Results for “radiometric calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Comparison of laboratory calibrations of the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) at the beginning and end of the first flight season

Spectral and radiometric calibrations of the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) were performed in the laboratory in June and November, 1987, at the beginning and end of the first flight season. Those calibrations are described along with changes in instrument characteristics that occurred during the flight season as a result of factors such as detachment of the optical fibers to two of the four AVIRIS spectrometers, degradation in the optical alignment of the spectrometers due to thermally-induced and mechanical warpage, and breakage of a thermal blocking filter in one of the spectrometers. These factors caused loss of signal in three spectrometers, loss of spectral resolution in two spectrometers, and added uncertainty in the radiometry of AVIRIS. Results from in-flight assessment of the laboratory calibrations are presented. A discussion is presented of improvements made to the instrument since the end of the first flight season and plans for the future. Improvements include: (1) a new thermal control system for stabilizing spectrometer temperatures, (2) kinematic mounting of the spectrometers to the instrument rack, and (3) new epoxy for attaching the optical fibers inside their mounting tubes.

Vane, Gregg↗

Comparison of laboratory calibrations of the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) at the beginning and end of the first flight season

Spectral and radiometric calibrations of AVIRIS are described together with changes in instrument characteristics that occurred during the flight season. These changes include detachment of the optical fibers to two of the four AVIRIS spectrometers, degradation in the optical alignment of the spectrometers due to thermally induced and mechanical warpage, and breakage of a thermal blocking filter in one of the spectrometers. Means of improving the instrument are discussed.

Vane, Gregg↗

Emerging Techniques for Vicarious Calibration of Visible Through Short Wave Infrared Remote Sensing Systems

Autonomous Visible to SWIR ground-based vicarious Cal/Val will be an essential Cal/Val component with such a large number of systems. Radiometrically calibrated spectroradiometers can improve confidence in current ground truth data through validation of radiometric modeling and validation or replacement of traditional sun photometer measurement. They also should enable significant reduction in deployed equipment such as equipment used in traditional sun photometer approaches. Simple, field-portable, white-light LED calibration source shows promise for visible range (420-750 nm). Prototype demonstrated <0.5% drift over 10-40 C temperature range. Additional complexity (more LEDs) will be necessary for extending spectral range into the NIR and SWIR. LED long lifetimes should produce at least several hundreds of hours or more of stability, minimizing the need for expensive calibrations and supporting long-duration field campaigns.

Ryan, Robert E.↗

New Approach for Temporal Stability Evaluation of Pseudo-Invariant Calibration Sites (PICS)

Pseudo-Invariant Calibration Sites (PICS) are one of the most popular methods for in-flight vicarious radiometric calibration of Earth remote sensing satellites. The fundamental question of PICS temporal stability has not been adequately addressed. However, the main purpose of this work is to evaluate the temporal stability of a few PICS using a new approach. The analysis was performed over six PICS (Libya 1, Libya 4, Niger 1, Niger 2, Egypt 1 and Sudan 1). The concept of a “Virtual Constellation” was developed to provide greater temporal coverage and also to overcome the dependence limitation of any specific characteristic derived from one particular sensor. TOA reflectance data from four sensors consistently demonstrating “stable” calibration to within 5%—the Landsat 7 ETM+ (Enhanced Thematic Mapper Plus), Landsat 8 OLI (Operational Land Imager), Terra MODIS (Moderate Resolution Imaging Spectroradiometer) and Sentinel-2A MSI (Multispectral Instrument)–were merged into a seamless dataset. Instead of using the traditional method of trend analysis (Student’s T test), a nonparametric Seasonal Mann-Kendall test was used for determining the PICS stability. The analysis results indicate that Libya 4 and Egypt 1 do not exhibit any monotonic trend in six reflective solar bands common to all of the studied sensors, indicating temporal stability. A decreasing monotonic trend was statistically detected in all bands, except SWIR 2, for Sudan 1 and the Green and Red bands for Niger 1. An increasing trend was detected in the Blue band for Niger 2 and the NIR band for Libya 1. These results do not suggest abandoning PICS as a viable calibration source. Rather, they indicate that PICS temporal stability cannot be assumed and should be regularly monitored as part of the sensor calibration process.

