulation transfer function (MTF), and detective quantum efficiency (DQE) measurements were made with standard and forward bias firmware. CBCT data of pelvic and head phantoms were also collected. Results: Overall, the 2nd and 100th detector lag frame residual signals were reduced 70%-88% using the new method. SNR, MTF, and DQE measurements show a small decrease in collected signal and a small increase in noise. The forward bias hardware successfully reduced the radar artifact in the CBCT reconstruction of the pelvic and head phantoms by 48%-81%. Conclusions: Overall, the forward bias method has been found to greatly reduce detector lag ghosts in projection data and the radar artifact in CBCT reconstructions. The method is limited to improvements of the a-Si photodiode response only. A future hybrid mode may overcome any limitations of this method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cone beam breast CT with a high pitch (75 μm), thick (500 μm) scintillator CMOS flat panel detector: Visibility of simulated microcalcifications

Purpose: To measure and investigate the improvement of microcalcification (MC) visibility in cone beam breast CT with a high pitch (75 μm), thick (500 μm) scintillator CMOS/CsI flat panel detector (Dexela 2923, Perkin Elmer).Methods: Aluminum wires and calcium carbonate grains of various sizes were embedded in a paraffin cylinder to simulate imaging of calcifications in a breast. Phantoms were imaged with a benchtop experimental cone beam CT system at various exposure levels. In addition to the Dexela detector, a high pitch (50 μm), thin (150 μm) scintillator CMOS/CsI flat panel detector (C7921CA-09, Hamamatsu Corporation, Hamamatsu City, Japan) and a widely used low pitch (194 μm), thick (600 μm) scintillator aSi/CsI flat panel detector (PaxScan 4030CB, Varian Medical Systems) were also used in scanning for comparison. The images were independently reviewed by six readers (imaging physicists). The MC visibility was quantified as the fraction of visible MCs and measured as a function of the estimated mean glandular dose (MGD) level for various MC sizes and detectors. The modulation transfer functions (MTFs) and detective quantum efficiencies (DQEs) were also measured and compared for the three detectors used.Results: The authors have demonstrated that the use of a high pitch (75 μm) CMOS detector coupled with a thick (500 μm) CsI scintillator helped make the smaller 150–160, 160–180, and 180–200 μm MC groups more visible at MGDs up to 10.8, 9, and 10.8 mGy, respectively. It also made the larger 200–212 and 212–224 μm MC groups more visible at MGDs up to 7.2 mGy. No performance improvement was observed for 224–250 μm or larger size groups. With the higher spatial resolution of the Dexela detector based system, the apparent dimensions and shapes of MCs were more accurately rendered. The results show that with the aforementioned detector, a 73% visibility could be achieved in imaging 160–180 μm MCs as compared to 28% visibility achieved by the low pitch (194 μm) aSi/CsI flat panel detector. The measurements confirm that the Hamamatsu detector has the highest MTF, followed by the Dexel detector, and then the Varian detector. However, the Dexela detector, with its thick (500 μm) CsI scintillator and low noise level, has the highest DQE at all frequencies, followed by the Varian detector, and then the Hamamatsu detector. The findings on the MC visibility correlated well with the differences in MTFs, noise power spectra, and DQEs measured for these three detectors.Conclusions: The authors have demonstrated that the use of the CMOS type Dexela detector with its high pitch (75 μm) and thick (500 μm) CsI scintillator could help improve the MC visibility. However, the improvement depended on the exposure level and the MC size. For imaging larger MCs or scanning at high exposure levels, there was little advantage in using the Dexela detector as compared to the aSi type Varian detector. These findings correlate well with the higher measured DQEs of the Dexela detector, especially at higher frequencies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fluorescence lifetime measurements using photon pair correlations generated via spontaneous parametric down conversion (SPDC)

We have used photon pair correlations generated via spontaneous parametric downconversion (SPDC) to measure the fluorescence lifetime of the organic dye rhodamine 6 G, demonstrating that fluorescence lifetime measurements can be achieved using a continuous wave (CW) laser, without pulsed or modulated lasers. Our entangled photon method, quantum fluorescence lifetime (Q-FL) measurements, uses one photon to excite fluorescence and the resulting fluorescence photon is timed and referenced to the arrival time of the other entangled photon. Thus, we can exploit the short timescale of photon pair correlations to conduct experiments that are typically carried out with pulsed lasers and we show that the inherent timing of the photons is fast enough to resolve the nanosecond scale fluorescence lifetime of the sample. This measurement paves the way towards using the time correlations of entangled photons for fluorescence imaging; capitalizing on the presence of fast, sub-100 ps correlations that have not been demonstrated classically.

Eshun, Audrey (ORCID:0000000167697082)↗

Precision control of multiple quantum cascade lasers for calibration systems

We present a precision, 1-A, digitally interfaced current controller for quantum cascade lasers, with demonstrated temperature coefficients for continuous and 40-kHz full-depth square-wave modulated operation, of 1–2 ppm/ °C and 15 ppm/ °C, respectively. High precision digital to analog converters (DACs) together with an ultra-precision voltage reference produce highly stable, precision voltages, which are selected by a multiplexer (MUX) chip to set output currents via a linear current regulator. The controller is operated in conjunction with a power multiplexing unit, allowing one of three lasers to be driven by the controller, while ensuring protection of controller and all lasers during operation, standby, and switching. Simple ASCII commands sent over a USB connection to a microprocessor located in the current controller operate both the controller (via the DACs and MUX chip) and the power multiplexer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantum Monte Carlo study of lattice polarons in the two-dimensional three-orbital Su–Schrieffer–Heeger model

The electron–lattice interaction gives rise to a rich set of phenomena in quantum materials. Microscopically, this interaction often arises from the modulation of orbital overlaps; however, many theoretical studies neglect such couplings. Here, we present an exact diagonalization and determinant quantum Monte Carlo study of a three-orbital Su–Schrieffer–Heeger (SSH) model, on a two-dimensional Lieb lattice and in the negative charge transfer regime. At half-filling (one hole/unit cell), we observe a bipolaron insulating phase with a bond-disproportionate lattice. This phase is robust against moderate hole doping but is suppressed at large hole concentrations, leading to a metallic polaron-liquid-like state with fluctuating patches of local distortions. We also find an s-wave superconducting state at large hole doping that primarily appears on the oxygen sublattice. Our work provides a non-perturbative view of SSH-type couplings in two dimensions with implications for materials where such couplings are dominant.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