Search NASA⌕ Search

SEARCH · Search NASA

Results for “radio science”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

TaO x electron transport layers for CO 2 reduction Si photocathodes

Electron transport layers (ETLs) used as components of photocathodes for light-driven CO 2 reduction (CO 2 R) in aqueous media should have good electronic transport, be stable under CO 2 R conditions, and, ideally, be catalytically inert for the competing hydrogen evolution reaction (HER). Here, using planar p-Si (100) as the absorbing material, we show that TaO x satisfies all three of the above criteria. TaO x films were synthesized by both pulsed laser deposition (PLD) and radio-frequency (RF) sputtering. In both cases, careful control of the oxygen partial pressure during growth was required to produce ETLs with acceptable electron conductivity. p-Si/TaO x photocathodes were interfaced with ca. 10 nm of a CO 2 R catalyst: Cu or Au. Under front illumination with simulated AM 1.5G in CO 2 -saturated bicarbonate buffer, we observed, for both metals, faradaic efficiencies for CO 2 R products of ~50% and ~30% for PLD TaO x and RF sputtered TaO x , respectively, at photocurrent densities up to 8 mA cm -2 . p-Si/TiO 2 /Cu photocathodes were also evaluated but produced mostly H 2 (>97%) due to reduction of the TiO 2 to Ti metal under CO 2 R conditions. In contrast, a dual ETL photocathode (p-Si/TiO 2 /TaO x /Cu) was selective for CO 2 R, which suggests a strategy for separately optimizing selective charge collection and the stability of the ETL/water interface. The maximum photovoltage obtained with p-Si/TaO x /Cu devices was 300 mV which was increased to 430–460 mV by employing ion implantation to make pn + -Si/TaO x /Cu structures. Photocathodes with RF sputtered TaO x ETLs are stable for CO 2 R for at least 300 min. In conclusion, techno-economic analysis shows that the reported system, if scaled, could allow for an economically viable production of feedstocks for chemical synthesis under the adoption of specific CO 2 credit schemes, thus becoming a significant component of carbon-neutral manufacturing.

36 MATERIALS SCIENCE↗

Radio measurements of the depth of air-shower maximum at the Pierre Auger Observatory

The (AERA), part of the Pierre Auger Observatory, is currently the largest array of radio antenna stations deployed for the detection of cosmic rays, spanning an area of 17 km 2 with 153 radio stations. It detects the radio emission of extensive air showers produced by cosmic rays in the 30–80 MHz band. Here, we report the AERA measurements of the ( X max ), a probe for mass composition, at cosmic-ray energies between 10 17.5 and 10 18.8 eV , which show agreement with earlier measurements with the fluorescence technique at the Pierre Auger Observatory. We show advancements in the method for radio X max reconstruction by comparison to dedicated sets of / air-shower simulations, including steps of reconstruction-bias identification and correction, which is of particular importance for irregular or sparse radio arrays. Using the largest set of radio air-shower measurements to date, we show the radio X max resolution as a function of energy, reaching a resolution better than 15 g cm − 2 at the highest energies, demonstrating that radio X max measurements are competitive with the established high-precision fluorescence technique. In addition, we developed a procedure for performing an extensive data-driven study of systematic uncertainties, including the effects of acceptance bias, reconstruction bias, and the investigation of possible residual biases. These results have been cross-checked with air showers measured independently with both the radio and fluorescence techniques, a setup unique to the Pierre Auger Observatory. Published by the American Physical Society 2024

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Demonstrating Agreement between Radio and Fluorescence Measurements of the Depth of Maximum of Extensive Air Showers at the Pierre Auger Observatory

We show, for the first time, radio measurements of the depth of shower maximum ( X max ) of air showers induced by cosmic rays that are compared to measurements of the established fluorescence method at the same location. Using measurements at the Pierre Auger Observatory we show full compatibility between our radio and the previously published fluorescence dataset, and between a subset of air showers observed simultaneously with both radio and fluorescence techniques, a measurement setup unique to the Pierre Auger Observatory. Furthermore, we show radio X max resolution as a function of energy and demonstrate the ability to make competitive high-resolution X max measurements with even a sparse radio array. With this, we show that the radio technique is capable of cosmic-ray mass composition studies, both at Auger and at other experiments. Published by the American Physical Society 2024

