Search NASA⌕ Search

SEARCH · Search NASA

Results for “scale analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Description and Use of SCALE Sampler Parametric Capability for Engineering Analysis and Optimization

The Sampler sequence was introduced into the SCALE nuclear modeling and simulation suite in SCALE 6.2 to perform uncertainty quantification via random sampling of nuclear data, material number densities, and dimensions. Sampler was expanded with the introduction of a parametric capability in SCALE 6.2.2. This paper discusses input for the Sampler parametric sequence and presents two case studies of analyses performed using the sequence. These case studies include preconceptual design of a package for transporting high assay low-enriched uranium (HALEU) oxide and scoping calculations to support subcritical limit development for a future update of the ANSI/ANS-8.1 (ANS-8.1) standard. The parametric capability within Sampler provides many benefits to analysts. For instance, parametric sweeps are frequently used to identify optimum parameter values as part of safety analysis or system design, but such sweeps can require substantial engineering time or may rely on custom-written scripts or scripts such as Write One, Run Many (or WORM) developed outside of any software quality assurance program. With the parametric capabilities in Sampler, however, a large number of inputs can be generated automatically without recourse to scripting by individual analysts. The parametric capability can also be used in lieu of the CSAS5S search sequence to identify optimum parameters more simply with straightforward inputs and outputs. Sampler can also be used to calculate input parameters from engineering specifications. For example, diameters can be converted to radii, or masses can be used to calculate number densities. Overall, the Sampler parametric capability provides a robust feature within SCALE, eliminating the need for user-developed scripting.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Microbial diversity analysis of two full-scale seawater desalination treatment trains provides insights into detrimental biofilm formation

Detrimental biofilms on RO membranes remain a crucial challenge for seawater desalination. Comparative analysis of 16S rRNA gene amplicon sequencing data revealed differences and commonalities of biofilm communities associated with unit operations in the two largest seawater desalination facilities in the U.S., the Claude "Bud" Lewis Carlsbad Desalination Plant and the Tampa Bay Seater Desalination facility. At both plants, feedwater collected at a single time point was a poor indicator of the RO membrane communities, which showed far greater taxa diversity. The analysis of prefilter cartridges from the Carlsbad plant revealed similarly high taxon diversity as the RO module biofilms, with relevant differences. Algal sequences were enriched on the prefilter cartridges as were sequences representing Bdellovibrionota, which are predatory bacteria. Sequences representing opportunistic Gammaproteobacteria (i.e., Shewanella, Woesia) were present in significantly higher relative abundance on the RO membranes than in the prefilter cartridges, suggesting growth of certain taxa in the RO modules. Untargeted metabolomics distinguished intra- and inter-desalination plant biofilm samples, highlighting the potential value of this tool for biofilm monitoring. These findings underscore the value of omics tools for effective microbial monitoring, to understand biofouling dynamics within RO desalination plants, and to provide insight for the development of ecologically-informed biofilm control measures.

59 BASIC BIOLOGICAL SCIENCES↗

The origin of CEMA and its relation to CSP

Currently, there exist two methods for analysing an explosive mode introduced by chemical kinetics in a reacting process: the Computational Singular Perturbation (CSP) algorithm and the Chemical Explosive Mode Analysis (CEMA). CSP was introduced in 1989 and addressed both dissipative and explosive modes encountered in the multi-scale dynamics that characterize the process, while CEMA was introduced in 2009 and addressed only the explosive modes. It is shown that (i) the algorithmic tools incorporated in CEMA were developed previously on the basis of CSP and (ii) the examination of explosive modes has been the subject of CSP-based works, reported before the introduction of CEMA.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Constraints on S 8 from a full-scale and full-shape analysis of redshift-space clustering and galaxy–galaxy lensing in BOSS

ABSTRACT We present a novel simulation-based cosmological analysis of galaxy–galaxy lensing and galaxy redshift-space clustering. Compared to analysis methods based on perturbation theory, our simulation-based approach allows us to probe a much wider range of scales, $0.4 \, h^{-1} \, \mathrm{Mpc}$ to $63 \, h^{-1} \, \mathrm{Mpc}$, including highly non-linear scales, and marginalizes over astrophysical effects such as assembly bias. We apply this framework to data from the Baryon Oscillation Spectroscopic Survey LOWZ sample cross-correlated with state-of-the-art gravitational lensing catalogues from the Kilo Degree Survey and the Dark Energy Survey. We show that gravitational lensing and redshift-space clustering when analysed over a large range of scales place tight constraints on the growth-of-structure parameter $S_8 = \sigma _8 \sqrt{\Omega _{\rm m} / 0.3}$. Overall, we infer S8 = 0.792 ± 0.022 when analysing the combination of galaxy–galaxy lensing and projected galaxy clustering and S8 = 0.771 ± 0.027 for galaxy redshift-space clustering. These findings highlight the potential constraining power of full-scale studies over studies analysing only large scales and also showcase the benefits of analysing multiple large-scale structure surveys jointly. Our inferred values for S8 fall below the value inferred from the CMB, S8 = 0.834 ± 0.016. While this difference is not statistically significant by itself, our results mirror other findings in the literature whereby low-redshift large-scale structure probes infer lower values for S8 than the CMB, the so-called S8-tension.

