Search NASA⌕ Search

SEARCH · Search NASA

Results for “sampling methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Mars Sample Return orbital rendezvous detection methods

Navigation trades while in pursuit of a rendezvous with a sample capsule in orbit around Mars are described. The rendezvous operation is described in terms of far-field and near-field detection. Passive optical detection is compared with active capsule detection using a radio beacon. Passive methods are, to first order, unconstrained by time while a radio beacon link is time-limited. A possible activity to make use of orbiter plume interactions is explored.

Gustafson, Eric D.↗

A simple and practical wax-encapsulation method for air-sensitive XAS samples

To facilitate X-ray absorption spectroscopy (XAS) measurements of air-sensitive samples, we present a simple method in which materials are encased in common paraffin wax to protect them from air and moisture. We demonstrate the efficacy of this approach using a highly reducing, air- and moisture-sensitive uranium(III) complex, the tris(amide) U[N(SiMe 3 ) 2 ] 3 (1). When finely dispersed in a boron nitride matrix and subsequently encased in inert paraffin wax, samples of 1 remain stable with no visible or spectroscopic degradation after several days under ambient conditions. The viability of this method for XAS measurements was further evaluated across a series of uranium compounds, ranging from uranyl species to highly air- and moisture-sensitive molecular complexes, at the uranium L 3 -edge. Edge energy determinations were highly reproducible (±0.1 eV between replicates) and, where available, showed excellent agreement with literature values. In conclusion, this low-cost, effective, and versatile method offers a viable solution for XAS studies of air-sensitive compounds and materials.

36 MATERIALS SCIENCE↗

Apollo 16 special samples, part B

Information is presented concerning special samples which were collected for specific investigations. The methods of sample collection are described along with fillet and core samples.

Hoerz, F.↗

Numerical Methods for Classical Sampled-System Analysis

SAMSAN provides control-system analyst with self-consistent computer algorithms that support large-order control-system design and evaluation studies. Emphasizes sampled-system analysis. SAMSAN reduces burden on analyst by providing set of algorithms well tested and documented and readily integrated for solving control-system problems.

Frisch, H. P.↗

Monte Carlo Simulations of Crystal Defects in Open Ensembles

Zero- and two-dimensional crystal defects form in open statistical ensembles, such as the grand canonical, that are usually inaccessible with conventional simulation techniques. This longstanding challenge is overcome with a new Hamiltonian Monte Carlo method that samples energy-biased gradual transformations. In conclusion, the method enables free energy calculations for nonideal point defects and the direct prediction of finite-temperature interface structures.

Grain boundaries↗

Method of detecting and counting bacteria in body fluids

A novel method is reported for determining bacterial levels in urine samples, which method depends on the quantitative determination of bacterial adenosine triphosphate (ATP) in the presence of non-bacterial ATP. After the removal of non-bacterial ATP, the bacterial ATP is released by cell rupture and is measured by an enzymatic bioluminescent assay using an enzyme obtained from the firefly.

Chappelle, E. W.↗

Chemical analyses of provided samples

A batch of four samples were received and chemical analysis was performed of the surface and near surface regions of the samples by the surface analysis by laser ionization (SALI) method. The samples included four one-inch diameter optics labeled windows no. PR14 and PR17 and MgF2 mirrors 9-93 PPPC exp. and control DMES 26-92. The analyses emphasized surface contamination or modification. In these studies, pulsed desorption by 355 nm laser light and single-photon ionization (SPI) above the sample by coherent 118 nm radiation (at approximately 5 x 10(exp 5) W/cm(sup 2)) were used, emphasizing organic analysis. For the two windows with an apparent yellowish contaminant film, higher desorption laser power was needed to provide substantial signals, indicating a less volatile contamination than for the two mirrors. Window PR14 and the 9-93 mirror showed more hydrocarbon components than the other two samples. The mass spectra, which show considerable complexity, are discussed in terms of various potential chemical assignments.