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ubiquitin-specific protease 14 promotes radio-resistance and suppresses autophagy in oral squamous cell carcinoma

Highlights: • USP14 promotes radioresistance of OSCC cells. • USP14 elevates radioresistance of OSCC cells by suppressing apoptosis. • USP14 modulates radioresistance in OSCC by regulating autophagy. Oral squamous cell carcinoma (OSCC) is a common malignant tumor in the world. Radiotherapy is one of the standard therapies for patients with OSCC, but its clinical efficiency is limited due to radioresistance. In this study, we identified a mechanism of such resistance regulated by Ubiquitin-specific protease 14 (USP14). USP14 expression was significantly increased in clinical OSCC tissue samples and cell lines, and OSCC patients with high USP14 expression predicted poor overall survival rate. Additionally, a negative correlation between USP14 and LC3B was observed in patients with OSCC. We then found that irradiation (IR)-reduced cell survival of OSCC cells lines was further decreased when USP14 was knocked down. However, USP14 over-expression significantly promoted the cell viability of OSCC cells after IR treatment. Colony formation analysis confirmed thatafter IR treatment,USP14 knockdown markedly decreased the proliferation of OSCC cells, but over-expressing USP14 significantly up-regulated the proliferative activity of OSCC cells. Furthermore, DNA damage caused by IR was enhanced by USP14 knockdown, while been suppressed in OSCC cells with USP14 over-expression. Additionally, IR-inducedapoptosis was further promoted by USP14 knockdown in OSCC cells, which was, however, significantly abolished by USP14 over-expression.Moreover, our in vivo studies showed that IR-reduced tumor growth and tumor weight were further enhanced by USP14 knockdown in OSCC tumor-bearing nude mice. Finally, we found that USP14 knockdown could promote IR-induced autophagy by increasing LC3BII and γH2AX expression levels in IR-treated OSCC cells. However, this event was markedly abolished by ATG5 knockdown, subsequently restoring the cell proliferation in IR-incubated OSCC cells.Finally, we found that USP14-mediated apoptosis was autophagy-dependent in IR-treated OSCC cells. Taken together, these findings suggested that suppressing USP14 could alleviateradioresistancein OSCC both in vitro and in vivo by inducing apoptosis and autophagy, and thus could be served as a promising therapeutic strategy for OSCC treatment.

60 APPLIED LIFE SCIENCES↗

A multifrequency study of sub-parsec jets with the Event Horizon Telescope

Context. The 2017 observing campaign of the Event Horizon Telescope (EHT) delivered the first very long baseline interferometry (VLBI) images at the observing frequency of 230 GHz, leading to a number of unique studies on black holes and relativistic jets from active galactic nuclei (AGN). In total, eighteen sources were observed, including the main science targets, Sgr A* and M 87, and various calibrators. Sixteen sources were AGN.Aims. We investigated the morphology of the sixteen AGN in the EHT 2017 data set, focusing on the properties of the VLBI cores: size, flux density, and brightness temperature. We studied their dependence on the observing frequency in order to compare it with the Blandford-Königl (BK) jet model. In particular, we aimed to study the signatures of jet acceleration and magnetic energy conversion.Methods. We modeled the source structure of seven AGN in the EHT 2017 data set using linearly polarized circular Gaussian components (1749+096, 1055+018, BL Lac, J0132–1654, J0006–0623, CTA 102, and 3C 454.3) and collected results for the other nine AGN from dedicated EHT publications, complemented by lower frequency data in the 2–86 GHz range. Combining these data into a multifrequency EHT+ data set, we studied the dependences of the VLBI core component flux density, size, and brightness temperature on the frequency measured in the AGN host frame (and hence on the distance from the central black hole), characterizing them with power law fits. We compared the observations with the BK jet model and estimated the magnetic field strength dependence on the distance from the central black hole.Results. Our observations spanning event horizon to parsec scales indicate a deviation from the standard BK model, particularly in the decrease of the brightness temperature with the observing frequency. Only some of the discrepancies may be alleviated by tweaking the model parameters or the jet collimation profile. Either bulk acceleration of the jet material, energy transfer from the magnetic field to the particles, or both are required to explain the observations. For our sample, we estimate a general radial dependence of the Doppler factor δ ∝ r≤0.5. This interpretation is consistent with a magnetically accelerated sub-parsec jet. We also estimate a steep decrease of the magnetic field strength with radius B ∝ r−3, hinting at jet acceleration or efficient magnetic energy dissipation.Key words: techniques: interferometric / galaxies: active / galaxies: jets / galaxies: nuclei / quasars: general / quasars: supermassive black holes⋆⋆ Deceased.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and construction of a new detector to measure ultra-low radioactive-isotope contamination of argon

