Search NASA⌕ Search

SEARCH · Search NASA

Results for “sample acquisitions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

A survey of the state-of-the-art and focused research in range systems, task 1

This final report presents the latest research activity in voice compression. We have designed a non-real time simulation system that is implemented around the IBM-PC where the IBM-PC is used as a speech work station for data acquisition and analysis of voice samples. A real-time implementation is also proposed. This real-time Voice Compression Board (VCB) is built around the Texas Instruments TMS-3220. The voice compression algorithm investigated here was described in an earlier report titled, Low Cost Voice Compression for Mobile Digital Radios, by the author. We will assume the reader is familiar with the voice compression algorithm discussed in this report. The VCB compresses speech waveforms at data rates ranging from 4.8 K bps to 16 K bps. This board interfaces to the IBM-PC 8-bit bus, and plugs into a single expansion slot on the mother board.

Omura, J. K.↗

Combined optimization of image-gathering and image-processing systems for scene feature detection

The relationship between the image gathering and image processing systems for minimum mean squared error estimation of scene characteristics is investigated. A stochastic optimization problem is formulated where the objective is to determine a spatial characteristic of the scene rather than a feature of the already blurred, sampled and noisy image data. An analytical solution for the optimal characteristic image processor is developed. The Wiener filter for the sampled image case is obtained as a special case, where the desired characteristic is scene restoration. Optimal edge detection is investigated using the Laplacian operator x G as the desired characteristic, where G is a two dimensional Gaussian distribution function. It is shown that the optimal edge detector compensates for the blurring introduced by the image gathering optics, and notably, that it is not circularly symmetric. The lack of circular symmetry is largely due to the geometric effects of the sampling lattice used in image acquisition. The optimal image gathering optical transfer function is also investigated and the results of a sensitivity analysis are shown.

Halyo, Nesim↗

Combined optimization of image-gathering optics and image-processing algorithm for edge detection

This paper investigates the relationships between the image-gathering and image-processing systems for minimum mean-squared error estimation of scene characteristics. A stochastic optimization problem is formulated in which the objective is to determine a spatial characteristic of the scene rather than a feature of the already blurred, sampled, and noisy image data. The Wiener filter for the sampled image case is obtained as a special case, where the desired characteristics is scene restoration. Optimal edge detection is investigated. It is shown that the optimal edge detector compensates for the blurring introduced by the image-gathering optics, and, notably, that it is not circularly symmetric. The lack of circular symmetry is largely due to the geometric effects of the sampling lattice used in image acquisition.

Halyo, N.↗

Quasi-Uniform High Speed Foam Crush Testing Using a Guided Drop Mass Impact

A relatively simple method for measuring the dynamic crush response of foam materials at various loading rates is described. The method utilizes a drop mass impact configuration with mass and impact velocity selected such that the crush speed remains approximately uniform during the entire sample crushing event. Instrumentation, data acquisition, and data processing techniques are presented, and limitations of the test method are discussed. The objective of the test method is to produce input data for dynamic finite element modeling involving crash and energy absorption characteristics of foam materials.

Jones, Lisa E.↗

Real-Time Data Display

RT-Display is a MATLAB-based data acquisition environment designed to use a variety of commercial off-the-shelf (COTS) hardware to digitize analog signals to a standard data format usable by other post-acquisition data analysis tools. This software presents the acquired data in real time using a variety of signal-processing algorithms. The acquired data is stored in a standard Operator Interactive Signal Processing Software (OISPS) data-formatted file. RT-Display is primarily configured to use the Agilent VXI (or equivalent) data acquisition boards used in such systems as MIDDAS (Multi-channel Integrated Dynamic Data Acquisition System). The software is generalized and deployable in almost any testing environment, without limitations or proprietary configuration for a specific test program or project. With the Agilent hardware configured and in place, users can start the program and, in one step, immediately begin digitizing multiple channels of data. Once the acquisition is completed, data is converted into a common binary format that also can be translated to specific formats used by external analysis software, such as OISPS and PC-Signal (product of AI Signal Research Inc.). RT-Display at the time of this reporting was certified on Agilent hardware capable of acquisition up to 196,608 samples per second. Data signals are presented to the user on-screen simultaneously for 16 channels. Each channel can be viewed individually, with a maximum capability of 160 signal channels (depending on hardware configuration). Current signal presentations include: time data, fast Fourier transforms (FFT), and power spectral density plots (PSD). Additional processing algorithms can be easily incorporated into this environment.

