Search NASA⌕ Search

SEARCH · Search NASA

Results for “reference electrode”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Sensitivity Analysis and Effective Parametrization of PEM Fuel Cell Models

The cost of proton-exchange-membrane fuel cells (PEMFCs) remains a major hurdle in large-scale commercialization of this technology. To improve their performance and reduce cost, novel materials and electrode designs are continuously envisioned, e.g., non-PGM catalyst layers, ultra-thin Pt/Pt-Ni based catalyst layers, structured ionomer arrays or NSTF catalyst layers.1 Understanding the impact of these improvement strategies can be extremely time and cost intensive due to complex physical phenomena and large design space. We have previously developed a PEMFC modeling framework2 which has been a time and cost effective tool for understanding and optimizing the complex multi-physics phenomena within PEMFCs; however, several of the cell parameters used in the modeling have large spread in measured data.3 Furthermore, several transport parameters such as water adsorption kinetics have not been accurately measured and the approximations are spread over several orders of magnitude. These uncertainties cause problems in ascertaining accuracy of the modeling approach and they reduce the predictive power of the numerical models. The aim of this work is to identify the sensitivity of PEFC numerical model outputs to various input parameters. The previously in-house developed MEA modeling framework2 is used for PEMFC modeling. The sensitivity of the model outputs with respect to inputs parameters is obtained by analyzing the condition numbers for different output-input pairs at varying operating conditions. An example of the sensitivity analysis is shown in Figure 1. The condition numbers are obtained for the entire possible range of input parameters at varying operating conditions to identify the most crucial parameters of the PEMFC model. Based on our preliminary analysis, parameters related to kinetics (exchange current density and ECSA) and heat/water management in electrodes and ionomer (ionomer fraction, thermal conductivity) are most crucial. One of the major goals of this work is to identify the most crucial set of parameters towards which the model shows maximum sensitivity. This will guide future experimentalists to measure these properties with higher accuracy. Furthermore, the sensitivity analysis will also enable us to optimize the PEMFC performance by selectively targeting the most sensitive parameters and thereby making the largest impact. Acknowledgements The work is funded under the Fuel Cell Performance and Durability Consortium (FC-PAD), by the Fuel Cell Technologies Office (FCTO), Office of Energy Efficiency and Renewable Energy (EERE), of the U.S. Department of Energy under contract number DE-AC02-05CH11231. The authors would like to thank Nathan Craig at Robert Bosch LLC for his valuable input in designing the sensitivity analysis. The authors would also like to thank Giovanna Bucci and Matthias Hanauer at Robert Bosch for their valuable inputs and discussion. References P. K. Sinha, W. Gu, A. Kongkanand and E. Thompson, J. Electrochem. Soc., 158, B831 (2011). L. M. Pant, M. R. Gerhardt, N. Macauley, R. Mukundan, R. L. Borup and A. Z. Weber, Electrochim. Acta, 326, 134963 (2019). R. Vetter and J. O. Schumacher, ArXiv181110091 Phys. (2018). Figure 1

Pant, Lalit↗

Validation test of advanced technology for IPV nickel-hydrogen flight cells - Update

Individual pressure vessel (IPV) nickel-hydrogen technology was advanced at NASA Lewis and under Lewis contracts with the intention of improving cycle life and performance. One advancement was to use 26 percent potassium hydroxide (KOH) electrolyte to improve cycle life. Another advancement was to modify the state-of-the-art cell design to eliminate identified failure modes. The modified design is referred to as the advanced design. A breakthrough in the LEO cycle life of IPV nickel-hydrogen cells has been previously reported. The cycle life of boiler plate cells containing 26 percent KOH electrolyte was about 40,000 LEO cycles compared to 3,500 cycles for cells containing 31 percent KOH. The boiler plate test results are in the process of being validated using flight hardware and real time LEO testing. The primary function of the advanced cell is to store and deliver energy for long-term, LEO spacecraft missions. The new features of this design are: (1) use of 26 percent rather than 31 percent KOH electrolyte; (2) use of a patented catalyzed wall wick; (3) use of serrated-edge separators to facilitate gaseous oxygen and hydrogen flow within the cell, while still maintaining physical contact with the wall wick for electrolyte management; and (4) use of a floating rather than a fixed stack (state-of-the-art) to accommodate nickel electrode expansion due to charge/discharge cycling. The significant improvements resulting from these innovations are: extended cycle life; enhanced thermal, electrolyte, and oxygen management; and accommodation of nickel electrode expansion.

Smithrick, John J.↗

Indirect Magnetic Measurements on the Aerodynamic Heating Facility (AHF)

The arc jet complex at NASA Ames Research Center (ARC) investigates various thermal protection systems (TPS) and their performance in high enthalpy flow environments to improve heat shields used in atmospheric entry. The arc jet operates by inducing an arc between two electrodes and passing the heated gas through a supersonic nozzle. The arc plasma is typically a partially ionized air mixture at low temperature (< 2 eV) but operates for long periods of time (up to 30 min) at high power (< 60 MW). However, simulations using the in-house ARC Heater Simulator (ARCHeS) code predict that the arc is still unstable to MHD instabilities, primarily the kink instability, which limit the operational envelope of the facility [1]. Consequently, it is important to better characterize these instabilities to improve facility stability and extend operational ranges. Due to the high enthalpy and long timescales (i.e., minutes) arc diagnostics must be non-invasive (i.e., optical or magnetic). This work will cover the development of tri-axial magnetic hall sensors for arc jet instabilities and subsequent 3D characterization of arc motion. The latest results describing the kink instability amplitude, frequency and wavelength will be presented and represent the first measurements of this instability in a NASA arc jet facility. References: [1] Meurisse, J. (2018). 3D Unsteady Model of Arc Heater Plasma Flow Using the ARC Heater Simulator (ARCHeS), APS Gaseous Electronics Conference, 2018: APS.

