Search NASA⌕ Search

SEARCH · Search NASA

Results for “rooftop”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Low Carbon Technology Strategies: Stand-Alone Retail and Strip Mall

This document includes steps that building owners and operators can implement to achieve smart, healthy, and low-carbon retail buildings within their existing building portfolios. Stand-alone retail and strip malls often use packaged rooftop units for heating, cooling, and ventilation.

analytics↗

Analysis of Automated Fault Detection and Diagnosis Records as an Indicator of HVAC Fault Prevalence: Methodology and Preliminary Results

Faults in commercial buildings can cause energy waste and other performance problems such as reduced occupant comfort, reduced equipment longevity, and increased noise. However, it is currently unknown how commonly faults occur in different equipment types. A method has been developed to estimate the prevalence of faults in air handling units, air terminal units, and rooftop units. This method includes two types of data. The first is data from several automated fault detection and diagnostics (AFDD) software technologies. This type of data provides a large sample that represents a wide range of building types, geographical locations, and equipment types. It includes fault diagnoses from thousands of buildings around the United States, as well as anonymized metadata describing the building and equipment characteristics. The number of fault records is in the order of 107. However, despite the size and richness of the data sample, this data contains some degree of inaccuracy, i.e., false positive and false negative findings. Therefore, the study includes a second type of data, coming from manual inspection of buildings that have had the same AFDD methods applied to them (from the commercial AFDD offerings). Since the field tests are conducted in buildings with AFDD-generated fault prevalence data, they can be combined with the larger sample size to provide insight into the potential biases or lower sensitivity of the AFDD data. Once a library of fault prevalence data is built, it will be studied to provide further insight into the drivers of fault prevalence, for example, whether prevalence is correlated with building type, geographical location (which is tied to climate and to utility rates), building size, etc. This paper describes the methods developed for this study and illustrates them with preliminary data. It discusses some of the challenges of harmonizing disparate outputs from multiple AFDD vendors, application of a unifying fault taxonomy, and fault prevalence metrics.

Ebrahimi Fakhar, Amir↗

Panel-Segmentation: A Python Package for Automated Solar Array Metadata Extraction Using Satellite Imagery

The NREL Python Panel-Segmentation package is a toolkit that automates the process of extracting accurate and valuable metadata related to solar array installations, using publicly available Google Maps satellite imagery. Previously published work includes automated azimuth estimation for individual solar installations in satellite images. Our continued research focuses on automated detection and classification of solar installation mounting configuration (tracking or fixed-tilt; rooftop, ground, or carport). Specifically, a Faster-RCNN Resnet-50 feature pyramid network (FPN) model was trained and validated on 862 manually labeled satellite images. This model was used to perform object detection on satellite imagery, locating and classifying individual solar installations' mounting configuration and type. Model results showed a mean average precision score (mAP) of 77.79%, with the model strongest at detecting fixed-tilt ground mount and fixed-tilt carport installations. The object detection model and its outputs have been incorporated into the Panel-Segmentation package's automated metadata extraction pipeline, which returns the mounting configuration and azimuth for individual solar arrays in satellite imagery. The complete image data set with labels has been released on the U.S. Department of Energy (DOE) DuraMAT DataHub, to encourage further research in this area.

deep learning↗

DISTRIBUTION TRANSFORMER ASSET MONITORING ON THE GRID EDGE USING SMART SENSOR DATA

As new loads such as rooftop photovoltaics, electric vehicles and other distributed energy resources become commonplace on the distribution grid, the stress on already aging assets begins to escalate. This increased loading and changing dynamics can exacerbate failure rates. While traditional monitoring efforts focus on transmission and generation assets, utilities are now beginning to pay close attention to distribution assets in order to increase reliability indices and reduce cost from unexpected outages. This research develops low-cost and scalable methods to monitoring the health of a critical distribution grid asset: the service transformer. Existing methods in literature are either invasive and thus difficult to implement or require the device to be tested offline in an expensive lab setting. Data from the ubiquitous smart meter as well as a novel Bluetooth based transformer monitor are leveraged to automatically notify the utility of deteriorating or damaged transformers. Voltage, temperature, and vibration are some of the signals measured and analyzed by the proposed algorithms to predict transformer failures. Furthermore, these algorithms are designed to keep the implementation and processing costs low by taking advantage of edge computing where possible.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modeling and Experiments on a Dedicated Outdoor Air System Using Liquid Desiccant Heat and Mass Exchangers

Liquid desiccants can provide efficient dehumidification but have yet to see widespread adoption. Most systems studied previously use natural gas-combustion to heat and regenerate the desiccant, and a central chiller plant or cooling tower for removing the heat of absorption. Here we present modeling and experimental results on a novel packaged air conditioner integrating liquid-desiccant heat and mass exchangers with a vapor compression cycle. The packaged system does not need cold or hot water from a central plant or cooling tower and is suitable for rooftop unit air conditioners. The system uses the evaporator to cool the liquid desiccant that is absorbing moisture from the air, and the condenser to heat the liquid desiccant to regenerate it. Efficiency is improved by reducing the load on the evaporator for a given supply-air dewpoint. This paper presents the measured dehumidification efficiency for a 10- ton packaged air conditioner, focusing on dehumidifying ventilation air. The paper also presents a numerical model to predict the outlet conditions and dehumidification efficiency, which we compare with the measured data.