Pedings, Marc↗

More Efficient Precipitation Rate Data Acquisition with the STORM Swath-Based Analysis Tool

A multitude of locations exist for acquiring satellite-derived precipitation rate data. Because the volume of data exceeds what can reasonably be analyzed manually, online tools have been developed to help researchers make more informed data acquisition decisions. Some interfaces provide sample images generated from prioritized variables to enable efficient visual inspection, while others include the ability to subset geographically to reduce the volume of the data to the area of interest. Building upon such value-added services is the STORM (the NASA Precipitation Processing System (PPS) data product ordering system) Swath-Based Analysis Tool (https://storm.pps.eosdis.nasa.gov/storm/Analysis.jsp). With it, users can compare overflights of multiple precipitation satellites simultaneously and from this make determinations about which swaths will best serve their research. They can preview these overflights with two distinct visualization tools. Finally, they can then download geographically subset swaths that have precipitation rate characteristics matching their research needs. A user starts by making up to six selections. They then select their date range of interest going back to 1997. Finally, they select a geographical region either by inputting latitude-longitude corners of a rectangle or drawing that rectangle on an interactive map. The system processes each file, determining aggregate statistics about the precipitation rates within the selected region as observed by each instrument. These statistical values are added to a time series graph as a "time remaining" counter is continuously updated. The chart is fully interactive, with detailed values displayed upon mouseover, and numerous options available upon clicking each point. Since the user is likely to need the relevant files for their own research, they can generate an order from their request. All files are geographically subset to the region of interest, and the user can use the statistical values to limit which files are added to the order. This flexibility helps to ensure researchers are only downloading the files they need for their work, making for a more efficient process both from a time-consumption and a storage perspective. This paper will introduce the Swath-Based Analysis Tool and explore its numerous features. It will discuss several use cases for precipitation scientists.

remote sensing↗

Simple, Compact, High-Resolution Monochromatic X-Ray Source for Characterization of X-Ray Calorimeter Arrays

X-ray calorimeters routinely achieve very high spectral resolution, typically a few eV full width at half maximum (FWHM). Measurements of calorimeter line shapes are usually dominated by the natural linewidth of most laboratory calibration sources. This compounds the data acquisition time necessary to statistically sample the instrumental line broadening and can add systematic uncertainty if the intrinsic line shape of the source is not well known. To address these issues, we have built a simple, compact monochromatic x-ray source using channel cut crystals. A commercial x-ray tube illuminates a pair of channel cut crystals that are aligned in a dispersive configuration to select the Kα1 line of the x-ray tube anode material. The entire device, including the x-ray tube, can be easily hand-carried by one person and may be positioned manually or using a mechanical translation stage. The output monochromatic beam provides a collimated image of the anode spot with magnification of unity in the dispersion direction (typically 100 μm–200 μm for the x-ray tubes used here) and is unfocused in the cross-dispersion direction so that the source image in the detector plane appears as a line. We measured output count rates as high as 10 count/s/pixel for the Hitomi soft x-ray spectrometer, which had 819 μm square pixels. We implemented different monochromator designs for energies of 5.4 keV (one design) and 8.0 keV (two designs), which have effective theoretical FWHM energy resolution of 0.125 eV, 0.197 eV, and 0.086 eV, respectively; these are well-suited for optimal calibration measurements of state-of-the art x-ray calorimeters. We measured an upper limit for the energy resolution of our Cr Kα1 monochromator of 0.7 eV FWHM at 5.4 keV, consistent with the theoretical prediction of 0.125 eV.