Sebastian Vicente Colom↗

Modeling of Orbital and Attitude Dynamics of Nanosatellites Controlled via Active Electrostatic Charging

The large-scale exploration of airless bodies, such as asteroids and moons, is gaining interest, however it is limited by mobility issues: the lack of atmosphere, low gravity, and unknown soil properties pose difficult challenges for many forms of traditional locomotion. The environment in proximity of these bodies is also electrically charged due to interactions with solar wind and UV radiation. The EGlider (Electrostatic Glider) concept would be able to overcome these mobility issues by leveraging the natural environment, allowing operations in close proximity of the surface, while enabling long duration missions by minimizing propellant consumption. The EGlider is an advanced concept for small satellite mobility and propulsion, which relies on the electric fields naturally present around airless bodies in order to generate forces and torques useful for maneuvering. It does so by extending electrically charged appendages, which enable it to electrostatically soar above the surface. By differentially charging its electrodes it can also produce torques to control its attitude. The charges are maintained by continuous active ion or electron emission from the spacecraft, in order to cancel out the neutralizing influx of charges from surrounding plasma. An investigation of the spacecraft-plasma interaction was carried out. This included studying the effect of electrode geometry and calculating the charge-to-mass ratios required to enable several mission scenarios. Long, thin wire electrodes were identified to be the most power-efficient and would allow power-to-weight ratios achievable with current nanosatellite technologies. High electrode potential represents the main limiting factor for the system design. In order to test the feasibility of active control by means of differential charging, a simple 2D interaction model was developed, and a feedback controller to stabilize the vehicle was tested in a simulation environment. The results confirmed that good performance could be obtained for both position and attitude control. Finally, a dedicated software was developed for future simulation and testing of control strategies for the EGlider. This software allows to study the trajectory and attitude of an arbitrarily configured spacecraft in the proximity of an arbitrarily defined main airless body. The spacecraft can be assembled from basic parts, each with specified electrical, mass and optical properties. Efficient models allow to calculate gravitational and electrical interactions with the rotating main body and the local plasma field, as well as solar radiation pressure effects. Control models can be implemented as simple plug-in functions and easily tested. The preliminary validation campaign showed good matching with the reference cases that have been analyzed.

Corpino, Sabrina↗

Phase-Selective Epitaxial Growth of Heterophase Nanostructures on Unconventional 2H-Pd Nanoparticles

Heterostructured, including heterophase, noble-metal nanomaterials have attracted much interest due to their promising applications in diverse fields. However, great challenges still remain in the rational synthesis of well-defined noble-metal heterophase nanostructures. Furthermore, we report the preparation of Pd nanoparticles with an unconventional hexagonal close-packed (2H type) phase, referred to as 2H-Pd nanoparticles, via a controlled phase transformation of amorphous Pd nanoparticles. Impressively, by using the 2H-Pd nanoparticles as seeds, Au nanomaterials with different crystal phases epitaxially grow on the specific exposed facets of the 2H-Pd, i.e., face-centered cubic (fcc) Au (fcc-Au) on the (002)h facets of 2H-Pd while 2H-Au on the other exposed facets, to achieve well-defined fcc-2H-fcc heterophase Pd@Au core–shell nanorods. Moreover, through such unique facet-directed crystal-phase-selective epitaxial growth, a series of unconventional fcc-2H-fcc heterophase core–shell nanostructures, including Pd@Ag, Pd@Pt, Pd@PtNi, and Pd@PtCo, have also been prepared. Impressively, the fcc-2H-fcc heterophase Pd@Au nanorods show excellent performance toward the electrochemical carbon dioxide reduction reaction (CO 2 RR) for production of carbon monoxide with Faradaic efficiencies of over 90% in an exceptionally wide applied potential window from –0.9 to –0.4 V (versus the reversible hydrogen electrode), which is among the best reported CO 2 RR catalysts in H-type electrochemical cells.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electrochemically driven carbon dioxide separation

