Search NASA⌕ Search

SEARCH · Search NASA

Results for “radiance calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Response Versus Scan-Angle Corrections for MODIS Reflective Solar Bands Using Deep Convective Clouds

The absolute radiometric calibration of the reflective solar bands (RSBs) of Aqua- and Terra-MODIS is performed using on-board calibrators. A solar diffuser (SD) panel along with a solar diffuser stability monitor (SDSM) system, which tracks the performance of the SD over time, provides the absolute reference for calibrating the MODIS sensors. MODIS also views the moon and deep space through its space view (SV) port for lunar-based calibration and computing the zero input radiance, respectively. The MODIS instrument views the Earth's surface through a two-sided scan mirror, whose reflectance is a function of angle of incidence (AOI) and is described by response versus scan-angle (RVS). The RVS for both MODIS instruments was characterized prior to launch. MODIS also views the SD and the moon at two different assigned RVS positions. There is sufficient evidence that the RVS is changing on orbit over time and as a function of wavelength. The SD and lunar observation scans can only track the RVS variation at two RVS positions. Consequently, the MODIS Characterization Support Team (MCST) developed enhanced approaches that supplement the onboard calibrator measurements with responses from pseudo-invariant desert sites. This approach has been implemented in Level 1B (L1B) Collection 6 (C6) for selected short-wavelength bands. This paper presents an alternative approach of characterizing the mirror RVS to derive the time-dependent RVS correction factors for MODIS RSBs using tropical deep convective cloud (DCC) targets. An initial assessment of the DCC response from Aqua-MODIS band 1 C6 data indicates evidence of RVS artifacts, which are not uniform across the scans and are more prevalent in the left side Earth-view scans.

Bhatt, Rajendra↗

Multiple-angle observations of reflectance anisotropy from an airborne linear array sensor

An airborne pointable imaging multispectral linear array sensor has been developed for the multidirectional observation of surface reflectance anisotropy. The sensor design permits observations up to 45 deg off-nadir in three spectral bands (green, red, and near-infrared). Calibration permits the conversion of sensor data to radiance units with an absolute uncertainty of 6 percent. Observations of five field plots from seven view directions are discussed. Calibration and atmospheric corrections are used to derive hemispherical-directional reflectance factors. A three-term reflectance model is fit to the reflectance factors for each plot to represent the continuous distribution of reflectance factors with view direction. The reflectance model is integrated over all view directions to calculate bihemispherical reflectance factors. The calculated bihemispherical factors differed by 1 to 25 percent from values based on an assumption of isotropic reflectance depending on spectral band and field plot. These calculations demonstrate the technologic and scientific capabilities required for the remote characterization of surface reflectance anisotropy. Remote multidirectional observations are both feasible and needed to fully evaluate land reflectance characteristics.

Irons, James R.↗

JPSS-2 VIIRS Pre-Launch Reflective Solar Band Testing and Performance

The Visible Infrared Imaging Radiometer Suite (VIIRS) instruments on-board the Suomi National Polar-orbiting Partnership (S-NPP) and Joint Polar Satellite System (JPSS) spacecrafts 1 and 2 provides calibrated sensor data record (SDR) reflectance, radiance, and brightness temperatures for use in environment data record (EDR) products. The SDRs and EDRs are used in weather forecasting models, weather imagery and climate applications such as ocean color, sea surface temperature and active fires. The VIIRS has 22 bands covering a spectral range 0.4–12.4 m with resolutions of 375 m and 750 m for imaging and moderate bands respectively on four focal planes. The bands are stratified into three different types based on the source of energy sensed by the bands. The reflective solar bands (RSBs) detect sunlight reflected from the Earth, thermal emissive bands (TEBs) sense emitted energy from the Earth and the day/night band (DNB) detects both solar and lunar reflected energy from the Earth. The SDR calibration uses a combination of pre-launch testing and the solar diffuser (SD), on-board calibrator blackbody (OBCBB) and space view (SV) on-orbit calibrator sources. The pre-launch testing transfers the National Institute of Standards and Technology (NIST) traceable calibration to the SD, for the RSB, and the OBCBB, for the TEB. Post-launch, the on-board calibrators track the changes in instrument response and adjust the SDR product as necessary to maintain the calibration. This paper will discuss the pre-launch radiometric calibration portion of the SDR calibration for the RSBs that includes the dynamic range, detector noise, calibration coefficients and radiometric uncertainties for JPSS-2 VIIRS.

