Search NASA⌕ Search

SEARCH · Search NASA

Results for “resilience evaluation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Best Practices for Renewable Energy Installations in the National Parks

The U.S. Department of Energy (DOE) Federal Energy Management Program (FEMP) and National Park Service (NPS) have partnered to support the development and utilization of renewable energy technology at federal facilities and on federal lands. FEMP provides technical support to NPS on renewable energy projects to identify and generate significant cost savings and efficiency benefits, investigate opportunities to reduce carbon footprint and/or achieve carbon neutrality, and improve resilience to NPS-owned facilities and sites. The purpose of this report is to support NPS staff as they evaluate whether and how to use renewable energy technologies in park operations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Report of the 2026 Workshop on Next-Generation Ecosystems for Scientific Computing: Harnessing Community, Software, and AI for Cross-Disciplinary Team Science

Scientific computing is undergoing rapid transformation as advances in artificial intelligence, heterogeneous computing, automation, and data-intensive research reshape not only computational tools but also the institutions, workforce models, and collaborative practices that support scientific discovery. This report synthesizes insights from the 2026 Workshop on Next-Generation Ecosystems for Scientific Computing, the second in a three-year series focused on strengthening scientific computing ecosystems through socio-technical co-design. Workshop discussions identified four interdependent strategic themes: software ecosystems for AI-enabled scientific discovery; trust, validation, and traceability; human-AI teaming and paradigm shifts; and workforce, pedagogy, and governance. The report translates these themes into eight priorities for community action spanning shared research infrastructure, trust and traceability, user experience, human-AI teaming, workforce development, cross-sector coordination, stewardship and sustainability, and evaluation of scientific value. Together, these priorities outline directions for building scientific computing ecosystems that remain trustworthy, sustainable, innovative, and resilient as AI assumes a growing role in scientific work.

AI↗

Adaptive cold-load pickup considerations in 2-stage microgrid unit commitment for enhancing microgrid resilience

In an extended main grid outage spanning multiple days, load shedding serves as a critical mechanism for islanded microgrids to maintain essential power and energy reserves that are indispensable for fulfilling reliability and resiliency mandates. However, using load shedding for such purposes leads to increasing occurrence of cold load pickup (CLPU) events. Here, this study presents an innovative adaptive CLPU model that introduces a method for determining and incorporating parameters related to CLPU power and energy requirements into a two-stage microgrid unit commitment (MGUC) algorithm. In contrast to the traditional fixed-CLPU-curve approach, this model calculates CLPU duration, power, and energy demands by considering outage durations and ambient temperature variations within the MGUC process. By integrating the adaptive CLPU model into the MGUC problem formulation, it allows for the optimal allocation of energy resources throughout the entire scheduling horizon to fulfill the CLPU requirements when scheduling multiple CLPU events. The performance of the enhanced MGUC algorithm considering CLPU needs is assessed using actual load and photovoltaic (PV) data. Simulation results demonstrate significant improvements in dispatch optimality evaluated by the amount of load served, customer comfort, energy storage operation, and adherence to energy schedules. These enhancements collectively contribute to reliable and resilient microgrid operation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Enhancing Building Resilience: Maintaining Energy Efficiency and Thermal Comfort During Power Outages in Cold Climates

The increasing frequency and intensity of extreme weather events, such as heatwaves and cold snaps, present significant challenges to building energy performance and occupant comfort. Highly correlated with climate events are widespread long duration power interruptions that may affect thousands of buildings and millions of customers. This study evaluates the impact of building energy performance and occupant thermal comfort in medium-sized office buildings in a cold climate region. Using energy models representing pre-1980 and 2019 vintages, simulations were conducted to assess energy performance under typical weather conditions and occupant thermal comfort during power interrupted extreme cold snap and heatwave climate events under both current 2020s and future 2050s weather conditions. The results show a projected 33% increase in cooling energy demand and a 19% reduction in heating energy by 2050. Findings reveal that older buildings are more susceptible to cold discomfort during cold snaps, while modern airtight buildings are more vulnerable to overheating during heatwaves. Various passive energy efficiency measures, such as improved infiltration control, thermal windows, solar-controlled windows, and cool envelopes, were evaluated for their ability to mitigate thermal discomforts. Solar controlled windows and weatherstripping contribute to reducing cold thermal discomfort by 21% during a power-interrupted cold snap. Solar-controlled windows were found to reduce hot thermal discomfort by 34% during a future power-interrupted heatwave. The study highlights the importance of targeted retrofitting strategies to enhance thermal resilience, especially during power outages, to ensure occupant safety and comfort during extreme climate events.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