Becker, Christopher H.↗

Chemical analyses of provided samples

Two batches of samples were received and chemical analysis was performed of the surface and near surface regions of the samples by the surface analysis by laser ionization (SALI) method. The samples included four one-inch optics and several paint samples. The analyses emphasized surface contamination or modification. In these studies, pulsed sputtering by 7 keV Ar+ and primarily single-photon ionization (SPI) by coherent 118 nm radiation (at approximately 5 x 10(exp 5) W/cm(sup 2) were used. For two of the samples, also multiphoton ionization (MPI) at 266 nm (approximately 5 x 10(exp 11) W/cm(sup 2) was used. Most notable among the results was the silicone contamination on Mg2 mirror 28-92, and that the Long Duration Exposure Facility (LDEF) paint sample had been enriched in K and Na and depleted in Zn, Si, B, and organic compounds relative to the control paint.

Becker, Christopher H.↗

Major Element Analysis of the Target Rocks at Meteor Crater, Arizona

We collected approximately 400 rock chips in continuous vertical profile at Meteor Crater, Arizona, representing, from bottom to top, the Coconino, Toroweap, Kaibab, and Moenkopi Formations to support ongoing compositional analyses of the impact melts and their stratigraphic source depth(s) and other studies at Meteor Crater that depend on the composition of the target rocks. These rock chips were subsequently pooled into 23 samples for compositional analysis by XRF (x ray fluorescence) methods, each sample reflecting a specific stratigraphic "subsection" approximately 5-10 in thick. We determined the modal abundance of quartz, dolomite, and calcite for the entire Kaibab Formation at vertical resolutions of 1-2 meters. The Coconino Formation composes the lower half of the crater cavity. It is an exceptionally pure sandstone. The Toroweap is only two inches thick and compositionally similar to Coconino, therefore, it is not a good compositional marker horizon. The Kaibab Formation is approximately 80 in thick. XRD (x ray diffraction) studies show that the Kaibab Formation is dominated by dolomite and quartz, albeit in highly variable proportions; calcite is a minor phase at best. The Kaibab at Meteor Crater is therefore a sandy dolomite rather than a limestone, consistent with pronounced facies changes in the Permian of SE Arizona over short vertical and horizontal distances. The Moenkopi forms the 12 in thick cap rock and has the highest Al2O3 and FeO concentrations of all target rocks. With several examples, we illustrate how this systematic compositional and modal characterization of the target ideologies may contribute to an understanding of Meteor Crater, such as the depth of its melt zone, and to impact cratering in general, such as the liberation of CO2 from shocked carbonates.

See, Thomas H.↗

Approaches of comparison for clear-sky radiative fluxes from general circulation models with Earth Radiation Budget Experiment data

In order to compare the clear-sky greenhouse effect and cloud-radiative forcing from general circulation models with Earth Radiation Budget Experiments (ERBE) data, it is necessary to calculate the general circulation model (GCM) clear-sky radiative fluxes in a way consistent with ERBE. This study discusses problems associated with the available methods for clear-sky radiative flux computations in GCMs and proposes a new approach, which uses a statistical relationship between the grid cloud cover and the availability of ERBE clear-sky measurement, established from ERBE pixel data, to sample the model radiative fluxes. Calculations with version 2 of the National Center for Atmospheric Research (NCAR) Community Climate Model using observed sea surface temperature (SST) show good agreement of clear-sky sampling from the proposed method with ERBE sampling. It is also shown that large improvements are achieved in the spatial variability of the model clear-sky radiative fluxes over ocean, with reference to ERBE, by using the new clear-sky sampling method.