JPSS↗

Simulation studies and the need for field reflectance studies

There is a need to calibrate satellite data obtained at large polar (i.e., off-nadir) view angles for effects caused by scanner geometry and by the atmosphere. If such effects are not corrected for, then recorded radiance data will contain systematic and random errors which will make accurate target identification and quantification difficult. Adequate calibration of digital radiance data requires both an inductive analysis of digital satellite images and a deductive analysis based upon a priori simulation studies. The inputs to a simulation model (ground reflectance, atmospheric transmission and bandscatter) and their variability are dependent upon (for example) sun-target-sensor geometry. There is a major need to make accurate ground reflectance measurements to provide calibration information on the anisotropy of ground reflectance. There is also a need to assess atmospheric transmission and backscatter from the image itself. A potential simple, inexpensive method for making ground reflectance measurements in the above context is discussed.

Duggin, M. J.↗

Comparing the shock sensitivity of insensitive energetic materials

We present a tabletop method to study the shock sensitivity of plastic-bonded explosives that are considered shock insensitive using high dynamic range optical emission spectroscopy with laser-launched km/s flyer plate impacts (2, 3, and 4 km/s), which measures the spectral radiance (the emission spectrum vs a calibrated intensity standard) every 0.8 ns in the nanosecond and microsecond regimes. The explosives were TATB (1,3,5 trinitro, 2,4,6 triamino benzene), FOX-7 (1,1-diamino-2,2-dinitroethylene), LLM-105 (2,6-diamino-3,5-dinitropyrazine-1-oxide), and NTO (nitrotriazolone), all with 20% Sylgard 182 binder. Time resolving emission from shocked explosives produces a unique fingerprint at each shock pressure, and the emission temporal profile can be used to understand each material's shock response and the underlying mechanisms within the framework of the well-known shock ignition and growth models. Ignition was characterized by the emission intensity during nanosecond hot spot ignition. The growth process, which occurs after the shock has unloaded, was characterized by the time derivative of microsecond emission intensity. Singular-value decomposition was used to determine a characteristic spectral radiance over the entire time range, and this radiance was fit to a graybody model to determine a characteristic temperature Tc. Even though these insensitive explosives have similar shock sensitivities, our method can clearly distinguish their shock response. FOX-7 and NTO were the most sensitive, with FOX-7 having the greatest shock ignition sensitivity, growth rate, and Tc. LLM-105 was much less sensitive than FOX-7 and NTO, and TATB consistently showed the lowest sensitivity by any measure.

Akhtar, Meysam (ORCID:0000000243897837)↗

Infrared Cloud Imager Instrument Intercomparison Report

The Infrared Cloud Imager Instrument Intercomparison was a guest instrument deployment by NWB Sensors to the U.S. Department of Energy’s Atmospheric Radiation Measurement (ARM) User Facility observatory on the Southern Great Plains (SGP) between May 18 and December 12, 2023. NWB Sensors is a company that has developed a commercially available infrared cloud imager (ICI). The ICI provides radiometrically calibrated, full-sky images of the downwelling infrared radiance in the 7.3-14 µm band. In addition, it provides cloud radiance as the residual between the observed radiance and the modeled cloud-free radiance as well as derived cloud products. The instrument is used in applications that require consistent detection of clouds across day and night. For more information, consult the instrument's webpage. The primary goal of the deployment was to validate the radiometric accuracy of the ICI. The ICI uses a proprietary calibration method to convert the raw data from its infrared camera into downwelling radiance. Unlike similar instruments, the system does not have an onboard blackbody calibration standard. Instead, NWB Sensors characterizes each ICI camera individually in an environmental chamber while looking at a blackbody standard. The resulting (proprietary) calibration is used operationally in the instrument and has been demonstrated to be stable over long periods. To validate the radiometric products from the ICI, an intercomparison between the ICI data products and those from ARM’s atmospheric emitted radiance interferometer (AERI) was made. The AERI is a best-in-class instrument for measuring downwelling infrared radiance (Gero et al. 2025). A weighted integration of the AERI’s spectral radiances across the ICI’s camera response was performed. The resulting radiance (herein called the AERI radiance) was directly compared to the zenith radiance concurrently observed by the ICI. The results of these comparisons are reported in the next section of this report.