How different power plant types contribute to electric grid reliability, resilience, and vulnerability: a comparative analytical framework

Abstract This work explores the dependability tradeoffs provided by the most common types of central power plants in the United States. Historically, the electricity sector has lacked consensus on how reliability , resilience , and vulnerability differ and how those metrics change depending on the power plant fleet composition. We propose distinct definitions for these metrics and an analytical framework to evaluate power plant fleet dependability. Using data analysis and literature review, we identify fifteen dependability attributes across which we rank eleven power plant types relative to natural gas combined-cycle (NGCC) plants. We use NGCC as the benchmark because it is common to many locations and is of relatively recent vintage. The framework shows that each power plant type has unique dependability benefits and drawbacks. We provide examples of how researchers may use the framework to evaluate grid dependability qualitatively under different scenarios. We find that assuming all attributes that contribute to grid dependability are equally important and additive, electric grid dependability is best supported when power plant fleets include a mixture of power generation technologies. Then, we discuss scenario characteristics that could alter the prioritization and relationships of attributes. We also find that if current capacity installation trends continue to favor low- and zero-carbon power plants, US power grids may benefit from increased resilience and reduced vulnerability at the cost of decreased reliability. We conclude by recommending methods for adapting the framework and quantifying relationships between attributes in individual scenarios.

Ramirez-Meyers, K. (ORCID:0000000291216952)↗

Energy Infrastructure Futures: A Multiscale Evaluation of Projected Power Plant Siting Across the Western Interconnection

The US Western Interconnection is facing unprecedented challenges in the form of less predictable peak demand, increasingly diverse generating resources, and fast-growing loads due to the onset of artificial intelligence, hyperscale computing, and electrification. Projecting where future generation may be developed is critical to maintaining a robust and resilient electric grid under this mounting uncertainty and variability. Using an integrated multisectoral, multiscale modeling framework that links a human-Earth systems model, an hourly load model, a geospatial power plant siting model, and an hourly grid operations model, we evaluate the power plant landscape evolution under eight alternative futures between 2020 and 2055. These futures represent a wide but plausible range of atmospheric conditions, emissions constraints, and economic, technological, and population growth assumptions. We find that local-level development can vary substantially both by generation type and capacity buildout across these futures. Specific regions of the Western Interconnection are projected to see large amounts of capacity development regardless of the future scenario. We additionally determine that projected power plant locations are more heavily influenced by the cost to interconnect to the electric grid than the locational energy value.

Mongird, Kendall↗

Security Enhancement of Network Constraint Grid-Edge Energy Management System

Network constrained grid edge energy management system (EMS) provides economic solution for active and reactive power dispatch of distributed energy resources (DERs) at the grid edge level. Grid edge EMS ensures secure interconnection of a circuit segment to the distribution system by maintaining grid code requirements (e.g. IEEE 1547–2018). Grid edge EMS is dependent on communication to receive load measurement, which brings a risk of unobservable false data injection attacks (FDIAs). To mitigate the risk, this paper proposes a framework to enhance resilient operation of grid edge EMS by detecting the unobservable FDIAs on loads and replacing them with forecasted values. In this work, a two-step detection algorithm is proposed. In first step, conventional residual based algorithm is deployed. Autoencoder (AE) based data driven mechanism is included in second step to detect the presence of unobservable FDIAs. After ensuring the presence of FDIA, its specific location is detected by checking the maximum residue values till the predefined threshold value is reached. Detected false data injected loads are then replaced with forecasted load values following long-short term memory (LSTM) based forecast to ensure resilient performance of grid edge EMS in the presence of attacks. This proposed security enhancement framework for grid edge EMS is evaluated in IEEE 13 bus system with three integrated DERs. Numerical simulation shows the validation of the proposed framework by reducing voltage violation in real operation of grid edge EMS.