79 ASTRONOMY AND ASTROPHYSICS↗

ResStock: Annual Baseline Results with Component Loads

The ResStock Analysis Tool was developed by NREL with support from the U.S. Department of Energy to provide a new approach to large-scale residential analysis by combining large public and private data sources, statistical sampling, detailed sub hourly building simulations, and high-performance computing. This combination achieves unprecedented granularity and accuracy in modeling the diversity of the housing stock and the distributional impacts of building technologies in different communities. The annual baseline energy results from a national-scale ResStock run use typical meteorological year 3 (TMY3) files for energy simulations. Results include heating and cooling loads for individual components of each building. Component loads describe the heating/cooling load that can be attributed to specific elements of a home, such as heat transfer through walls or internal gains. Additionally, these results include the standard ResStock outputs for housing characteristics and numerous energy outputs by end-use and fuel. A snapshot of the ResStock version used to produce this data, including a configuration file for the run can be found using the Source Code resource link.

Array↗

Scale-up and techno-economic analysis of microbial electrolysis cells for hydrogen production from wastewater

Microbial electrolysis cells (MECs) have demonstrated high-rate H 2 production while concurrently treating wastewater, but the transition in scale from laboratory research to systems that can be practically applied has encountered challenges. It has been more than a decade since the first pilot-scale MEC was reported, and in recent years, many attempts have been made to overcome the barriers and move the technology to the market. This study provided a detailed analysis of MEC scale-up efforts and summarized the key factors that should be considered to further develop the technology. We compared the major scale-up configurations and systematically evaluated their performance from both technical and economic perspectives. We characterized how system scale-up impacts the key performance metrics such as volumetric current density and H 2 production rate, and we proposed methods to evaluate and optimize system design and fabrication. In addition, preliminary techno-economic analysis indicates that MECs can be profitable in many different market scenarios with or without subsidies. Here, we also provide perspectives on future development needed to transition MEC technology to the marketplace.

42 ENGINEERING↗

A Scale‐Adaptive Urban Hydrologic Framework: Incorporating Network‐Level Storm Drainage Pipes Representation

Abstract Below‐ground urban stormwater networks (BUSNs) significantly influence urban flood dynamics, yet their representation at the watershed or larger scales remains challenging. We introduce a scalable urban hydrologic framework that centers on a novel network‐level BUSN representation, balancing the needs for physical basis, parameter parsimony, and computational efficiency. Our framework conceptualizes an urban watershed into four interacting zones: hillslopes (natural), storm‐sewersheds (urban), a sub‐network channel (tributaries), and a main channel. We develop an innovative Graph Theory‐based algorithm to derive network‐level BUSN parameters from publicly available datasets, enabling efficient, scalable parameterization. We demonstrate this framework's applicability at nine representative watersheds in the Houston metropolitan region, USA, with urban imperviousness ranging from 0% to 64% and drainage areas ranging from 24 to 302 . Our model achieves satisfying computational efficiency, completing hourly time step simulations for 18 years in less than 5 sec per watershed on a standard PC. Validation against observed daily streamflow confirms that the model can capture small‐to‐large flood peaks and seasonal and annual water balance over these watersheds. Comparisons with the National Water Model show better performance in predicting flood peaks and overall water balance, underscoring the promises of our new framework for urban hydrologic modeling at large scales. Furthermore, analysis reveals nonlinear relationships between BUSNs' designed capacities and flood reduction effects. Our approach bridges the gap between detailed hydraulic and large‐scale hydrologic models, providing a valuable tool for urban flood prediction and management across broader spatial and temporal scales.