This project explored the viability of a Ni(OH) 2 based hydroxide exchange membrane carbon capture (HEMCC) device for direct air capture. It is built off an H 2 fuel cell based HEMCC previously developed in the Yushan Yan group at University of Delaware. Taking the same membrane-based, electrochemically driven pH gradient concept, similar flux performance was able to be seen in the Ni(OH) 2 system as the H 2 system when using comparable current densities. The project produced two types of membrane electrode assemblies (MEA). The first was a traditional MEA with two electrodes and a membrane, the second was a flow-through membrane MEA. Consistent performance was achieved with the traditional MEA with an energy cost of 1.1 MWh∙ton -1 and flux of 82 kg∙m -2 ∙yr -1 . This was the most stable of the two designs. This project investigated strategies to improve performance with a flow-through membrane design. Two designs were made, one with a cast phase inversion membrane, and one with powdered membrane layer. The template phase inversion membrane achieved low pressure drop but had performance limitations due to a skin layer of membrane limiting CO 2 gas transport. The powdered membrane layer had better performance but higher pressure drop. Finally, using the powdered membrane, commercial battery materials were able to be used in order to achieve higher flux. This showed that the flow through membrane design does have the capability to overcome flux inefficiencies in the traditional MEA. Moreover, the process design of the system is proposed and given in this project. The process mass and energy balances were calculated for a reference plant of 1000 t/yr CO 2 capture, which contains several subsystems, e.g. air processing subsystem, electrical subsystem, and CO 2 purification and compression subsystem is designed and evaluated. Based on our calculation, When the power consumption for stack is 1 MWh t -1 CO 2 , Additional 382 kWh t -1 CO 2 will be consumed by other subsystem of the plant, i.e. The total power consumption of 1.38 MWh t -1 CO 2 , lower than the final milestone of 1.5 MWh t -1 CO 2 in this project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Micrometer to Atomic Scale Characterisation of Primitive Astromaterials Using A Novel Method, Metis-Fa: A Coordinated Atom Probe Tomography, Transmission Electron Microscopy and NanoSIMS Approach

Introduction: Presolar grains preserve isotopic, chemical and microstructural records of physical and chemical processing, and formation mechanisms within a vast range of evolved stellar systems, the interstellar medium, solar nebula and their parent bodies. These evolutionary records are preserved at the micrometric to atomic scale, requiring coordinated studies to expand our understanding of evolutionary processes occurringthroughout ours and external stellar systems [1]. NanoSIMS enabled rapid in situ identification and isotopic characterisation of presolar grains and their stellar origins using 17O/16O and 18O/16O, and 13C/12C isotopic ratios [1]. Coordination with transmission electron microscopy (TEM) revealed crystallographic and localised contextual relationships and quantitively constrained their major and minor compositions [1]. However, trace elements cannot be quantified, the most sensitive geochemical tracers of environmental conditions, essential to unravelling the chemical record of their evolutionary pathway and parent stellar systems [2-3] . Furthermore, owing to the combination of technical limitations (only 5 – 7 isotopes can be measured per NanoSIMS run) and their small grain sizes of 100 nm < 3 μm (with rare exceptions in nanodiamonds (2 nm ≤) and SiC (< 40 μm)), the number of measurable isotopes per grain volume is limited [1,3] . Through more comprehensive isotopic studies of presolar grains, NanoSIMS studies have shown the importance of the latter, identifying Fe and Mg as important indicators of nuclear synthetic processing and their stellar origins, respectively [4- 5]. Coordination of NanoSIMS and Atom Probe Tomography (APT) revealed morphological signatures, and isotopic and chemical signatures at major to trace levels without requirements for preselection of elements [6]. However, crystallographic signatures in localized contextual relationships cannot be measured. Consequently, coordination of NanoSIMS, TEM and APT is essential to gain access to almost all contextual, structural and geochemical signatures within each presolar grain.Transmission electron microscopy requires a 100 nm thin lamella which is unstable in APT and would not produce any viable data. Atom probe tomography requires a needle-shaped specimen which when measured in TEM removes the local context, impacts the quality of the TEM diffraction images due to the shank angle of the needle, and can alter the chemistry of beam sensitive materials from the higher degree of surface exposure at the tip. To address these issues, we developed METIS-Fa (Multi-technical measurements of Electron Transparent materials using an Indium Sandwich - a FIB approach). A novel method which enables coordination of NanoSIMS, TEM and APT for generalized and targeted studies of individual grains, including beam sensitive materials, without compromising sample preparation requirements for TEM and APT. This method requires only indium and a Focus Ion Beam (FIB), minimizing the movement of fragile materials while still enabling preparation of TEM lamella into APT needles. Samples: Initial experimental development and testing of the method occurred at Astromaterials Research and Exploration Science (ARES), Johnson Space Centre (JSC), NASA and APT measurements and needle preparation occurred at JdLC, Curtin University. Synthetic silicate samples were used as analogs for presolar silicates when performing a trial run of the method. Samples were extracted from a polished thin section created at JSC, NASA, comprised of 38 wt.% Si, 17 wt.% FeO, 13 wt.% MgO, 12 wt.% Al, 11 wt.% Ca based on electron microprobe analysis (EMPA) [8] . Experimental details, pressure and temperature conditions were presented in [8] and references therein. Testing of the capability to target individual grains in mineral matrices using this method for acquisition in APT, measured matrix regions in meteoritic thin sections of primitive meteorites. These meteorites and their identified presolar grains for future targeted studies are detailed in [9]. Techniques: The TEM-FIB lamella were prepared using a FIB. An e-beam assisted pt deposition was used as a protective coating for the synthetic and meteoritic samples. When targeting individual grains, a secondary e-beam assisted pt deposition button is placed over the desired grain before the protective coating to denote its location. A JEOL 2500SE field-emission TEM was used for high-resolution imaging, energy-dispersive X-ray (EDX) and electron diffraction data.TheMETIS-Fa method was experimentally designed, tested and executed using a FIB at ARES, JSCNASA. Needles for APT were prepared using the Tescan Lyra3 GM Dual Beam Focus Ion Beam (FIB) Field Emission SEM (FE-SEM) at the JdLC, Curtin University. Atom probe tomography measurements were conducted using a CAMECA Local Electrode Atom Probe, LEAP 4000X HR. Two pure indium needles were analyzed initially to constraining acquisition parameters and stability under the beam. Manual acquisition was required to maintain evaporation of specimen’s at the apex and monitor interactions with measurement parameters. Experimental Design: Indium foil is pressed onto an Al stub with a pneumatic press and mounted into the FIB adjacent to the TEM-FIB lamella of interest. Using a FIB, two indium slices (5 μm x ~300 nm x 3 μm) are extracted from indium foil and aligned with the TEM-FIB lamella before touching the TEM-FIB lamella. Each slice is then attached through cold welding to the FIB-TEM lamella. This approach eliminates the need for chemical treatments and proved effective for aligning the Indium within the region of interest for APT, holding it in place for up to 4 days during testing.Once both indium slices are attached within their pre-determined region per grain targeting requirements, they are gradually melted onto the FIB-TEM lamella.When targeting a specific grain, measurements should be taken of the pt button and its distance from edge to edge of the lamella before and after sandwiching. A secondary button should be placed over the same region after the Indium slices have been attached to improve precision when preparing APT needles. Results: Figure 1 shows two indium slices melted onto a FIB-TEM lamella, adding additional bulk for preparation into APT needles as shown in Figure 2 [7] . The latter was essential so samples could be measured in TEM and APT without compromising sample preparation requirements and consequently data quality and acquisition stability. METIS-Fa proved effective forimproving geometry. Figure 3 shows a successful APTrun of the synthetic silicate. EMPA, TEM and APTshowed no chemical alterations. During targetingtesting, a solar silicate grain was successfully identifiedand measured in TEM, and prepared into an APTneedle. However, the indium was melted too long during sample preparation, causing expansion andformation of internal porosity leading to sample loss.Conclusion: METIS-Fa greatly expands the number of isotopic and chemical signatures measured per grain volume, and enables measurements of contextual, structural, crystallographic, isotopic and geochemical signatures within individual grains. Gaining access to such a vast range of evolutionary signatures required for expanding our understanding of external stellar and planetary systems and the evolution of our solar system. This method was designed for application to a vast range of phases including being sensitive materials and thus provides a way for coordination of NanoSIMS, TEM and APT not just for the study of presolar grains and by extension primitive astromaterials, but studies in a vast range of other fields including the geosciences and material sciences.Acknowledgments: Thankyou to ARES, JSC, NASA; JdLC Curtin University and Space Science Technology Centre for the use of laboratory facilities and funding [confirm].