M A Leutenegger↗

Electronic Nose Development and Preliminary Human Breath Testing for Rapid, Non-Invasive COVID-19 Detection

We adapted an existing, spaceflight-proven, robust “electronic nose” (E-Nose) that uses an array of electrical resistivity-based nanosensors mimicking aspects of mammalian olfaction to conduct on-site, rapid screening for COVID-19 infection by measuring the pattern of sensor responses to volatile organic compounds (VOCs) in exhaled human breath. We built and tested multiple copies of a hand-held prototype E-Nose sensor system, composed of 64 chemically sensitive nanomaterial sensing elements tailored to COVID-19 VOC detection; data acquisition electronics; a smart tablet with software (App) for sensor control, data acquisition and display; and a sampling fixture to capture exhaled breath samples and deliver them to the sensor array inside the E-Nose. The sensing elements detect the combination of VOCs typical in breath at parts-per-billion (ppb) levels, with repeatability of 0.02% and reproducibility of 1.2%; the measurement electronics in the E-Nose provide measurement accuracy and signal-to-noise ratios comparable to benchtop instrumentation. Preliminary clinical testing at Stanford Medicine with 63 participants, their COVID-19-positive or COVID-19-negative status determined by concomitant RT-PCR, discriminated between these two categories of human breath with a 79% correct identification rate using “leave-one-out” training-and-analysis methods. Analyzing the E-Nose response in conjunction with body temperature and other non-invasive symptom screening using advanced machine learning methods, with a much larger database of responses from a wider swath of the population, is expected to provide more accurate on-the-spot answers. Additional clinical testing, design refinement, and a mass manufacturing approach are the main steps toward deploying this technology to rapidly screen for active infection in clinics and hospitals, public and commercial venues, or at home.

COVID-19↗

Oceanographic biooptical profiling system

A new oceanographic instrument to measure underwater optical, biological, and physical properties has been designed, built, and used extensively at sea. The new instrument system is a significant advance that permits optimum sampling strategies using ship, aircraft, and satellite optical sensors for ocean research. The design criteria for the biooptical profiling system included the rapid acquisition of data to accommodate shipboard synoptic sampling; the measurement of the necessary parameters for providing appropriate contemporaneous surface data for remote sensors; the compatibility of the data acquisition system with conventional conductivity temperature depth-type cables and winches on the oceanographic fleet; the capability of real-time display of data along with rapid preliminary data reduction at sea. The primary instrument package in this profiling system is a new microprocessor controlled multiwavelength spectroradiometer. A description of the instrument and examples of data are presented.

Smith, R. C.↗

Curating Nasa's Future Extraterrestrial Sample Collections: the Role of Advanced Curation

The Astromaterials Acquisition and Curation Office at NASA Johnson Space Center (JSC) (henceforth referred to herein as NASA Curation Office) is responsible for curating all of NASA's extraterrestrial samples. Under the governing document, NASA Policy Directive (NPD) 7100.10F "Curation of Extraterrestrial Materials," JSC is charged with "The curation of all extraterrestrial material under NASA control, including future NASA missions." The Directive goes on to define Curation as including "...documentation, preservation, preparation, and distribution of samples for re-search, education, and public outreach." Here we describe some of the ongoing efforts to ensure that the future activities of the NASA Curation Office are working towards a state of maximum proficiency.

McCubbin, Francis M.↗

H I 21 centimeter observations and I-band CCD surface photometry of spiral galaxies behind the Virgo Cluster and toward its antipode

Sample selection, radio and optical data acquisition and reduction, and observation results are presented for spiral galaxies behind the Virgo Cluster and toward its antipode. I-band CCD photometry was obtained for all the bright galaxies and part of the sample of faint galaxies in the two local volumes was studied. The statistical properties of the galaxy samples are discussed.

Lu, N. Y.↗

Model-based frequency response characterization of a digital-image analysis system for epifluorescence microscopy

Consideration is given to a model-based method for estimating the spatial frequency response of a digital-imaging system (e.g., a CCD camera) that is modeled as a linear, shift-invariant image acquisition subsystem that is cascaded with a linear, shift-variant sampling subsystem. The method characterizes the 2D frequency response of the image acquisition subsystem to beyond the Nyquist frequency by accounting explicitly for insufficient sampling and the sample-scene phase. Results for simulated systems and a real CCD-based epifluorescence microscopy system are presented to demonstrate the accuracy of the method.