54 ENVIRONMENTAL SCIENCES↗

Radiometric analysis of the longwave infrared channel of the Thematic Mapper on LANDSAT 4 and 5

The first objective was to evaluate the postlaunch radiometric calibration of the LANDSAT Thematic Mapper (TM) band 6 data. The second objective was to determine to what extent surface temperatures could be computed from the TM and 6 data using atmospheric propagation models. To accomplish this, ground truth data were compared to a single TM-4 band 6 data set. This comparison indicated satisfactory agreement over a narrow temperature range. The atmospheric propagation model (modified LOWTRAN 5A) was used to predict surface temperature values based on the radiance at the spacecraft. The aircraft data were calibrated using a multi-altitude profile calibration technique which had been extensively tested in previous studies. This aircraft calibration permitted measurement of surface temperatures based on the radiance reaching the aircraft. When these temperature values are evaluated, an error in the satellite's ability to predict surface temperatures can be estimated. This study indicated that by carefully accounting for various sensor calibration and atmospheric propagation effects, and expected error (1 standard deviation) in surface temperature would be 0.9 K. This assumes no error in surface emissivity and no sampling error due to target location. These results indicate that the satellite calibration is within nominal limits to within this study's ability to measure error.

Schott, John R.↗

Investigation of techniques for correcting ERTS data for solar and atmospheric effects

The author has identified the following significant results. The design and fabrication of five radiant power measuring instruments (RPMI) for ERTS ground truth have been completed. These instruments will be deployed in concert with ERTS overflights to obtain radiometric measurements needed to determine solar and atmospheric parameters that effect ERTS radiance measurements. With these parameters, the accuracy and capability of various procedures for transforming ERTS data into absolute target reflectance signatures will be evaluated. The RPMI is a rugged, hand-carried instrument accurately calibrated to measure both downwelling and reflected radiance within each ERTS multispectral scanner band. A foldover handle permits a quick change from wide angle global or sky irradiance measurements to narrow angle radiance measurements from sky and ground targets. These measurements yield ground truth site reflectance and permit calculation of additional parameters such as beam transmittance between spacecraft and ground, and path radiance (path reflectance).

Rogers, R. H.↗

The Calibration of AVHRR Visible Dual Gain using Meteosat-8 for NOAA-16 to 18

The NOAA AVHRR program has given the remote sensing community over 25 years of imager radiances to retrieve global cloud, vegetation, and aerosol properties. This dataset can be used for long-term climate research, if the AVHRR instrument is well calibrated. Unfortunately, the AVHRR instrument does not have onboard visible calibration and does degrade over time. Vicarious post-launch calibration is necessary to obtain cloud properties that are not biased over time. The recent AVHRR-3 instrument has a dual gain in the visible channels in order to achieve greater radiance resolution in the clear-sky. This has made vicarious calibration of the AVHRR-3 more difficult to unravel. Reference satellite radiances from well-calibrated instruments, usually equipped with solar diffusers, such as MODIS, have been used to successfully vicariously calibrate other visible instruments. Transfer of calibration from one satellite to another using co-angled, collocated, coincident radiances has been well validated. Terra or Aqua MODIS and AVHRR comparisons can only be performed over the poles during summer. However, geostationary satellites offer a transfer medium that captures both parts of the dual gain. This AVHRR-3 calibration strategy uses, calibrated with MODIS, Meteosat-8 radiances simultaneously to determine the dual gains using 50km regions. The dual gain coefficients will be compared with the nominal coefficients. Results will be shown for all visible channels for NOAA-17.

Doelling, David R.↗

EOS Terra Validation Program

The EOS Terra mission will be launched in July 1999. This mission has great relevance to the atmospheric radiation community and global change issues. Terra instruments include ASTER, CERES, MISR, MODIS and MOPITT. In addition to the fundamental radiance data sets, numerous global science data products will be generated, including various Earth radiation budget, cloud and aerosol parameters, as well as land surface, terrestrial ecology, ocean color, and atmospheric chemistry parameters. Significant investments have been made in on-board calibration to ensure the quality of the radiance observations. A key component of the Terra mission is the validation of the science data products. This is essential for a mission focused on global change issues and the underlying processes. The Terra algorithms have been subject to extensive pre-launch testing with field data whenever possible. Intensive efforts will be made to validate the Terra data products after launch. These include validation of instrument calibration (vicarious calibration) experiments, instrument and cross-platform comparisons, routine collection of high quality correlative data from ground-based networks, such as AERONET, and intensive sites, such as the SGP ARM site, as well as a variety field experiments, cruises, etc. Airborne simulator instruments have been developed for the field experiment and underflight activities including the MODIS Airborne Simulator (MAS), AirMISR, MASTER (MODIS-ASTER), and MOPITT-A. All are integrated on the NASA ER-2, though low altitude platforms are more typically used for MASTER. MATR is an additional sensor used for MOPITT algorithm development and validation. The intensive validation activities planned for the first year of the Terra mission will be described with emphasis on derived geophysical parameters of most relevance to the atmospheric radiation community. Detailed information about the EOS Terra validation Program can be found on the EOS Validation program homepage i/e.: http://ospso.gsfc.nasa.gov/validation/valpage.html).