Nicole D Nevill↗

Self-Nulling Lock-in Detection Electronics for Capacitance Probe Electrometer

A multi-channel electrometer voltmeter that employs self-nulling lock-in detection electronics in conjunction with a mechanical resonator with noncontact voltage sensing electrodes has been developed for space-based measurement of an Internal Electrostatic Discharge Monitor (IESDM). The IESDM is new sensor technology targeted for integration into a Space Environmental Monitor (SEM) subsystem used for the characterization and monitoring of deep dielectric charging on spacecraft. Use of an AC-coupled lock-in amplifier with closed-loop sense-signal nulling via generation of an active guard-driving feedback voltage provides the resolution, accuracy, linearity and stability needed for long-term space-based measurement of the IESDM. This implementation relies on adjusting the feedback voltage to drive the sense current received from the resonator s variable-capacitance-probe voltage transducer to approximately zero, as limited by the signal-to-noise performance of the loop electronics. The magnitude of the sense current is proportional to the difference between the input voltage being measured and the feedback voltage, which matches the input voltage when the sense current is zero. High signal-to-noise-ratio (SNR) is achieved by synchronous detection of the sense signal using the correlated reference signal derived from the oscillator circuit that drives the mechanical resonator. The magnitude of the feedback voltage, while the loop is in a settled state with essentially zero sense current, is an accurate estimate of the input voltage being measured. This technique has many beneficial attributes including immunity to drift, high linearity, high SNR from synchronous detection of a single-frequency carrier selected to avoid potentially noisy 1/f low-frequency spectrum of the signal-chain electronics, and high accuracy provided through the benefits of a driven shield encasing the capacitance- probe transducer and guarded input triaxial lead-in. Measurements obtained from a 2- channel prototype electrometer have demonstrated good accuracy (|error| < 0.2 V) and high stability. Twenty-four-hour tests have been performed with virtually no drift. Additionally, 5,500 repeated one-second measurements of 100 V input were shown to be approximately normally distributed with a standard deviation of 140 mV.