air conditioning↗

A multi-level load shape clustering and disaggregation approach to characterize patterns of energy consumption behavior

This study presents representative electrical load shapes, disaggregated to the end-use level, for over 5000 customer clusters across California’s residential, commercial, industrial and agricultural sectors. We developed a novel, multi-level load shape clustering approach for residential and commercial sectors leveraging interval meter data for over 350,000 California utility customers collected as a part of the Phase 4 California Demand Response (DR) Potential Study. The clustering approach allowed us to identify typical consumption patterns and categorize customers based on their daily load shape displayed throughout the year. For example, we were able to identify customers with particular energy technologies such as electric vehicles and rooftop solar, as well as building occupancy types such as restaurants, grocery stores and even unoccupied buildings, based solely on whole-building interval data. We then combined the load shape-based clusters with other customer information including building type, climate, geographical area, total consumption and low-income status, to create a set of customer clusters based on both demographics and usage patterns. Total cluster electricity demand was then disaggregated into a wide variety of end-uses using weather normalization and other publicly available end-use load shape datasets. The resulting disaggregated cluster load shapes will be released in anonymized form as part of the Phase 4 DR Potential Study. They will have wide-ranging applications in energy research and policy analysis, including estimation of energy efficiency (EE) and DR potential on the end-use level, time-dependent valuation of EE savings, building stock modeling, and developing customer targeting strategies for EE and DR programs.

Murthy, Samanvitha↗

MS4 - Municipal Separate Storm Sewer System

Stormwater refers to the rainwater or melted snow that flows over land surfaces - including streets, rooftops, and parking lots - that does not infiltrate into the ground. It is collected by storm drains and conveyed through a network of pipes and channels, eventually discharging into streams, rivers, lakes, or oceans. The storm sewer systems on NREL's South Table Mountain (STM) campus, distinct from the sanitary sewer systems, is known as a Municipal Separate Storm Sewer System (MS4).The Environmental Protection Agency (EPA) issued NREL an MS4 Permit for the STM campus to regulate stormwater operations within the boundaries of the STM campus. The STM campus is the only NREL campus to have an MS4 Permit.

ENERGY PLANNING, POLICY, AND ECONOMY↗

Achieving Scale: Community Solar Technical Potential and Meaningful Benefits in the United States

The slide deck was presented at the webinar on February 28th titled Achieving Scale: Community Technical Potential and Meaningful Benefits in the United States. It describes the National Community Solar Partnership program followed by methodology and results from a study on the technical potential of community solar and associated meaningful benefits. A key finding of the study suggests that the opportunity space for community solar to meet unmet demand for solar energy is not primarily constrained by technical potential, but by technological, market, and policy factors. NREL used rooftop and ground-mount photovoltaic siting data to model annual energy production from community solar based on various constraints and system performance. Given modeled results and community solar deployment, we discuss potential benefits including household savings, low-to-moderate income household access to solar, resilience and grid benefits, community ownership, workforce development and entrepreneurship as well as insights into community solar siting opportunities.

community solar↗

Assessing the Impact of Variable Air Volume Box Damper Stuck Faults Using a Building Automation System and Building Energy Simulation Model

The study examines the impact of variable air volume (VAV) damper stuck faults on the system operation, building indoor conditions, and reheating energy consumption. This study includes both experimental and simulation studies for five test scenarios, including a fault-free scenario. We implemented VAV damper stuck fault through the building automation system (BAS). Results show that a damper stuck in a high opening position (60% damper opening) results in supplying an excessive amount of cold air from the rooftop unit (RTU) to the conditioned zone, increasing reheating energy consumption. The results of this research can serve as a foundational resource for developing fault detection algorithms.

Jung, Sungkyun↗

Agrivoltaic Racking Design Optimization Based on Wind and Snow Loading Finite Element Analysis

The racking structure of photovoltaic (PV) systems plays a critical role in ensuring the PV panels generate power properly as it provides integral structural support and sometimes even solar tracking ability. Distinct applications of PV systems require variations of racking structure designs, which yield different mechanical performances under external loading conditions from the environment, such as heavy wind and snow. Past works, such as Reddy et al. [1], have analyzed the pressure effects of wind and snow loading on the racking structure of conventional rooftop and utility PV systems, but there is little knowledge of how various agrivoltaic racking systems perform, in terms of stress and strain, under the same loading conditions. There is also a knowledge gap in the industry on a set of optimized agrivoltaic racking design standards. This study investigates the mechanical performance of various existing racking systems and proposes novel designs that are optimized for agrivoltaics applications under wind and snow loading.