Starr, David↗

EOS Terra Validation Program

The EOS Terra mission will be launched in July 1999. This mission has great relevance to the atmospheric radiation community and global change issues. Terra instruments include Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER), Clouds and Earth's Radiant Energy System (CERES), Multi-Angle Imaging Spectroradiometer (MISR), Moderate Resolution Imaging Spectroradiometer (MODIS) and Measurements of Pollution in the Troposphere (MOPITT). In addition to the fundamental radiance data sets, numerous global science data products will be generated, including various Earth radiation budget, cloud and aerosol parameters, as well as land surface, terrestrial ecology, ocean color, and atmospheric chemistry parameters. Significant investments have been made in on-board calibration to ensure the quality of the radiance observations. A key component of the Terra mission is the validation of the science data products. This is essential for a mission focused on global change issues and the underlying processes. The Terra algorithms have been subject to extensive pre-launch testing with field data whenever possible. Intensive efforts will be made to validate the Terra data products after launch. These include validation of instrument calibration (vicarious calibration) experiments, instrument and cross-platform comparisons, routine collection of high quality correlative data from ground-based networks, such as AERONET, and intensive sites, such as the SGP ARM site, as well as a variety field experiments, cruises, etc. Airborne simulator instruments have been developed for the field experiment and underflight activities including the MODIS Airborne Simulator (MAS) AirMISR, MASTER (MODIS-ASTER), and MOPITT-A. All are integrated on the NASA ER-2 though low altitude platforms are more typically used for MASTER. MATR is an additional sensor used for MOPITT algorithm development and validation. The intensive validation activities planned for the first year of the Terra mission will be described with emphasis on derived geophysical parameters of most relevance to the atmospheric radiation community.

Starr, David↗

Suomi NPP VIIRS DNB and RSB M Bands Detector-To-Detector and HAM Side Calibration Differences Assessment Using a Homogenous Ground Target

Near-nadir observations of the Libya 4 site from the S-NPP VIIRS Day-Night Band (DNB) and Moderate resolution Bands (M bands) are used to assess the detector calibration stability and half-angle mirror (HAM) side differences. Almost seven years of Sensor Data Records products are extracted from the Libya 4 site center over an area of 32×32 pixels. The mean values of the radiance from individual detectors per HAM side are computed separately. The comparison of the normalized radiance between detectors indicates that the detector calibration differences are wavelength dependent and the differences have been slowly increasing with time for short wavelength bands, especially for M1-M4. The maximum annual average differences between DNB detectors are 0.77% in 2017 at HAM-A. For the M bands, the maximum detector differences in 2017 are 1.7% for M1, 1.8% for M2, 1.3% for M3, 1.2% for M4, 0.67% for M5, 0.75% for M7, 0.57% for M8, 13% for M9, 0.63% for M10, and 0.66% for M11. The average HAM side A to B difference in 2017 are 0.00% for DNB, 0.22% for M1, 0.17% for M2, 0.15% for M3, 0.09% for M4, -0.07% for M5, 0.02% for M7, 0.01% for M8, 1.4% for M9, 0.01% for M10, and 0.03% for M11. Results for M6 are not available due to the signal saturation and M9 results are not accurate because of the low reflectance from the desert site and the strong atmospheric absorption in this channel. The results in this study help scientists better understand each detector’s performance and HAM side characteristics. Additionally, they provide evidence and motivation for future VIIRS calibration improvements.

SNPP VIIRS↗

SeaWiFS Postlaunch Technical Report Series: The 1997 Prelaunch Radiometric Calibration of SeaWiFS - Volume 4