Blaes, Brent R.↗

On the perturbation effect and LET dependence of beam quality correction factors in carbon ion beams

Background: In a recent study, we reported beam quality correction factors, f Q , in carbon ion beams using Monte Carlo (MC) methods for a cylindrical and a parallel-plate ionization chamber (IC). A non-negligible perturbation effect was observed; however, the magnitude of the perturbation correction due to the specific IC subcomponents was not included. Furthermore, the stopping power data presented in the International Commission on Radiation Units and Measurements (ICRU) report 73 were used, whereas the latest stopping power data have been reported in the ICRU report 90. Purpose: The aim of this study was to extend our previous work by computing f Q correction factors using the ICRU 90 stopping power data and by reporting IC-specific perturbation correction factors. Possible energy or linear energy transfer (LET) dependence of the f Q correction factor was investigated by simulating both pristine beams and spread-out Bragg peaks (SOBPs). Methods: The TOol for PArticle Simulation (TOPAS)/GEANT4 MC code was used in this study. A 30 × 30 × 50 cm 3 water phantom was simulated with a uniform 10 × 10 cm 2 parallel beam incident on the surface. A Farmer-type cylindrical IC (Exradin A12) and two parallel-plate ICs (Exradin P11 and A11) were simulated in TOPAS using the manufacturer-provided geometrical drawings. The f Q correction factor was calculated in pristine carbon ion beams in the 150–450 MeV/u energy range at 2 cm depth and in the middle of the flat region of four SOBPs. The k Q correction factor was calculated by simulating the f Qo correction factor in a 60 Co beam at 5 cm depth. The perturbation correction factors due to the presence of the individual IC subcomponents, such as the displacement effect in the air cavity, collecting electrode, chamber wall, and chamber stem, were calculated at 2 cm depth for monoenergetic beams only. Additionally, the mean dose-averaged and track-averaged LET was calculated at the depths at which the f Q was calculated. Results: The ICRU 90 f Q correction factors were reported. The p dis correction factor was found to be significant for the cylindrical IC with magnitudes up to 1.70%. The individual perturbation corrections for the parallel-plate ICs were <1.0% except for the A11 p cel correction at the lowest energy. The f Q correction for the P11 IC exhibited an energy dependence of >1.00% and displayed differences up to 0.87% between pristine beams and SOBPs. Conversely, the f Q for A11 and A12 displayed a minimal energy dependence of <0.50%. The energy dependence was found to manifest in the LET dependence for the P11 IC. A statistically significant LET dependence was found only for the P11 IC in pristine beams only with a magnitude of <1.10%. Conclusions: The perturbation and k Q correction factor should be calculated for the specific IC to be used in carbon ion beam reference dosimetry as a function of beam quality.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Validation test of advanced technology for IPV nickel-hydrogen flight cells: Update

Individual pressure vessel (IPV) nickel-hydrogen technology was advanced at NASA Lewis and under Lewis contracts with the intention of improving cycle life and performance. One advancement was to use 26 percent potassium hydroxide (KOH) electrolyte to improve cycle life. Another advancement was to modify the state-of-the-art cell design to eliminate identified failure modes. The modified design is referred to as the advanced design. A breakthrough in the low-earth-orbit (LEO) cycle life of IPV nickel-hydrogen cells has been previously reported. The cycle life of boiler plate cells containing 26 percent KOH electrolyte was about 40,000 LEO cycles compared to 3,500 cycles for cells containing 31 percent KOH. The boiler plate test results are in the process of being validated using flight hardware and real time LEO testing at the Naval Weapons Support Center (NWSC), Crane, Indiana under a NASA Lewis Contract. An advanced 125 Ah IPV nickel-hydrogen cell was designed. The primary function of the advanced cell is to store and deliver energy for long-term, LEO spacecraft missions. The new features of this design are: (1) use of 26 percent rather than 31 percent KOH electrolyte; (2) use of a patented catalyzed wall wick; (3) use of serrated-edge separators to facilitate gaseous oxygen and hydrogen flow within the cell, while still maintaining physical contact with the wall wick for electrolyte management; and (4) use of a floating rather than a fixed stack (state-of-the-art) to accommodate nickel electrode expansion due to charge/discharge cycling. The significant improvements resulting from these innovations are: extended cycle life; enhanced thermal, electrolyte, and oxygen management; and accommodation of nickel electrode expansion. The advanced cell design is in the process of being validated using real time LEO cycle life testing of NWSC, Crane, Indiana. An update of validation test results confirming this technology is presented.

Smithrick, John J.↗

Solving the Pulsed-Power Driven Inertial Fusion Energy Standoff Problem (Abbreviated Final Report)