cyber attack detection↗

Resilience of the slow component in timescale separated synchronized oscillators

Physiological networks are usually made of a large number of biological oscillators evolving on a multitude of different timescales. Phase oscillators are particularly useful in the modelling of the synchronization dynamics of such systems. If the coupling is strong enough compared to the heterogeneity of the internal parameters, synchronized states might emerge where phase oscillators start to behave coherently. Here, we focus on the case where synchronized oscillators are divided into a fast and a slow component so that the two subsets evolve on separated timescales. We assess the resilience of the slow component by, first, reducing the dynamics of the fast one using Mori-Zwanzig formalism. Second, we evaluate the variance of the phase deviations when the oscillators in the two components are subject to noise with possibly distinct correlation times. From the general expression for the variance, we consider specific network structures and show how the noise transmission between the fast and slow components is affected. Interestingly, we find that oscillators that are among the most robust when there is only a single timescale, might become the most vulnerable when the system undergoes a timescale separation. We also find that layered networks seem to be insensitive to such timescale separations.

97 MATHEMATICS AND COMPUTING↗

Perennializing marginal croplands: going back to the future to mitigate climate change with resilient biobased feedstocks

Managing annual row crops on marginally productive croplands can be environmentally unsustainable and result in variable economic returns. Incorporating perennial bioenergy feedstocks into marginally productive cropland can engender ecosystem services and enhance climate resiliency while also diversifying farm incomes. We use one of the oldest bioenergy-specific field experiments in North America to evaluate economically and environmentally sustainable management practices for growing perennial grasses on marginal cropland. This long-term field trial called 9804 was established in 1998 in eastern Nebraska and compared the productivity and sustainability of corn (Zea mays L.)—both corn grain and corn stover—and switchgrass (Panicum virgatum L.) bioenergy systems under different harvest strategies and nitrogen (N) fertilizer rates. This experiment demonstrated that switchgrass, compared to corn, is a reliable and sustainable bioenergy feedstock. This experiment has been a catalyst for other bioenergy projects which have also expanded our understanding of growing and managing bioenergy feedstocks on marginal cropland. We (1) synthesize research from this long-term experiment and (2) provide perspective concerning both the knowledge gained from this experiment and knowledge gaps and how to fill them as well as the role switchgrass will play in the future of bioenergy.

09 BIOMASS FUELS↗

Resilience of the slow component in timescale-separated synchronized oscillators

Physiological networks are usually made of a large number of biological oscillators evolving on a multitude of different timescales. Phase oscillators are particularly useful in the modelling of the synchronization dynamics of such systems. If the coupling is strong enough compared to the heterogeneity of the internal parameters, synchronized states might emerge where phase oscillators start to behave coherently. Here, we focus on the case where synchronized oscillators are divided into a fast and a slow component so that the two subsets evolve on separated timescales. We assess the resilience of the slow component by, first, reducing the dynamics of the fast one using Mori-Zwanzig formalism. Second, we evaluate the variance of the phase deviations when the oscillators in the two components are subject to noise with possibly distinct correlation times. From the general expression for the variance, we consider specific network structures and show how the noise transmission between the fast and slow components is affected. Interestingly, we find that oscillators that are among the most robust when there is only a single timescale, might become the most vulnerable when the system undergoes a timescale separation. We also find that layered networks seem to be insensitive to such timescale separations.