Large liquid argon detectors offer one of the best avenues for the detection of galactic weakly interacting massive particles (WIMPs) via their scattering on atomic nuclei. The liquid argon target allows exquisite discrimination between nuclear and electron recoil signals via pulse-shape discrimination of the scintillation signals. Atmospheric argon (AAr), however, has a naturally occurring radioactive isotope, 39Ar, a ß emitter of cosmogenic origin. For large detectors, the atmospheric 39Ar activity poses pile-up concerns. The use of argon extracted from underground wells, deprived of 39Ar, is key to the physics potential of these experiments. The DarkSide-20k dark matter search experiment will operate a dual-phase time projection chamber with 50 tonnes of radio-pure underground argon (UAr), that was shown to be depleted of 39Ar with respect to AAr by a factor larger than 1400. Assessing the 39Ar content of the UAr during extraction is crucial for the success of DarkSide-20k, as well as for future experiments of the Global Argon Dark Matter Collaboration (GADMC). This will be carried out by the DArT in ArDM experiment, a small chamber made with extremely radio-pure materials that will be placed at the centre of the ArDM detector, in the Canfranc Underground Laboratory (LSC) in Spain. The ArDM LAr volume acts as an active veto for background radioactivity, mostly ?-rays from the ArDM detector materials and the surrounding rock. This article describes the DArT in ArDM project, including the chamber design and construction, and reviews the background required to achieve the expected performance of the detector.

Noble liquid detectors, Dark Matter detectors, Cry↗

Full-wave modeling of RF waves in fusion plasmas with finite element method: Progress in past decades and its future role

This paper reviews the progress in computing radio frequency (RF) wave fields in fusion plasmas, specifically focusing on simulations utilizing the finite element method (FEM) over the past few decades. Computing RF wave fields in fusion plasmas presents unique challenges due to large simulation domains, complex antenna structures, non-local dielectric properties, and wide ranges of spatial scales. It highlights key developments and outlines future directions, primarily addressing waves in the ion cyclotron (IC) to lower hybrid (LH) frequency range. We begin with briefly revisiting earlier developments before the widespread availability of modern computer-aided engineering (CAE) software based on FEM. This historical perspective illuminates early progress and the physics difficulties that motivated ongoing work within the community. Modern wave simulations for RF antennas based on FEM are characterized by the use of detailed 3D antenna model geometry generated from engineering CAD software and localized wave dielectric model. Significant advancements have also been made in improving physics models to include phenomena such as RF sheath rectification and wave scattering. FEM-based RF simulations have also been applied to compute wave propagation in the core region, where the inclusion of non-local dielectric response is crucial. This is a challenging goal, and several promising approaches have been proposed in this area. Additionally, RF simulation development initiatives based on open-source libraries have gained popularity, demonstrating scalability and flexibility in extending physics models. This paper will discuss the advantages and disadvantages of using such a publicly available FEM library.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Survival and behavior of Mojave desert tortoises head-started with and without outdoor rearing