The standoff problem in pulsed-power driven IFE (Inertial Fusion Energy) refers to the problem of electrically connecting a fusion target with the driver in a way that preserves the driver/target interface in the presence of a large fusion energy release (100’s of megajoules to 1000 megajoules). High yield fusion drivers for stockpile stewardship applications have similar concerns, but without the complication of the high repetition rate needed for energy production. All proposed IFE or high yield systems have the challenge of protecting the reactor vessel and driver from the energy release, but pulsed power drivers have the additional challenge of establishing an electrical connection in a way that does not create excessive debris or require costly/massive structures that must be expendable. Fortunately, there are conceptual solutions in the form of very low mass transmission lines, usually in the form of wires or foils, since very little mass is needed to overcome the magnetic forces driving the transmission lines apart or provide a low resistance pathway given the short pulse duration of the driver. Several important aspects of the standoff problem were analyzed in the course of this LDRD project. Conceptual means of introducing the low mass transmission lines into the reactor chamber were proposed, including analysis of methods to retain the power flow gap between the electrodes in the presence of the chamber environment. The energy losses due to ohmic dissipation and magnetic acceleration of the low mass transmission lines were evaluated for candidate driver pulses and different transmission line masses, and the fluence of x-ray and neutron energy on the persistent power flow structures that must survive the pulse of energy were evaluated. Finally, means of rapidly pumping down the chamber were explored as a way to return the system to low pressure following the multi-atmosphere post-pulse pressure rise. The overall conclusion from the analysis is that, while the reactor environment creates stressful conditions for a low mass transmission line standoff system, there are concepts expending 10 kg or less of electrode mass each pulse with the potential to mitigate the stresses and successfully drive fusion targets. Whether such a system could lead to a practical and economical fusion reactor would require extensive research and development beyond the scope of the feasibility study.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Hippocampal place-cell firing during movement in three-dimensional space

"Place" cells of the rat hippocampus are coupled to "head direction" cells of the thalamus and limbic cortex. Head direction cells are sensitive to head direction in the horizontal plane only, which leads to the question of whether place cells similarly encode locations in the horizontal plane only, ignoring the z axis, or whether they encode locations in three dimensions. This question was addressed by recording from ensembles of CA1 pyramidal cells while rats traversed a rectangular track that could be tilted and rotated to different three-dimensional orientations. Cells were analyzed to determine whether their firing was bound to the external, three-dimensional cues of the environment, to the two-dimensional rectangular surface, or to some combination of these cues. Tilting the track 45 degrees generally provoked a partial remapping of the rectangular surface in that some cells maintained their place fields, whereas other cells either gained new place fields, lost existing fields, or changed their firing locations arbitrarily. When the tilted track was rotated relative to the distal landmarks, most place fields remapped, but a number of cells maintained the same place field relative to the x-y coordinate frame of the laboratory, ignoring the z axis. No more cells were bound to the local reference frame of the recording apparatus than would be predicted by chance. The partial remapping demonstrated that the place cell system was sensitive to the three-dimensional manipulations of the recording apparatus. Nonetheless the results were not consistent with an explicit three-dimensional tuning of individual hippocampal neurons nor were they consistent with a model in which different sets of cells are tightly coupled to different sets of environmental cues. The results are most consistent with the statement that hippocampal neurons can change their "tuning functions" in arbitrary ways when features of the sensory input or behavioral context are altered. Understanding the rules that govern the remapping phenomenon holds promise for deciphering the neural circuitry underlying hippocampal function.

Non-NASA Center↗

NASA Tech Briefs, October 2007

Topics covered include; Wirelessly Interrogated Position or Displacement Sensors; Ka-Band Radar Terminal Descent Sensor; Metal/Metal Oxide Differential Electrode pH Sensors; Improved Sensing Coils for SQUIDs; Inductive Linear-Position Sensor/Limit-Sensor Units; Hilbert-Curve Fractal Antenna With Radiation- Pattern Diversity; Single-Camera Panoramic-Imaging Systems; Interface Electronic Circuitry for an Electronic Tongue; Inexpensive Clock for Displaying Planetary or Sidereal Time; Efficient Switching Arrangement for (N + 1)/N Redundancy; Lightweight Reflectarray Antenna for 7.115 and 32 GHz; Opto-Electronic Oscillator Using Suppressed Phase Modulation; Alternative Controller for a Fiber-Optic Switch; Strong, Lightweight, Porous Materials; Nanowicks; Lightweight Thermal Protection System for Atmospheric Entry; Rapid and Quiet Drill; Hydrogen Peroxide Concentrator; MMIC Amplifiers for 90 to 130 GHz; Robot Would Climb Steep Terrain; Measuring Dynamic Transfer Functions of Cavitating Pumps; Advanced Resistive Exercise Device; Rapid Engineering of Three-Dimensional, Multicellular Tissues With Polymeric Scaffolds; Resonant Tunneling Spin Pump; Enhancing Spin Filters by Use of Bulk Inversion Asymmetry; Optical Magnetometer Incorporating Photonic Crystals; WGM-Resonator/Tapered-Waveguide White-Light Sensor Optics; Raman-Suppressing Coupling for Optical Parametric Oscillator; CO2-Reduction Primary Cell for Use on Venus; Cold Atom Source Containing Multiple Magneto- Optical Traps; POD Model Reconstruction for Gray-Box Fault Detection; System for Estimating Horizontal Velocity During Descent; Software Framework for Peer Data-Management Services; Autogen Version 2.0; Tracking-Data-Conversion Tool; NASA Enterprise Visual Analysis; Advanced Reference Counting Pointers for Better Performance; C Namelist Facility; and Efficient Mosaicking of Spitzer Space Telescope Images.