The Sea-viewing Wide Field-of-view Sensor (SeaWiFS) was originally calibrated by the instrument's manufacturer, Santa Barbara Research Center (SBRC), in November 1993. In preparation for an August 1997 launch, the SeaWiFS Project and the National Institute of Standards and Technology (NIST) undertook a second calibration of SeaWiFS in January and April 1997 at the facility of the spacecraft integrator, Orbital Sciences Corporation (OSC). This calibration occurred in two phases, the first after the final thermal vacuum test, and the second after the final vibration test of the spacecraft. For the calibration, SeaWiFS observed an integrating sphere from the National Aeronautics and Space Administration (NASA) Goddard Space Flight Center (GSFC) at four radiance levels. The spectral radiance of the sphere at these radiance levels was also measured by the SeaWiFS Transfer Radiometer (SXR). In addition, during the calibration, SeaWiFS and the SXR observed the sphere at 16 radiance levels to determine the linearity of the SeaWiFS response. As part of the calibration analysis, the GSFC sphere was also characterized using a GSFC spectroradiometer. The 1997 calibration agrees with the initial 1993 calibration to within +/- 4%. The new calibration coefficients, computed before and after the vibration test, agree to within 0.5%. The response of the SeaWiFS channels in each band is linear to better than 1%. In order to compare to previous and current methods, the SeaWiFS radiometric responses are presented in two ways: using the nominal center wave-lengths for the eight bands; and using band-averaged spectral radiances. The band-averaged values are used in the flight calibration table. An uncertainty analysis for the calibration coefficients is also presented.

Hooker, Stanford B.↗

Short Time Scale Stability Monitoring of GOES-16 Visible Channels by Utilizing Daily Inter-Calibration Events with both VIIRS and MODIS Sensors

The CERES project relies on MODIS, VIIRS and geostationary (GEO) imager retrieved cloud properties to compute surface fluxes and convert CERES and GEO radiances into TOA fluxes. The CERES TOA and surface fluxes need to be of climate quality and any anomaly or discontinuity in the calibration of the MODIS, VIIRS, GEO radiances need to be mitigated or avoided. Due to the nature of the CERES instrument calibration, there is a lag time of 3 months before the processing of the CERES product. This allows the CERES team to investigate any unforeseen problems in the input datasets or GEO calibration discontinuities or anomalies before processing. The CERES geostationary imager calibration team is developing a daily monitoring system of GEO, MODIS and VIIRS visible channel radiances in order to detect any day to day discontinuities as part of the CERES/GEO coincident ray-matching calibration efforts. a GEO discontinuity can be detected using two MODIS and 2 VIIRS sensors simultaneously, thus increasing the sampling greatly over a single GEO/LEO radiance pairs. This method is being automated and has already detected three erroneous radiometric calibration events, which were verified with the GOES-16 event log page. One advantage of daily monitoring is that the time period needed to verify calibration drifts is reduced and the confidence to detect even smaller magnitudes of the calibration drift is increased over monthly monitoring. By utilizing Terra and Aqua MODIS and NPP and NOAA20 VIIRS imagers to inter-calibrate GOES-16, the GOES-16 calibration can be referenced to anyone of these imagers. If the CERES project transitions between the Aqua-MODIS imager to the NOAA20 VIIRS imager, the NOAA-20 VIIRS imager can be radiometrically scale to Aqua-MODIS calibration, thus avoiding a GOES-16 calibration discontinuity.

David Robert Doelling↗

Precision LWIR calibration and test

Precision calibration system with adjustable temperature extended radiance source for long wavelength IR radiometer, discussing performance tests

Otte, A. A.↗

Photometer calibration problem for extended astronomical sources

Analysis of calibration tests for the Skylab experimental T027 photometer is used to show that if an instrument is focused at infinity, the uniform extended calibration source should be positioned at distances at least equal to the hyperfocal distance and should be large enough to fill the field of view. It is noted that the field depth can be increased by focusing the optical system at the hyperfocal distance and that this method of focusing reduces the needed diameter of the calibration source to half that of a system focused at infinity. Other calibration methods discussed includes determining the radiance responsivity distance and extrapolating the curve to larger distances as well as extensive mapping of the spatial response combined with the irradiance responsivity to obtain the radiance responsivity.

Muscari, J. A.↗

Ocean color remote sensing systems - Radiometric requirements

A methodology for specifying the radiometric requirements for ocean color remote sensing systems is described. Consideration is given to the noise equivalent radiance, the saturation radiance, the polarization sensitivity, and the calibration and stability. The degree of polarization across a scan line for the CZCS and MODIS orbits is presented.

Gordon, Howard R.↗

Calibration of satellite sensors in the thermal infrared

The addition of a calibration capability in the 8-14 micron thermal infrared region to the current ground-based calibration of orbiting sensors is discussed. Radiance- and reflectance-based methods are compared. An infrared thermometer was selected as the favored instrument for the determination of ground truth. Three methods to determine the effect of sky background on the thermal emittance of the ground are presented, along with use of LOWTRAN 7 to determine atmospheric effects.

Palmer, James M.↗