Mojave desert tortoise (Gopherus agassizii) populations in some regions have declined by >50% since 2004, prompting the need for more research on ways to recover populations. One possible recovery tool is head-starting (i.e., the act of protecting and raising juvenile tortoises to sizes that increase survival upon release); however, head-starting can have high start-up and maintenance costs that can limit its feasibility. Strategies that reduce cost and rearing duration may foster broader and more effective use. We released and radio-tracked 60 juvenile tortoises in the Mojave National Preserve in California, USA, that had been reared under 2 treatments: those reared 1 year indoors after hatching, then 1 year outdoors (combo) and those reared just 1 year indoors (indoor-only). We tested whether indoor-only rearing alone could be a more efficient means of producing robust head-started tortoises. We examined the behavior, movement, and survival of tortoises after release into the wild from 2020 to 2021 to determine whether these outcomes differed between husbandry treatments. Combo tortoises tended to perform settling behaviors (mean ± 1 SE days to building first burrow = 6.7 ± 0.8, entering dormancy = 23.3 ± 2.1, and emerging from dormancy = 189.6 ± 4.4) earlier than indoor-only tortoises (7.4 ± 0.9, 31.5 ± 2.6, and 193.9 ± 5.9, respectively), but this difference was not significant, suggesting the rearing method did not greatly alter settling behavior. Indoor-only tortoises dispersed at least twice as far from their release site (156.2 ± 26.3 m compared with 77.3 ± 20.6 m for combo tortoises), had larger mean use areas (3.7 ± 0.1 ha compared with 2.8 ± 0.3 ha for combo tortoises for 95% Brownian bridge movement model estimates), and greater variability in their movements than combo tortoises (daily average step length post-emergence: 4.3 ± 0.2 m compared with 2.8 ± 0.1 m for combo tortoises). Despite differences in their movements, indoor-only and combo tortoises had similar survival rates over the study, 51% versus 42%, respectively, during a period of extreme drought in 2021. The similarity in survival between groups gives head-starting practitioners freedom in their rearing methods. The indoor-only group had lower site fidelity, which should be considered when this is an undesirable trait for released tortoises.

60 APPLIED LIFE SCIENCES↗

Multiscale X-ray phase contrast imaging of human cartilage for investigating osteoarthritis formation

The evolution of cartilage degeneration is still not fully understood, partly due to its thinness, low radio-opacity and therefore lack of adequately resolving imaging techniques. X-ray phase-contrast imaging (X-PCI) offers increased sensitivity with respect to standard radiography and CT allowing an enhanced visibility of adjoining, low density structures with an almost histological image resolution. This study examined the feasibility of X-PCI for high-resolution (sub-) micrometer analysis of different stages in tissue degeneration of human cartilage samples and compare it to histology and transmission electron microscopy. Ten 10%-formalin preserved healthy and moderately degenerated osteochondral samples, post-mortem extracted from human knee joints, were examined using four different X-PCI tomographic set-ups using synchrotron radiation the European Synchrotron Radiation Facility (France) and the Swiss Light Source (Switzerland). Volumetric datasets were acquired with voxel sizes between 0.7 × 0.7 × 0.7 and 0.1 × 0.1 × 0.1 µm 3 . Data were reconstructed by a filtered back-projection algorithm, post-processed by ImageJ, the WEKA machine learning pixel classification tool and VGStudio max. For correlation, osteochondral samples were processed for histology and transmission electron microscopy. X-PCI provides a three-dimensional visualization of healthy and moderately degenerated cartilage samples down to a (sub-)cellular level with good correlation to histologic and transmission electron microscopy images. X-PCI is able to resolve the three layers and the architectural organization of cartilage including changes in chondrocyte cell morphology, chondrocyte subgroup distribution and (re-)organization as well as its subtle matrix structures. X-PCI captures comprehensive cartilage tissue transformation in its environment and might serve as a tissue-preserving, staining-free and volumetric virtual histology tool for examining and chronicling cartilage behavior in basic research/laboratory experiments of cartilage disease evolution.