54 ENVIRONMENTAL SCIENCES↗

Statistical properties of homogeneous and isotropic turbulence in He II measured via particle tracking velocimetry

Despite being a quantum two-fluid system, superfluid helium-4 (He II) is observed to behave similarly to classical fluids when a flow is generated by mechanical forcing. This similarity has brought up the feasibility of utilizing He II for high Reynolds number classical turbulence research, considering the small kinematic viscosity of He II. However, it has been suggested that the nonclassical dissipation mechanism in He II at small scales may alter its turbulent statistics and intermittency. In this work, we report our study of a nearly homogeneous and isotropic turbulence (HIT) generated by a towed grid in He II. We measure the velocity field using particle tracking velocimetry with solidified deuterium particles as the tracers. By correlating the velocities measured simultaneously on different particle trajectories or at different times along the same particle trajectory, we are able to conduct both Eulerian and Lagrangian flow analyses. Spatial velocity structure functions obtained through the Eulerian analysis show scaling behaviors in the inertial subrange similar to that for classical HIT but with enhanced intermittency. The Lagrangian analysis allows us to examine the flow statistics down to below the dissipation length scale. Interestingly, abnormal deviations from the classical scaling behaviors are observed in this regime. Lastly, we discuss how these deviations may relate to the motion of quantized vortices in the superfluid component in He II.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The Analysis Description Language Ecosystem: Latest developments and physics applications

We present latest developments in Analysis Description Language (ADL), a declarative domain-specific language describing the physics algorithm of a HEP data analysis decoupled from software frameworks. Analyses written in ADL can be integrated into any framework for various tasks. ADL is a multipurpose construct with uses ranging from analysis design to preservation, reinterpretation, queries, visualisation, combination, etc. The most advanced infrastructure to execute ADL on events is the CutLang runtime interpreter. Recent technical developments include an automated interface with different data types, generation of the abstract syntax tree, a visualization tool that that auto-converts analysis flows to graphs, incorporation of trained machine learning models and a Jupyter-based plotting tool. We also report physics implications including a large scale LHC analysis implementation and validation effort for beyond the standard model reinterpretation purposes and studies with ATLAS and CMS open data.

Sekmen, Sezen [Kyungpook National Univ., Daegu (Ko↗

Observability Analysis of a Power System Stochastic Dynamic Model Using a Derivative-Free Approach

Serving as a prerequisite to power system dynamic state estimation, the observability analysis of a power system dynamic model has recently attracted the attention of many power engineers. However, because this model is typically nonlinear and large-scale, the analysis of its observability is a challenge to the traditional derivative-based methods. Indeed, the linear-approximation-based approach may provide unreliable results while the nonlinear-technique-based approach inevitably faces extremely complicated derivations. Furthermore, because power systems are intrinsically stochastic, the traditional deterministic approaches may lead to inaccurate observability analyses. In this work, facing these challenges, we propose a novel polynomial-chaos-based derivative-free observability analysis approach that not only is free of any linear approximations, but also accounts for the stochasticity of the dynamic model while bringing a low implementation complexity. Furthermore, this approach enables us to quantify the degree of observability of a stochastic model, what conventional deterministic methods cannot do. The excellent performance of the proposed method has been demonstrated by performing extensive simulations using a synchronous generator model with IEEE-DC1A exciter and the TGOV1 turbine governor.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Steam Condensation Scaled Experiment in the Presence of Non-condensable Gas for Reactor Containment Passive Safety Analysis

This study presents scaled experiments using steam condensation with non-condensable gas (NCG)—helium, simulating hydrogen—as these experiments are pivotal for water-cooled reactor passive containment cooling system (PCCS) design and analysis. Research into PCCSs for small modular reactors (SMRs) is especially important in light of SMR system design; however, studies in the literature reflect limitations due to test geometry and operational condition variations, without considering SMR prototypic design. To address these challenges, a scaled test facility was developed to accurately replicate SMR PCCSs. This facility includes vertical down-flow condensing test sections with 1-, 2-, and 4-in.-diameter condensing tubes, accompanied by annular water cooling. Experiments were conducted using both superheated and saturated steam, with steam mass flow rates varying from 55 to 66 kg/hr., in the presence of helium as the NCG mass flow rate ranges from 1.8 to 22 kg/hr. Test data were collected on (a) the axial temperatures of the annular cooling water; (b) the outer wall temperature of the condensers; and (c) the mass flow rate, temperature, and pressure at the test section inlets and outlets. These primary test data were used in conjunction with a standard data reduction methodology to estimate essential thermal parameters such as heat fluxes, heat transfer coefficients, and condensation rates. The effects of NCGs on steam condensation within the geometry of the scaled test sections were then presented in regard to various testing conditions.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Presentation: Steam Condensation Scaled Experiment in the Presence of Non-condensable Gas for Reactor Containment Passive Safety Analysis