Hazra, Rajeeb↗

ATS-6 - Preliminary results from the 13/18-GHz COMSAT Propagation Experiment

The 13/18-GHz COMSAT Propagation Experiment (CPE) is reviewed, the data acquisition and processing are discussed, and samples of preliminary results are presented. The need for measurements of both hydrometeor-induced attenuation statistics and diversity effectiveness is brought out. The facilitation of the experiment - CPE dual frequency and diversity site location, the CPE ground transmit terminals, the CPE transponder on Applications Technology Satellite-6 (ATS-6), and the CPE receive and data acquisition system - is briefly examined. The on-line preprocessing of the received signal is reviewed, followed by a discussion of the off-line processing of this database to remove signal fluctuations not due to hydrometeors. Finally, samples of the results of first-level analysis of the resultant data for the 18-GHz diversity site near Boston, Mass., and for the dual frequency 13/18-GHz site near Detroit, Mich., are presented and discussed.

Hyde, G.↗

Astromaterial Curation and Research at NASA

Astromaterial sample return missions from other planetary bodies (e.g., the Moon, asteroids, the Sun) and astromaterial sample collection missions here on Earth (e.g., Antarctic Meteorites, Cosmic Dust) have been a vital part of NASA’s science vision since nearly its inception. Beginning with the Apollo missions to the Moon and extending to the recent successful sample collection by the OSIRIS-REx asteroid sample return mission, these astromaterials collections have been an invaluable resource to scientists and educators around the world. Sample studies continue to provide fundamental insight into how our solar system and its constituent bodies formed and evolved over the past 4.5 billion years. As evidence of their broad impact, there are over 19,141 samples on loan to 433 Principal Investigators in 24 countries [1]. As we plan for exploration missions through 2050, sample return missions will continue to play a vital role in NASA’s science vision. Returned samples truly are the gift that keeps on giving. Having the samples accessible on Earth allows new generations of scientists and new generations of instrumentation to pursue ever evolving scientific questions. For example, the Apollo samples were collected ~50 years ago, yet our views of how the Earth-Moon system formed, the role of volatiles in the early inner solar system, and even the positions of the gas giants in the outer solar system have changed dramatically as a result of Apollo sample analyses conducted very recently. Vital to the long-term viability of any sample return mission is the careful curation of the samples. Curatorial efforts need to begin early in the project lifecycle, not with the return of the samples, but at mission conception. The Astromaterials Acquisition and Curation Office at NASA Johnson Space Center is responsible for curating all of NASA’s current and future extraterrestrial samples. Looking at possible sample return missions over the next 35+ years [2], many samples would require curation efforts a step beyond current capabilities, e.g., cold or cryogenic curation, organically and biologically clean curation, curation of gases and ices, and curation of samples with extreme pressure, temperature, or redox requirements. During the lecture, we discuss the current curatorial efforts in JSC curation, as well as discoveries from the astromaterial research. [1] Zeigler, R. A. et al. (2017) Planetary Science Vision 2050 Workshop. [2] McCubbin F. M. et al. (2017) Planetary Science Vision 2050 Workshop.

astromaterial↗

Sub-Nyquist Distortions in Sampled One- and Two-Dimensional Signals Studied

Hardware testing frequently involves the acquisition of waveform and instrumentation signals, which are often recorded on waveform recorders, oscillographs, and video recorders. Years ago, the waveforms were viewed as analog records, as drawn by a paper strip chart pen or electron beam on a cathode ray tube screen. One of the problems in the past was that the analog electronics may not have been able to accurately display the full amplitude of a signal if the real-time signals exceeded the frequency response bandwidth of the recording device. The advent of digital oscilloscopes, waveform recorders, and video frame-grabbers solved many of the frequency response problems, though not all. A restriction on digital waveform acquisition is well known by people in the instrumentation field. Put simply, the sampling frequency must be at least twice the frequency of any signal to be sampled, or vice versa; the signals must be filtered so that none of the signal frequencies are higher than one-half the sample rate (the Nyquist Limit). Then, per Shannon's Sampling Theorem (1949, ref. 1), any sampled signal can be reconstructed for viewing on a display device. If any signals exceed the Nyquist frequency limit, error signals called aliases occur in the output display.