3D analysis↗

Stratospheric temperature measurements from nanosatellite stellar occultation observations of refractive bending

Abstract. Stellar occultation observations from space can probe the stratosphere and mesosphere at a fine vertical scale around the globe. Unlike other measurement techniques like radiosondes and aircraft, stellar occultation has the potential to observe the atmosphere above 30 km, and unlike radio occultation, stellar occultation probes fine-scale phenomena with potential to observe atmospheric turbulence. We imaged the refractive bending angle of a star centroid for a series of occultations by the atmosphere. Atmospheric refractivity, density, and then temperature are retrieved from the bending observations with the Abel transformation and Edlén's law, the hydrostatic equation, and the ideal gas law. The retrieval technique is applied to data collected by two nanosatellites operated by Terran Orbital. Measurements were primarily taken by the GEOStare SV2 mission, with a dedicated imaging telescope, supplemented with images captured by spacecraft bus sensors, namely the star trackers on other Terran Orbital missions. The bending angle noise floor is 10 and 30 arcsec for the star tracker and GEOStare SV2 data, respectively. The most significant sources of uncertainty are due to centroiding errors due to the fairly low-resolution stellar images and telescope pointing knowledge derived from noisy satellite attitude sensors. The former mainly affects the star tracker data, while the latter limits the GEOStare SV2 accuracy, with both providing low vertical resolution. This translates to a temperature profile retrieval up to roughly 20 km for both star tracker and GEOStare SV2 datasets. In preparation of an upcoming 2023 mission designed to correct these deficiencies, SOHIP, we simulated bending angle measurements with varying magnitudes of error. The expected maximum altitude of retrieved temperature is 41 km on average for these simulated measurements with a noise floor of 0.39 arcsec. Our work highlights the capabilities of stellar occultation observations from nanosatellites for atmospheric sounding. Future work will investigate high-frequency observations of atmospheric gravity waves and turbulence, mitigating the major uncertainties observed in these datasets.

54 ENVIRONMENTAL SCIENCES↗

A Bayesian Learning Approach to Wireless Outdoor Heatmap Construction using Deep Gaussian Process

We present a novel Bayesian learning approach to outdoor radio heatmap construction utilizing deep Gaussian process (GP). The proposed approach employs a two-layer hierarchy which consists of two cascaded Gaussian processes that are capable of modeling more complex input-output relations than standard single-layer Gaussian processes. Since deriving the exact model likelihood is challenging, a lower bound is optimized instead so that gradient descent-based methods can be performed to find out the optimal model parameters. Typically, inducing points are used in GPs to facilitate low-rank approximation of covariance (kernel) matrices for computation speedup. However, the inaccuracy induced by inducing points can accumulate when stacking multiple layers of GP which may hinder the performance of deep GP. Moreover, since inducing points need to be learned, having them at all layers of deep GP also incurs computational burden. To overcome the above challenges, in contrast to the canonical deep GP model, we use a modified architecture where a full standard GP resides in the first layer and inducing points are only introduced for the second layer. This modified architecture strikes a balance between model accuracy and training complexity. In the proposed model, the noise parameter of the first GP layer is also eliminated to improve the training efficiency as the noise parameter at the output of the second layer suffices to model the uncertainty in the output. The proposed approach is evaluated on real-world datasets, in the form of location-Received Signal Strength (RSS) pairs, collected from the Platform for Open Wireless Data-driven Experimental Research (POWDER) located at the campus of the University of Utah. Experiment results show that the proposed approach can achieve smaller prediction errors on various training and testing data configurations than DNN-based and GP-based methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Tianlai dish array low-z surveys forecasts