This study presents scaled experiments using steam condensation with non-condensable gas (NCG)—helium, simulating hydrogen—as these experiments are pivotal for water-cooled reactor passive containment cooling system (PCCS) design and analysis. Research into PCCSs for small modular reactors (SMRs) is especially important in light of SMR system design; however, studies in the literature reflect limitations due to test geometry and operational condition variations, without considering SMR prototypic design. To address these challenges, a scaled test facility was developed to accurately replicate SMR PCCSs. This facility includes vertical down-flow condensing test sections with 1-, 2-, and 4-in.-diameter condensing tubes, accompanied by annular water cooling. Experiments were conducted using both superheated and saturated steam, with steam mass flow rates varying from 55 to 66 kg/hr., in the presence of helium as the NCG mass flow rate ranges from 1.8 to 22 kg/hr. Test data were collected on (a) the axial temperatures of the annular cooling water; (b) the outer wall temperature of the condensers; and (c) the mass flow rate, temperature, and pressure at the test section inlets and outlets. These primary test data were used in conjunction with a standard data reduction methodology to estimate essential thermal parameters such as heat fluxes, heat transfer coefficients, and condensation rates. The effects of NCGs on steam condensation within the geometry of the scaled test sections were then presented in regard to various testing conditions.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A Scalable Parallel Hypergraph Generator (HyGen)

Graphs are extensively used to model real-world complex systems. An edge in a graph can model pairwise relationships. However, multiway relationships (connections between three or more vertices) are common in many complex systems such as cellular process, image segmentation, and circuit design. A graph edge cannot model multiway relationships. A hypergraph, which can connect more than two vertices, is thus a better option to model multiway relationships. A large-scale hypergraph analysis has the potential to find useful insights from a complex system and assist in knowledge discovery. Currently a limited number of hypergraphs exists that are representative of real-world datasets. Moreover, real-world hypergraph datasets are small in size and inadequate to incorporate future needs. A graph generator that can produce large-scale synthetic hypergraphs can solve the above mentioned problems. In this paper, we present a scalable parallel hypergraph generator (HyGen) based on the Message Passing Interface (MPI) standard. To generate hypergraphs, HyGen takes the following parameter values as inputs: i) number of vertices, ii) number of hyperedges, iii) number of clusters, iv) vertex distribution, v) hyperedge distribution, vi) local cluster cardinality, and vii) global cluster cardinality. We have demonstrated that HyGen can generate hypergraphs of various sizes in a scalable fashion. HyGen takes approximately four minutes to generate a hypergraph with 4.8 million vertices, 1.6 million hyperedges, and 800 clusters using 1,024 processes on a leadership class computing platform. Our strong and weak scaling experiments on supercomputers demonstrate that HyGen can quickly create large-scale hypergraphs in a parallel manner, thus providing a useful capability for hypergraph analysis.

Hasan, S M Shamimul↗

Heterogeneity or illusion? Track the carbon Kuznets curve of global residential building operations

Residential buildings, the “last mile” sector in the global decarbonization, have become the most significant uncertain factor hindering carbon neutrality with increasing household energy demand. To track the operational carbon in buildings, this study investigates the carbon Kuznets curve (CKC) and the corresponding decoupling status of residential building operations at four emission scales by using the data of 30 countries from 2000 to 2019. The results show that (1) the CKC model can fit more than half of the samples. Most curves have an inverted U-shape, with 76% of emission per household and 82% of total emissions. (2) In the presence of the CKC, over four-fifths of global residential buildings peak regardless of any emission scale. The analysis denotes that the carbon emissions of developed countries reach their peaks earlier. In the total emissions, the samples’ peaking proportion is 20% and 25% with income per capita < 20,000 United States dollars (USD) and 20,000–40,000 USD, respectively. (3) The Tapio decoupling analysis and the threshold regression effectively verify the robustness and the heterogeneity of CKCs, respectively. Strong decoupling effects of CKCs in most countries are demonstrated at the scales of emission per floor space and the total emissions, and the heterogeneity proves the classic inverted U-shaped relationship between economy and emissions doesn’t exist in all emitters. Overall, this study tracks the historical carbon emission trajectories of residential building operations at a global scale, providing reference for different economies to simulate the dynamic of building carbon emissions along with the economic booming.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis of HolosGen Sub-Scale Simulator with Plant Dynamics Code