Williams, Glenn L.↗

Is a Linear or a Walkabout Protocol More Efficient When Using a Rover to Choose Biologically Relevant Samples in a Small Region of Interest?

We conducted a field test at a potential Mars analog site to provide insight into planning for future robotic missions such as Mars 2020, where science operations must facilitate efficient choice of biologically relevant sampling locations. We compared two data acquisition and decision-making protocols currently used by Mars Science Laboratory: (1) a linear approach, where sites are examined as they are encountered and (2) a walkabout approach, in which the field site is first examined with remote rover instruments to gain an understanding of regional context followed by deployment of time- and power-intensive contact and sampling instruments on a smaller subset of locations. The walkabout method was advantageous in terms of both the time required to execute and a greater confidence in results and interpretations, leading to enhanced ability to tailor follow-on observations to better address key science and sampling goals. This advantage is directly linked to the walkabout method's ability to provide broad geological context earlier in the science analysis process. For Mars 2020, and specifically for small regions to be explored (e.g., <1 sq. km), we recommend that the walkabout approach be considered where possible, to provide early context and time for the science team to develop a coherent suite of hypotheses and robust ways to test them.

R. Aileen Yingst↗

Elevated temperature viscous remanent magnetization of natural and synthetic multidomain magnetite

The time-temperature relationship of magnetization is a subject of much interest and debate by paleomagnetists, rock magnetists, and magnetic anomaly modellers. We have investigated this relationship by studying the viscous remanent magnetization (VRM) of coarse-grained multidomain (MD) magnetite. Our experiments covered the temperature range from 22 to 400 C, times from minutes to months, and included both Australian granulite samples and multidomain magnetite samples synthesized by the glass ceramic method. VRM acquisition was found to generally increase with temperature but not always at the rate predicted from classical thermal fluctuation theories. Thermal cycling between room temperature (at which the measurements were made) and the VRM acquisition temperature sharply decreased the temperature dependence of the VRM. Room temperature VRM acquisition accelerates with time when plotted on a semilog plot, whereas at elevated temperature the curves are quasilinear against log(time) for both the natural and synthetic samples. This change in behavior may suggest a variation in the VRM acquisition mechanism as a function of temperature for MD magnetite. The granulites have a nearly linear increase in VRM acquisition rate with temperature whereas the glass ceramics display little change in the acquisition rate between 22 and 200 C, but increase by nearly a factor of 3 by 400 C. The increase in VRM of the glass ceramics between 200 and 400 C is in general qualitative agreement with thermal fluctuation theory. There was no systematic change in the rate of VRM acquisition with grain size for the multidomain magnetites used in this study. Elevated temperature (e.g., 400 C) VRM acquisition by the deep crustal granulites, if extrapolated over the Brunhes chron, would produce a magnetization of several A/m which, if true, is of the order required by models for the source of long-wavelength magnetic anomalies.

Kelso, Paul R.↗

Rayleigh Scattering Diagnostic for Measurement of Velocity and Density Fluctuation Spectra

A new molecular Rayleigh scattering based flow diagnostic is used for the first time to measure the power spectrum of gas density and radial velocity component in the plumes of high speed jets. The technique is based on analyzing the Rayleigh scattered light with a Fabry-Perot interferometer used in the static, imaging mode. The PC based data acquisition system is capable of simultaneous sampling of velocity and density at rates to 100 kHz and data record lengths to 10 million. Velocity and density power spectra and velocity-density cross spectra are presented for a subsonic jet, an underexpanded screeching jet, and for Mach 1.4 and Mach 1.8 supersonic jets. Software and hardware interfaces were developed to allow computer control of all aspects of the experiment and data acquisition.

Seasholtz, Richard G.↗