Zhang, M. H.↗

Robust surfactant-assisted one-pot sample preparation for label-free single-cell and nanoscale proteomics

With advanced mass spectrometry (MS)-based proteomics, genome-scale proteome coverage can be achieved from bulk cells. However, such bulk measurement obscures cell to cell heterogeneity, precluding proteome profiling of single cells and small numbers of cells of interest. To address this issue, in recent 5 years there are a surge of small sample preparation methods developed for robust effective collection and processing of single cells and small numbers of cells for in-depth MS-based proteome profiling. Based on their broad accessibility, they can be categorized into two types: specific device- and standard PCR tube- or multi-well plate-based methods. Herein we describe the detailed protocol of our recently developed, easily adoptable, Surfactant-assisted One-Pot (SOP) sample preparation coupled with MS method termed SOP-MS for label-free single-cell and nanoscale proteomics. SOP-MS capitalizes on the combination of a MS-compatible surfactant, DDM (n-Dodecyl-ß-D-maltoside), and standard low-bind PCR tube or multi-well plate for ‘all-in-one’ one-pot sample preparation without sample transfer. With its robust and convenient features, SOP-MS can be readily implemented in any MS laboratory for single-cell and nanoscale proteomics. With further improvements in MS detection sensitivity and sample throughput, we believe that SOP-MS could open an avenue for single-cell proteomics with broad applicability in the biological and biomedical research.

Single-cell proteomics, nanoscale proteomics, SOP-↗

Mars Molecular and Isotopic Analysis Research Study

Recently, the Martian atmosphere and surface constituents have become of great interest. The Viking in situ gas chromatograph mass spectrometer experiment contributed greatly to our knowledge of the composition of the Martian atmosphere. However, important questions remain such as the abundance of water on Mars. The Viking experiment employed solid reagents to enhance their carbon measurements. Techniques of chemical conversion using simple solid reagents have advanced considerably in the past 20 years. In this investigation we researched the advancements in techniques to reversibly adsorb and desorb water and focused on the techniques potentially useful for the temperatures and pressures on the Martian surface. During the granting period from June 15, 1998 to August 14, 1998, a literature study of the material appropriate for use in a chemical conversion device and the availability of these materials were undertaken. The focus of this investigation was searching for methods and materials potentially useful in enhancing the measurements of water. Three different methods were considered for the means to extract water from a given gas sample. These methods included adsorption in a desiccant, adsorption on a clean metal surface, and adsorption in a carbon molecular sieve or zeolite. Each method was evaluated with feasibility and reversibility in mind. By far the simplest and perhaps cheapest way to remove water from a gaseous sample is by means of a bulk desiccant. Desiccants are commercially available from many companies including those that supply chemicals. The main feature of a desiccant is its ability to rapidly bind or absorb water from the atmosphere. Calcium chloride, for example, is frequently incorporated into drying tubes by organic chemists when reactions require the absence of water. Other desiccants include sodium hydroxide, calcium hydride, and commercial products such as Drierite, available from Aldrich Chemical. The disadvantage to most desiccants is a direct consequence of what makes them so advantageous. Desiccants rapidly and strongly bind water, often reacting chemically with it. This strong binding makes reversibly desorbing the water from the desiccant very difficult. The third method by which to absorb water from a gas sample involves the use of molecular sieves of other ziolites.

Manning, Heidi L. K.↗

Method Development for In-situ Detection of Latent Herpesvirus DNA from Saliva using Nanopore Sequencing