The Subcritical Power Module Sub-scale Simulator (SPM-SS) has been designed and constructed by HolosGen LLC under the ARPA-E MEITNER program to simulate the thermal-hydraulic and heat transfer behavior of the full-scale Holos-Quad Subcritical Power Modules (SPMs). Four coupled SPMs, each rated at 5.5MW, form the Holos-Quad gas-cooled microreactor design. The SPM-SS represents a substantially scaled-down system with a power rating less than 40 kW, equipped with an electrically heated fuel cartridge heat exchanger, an electrically heated compressor heat exchanger, and a valve actuated turbine heat exchanger, in addition to a recuperator and a cooler heat exchanger. The fuel cartridge represents a portion of the full-scale SPM core, the compressor heat exchanger mimics the temperature changes resulting from the compressor’s turbomachinery inefficiencies, the turbine heat exchanger mimics the expansion process normally occurring through the turbine, while the recuperator and cooler heat exchangers complete the subscale simulator loop. The heaters equipping the fuel cartridge and the compressor heat exchangers are electronically controlled to simulate normal and off-normal SPM operating conditions. The full-scale Holos-Quad SPM design eliminates the traditional balance of plant and executes thermal-to-electric energy conversion by means of an intercooled Brayton cycle with decoupled compressor-turbine turbomachinery. The Holos-Quad full-scale design is equipped with a multi-stage axial Low- and High-Pressure compressor, and a multistage axial turbine. The SPM-SS is designed for testing and validation of selected components which are instead coupled by a traditional balance of plant. The SPMSS is not equipped with turbo-machinery (compressor and turbine) as the development of these components were excluded from the scope of work under the ARPA-E MEITNER funding program. The SPM-SS balance of plant enables modifications, replacement and testing of individual components with different working fluids and is designed to include the turbo-machinery components that will be developed in future research . The SPM-SS can be operated with different gases, variable mass-flow-rates, pressures, and temperatures to obtain test data for selected components, whose performance can be scaled to validate the computer model of the full-scale SPM at various conditions (e.g., start-up, transients conditions). The SPM-SS can operate at the maximum Holos-Quad design pressure of 7 MPa, and a maximum temperature limited to 650 °C by the electrical heaters. Several SPM-SS tests have been conducted and analyzed with the Plant Dynamics Code (PDC) developed at the Argonne National Laboratory (ANL). These tests aimed at validating the PDC modeled predictions of the full-scale Holos-Quad design with data from selected SPM-SS components. In order to address SPM-SS specific characteristics, such as components heat losses and absence of turbomachinery components, some modifications to the PDC have been implemented to factor the design differences from the full-scale Holos-Quad SPM to the SPM-SS. As the PDC offers capabilities to analyze systems with different working fluids, air, nitrogen, and helium were utilized as the SPM-SS working fluids. Air was utilized to fine-tune the SPM-SS Systems Structures and Components (SSCs), nitrogen was utilized to pressure test the SPM-SS loop at the SPMs design maximum pressure of 7MPa. Helium was utilized as the working fluid circulating through the SPM-SS SSCs for specific tests to validate the PDC predictions of the fuel cartridge heat exchanger. SPM-SS tests data were also analyzed with both the steady-state and transient analysis capabilities offered by the PDC. This report describes the PDC analysis of the SPM-SS tests data, including the necessary code modifications and comparison of the code results with the experimental data. Based on the results, a discussion is presented on how the analysis supports design and transient calculations of the full-scale Holos-Quad microreactor. Also based on the results of this work, recommendations are made for future optimizations of the SPM-SS components and PDC model development needs.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Ceramic Membrane Solar Desal: Pilot System Design and Full-Scale System Techno-Economic Analysis (CRADA Final Report)

This work is conducted in support of the American Made Challenges Solar Prize. The current scope addresses the Design portion of the overall prize competition. This team, led by the University of Connecticut, will design a solar powered, pilot scale, ceramic-based membrane distillation system that can operate on high salinity waters and propose that design for construction in the Test phase of the Prize competition.

14 SOLAR ENERGY↗

Advanced surrogate model for electron-scale turbulence in tokamak pedestals

We derive an advanced surrogate model for predicting turbulent transport at the edge of tokamaks driven by electron temperature gradient (ETG) modes. Our derivation is based on a recently developed sensitivity-driven sparse grid interpolation approach for uncertainty quantification and sensitivity analysis at scale, which informs the set of parameters that define the surrogate model as a scaling law. Our model reveals that ETG-driven electron heat flux is influenced by the safety factor q, electron beta β e and normalized electron Debye length λ D , in addition to well-established parameters such as the electron temperature and density gradients. To assess the trustworthiness of our model's predictions beyond training, we compute prediction intervals using bootstrapping. The surrogate model's predictive power is tested across a wide range of parameter values, including within-distribution testing parameters (to verify our model) as well as out-of-bounds and out-of-distribution testing (to validate the proposed model). Overall, validation efforts show that our model competes well with, or can even outperform, existing scaling laws in predicting ETG-driven transport.

fusion plasma↗