Vehicle Motions as Inferred from Radio-signal- Strength Records

Considerable data on various parameters of a satellite and its launching vehicle can be obtained from the received-signal-strength records at the various satellite receiver stations. The doppler shifts of the satellite can be used to determine the orbital characteristics quite accurately. (Ref. 1 discusses the rapid determination of these parameters.) Information concerning the velocity increment and direction of each stage can be obtained if doppler data are received by several stations during the high-speed staging. The variations in signal strength during launch can be used to find the spin rate of the satellite before, during, and after staging, and to find variations in attitude, including precession, during launch. With spin and precession frequencies available, any changes in the ratios of moments of inertia can be determined. In this paper the launchings of the Explorer satellites will be used as a basis for the generalized conclusions concerning utilization of radio-signal-strength records. The discussion includes a description of the Explorer launching system.

Pilkington, W. C.↗

Device accurately measures and records low gas-flow rates

Free-floating piston in a vertical column accurately measures and records low gas-flow rates. The system may be calibrated, using an adjustable flow-rate gas supply, a low pressure gage, and a sequence recorder. From the calibration rates, a nomograph may be made for easy reduction. Temperature correction may be added for further accuracy.

Branum, L. W.↗

Run numbering system for use with data recorders

Run numbering identification system provides a permanent identification on the recorder traces of data runs. It automatically enters, by pulse coding, the number of the current data run on the recorder trace. The system uses a keyboard, registers, converters, amplifiers, and a pulse generator.

Pease, L. L.↗

Blood pressure reprogramming adapter assists signal recording

Blood pressure reprogramming adapter separates the two components of a blood pressure signal, a dc pressure signal and an ac Korotkoff sounds signal, so that the Korotkoff sounds are recorded on one channel as received while the dc pressure signal is converted to FM and recorded on a second channel.

Vick, H. A.↗

An improved magnetic tape recorder

Magnetic tape recorder employs a single capstan for simultaneously driving the supply and take-up reels in such a manner that the tape passing between the reels is kept under a predetermined constant tension. This recorder operates with little power and is sufficiently rugged to withstand the severe stresses encountered in high-altitude balloon flight tests.

Uber, P. W.↗

Helical recorder

Tape recorder, using metallic tape, has a minimum of moving parts and no belts. It permits long-term bulk storage in extreme environments, and has less weight and bulk than present recording equipment.

Cole, P. T.↗

Radio frequency baseband recording technique

Technique uses a helical-scan video recorder with auxiliary signal-conditioning equipment to provide an inexpensive, high-capacity magnetic tape recording of a 112 channel, phase-locked, multiplexed, baseband signal.

Heckman, D. C.↗

Optically activated magnetic recording tape

Optically activated data storage medium visually and electromagnetically reproduces a recorded signal. In an electric field, particles in heat-fluidized thermoplastic layer form a visible image of the recorded signal. Refluidizing the thermoplastic layer erases the signals. Very high data packing densities are achieved.

Marks, A. M.↗

Technique minimizes the effects of dropouts on telemetry records

Recorder deficiencies are minimized by using two-channel system to prepare two tapes, each having noise, wow and flutter, and dropout characteristics of channel on which it was made. Processing tapes by computer and combining signals from two channels produce single tape free of dropouts caused by recording process.

Anderson, T. O.↗

Very high speed direct-readout, control and recording system

Characteristics of electronic system for high speed readout, control, and recording of data are discussed. Operation of system is described to show rate of data processing and accuracy obtainable. Primary advantage of system is providing direct recording of parameter value several times per second.

Turner, J. W.↗

Design study for multi-channel tape recorder system, volume 2

Skew test data are presented on a tape recorder transport with a double capstan drive for a 100 KHz tone recorded on five tracks simultaneously. Phase detectors were used to measure the skew when the center channel was the 100 KHz reference.