Research toward latent herpesvirus reactivation has been intensively addressed through Space Shuttle and International Space Station (ISS) investigations. This work has provided the understanding that persistent reactivation of herpesviruses from asymptomatic crew can be detected through viral shedding in saliva, urine, and blood. Occasionally, viral reactivation from the latency stage can pose a threat to crew health (clinical manifestation) before, during, and after flight missions. Furthermore, previous work detailing correlations with immunity indicate that monitoring viral reactivation could be implemented to assess potential immune dysfunction. While in-flight monitoring is desirable, there is no well-established procedure or method for real-time evaluations, and research to date has relied on postflight, ground-based analysis. The development of portable molecular technologies like the miniPCR™ (miniPCR Bio) thermal cycler and the MinION™ sequencer (Oxford Nanopore Technologies) have confirmed that real-time monitoring is possible in extreme and low resource environments. These devices, combined with simple sample preparation methods, have been used to demonstrate bacterial identification onboard the ISS, as well as rapid viral detection in remote locations on Earth. The work here builds upon previous molecular advancements onboard the ISS toward the development and validation of a spaceflight-compatible method for viral detection from crew samples. Several herpesviruses can be detected in saliva, which provides a non-invasive means to collect samples for monitoring. While the basis for this method lies in previous spaceflight investigations, key points for method optimization include DNA extraction from saliva, viral primer selection, and bioinformatic processes for data analysis. To increase viral yield, numerous DNA extraction methods have been evaluated and will be discussed in detail. For initial development and testing, varicella-zoster virus (VZV) is being targeted though open reading frame 51 and 63 (ORF51, ORF63), as the replication origin-binding protein is highly expressed during latency. Optimization of the thermal cycling parameters has resulted in the ability to test the entire process. The full method has been tested with both viral VZV DNA standards and saliva spiked with varying concentrations of VZV. Viral sequence data were mapped to the reference sequence using minimap2. Prior to mapping, DNA sequencing reads were filtered for length and quality, barcodes were removed, and alignment identity calculated. Following further assessments, statistics were compared across multiple sequencing experiments and are being used to determine the success of the protocols. Forward work will include the incorporation of herpes simplex virus 1 (HSV-1) and Epstein-Barr virus (EBV) primers as well as the validation of results to the terrestrial qPCR standard assay. Upon full validation of the developed method, saliva will be collected from 20 healthy subjects and spiked with viral DNA. These samples will be split and assayed with the MinION and standard qPCR assay.

Hang N Nguyen↗

Analyzing Multirate-Sampled Systems

New method available for monitoring stability of system on basis of data sampled at multiple rates--in particular, at two rates, one of which is twice frequency of other. Method is called Multirate Matrix Frequency Response (MMFR) analysis. MMFR was used in Space Shuttle to evaluate effect of decreasing sample rate of error loop in ascent-phase digital autopilot. Should also be useful to designers of other control systems and to structural, civil, and mechanical engineers for structure and vibration analysis.

Hendrix, N.↗

Spatial conductivity measurements on high T(sub c) superconducting films

High T(sub c) superconducting thin and thick films have potential applications in future NASA flight projects. In anticipation of film use, the Materials Branch is developing a nondestructive, non-contact method of measuring the spatial variation of conductivity across a film sample. This method uses a computer-controlled, X-Y positioning table to scan a conventional eddy current probe across the surface of a film. The induced changes in impedance caused by variations in film conductivity are recorded during the scanning process. Ultimately the two-dimensional data set is displayed using imaging equipment on a personal computer.

Vansant, J. Timothy↗

Development of a high-throughput method for processing sponge-stick samples to detect viable Bacillus anthracis spores

Since the national validation of the sponge-stick based method for detection of Bacillus anthracis spores in environmental samples, there have not been focused efforts to address the low throughput nature of the method, which processes only one sample at one time. Sample processing remains a serious bottleneck for rapidly analyzing large numbers of samples expected from a biological warfare attack. Therefore, we developed a high-throughput method to simultaneously process multiple sponge-stick samples to be better prepared for rapid response and recovery after wide area anthrax incidents. In this method, sponges are placed in 50 mL tubes containing 25 mL extraction buffer and shaken to release spores, after which the suspension is recovered for analysis. Here, we determined that an additional extraction step, conducted in the same tubes with 10 mL buffer, further increased spore recovery from sponge-stick by approximately 10 %. We determined that orbital shaking and multi-tube vortexing were both more effective than reciprocating shaking for recovering spores. We conducted simultaneous processing of up to 12 sponge-stick samples and demonstrated comparable spore recovery efficiencies to the traditional low-throughput stomacher-based method (approximately 60 % recovery at 10 2 -spore level and 75 % recovery at 10 4 -spore level for both methods in three replicate experiments, P > 0.05 for two-tailed t-tests for each experiment and spore level). We also demonstrated that our high-throughput method could be integrated with Rapid Viability-Polymerase Chain Reaction (RV-PCR) analysis and could detect levels as low as 40 spores per sponge even when challenged by a PCR particulate contaminant.

Anthrax↗