Tuli, Fatima Tuz Zafrin↗

SAR calibration - An overview

Remote sensing with synthetic aperture radars (SAR's) is a rapidly developing field. Calibration of these sensors is required for the establishment of relationships between radar backscatter and geographical parameters. A review of recent progress in SAR calibration is presented. The quantities measured by SAR are defined and mathematical formulations of the three basic types of SAR images are developed. The establishment of scientific requirements for calibration and the difficulties involved are discussed. Image quality assessment is reviewed and the problems of radiometric calibration of SAR images using the radar equation and internal and external approaches are considered. Polarimetric radar calibration and the development of the necessary algorithms are described. Interferometric phase calibration and its associated problems are reviewed and future challenges in SAR calibration are discussed.

Freeman, Anthony↗

TM digital image products for applications

Computer compatible tapes (CCTs) of LANDSAT 4 thematic mapper (TM) digital image products are compared and reviewed. The following tape formats are discussed: (1) raw band-sequential data (CCT-BT); (2) calibrated data (CCT-AT); and (3) geometrically resampled data (CCT-PT). Each format represents different steps in the process of producing fully corrected TM data. The CCT-BT images are uncorrected radiometrically or geometrically, CCT-AT data are radiometrically calibrated, and CCT-PT images are both radiometrically and geometrically corrected.

Barker, J. L.↗

Machine processing of ERTS and ground truth data

The author has identified the following significant results. Results achieved by ERTS-Atmospheric Experiment PR303, whose objective is to establish a radiometric calibration technique, are reported. This technique, which determines and removes solar and atmospheric parameters that degrade the radiometric fidelity of ERTS-1 data, transforms the ERTS-1 sensor radiance measurements to absolute target reflectance signatures. A radiant power measuring instrument and its use in determining atmospheric parameters needed for ground truth are discussed. The procedures used and results achieved in machine processing ERTS-1 computer -compatible tapes and atmospheric parameters to obtain target reflectance are reviewed.

Rogers, R. H.↗

Spectroradiometric calibration techniques in the far ultraviolet - A stable emission source for the Lyman bands of molecular hydrogen

The problems associated with making accurate spectroradiometric measurements in the far UV region are sketched briefly. The equipment and methods that were developed for providing absolute sensitivity calibration of an Apollo 17 far UV spectrometer are described. The absolute reference standards were photoelectric diodes calibrated at the National Bureau of Standards. A complete vacuum optical facility, which included a premonochromator and stable UV light sources, was developed to calibrate the Apollo 17 instrument, and it has been used for a number of other tasks. Absolute radiometric calibrations between about 1200 and 1700 A were performed with an absolute accuracy of + or - 10%. The light source, which was designed to provide a very stable light output, is a low-pressure molecular hydrogen lamp in which the pressure is stabilized by thermal control of uranium hydride powder.-

Fastie, W. G.↗

Calibration for the SAGE III/EOS instruments

The calibration plan for the SAGE III instruments for maintaining instrument performance during the Earth Observing System (EOS) mission lifetime is described. The SAGE III calibration plan consists of detailed preflight and inflight calibration on the instrument performance together with the correlative measurement program to validate the data products from the inverted satellite measurements. Since the measurement technique is primarily solar/lunar occultation, the instrument will be self-calibrating by using the sun as the calibration source during the routine operation of the instrument in flight. The instrument is designed to perform radiometric calibration of throughput, spectral, and spatial response in flight during routine operation. Spectral calibration can be performed in-flight from observation of the solar Fraunhofer lines within the spectral region from 290 to 1030 nm wavelength.