59 BASIC BIOLOGICAL SCIENCES↗

Small Nuclear Reactors for Maritime Ports

Maritime ports are entering a period of sharply rising electricity demand as operations are electrified, shore power adoption grows, and energy-intensive industries expand near ports. This report evaluates the feasibility of small nuclear reactors at U.S. ports, which could offer stable baseload power and reduced dependence on regional grids. The report describes the current state of advanced reactor technologies and other factors important for future deployment such as safety and operations, siting requirements, regulatory environments and policy, and other co-benefit considerations. A structured evaluation across a diverse group of U.S. ports highlights the wide variation in feasibility. Fifteen ports were analyzed through port interviews and data collection to assess the port-specific conditions that most impact advanced reactor deployment. The analysis found that the most feasible ports for deployment have favorable geotechnical stability, supportive regulatory environments, and substantial energy loads in a grid-constrained environment. Additionally, an initial reactor size matching was done for the ports based on their reported energy consumption across different modes of operation. However, further analysis and detailed data will be required in the future to determine the optimal reactor-port matching. The economic viability to adopt this technology will be dictated by competitive cost of nuclear-generated electricity compared to other alternatives. Overall, small nuclear reactors present a promising but highly site-dependent pathway for ports seeking resilient, high-capacity energy solutions that support future energy demands. This report identifies key areas for future research and highlights ports that warrant further evaluation to assess the viability of small nuclear reactor implementation. By establishing these priorities, the analysis provides support for the development of informed strategies for potential advanced nuclear technology deployment. The inclusion of ports in this report does not imply their endorsement of nuclear energy generation, and the authors are grateful for the information, expertise, and perspectives they contributed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Testing of Materials and Coatings at up to 1150°C and 300 bar for use in Oxy-Combustion Turbine

Various materials that may be used in a supercritical carbon dioxide (sCO2) oxy-fuel turbine in the 150-300 MWe size range are being evaluated in various environments of interest. The inlet of the turbine must be capable of 1,150 °C at 300 bar and the exhaust temperature is expected to be within the 725-775 °C range. The design requirements are pushing the known limits of high temperature materials. Little is known about the oxidation of the metallic alloys considered for turbine nozzles and blades or about the resilience of thermal management solutions, such as thermal barrier coatings (TBC), required to accommodate these high temperatures. The combinations of high temperature resistant materials and coatings must be tested in sCO2 to evaluate their reliability in an oxy-fuel turbine environment. A total of 13 alloys were chosen to be tested. They included bare samples, with nano deposited MCrAlY bond coat only, or with the addition of a TBC. A unique test facility was developed to expose those materials in sCO2 at up to 300 bar and 1150 °C for up to 5,000 hours. This was accomplished by placing an induction heater inside an autoclave to achieve those high temperature locally while the pressurized vessel is cooled externally. The specimens are weighed before and after exposure to determine the oxidation rate. The integrity, morphology, and composition of some of the coatings and thermally grown oxide will be investigated by scanning electron microscopy (SEM). This paper presents the up-to-date results of the testing coated and uncoated superalloys in sCO2 at up to 1150 °C and up to 300 bar performed at Southwest Research Institute.

Bocher, Florent↗

Defensive Islanding to Enhance the Resilience of Distribution Systems Against Cyber-Induced Failures

The extensive integration of communication, computation, and control technologies into cyber-physical power systems (CPPSs) has increased the vulnerabilities of CPPSs to cyberattacks. This calls for developing solutions that assess and reduce the impacts of cyber-induced failures on CPPSs. This paper proposes a defensive islanding strategy to isolate impacted parts of the CPPS and form self-sufficient islanded grids with an objective of minimum load curtailment. The defensive islanding aims to split a power system into smaller grids to improve its resilience against a potential extreme event. A clustering approach that leverages the hierarchical spectral clustering method is utilized for the optimal defensive islanding. The proposed approach captures the fragility behavior and loading conditions of power system components due to cyber-induced failures. A graphical-based coupling framework is used to map the impacts of cyber failures into operation of power system components. The proposed method is demonstrated on a modified 33-node distribution feeder system integrated with distributed energy resources. The amount of load curtailment and radiality constraints have been used to evaluate the performance of the proposed clustering strategies. The results show the capability of the proposed algorithm to create islands considering the cyber-induced failures for enhanced resilience.

cyber-induced failures↗

A Network-Aware Distributed Energy Resource Aggregation Framework for Flexible, Cost-Optimal, and Resilient Operation