Here, we present the science case for surveys with the Tianlai dish array interferometer tuned to the [1300, 1400] MHz frequency range. Starting from a realistic generation of mock visibility data according to the survey strategy, we reconstruct maps of the sky and perform foreground subtraction. We estimate the level of residuals from imperfect subtraction, mostly due to mode mixing, i.e. distortions in the reconstructed 3D maps due to frequency-dependent instrument response. We show that a survey of the North Celestial Polar cap during a year of observations, covering an area of 150 deg 2 , would reach a sensitivity of $1.5-2 mK per 1 MHz x 0.25 2 deg 2 voxel and be marginally impacted by mode mixing. Tianlai would be able to detect ~10 nearby massive H i clumps as well as a very strong cross-correlation signal of 21 cm intensity maps with the North Celestial Cap Survey optical galaxies. We also studied the performance of a mid-latitude survey, covering ~ 1500 deg 2 overlapping the SDSS footprint. Despite a higher noise level for the mid-latitude survey, as well as significant distortions due to mode mixing, Tianlai would be able to detect a highly significant cross-correlation between the 21 cm signal and the Sloan spectroscopic galaxy sample. Using the extragalactic signals measured from either or both of these surveys, and comparing them with simulations such as those presented here will make it possible to assess the impact of various instrumental imperfections on the Tianlai dish array performance. This would pave the way for future intensity mapping surveys with higher sensitivity.

79 ASTRONOMY AND ASTROPHYSICS↗

3D Printable Polymers for Radiological Applications

Additive manufacturing of polymers is a widely used and growing technology throughout the DOE complex. Composite filaments for Fused Deposition Modeling (FDM) printers are commonly used to enhance material properties such as mechanical strength, operating temperature and chemical resistance. Radio luminescent properties were added to 3D filaments by impregnating clear poly(ethylene terephthalate)-glycol (PETG) with X-ray scintillator powder. X-ray scintillators have unique, narrow emission spectra which can be imaged with low light DSLR cameras, photomultiplier tubes, or spectrometers. Filament Production: 1. Pellets are loaded into the hopper. 2. Temperature and extrusion speed are set on extruder. 3. Extruder turned on and filament is pulled from nozzle along air path to cool. 4. Spooler drive speeds set. 5. Filament is inserted through Filameasure then guided along drive wheels and into traverse. 6. Parameters adjusted to obtain 1.75 mm diameter 7. Filament is inserted into spooler wheel. Traverse speed set and slip nut adjusted to make tight and even roll. From Raw Materials to Printed Part: Clear PETG pellets were dipped in ZnS:Cu scintillator powder to coat pellets. Coated and uncoated pellets were mixed together before inserting into hopper. Filament showed trace amounts of powder and luminesced under UV light. Powder distribution is random and not reproducible thus providing a unique identification marker potentially useful for national security applications. Multiple X-ray scintillators can be arranged in a panel to discriminate incident X-ray photon energies. Variable panel arrangement: pixelated, layered, solid from homogenous filament. Ratio of emission intensities. Response varies with incident photon energy. Spectrally separate scintillators. Scintillators: Yttrium Oxide Europium Doped - Red, Gadolinium Oxysulfide Terbium Doped - Green, Barium Magnesium Aluminate Europium Doped - Blue, Zinc Sulfide Copper Doped - Green. Powder concentrations will need to be increased in the filament for use in the energy discriminating panel. Homogeneity in the filament will be a challenge that can be solved by turning the pellets into a powder and mixing it with scintillator powder prior to extrusion. The panels will be tested using x-ray booths and button sources such as Am-241, Cs-137, and Co-60.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Backlighting extended gas halos around luminous red galaxies: Kinematic Sunyaev-Zel’dovich effect from DESI Y1 and ACT data