Chu, W. P.↗

An Overview of MODIS On-orbit Operation, Calibration, and Lessons

Two nearly identical copies of the Moderate Resolution Imaging Spectroradiometer (MODIS) have successfully operated onboard the Terra and Aqua spacecraft for more than II years and 9 years since their launch in December 1999 and May 2002, respectively. MODIS is a key instrument for the NASA's Earth Observing System (EOS) missions. MODIS observations have produced an unprecedented amount and a broad range of data products and significantly benefited the science and user community. Its follow-on instrument, the Visible/Infrared Imager Radiometer Suite (VIIRS) on-board the NPOESS Preparatory Project (NPP) spacecraft, is currently scheduled for launch in late October, 2011. The NPP serves as a bridge mission between EOS and the Joint Polar Satellite System (JPSS). MODIS collects data in 36 spectral bands, covering spectral regions from visible (VIS) to long-wave infrared (L WIR), and at three different spatial resolutions. Because of its stringent design requirements, MODIS was built with a complete set of onboard calibrators, including a solar diffuser (SO), a solar diffuser stability monitor (SDSM), a blackbody (BB), a spectroradiometric calibration assembly (SRCA), and a space view (SV) port. Except for tbe SRCA, VIlRS carries the same set of onboard calibrators as MODIS. The SD/SDSM system is used together to calibrate tbe reflective solar bands (RSB). The BB is designed for the thermal emissive bands (TEB) calibration. Similar to Terra and Aqua MODIS, VIlRS will also make regular lunar observations to monitor RSB radiometric calibration stability. In this paper, we provide an overview of MODIS on-orbit operation and calibration activities and present issues identified and lessons learned from mission-long instrument operations and implementation of various calibration and characterization strategies. Examples of both Terra and Aqua MODIS instrument on-orbit performance, including their similarities and unique characteristics, are discussed in tbe context of what might be expected from and benefited to tbe NPP VIlRS operation and calibration. It is anticipated that MODIS experience and lessons will also provide valuable information for other earth observing missions/sensors.

Xiong, Jack↗

SL-4 S-190 spectroradiometric accuracy

A procedure used for determining radiometric accuracy, consisting of two phases is presented. In the first phase a sensitometer was used as a calibrated radiometric target; while in the second, the moon was employed. Since the moon is a nonhomogeneous target whose radiometric signature is not as well-known as the irradiants of the sensitometer, the majority of this effort was directed towards the reduction and analysis of the sensitometric data.

Albrizio, R. A.↗

The Use of Transfer Radiometers in Validating the Visible through Shortwave Infrared Calibrations of Radiance Sources Used by Instruments in NASA's Earth Observing System

The detection and study of climate change over a time frame of decades requires successive generations of satellite, airborne, and ground-based instrumentation carefully calibrated against a common radiance scale. In NASA s Earth Observing System (EOS) program, the pre-launch radiometric calibration of these instruments in the wavelength region from 400 nm to 2500 nm is accomplished using internally illuminated integrating spheres and diffuse reflectance panels illuminated by irradiance standard lamps. Since 1995, the EOS Calibration Program operating within the EOS Project Science Office (PSO) has enlisted the expertise of national standards laboratories and government and university metrology laboratories in an effort to validate the radiance scales assigned to sphere and panel radiance sources by EOS instrument calibration facilities. This state-of-the-art program has been accomplished using ultra-stable transfer radiometers independently calibrated by the above participating institutions. In ten comparisons since February 1995, the agreement between the radiance measurements of the transfer radiometers is plus or minus 1.80% at 411 nm, plus or minus 1.31% at 552.5 nm, plus or minus 1.32% at 868.0 nm, plus or minus 2.54% at 1622nm, and plus or minus 2.81% at 2200nm (sigma =1).

Butler, James J.↗

Decade-Long Ozone Profile Record from Suomi NPP OMPS Limb Profiler: Assessment of Version 2.6 Data

We evaluate a decadal ozone profile record derived from the Suomi National Polar-orbiting Partnership (SNPP) Ozone Mapping and Profiler Suite (OMPS) Limb Profiler (LP) satellite instrument. In 2023, the OMPS LP data were re-processed with the new version 2.6 retrieval algorithm that combines measurements from the ultraviolet (UV) and visible (VIS) parts of the spectra and employs the second order Tikhonov regularization to retrieve a single vertical ozone profile between 12.5 km (or cloud tops) and 57.5 km with the vertical resolution of about 1.9 - 2.5 km between 20-55 km. The algorithm uses radiances measured at six UV ozone-sensitive wavelengths (295, 302, 306, 312, 317 and 322 nm) paired with 353 nm, and one VIS wavelength at 606 nm combined with 510 nm and 675 nm to form a triplet. Each wavelength pair or triplet is used over a limited range of tangent altitudes where the sensitivity to ozone changes are strongest. A new implemented aerosol correction scheme is based on a gamma-function particle size distribution. Numerous calibration changes that affected ozone retrievals were also applied to measured LP radiances, including updates in altitude registration, radiometric calibration, stray light, and spectral registration. The key version 2.6 improvement is the reduction in relative drifts between LP ozone and correlative measurements, linked previously to a drift in the version 2.5 LP altitude registration. We compare LP ozone profiles with those from Aura Microwave Limb Sensor (MLS) to quantify ozone changes in version 2.6.