Liao, Quanhuan↗

Dynamic Simulation Modeling and Control of a Desiccant Assisted Direct-expansion Air Handling Unit

Desirable built environments demand simultaneous regulation of thermal comfort and indoor air quality (IAQ) with energy-efficient operation of heating, ventilation and air conditioning (HV AC) systems, which involves controls of temperature, humidity and airborne contaminants simultaneously. This paper presents the efforts of dynamic modeling and initial development control strategy for a desiccant-assisted multi-functional air handling unit (AHU) coupled with a direct-expansion rooftop unit (RTU) system, which aims to achieve multiple functions for indoor environment conditioning with energy efficient control. The RTU-AHU system includes a desiccant wheel for dehumidification and a conceptual direct air capture (DAC) filtering device for CO2 regulation. A Modelica-based dynamic model is developed for this conceptual system, and a simple decentralized control strategy is designed, which combines a differential-enthalpy based AHU return-air ratio control, a demand-controlled ventilation, and supply-air temperature humidity control via the RTU and DW controls. The proposed control method is evaluated with the Modelica simulation model for a selected set of scenarios

Pan, Chao↗

Building the Business Case with JUSTIFI: Quantifying Multiple Benefits in the Automotive Industry

The Michigan State University Industrial Training and Assessment Center (MSU ITAC) conducted a pilot study at an automotive parts manufacturer in Michigan. The study identified energy-productivity enhancements through the application of the JUSTIFI software. Key recommendations included replacing six inefficient rooftop units (RTUs) with a new air rotational unit. By quantifying operational savings for this project, the expected payback period went from 6.6 years to 1.4 years. Additionally, the installation of variable frequency drives (VFDs) on condenser tower motors was suggested. By including all operational benefits, the payback period was reduced from 8.2 years to 1.3 years. This comprehensive analysis aims to bolster the manufacturer's goals of reducing energy while enhancing overall operational efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Increasing the Reach of Low-Income Energy Programmes through Behaviourally Informed Peer Referral

Subsidized energy assistance programmes are a popular policy tool for promoting energy justice, but, like other social benefits programmes, are often undersubscribed. To improve uptake, some programmes have turned to social influence strategies, such as asking programme participants to refer their peers. Here, through a field experiment with California's low-income solar programme (N = 7,676), we show that referral behaviour depends on how existing participants are approached. Adding behavioural science strategies to a referral reward increases peer referral rates, referral quality and ultimately solar adoption. Compared with only reminding existing adopters of a potential US$200 reward for referrals that result in adoption, adding an appeal to reciprocity through a non-contingent US$1 gift - and further combining this gift with a simplified referral process - leads to 2.6-5.2 times as many solar contracts. These results highlight the potential of behaviourally informed peer referral programmes to accelerate equitable access to clean energy.

California↗

Tribal Renewable Energy: Bishop Paiute Tribe, Residential Solar Program Phase II (Final Report)

The project consisted of the design, installation, inspection, and interconnection of 35 grid-tied, solar electric systems, totaled 123 kW rated capacity, on qualified existing low-income single-family homes located within the Bishop Paiute Reservation, which provide at least 65-79% savings in displaced electricity. Tribal job trainees were hired for each installation, gaining valuable job experience. Additionally, each homeowner was educated on energy efficiency and renewable energy. The overall project goal was to deploy clean energy systems in order to achieve the Bishop Paiute Tribe’s long-term goals of energy self-sufficiency, environmental protection, and better lives for our Tribal members and community. The energy displaced was 82.4 percent of total electricity used (exceeding estimated 65-79%)or over 170,000 kWh/year generating approximately $1.29 million worth of power for low-income families over their lifespans, while eliminating an estimated 2,640 tons of greenhouse gas emissions. This reduction makes a significant difference on the reservation giving more families money to spend on other essential items, while reducing their carbon footprint in this beautiful mountain community. Also, implementing these 35 systems provided a approximately 132 hours of paid solar installation work for tribal members. Training and good paying jobs are scarce on the reservation and solar is the fastest growing industry in CA and this training offered our members a real chance to learn and then get paid. The program is very significant to the family who qualified, as most families fall below the federal poverty guidelines, and many are living paycheck to paycheck. Overall, the triple impact of the Bishop Paiute Tribe Residential Solar Program Phase II— affordable energy for low-income families, on-site clean energy production, and hands-on solar installation jobs for local workers—these all help build the Tribe’s energy, economic, environmental, and social self-sufficiency and sovereignty amongst the most needy on the Reservation

14 SOLAR ENERGY↗

Tribal Renewable Energy: Bishop Paiute Tribe Youth Solar Job Training Development (Final Report)

This Project provided workshops and hands on opportunities for young tribal adults to gain education,training,and employment in the solar industry; including 1 youth to meet the eligibility requirements for the NABCEP Solar Installer Exam. 10 tribal youth, ages 16-24, attended workshops focused on learning solar fundamentals and then applied those learned skills to hands on training, installing solar on 2 tribal homes. GRID provided certificates authenticating their volunteer hours and skills learned. This program of youth training really excited the tribal leadership as well as the tribal youth. This opportunity was in alignment with the tribe’s Strategic Energy Plan, and supported tribal self-sufficiency, a path to economic development and for the youth it also represented the environmental stewardship the tribe believes in.

14 SOLAR ENERGY↗