The gas density profile around galaxies, shaped by feedback and affecting the galaxy lensing signal, is imprinted on the cosmic microwave background (CMB) by the kinematic Sunyaev-Zel’dovich effect (kSZ). We precisely measure this effect (𝑆/𝑁 ≈ 10) via velocity stacking with 825,283 spectroscopically confirmed luminous red galaxies (LRG) from the Dark Energy Spectroscopic Instrument Year 1 (DESI Y1) survey, which overlap with the Atacama Cosmology Telescope (ACT) Data Release 6 temperature maps over ≥ 4,000 deg 2 . We explore the kSZ dependence with various galaxy parameters and find no significant trend with redshift but clear trends with stellar mass and absolute magnitude in 𝑔, 𝑟, and 𝑧 bands. Our analysis suggests that the gas extends beyond the dark matter halo (99.5% confidence level, i.e., probability to exceed (PTE)⁢ = 0.005). We find a tentative preference for hydrodynamical simulation models with stronger feedback that drives gas further out (Illustris 𝑧 = 0.5, PTE⁢ = 0.37) over weaker-feedback cases (IllustrisTNG 𝑧 = 0.8, PTE⁢ = 0.045), though with limited statistical significance. In all cases, a free multiplicative amplitude was fit to the simulated profiles, and further modeling work is required to firm up these conclusions. We find consistency between kSZ profiles around spectroscopic and photometric LRG, with comparable statistical power, thus increasing our confidence in the photometric analysis. Additionally, we present the first kSZ measurement around the DESI Y1 bright galaxy sample (BGS) and the emission-line galaxies (ELG) whose features match qualitative expectations. Finally, we forecast 𝑆/𝑁 ∼ 50 for future stacked kSZ measurements using data from the ACT, the DESI Y3, and the Rubin Observatory. Furthermore, these measurements will serve as an input for galaxy formation models and baryonic uncertainties in galaxy lensing.

79 ASTRONOMY AND ASTROPHYSICS↗

A MHz-repetition-rate hard X-ray free-electron laser driven by a superconducting linear accelerator

The European XFEL is a hard X-ray free-electron laser (FEL) based on a high-electron-energy superconducting linear accelerator. The superconducting technology allows for the acceleration of many electron bunches within one radio-frequency pulse of the accelerating voltage and, in turn, for the generation of a large number of hard X-ray pulses. In this paper, we report on the performance of the European XFEL accelerator with up to 5,000 electron bunches per second and demonstrating a full energy of 17.5 GeV. Feedback mechanisms enable stabilization of the electron beam delivery at the FEL undulator in space and time. The measured FEL gain curve at 9.3 keV is in good agreement with predictions for saturated FEL radiation. Hard X-ray lasing was achieved between 7 keV and 14 keV with pulse energies of up to 2.0 mJ. Using the high repetition rate, an FEL beam with 6 W average power was created.

43 PARTICLE ACCELERATORS↗

The Monte Carlo simulation of the Borexino detector

Borexino is a 300 ton sub-MeV liquid scintillator solar neutrino detector which has been running at the Laboratori Nazionali del Gran Sasso (Italy) since 2007. Thanks to its unprecedented radio-purity, it was able to measure the flux of 7 Be, 8 B, pp, and pep solar neutrinos and to detect geo-neutrinos. A reliable simulation of the detector is an invaluable tool for all Borexino physics analyses. The simulation accounts for the energy loss of particles in all the detector components, the generation of the scintillation photons, their propagation within the liquid scintillator volume, and a detailed simulation of the electronics chain. A novel efficient method for simulating the external background which survives the Borexino passive shield was developed. This technique allows to reliably predict the effect of the contamination in the peripheral construction materials. The techniques developed to simulate the Borexino detector and their level of refinement are of possible interest to the neutrino and dark matter communities, especially for current and future large-volume liquid scintillator experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

AugerPrime surface detector electronics

Operating since 2004, the Pierre Auger Observatory has led to major advances in our understanding of the ultra-high-energy cosmic rays. The latest findings have revealed new insights that led to the upgrade of the Observatory, with the primary goal of obtaining information on the primary mass of the most energetic cosmic rays on a shower-by-shower basis. In the framework of the upgrade, called AugerPrime, the 1660 water-Cherenkov detectors of the surface array are equipped with plastic scintillators and radio antennas, allowing us to enhance the composition sensitivity. To accommodate new detectors and to increase experimental capabilities, the electronics is also upgraded. This includes better timing with up-to-date GPS receivers, higher sampling frequency, increased dynamic range, and more powerful local processing of the data. In this paper, the design characteristics of the new electronics and the enhanced dynamic range will be described. The manufacturing and test processes will be outlined and the test results will be discussed. The calibration of the SD detector and various performance parameters obtained from the analysis of the first commissioning data will also be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