Limb scattering↗

The Precision and Accuracy of AIRS Level 1B Radiances for Climate Studies

We investigate uncertainties in the Atmospheric Infrared Sounder (AIRS) radiances based on in-flight and preflight calibration algorithms and observations. The global coverage and spectra1 resolution ((lamda)/(Delta)(lamda) ~ 1200) of AIRS enable it to produce a data set that can be used as a climate data record over the lifetime of the instrument. Therefore, we examine the effects of the uncertainties in the calibration and the detector stability on future climate studies. The uncertainties of the parameters that go into the AIRS radiometric calibration are propagated to estimate the accuracy of the radiances and any climate data record created from AIRS measurements. The calculated radiance uncertainties are consistent with observations. Algorithm enhancements may be able to reduce the radiance uncertainties by as much as 7%. We find that the orbital variation of the gain contributes a brightness temperature bias of < 0.01 K.

climate↗

Ground and In-Flight Calibration of the OSIRIS-REx Camera Suite

The OSIRIS-REx Camera Suite (OCAMS) onboard the OSIRIS-REx spacecraft is used to study the shape and surface of the mission’s target, asteroid (101955) Bennu,in support of the selection of a sampling site. We present calibration methods and results for the three OCAMS cameras—MapCam, PolyCam, and SamCam—using data from pre-flight and in-flight calibration campaigns. Pre-flight calibrations established a baseline fora variety of camera properties, including bias and dark behavior, flat fields, stray light, and radiometric calibration. In-flight activities updated these calibrations where possible, allowing us to confidently measure Bennu’s surface. Accurate calibration is critical not only for establishing a global understanding of Bennu, but also for enabling analyses of potential sampling locations and for providing scientific context for the returned sample.

E Mazarico↗

Applications of HCMM satellite data

Underflight data were radiometrically calibrated at several locations and surface water temperature measurements were made for several areas approximating the field of view of the HCMM sensor in a study of the thermal properties of Lake Ontario and Lake Erie and of the heat island problem in selected areas adjacent to these lakes. The temperatures obtained from the radiometrically collected imagery were then plotted against the apparent temperatures for these same locations obtained from HCMM computer compatible tapes. The sensor calibration provides a foundation for development of a refined model for radiometric correction of HCMM data to produce maps of thermal bar development in Lake Ontario. Thermal patterns of several urban areas were generated from HCMM tapes and scaled to corresponding land use and topographic maps. The resulting map overlays are being interpreted in terms of land use influence on the extend and severity of heat island indicators.

Source record↗

Time Resolved Irradiance of an Integrating Sphere Illuminated by a Mode-Locked Optical Parametric Oscillator

Tunable laser based illumination sources have been adopted by a number of recent hyperspectral instruments for pre-launch spectral radiometric calibration. Some of these sources use mode-locked cavity configurations, which produce a pulse train and create an undesirable fluctuation in the radiometric source at the mode locking frequency. Although typically this frequency is several orders of magnitude higher than the instrument response, care must be taken to ensure the resultant calibration is not biased due to detector or electronic saturation effects. The temporal averaging properties of an integrating sphere can be used to reduce high frequency fluctuations to an acceptable level. In this work, the time resolved output of an integrating sphere coupled with a mode-locked source was measured. A 76 cm diameter sphere with 30 cm output aperture was illuminated using a mode-locked pulse train at 76 MHz, with single pulse durations of 12 ps. The time constant of the sphere was found to be 36 ns, and the resultant temporal averaging of pulses produced a maximum time varying irradiance at the output of 20% of the mean. The form of this time variance is a sawtooth pattern, with a sharp rise during the introduction of each pulse into the sphere followed by a slower decay between pulses. A comparison of instrument calibration data generated with this integrating sphere using both a mode locked source and a continuous wave source is also given. .

McAndrew, Brendan↗