Source record↗

Ultra‐Thin Single‐Particle‐Layer Sodium Beta‐Alumina‐Based Composite Polymer Electrolyte Membrane for Sodium‐Metal Batteries

Inorganic/organic composite polymer electrolytes (CPEs) with good flexibility and electrode contact have been pursued for solid-state sodium-metal batteries. However, the application of CPEs for high energy density solid-state sodium-metal batteries is still limited by the low Na + conductivity, large thickness, and low ion transference number. Herein, an ultra-thin single-particle-layer (UTSPL) composite polymer electrolyte membrane with a thickness of ≈20 µm straddled by a sodium beta-alumina ceramic electrolyte (SBACE) is presented. A ceramic Na + -ion electrolyte that bridges or percolates across an ultra-thin and flexible polymer membrane provides: 1) the strength and flexibility from the polymer membrane, 2) excellent electrolyte/electrode interfacial contact, and 3) a percolation path for Na + -ion transfer. Owing to this novel design, the obtained UTSPL-35SBACE membrane exhibits a high Na+-ion conductivity of 0.19 mS cm -1 and a transference number of 0.91 at room temperature, contributing to long-term cycling stability of symmetric sodium cells with a small overpotential. The assembled quasi-solid-state cell with the as-prepared UTSPL-35SBACE membrane displays superior cycling performance with a discharge capacity of 105 mAh g -1 at 0.5 °C rate after 100 cycles and excellent rate performance (82 mAh g -1 at 5 °C rate) at room temperature with the potassium manganese hexacyanoferrate (KMHCF)@CNTs/CNFs cathode, where KMHCF refers to potassium manganese hexacyanoferrate.

25 ENERGY STORAGE↗

Thin Cation-Exchange Layers Enable High-Current-Density Bipolar Membrane Electrolyzers via Improved Water Transport

With suitable water dissociation (WD) catalysts, bipolar membranes (BPMs) can efficiently dissociate water into H + and OH – at the junction between anion- and cation-exchange layers (AEL and CEL, respectively). First, however, water must be transported through the AEL or CEL and thus against the outward flow of hydrated H + and OH – . This is a challenge intrinsic to the BPM architecture and limits operation to current densities typically less than ~0.5 A·cm –2 . Here we explore how water transport affects durability and performance in reference alkaline and acidic membrane electrolyzers, and we use the insight gained to design BPMs with improved water transport. We demonstrate a thin-CEL BPM (2-μm Nafion CEL|~200 nm TiO 2 |~200 nm NiO + ionomer|50 μm Sustainion AEL) which maintains a pH difference of ~14 units between the anode and cathode for current densities of up to 3.4 A·cm –2 with a total water electrolysis voltage of ~4 V and an estimated WD overpotential of ~1.5 V. Finally, such high-current-density operation is crucial for key emerging BPM applications, including in water and carbon-dioxide electrolyzers and in (regenerative) fuel cells.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Macroscale and Nanoscale Photoelectrochemical Behavior of p-Type Si(111) Covered by a Single Layer of Graphene or Hexagonal Boron Nitride

Two-dimensional (2D) materials may enable a general approach to the introduction of a dipole at a semiconductor surface as well as control over other properties of the double layer at a semiconductor/liquid interface. Vastly different properties can be found in the 2D materials currently studied due in part to the range of the distribution of density-of-states. In this work, the open-circuit voltage (V oc ) of p-Si–H, p-Si/Gr (graphene), and p-Si/h-BN (hexagonal boron nitride) in contact with a series of one-electron outer-sphere redox couples was investigated by macroscale measurements as well as by scanning electrochemical cell microscopy (SECCM). The band gaps of Gr and h-BN (0–5.97 eV) encompass the wide range of band gaps for 2D materials, so these interfaces (p-Si/Gr and p-Si/h-BN) serve as useful references to understand the behavior of 2D materials more generally. The value of Voc shifted with respect to the effective potential of the contacting solution, with slopes (ΔV oc /ΔE Eff ) of -0.27 and -0.38 for p-Si/Gr and p-Si/h-BN, respectively, indicating that band bending at the p-Si/h-BN and p-Si/Gr interfaces responds at least partially to changes in the electrochemical potential of the contacting liquid electrolyte. Additionally, SECCM is shown to be an effective method to interrogate the nanoscale photoelectrochemical behavior of an interface, showing little spatial variance over scales exceeding the grain size of the CVD-grown 2D materials in this work. The measurements demonstrated that the polycrystalline nature of the 2D materials had little effect on the results and confirmed that the macroscale measurements reflected the junction behavior at the nanoscale.