To efficiently use the ubiquitous behind-the-meter distributed energy resources (DERs) in distribution systems for providing grid services, this paper presents a hierarchical control framework for DER optimal aggregation and control. We first develop a convex optimization model to evaluate the DER flexibility, and then use a convex model-predictive-control based approach to dispatch those DERs. The hierarchical control framework consists of a utility controller, community aggregators and multiple home energy management systems. The flexibility of the DERs is evaluated by each controller in the hierarchy such that the resultant flexibility is feasible given its operational domain. Based on the determined flexibility, the hierarchical controllers then compute optimal setpoints for the DERs to help the distribution system regulate node voltages and provide other distribution grid services. Numerical simulations performed on a model of a real distribution feeder in Colorado, using actual DER data in a residential community demonstrate that the proposed approach can effectively alleviate voltage issues and support resilient operation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Smart Data Mapping for Connecting Power System Model and Geospatial Data

Knowing the geospatial locations of power system model elements is the foundation for analyzing system vulnerability to natural hazards and connecting loads with end users and their communities. However, power system models and geospatial data for power grid assets may have been developed asynchronously without close coordination. Creating a direct mapping between the two may be a challenging task, considering heterogeneous data structures, target uses, historical legacies, and human errors. This work aims to build an automatic data mapping workflow to connect power system model elements and geospatial data for transmission network, and to support energy grid resilience studies for Puerto Rico. The primary steps in this workflow include constructing graphs using geospatial data, and aligning them to the transmission networks defined in the power system data. The results have been evaluated against existing manual mapping practices for part of the Puerto Rico Power Grid model to illustrate the performance of such auto-mapping solutions.

Resilience, geospatial data, grid transmission net↗

An iterative learning and inference approach to managing dynamic cyber-vulnerabilities of complex systems

As modern systems become increasingly reliant on cyber-technologies and continue to be integrated with physical systems, managing risks from deliberate and non-deliberate sources is a significant research challenge. Unlike strictly physical systems, cyber-enabled physical systems are influenced by dynamic and evolving technologies, environments, and attack mechanisms. As a result, vulnerabilities are rapidly changing and difficult to detect and manage. While there is recent interest in the dynamic properties of performance through resilience analysis, limited research addresses the dynamic nature of cyber-system vulnerability. This paper presents a dynamic iterative learning approach to evaluate the state of health for systems as related to cyber-vulnerabilities. These time-varying system health characteristics may not be visible, but can be inferred using observable characteristics. The approach recognizes that multiple types of vulnerabilities need to be included in a holistic system health assessment. The methods are applied to the Common Vulnerability Scoring System database containing over 100,000 documented cybersecurity vulnerabilities. This work is the first to acknowledge the dynamic properties of cyber-vulnerability, while also inferring system health using observable data and hidden states of system health. This work will be of interest to managers of large-scale cyber-enabled physical systems who are seeking to prioritize system health investments.

Chatterjee, Samrat↗

Studying impacts of communication system performance on dynamic stability of networked microgrid

The development of smart grid technologies has resulted in increased interdependence between power and communication systems. Many of the operations in the existing power system rely on a stable and secured communication system. For electrically weak systems and time‐critical applications, this reliance can be even greater, where a small degradation in communication performance can degrade system stability. However, despite inter‐dependencies between power and communication systems, only a few studies have investigated the impacts of communication system performance on power system dynamics. This study investigates the dependencies of power system dynamics operations on a communication system performance. First, a detailed, dynamic networked microgrid model is developed in the GridLAB‐D simulation environment, along with a representative multi‐traffic, multi‐channel, multi‐protocol communication system model, developed in the network simulator (ns‐3). Second, a hierarchical engine for large‐scale infrastructure co‐simulation framework is developed to co‐simulate microgrid dynamics, its communication system, and a microgrid control system. The impact of communication system delays on the dynamic stability of networked microgrids is evaluated for the loss of generation using three use‐cases. While the example use‐cases examine microgrid applications and the impact to resiliency, the framework can be applied to all levels of power system operations.

24 POWER TRANSMISSION AND DISTRIBUTION↗