2D material↗

Mathematical Modeling of Hydroxide-Exchange-Membrane Water Electrolyzer

Water electrolyzers can transform intermittent renewable energy like solar energy and wind energy into the chemical energy of hydrogen with zero greenhouse-gas emissions. The hydroxide-exchange membrane electrolyzer (HEME) combines the capability to produce pressurized hydrogen with the advantage of being able to use low or non-platinum group metal (PGM) electrocatalysts in the alkaline environment.1 Hydroxide salts, for example, KOH, are added to the HEME water feed on both anode and cathode to improve its performance. However, the specific mechanism of performance improvement still needs to be further understood. In addition, at high current densities, bubble evolution can result in mass-transport limitations, a less well studied phenomena. Mathematical modeling is ideal to explore these issues as it is cost and time efficient and can deconvolute the physics, processes, and observed phenomena and study the applied-voltage breakdown. In this work, we extend our previously developed 1D two-phase continuum model2 to study the varies processes in the HEME and provide insights on performance optimizations. First, the oxygen evolution reaction (OER) and hydrogen evolution reaction (HER) kinetics at different hydroxide concentrations have been studied by rotating disk electrodes (RDE) and implemented in the model. Then, the model is calibrated and validated against experimental HEME polarization curves for different KOH concentrations as a liquid electrolyte. The model clearly shows a performance increase with increasing KOH concentrations, which is consistent with the experimental results. The reduced ohmic resistance and increased electrochemical active surface area (ECSA) are the two main reasons for performance increase. The large amount of hydroxide in the liquid electrolyte not only helps to distribute the reactant hydroxide throughout the catalyst layer (CL), which reduces ohmic loss, but also enables reaction at the interface between the liquid electrolyte and electrocatalyst, which increases the ECSA. Applied-voltage breakdown demonstrates that the electrolyzer performance is dominated by anode kinetics and ohmic loss. A comparison with the DI water feed shows a more uniform current distribution in the anode CL when KOH is added, which indicates a higher utilization of the CL. Second, we present modeling on the effects of bubble coverage. As gas evolves, part of the ECSA is minimized due to bubble coverage. To account for this effect, an empirical relationship between the fractional bubble coverage and the current density is implemented in the model.3 The model shows this bubble coverage effect is more pronounced at large current densities with DI water feed. Acknowledgements This work was funded under the HydroGEN Consortium by the Energy Efficiency and Renewable Energy, Hydrogen and Fuel Cell Technologies Office, of the U. S. Department of Energy under contract number DE-AC02-05CH11231. References R. Abbasi, B. P. Setzler, S. Lin, J. Wang, Y. Zhao, H. Xu, B. Pivovar, B. Tian, X. Chen, G. Wu and Y. Yan, 31, 1805876 (2019). L. N. Stanislaw, M. R. Gerhardt and A. Z. Weber, ECS Transactions, 92, 767 (2019). H. Vogt and R. J. Balzer, Electrochimica Acta, 50, 2073 (2005).

Liu, Jiangjin↗

Miniature Sapphire Acoustic Resonator - MSAR

A room temperature sapphire acoustics resonator incorporated into an oscillator represents a possible opportunity to improve on quartz ultrastable oscillator (USO) performance, which has been a staple for NASA missions since the inception of spaceflight. Where quartz technology is very mature and shows a performance improvement of perhaps 1 dB/decade, these sapphire acoustic resonators when integrated with matured quartz electronics could achieve a frequency stability improvement of 10 dB or more. As quartz oscillators are an essential element of nearly all types of frequency standards and reference systems, the success of MSAR would advance the development of frequency standards and systems for both groundbased and flight-based projects. Current quartz oscillator technology is limited by quartz mechanical Q. With a possible improvement of more than x 10 Q with sapphire acoustic modes, the stability limit of current quartz oscillators may be improved tenfold, to 10(exp -14) at 1 second. The electromagnetic modes of sapphire that were previously developed at JPL require cryogenic temperatures to achieve the high Q levels needed to achieve this stability level. However sapphire fs acoustic modes, which have not been used before in a high-stability oscillator, indicate the required Q values (as high as Q = 10(exp 8)) may be achieved at room temperature in the kHz range. Even though sapphire is not piezoelectric, such a high Q should allow electrostatic excitation of the acoustic modes with a combination of DC and AC voltages across a small sapphire disk (approximately equal to l mm thick). The first evaluations under this task will test predictions of an estimated input impedance of 10 kilohms at Q = 10(exp 8), and explore the Q values that can be realized in a smaller resonator, which has not been previously tested for acoustic modes. This initial Q measurement and excitation demonstration can be viewed similar to a transducer converting electrical energy to mechanical energy and back. Such an electrostatic tweeter type excitation of a mechanical resonator will be tested at 5 MHz. Finite element calculation will be applied to resonator design for the desired resonator frequency and optimum configuration. The experiment consists of the sapphire resonator sandwiched between parallel electrodes. A DC+AC voltage can be applied to generate a force to act on a sapphire resonator. With the frequency of the AC voltage tuned to the sapphire resonator frequency, a resonant condition occurs and the sapphire Q can be measured with a high-frequency impedance analyzer. To achieve high Q values, many experimental factors such as vacuum seal, gas damping effects, charge buildup on the sapphire surface, heat dissipation, sapphire anchoring, and the sapphire mounting configuration will need attention. The effects of these parameters will be calculated and folded into the resonator design. It is envisioned that the initial test configuration would allow for movable electrodes to check gap spacing dependency and verify the input impedance prediction. Quartz oscillators are key components in nearly all ground- and space-based communication, tracking, and radio science applications. They play a key role as local oscillators for atomic frequency standards and serve as flywheel oscillators or to improve phase noise in high performance frequency and timing distribution systems. With ultra-stable performance from one to three seconds, an Earth-orbit or moon-based MSAR can enhance available performance options for spacecraft due to elimination of atmospheric path degradation.

Wang, Rabi T.↗