Search NASA⌕ Search

SEARCH · Search NASA

Results for “scoring system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

NASA's EOSDIS, Trust and Certification

NASA's Earth Observing System Data and Information System (EOSDIS) has been in operation since August 1994, managing most of NASA's Earth science data from satellites, airborne sensors, filed campaigns and other activities. Having been designated by the Federal Government as a project responsible for production, archiving and distribution of these data through its Distributed Active Archive Centers (DAACs), the Earth Science Data and Information System Project (ESDIS) is responsible for EOSDIS, and is legally bound by the Office of Management and Budgets circular A-130, the Federal Records Act. It must follow the regulations of the National Institute of Standards and Technologies (NIST) and National Archive and Records Administration (NARA). It must also follow the NASA Procedural Requirement 7120.5 (NASA Space Flight Program and Project Management). All these ensure that the data centers managed by ESDIS are trustworthy from the point of view of efficient and effective operations as well as preservation of valuable data from NASA's missions. Additional factors contributing to this trust are an extensive set of internal and external reviews throughout the history of EOSDIS starting in the early 1990s. Many of these reviews have involved external groups of scientific and technological experts. Also, independent annual surveys of user satisfaction that measure and publish the American Customer Satisfaction Index (ACSI), where EOSDIS has scored consistently high marks since 2004, provide an additional measure of trustworthiness. In addition, through an effort initiated in 2012 at the request of NASA HQ, the ESDIS Project and 10 of 12 DAACs have been certified by the International Council for Science (ICSU) World Data System (WDS) and are members of the ICSUWDS. This presentation addresses questions such as pros and cons of the certification process, key outcomes and next steps regarding certification. Recently, the ICSUWDS and Data Seal of Approval (DSA) organizations merged their Core Trustworthy Data Repositories Requirements and require that members be recertified every three years. Given the rigor with which NASA manages the ESDIS Project and the DAACs, the recertification through WDSDSA, while involving some additional work, is a relatively simple process.

Certification↗

A robust alloy design (RAD) strategy for next-generation (IV) nuclear fission reactors

Next-generation nuclear reactors demand structural materials capable of withstanding extreme conditions, including high temperatures, intense neutron flux, and corrosive environments. Multi-Principal Element Alloys (MPEAs) have emerged as promising candidates due to their exceptional radiation tolerance, thermal stability, and compositional flexibility. This study introduces a versatile and customizable Robust Alloy Design (RAD) strategy for systematically designing MPEAs for GEN-IV reactor fuel cladding. The RAD framework integrates nuclear-relevant selection criteria, empirical parameter assessments, and high-throughput CALPHAD simulations to efficiently narrow compositional space and identify stable alloys. A unified RAD score developed for the first time, combines key performance metrics, including fuel-clad chemical interaction (FCCI), neutron absorption cross-section (NAC), valence electron configuration (VEC), and melting point factor (MPF), into a flexible ranking system adaptable to reactor-specific priorities. Among 724 candidates, V555(5Al–5Cr–5Fe–85V) emerged as the top alloy, validated experimentally with a homogeneous single-phase BCC microstructure and superior mechanical properties (nano-indentation: 3.389 ± 0.258 GPa; Vickers hardness: 240 ± 6.7 HV), significantly outperforming Zircaloy-4 and V-4Cr-4Ti. Importantly, the RAD strategy is not limited to nuclear applications; its customizable weighting system enables scalability to other extreme environments. This adaptability positions RAD strategy as a versatile tool for advanced materials design across multiple industries.

Alloy design↗

From Bricks to Clicks: Mapping the White Space in Building Innovation

It is a critical national imperative to transform the buildings sector, yet innovation is impeded by deployment failures that leave promising technologies stranded. Conventional market reports and techno-economic analysis provide an insufficient understanding of markets and resource allocation for emerging building technologies. They omit crucial commercialization factors such as ecosystem maturity and adoption friction, where the coordinated participation of a network of suppliers, contractors, financiers, regulators, and integrators is required to scale solutions. This study addresses these gaps by introducing an evaluation framework grounded in front-line data from six years of the DOE's IMPEL incubator, comprising experience from 300 building-sector innovators and the adjacent, complex ecosystem. Our methodology synthesizes top-down market analysis with bottom-up, practitioner-level data across five megatrends: (M1) Affordable materials and industrialized construction; (M2) Healthy and efficient mechanical systems; (M3) Intelligent building operations; (M4) Buildings as grid assets; and (M5) High-density power and cooling for data centers and therein identify twelve "white space" technology opportunities. Next, we develop a multi-criteria scoring rubric to rank these opportunities based on parameters, i.e., Affordability, Quality of Life, Reliability, and Security, yielding composite ‘Demand’ and ‘Maturity’ indices. Our results indicate that the most significant white spaces may not be incremental products but a new class of ‘Ecosystem Enablers’, such as logistics platforms, orchestration layers, and automated compliance software that solve structural deployment gaps. This paper summarizes this transparent, evidence-based, practitioner-informed evaluation framework for policymakers and investors to re-evaluate policy and resource allocation and unlock scalable market transformation.

Singh, Reshma↗

The 60 GHz antenna system analyses for intersatellite links, phase A

A tradeoff study for 60 GHz antenna systems applicable to an advanced Tracking and Data Acquisition System is also discussed. A conceptual design of a preferred antenna system is also discussed. The tradeoff results for four types of antenna systems are presented: (1) Reflector/fixed feed, (2) Mechanical scan, (3) Electronic scan; and (4) Hybrid mechanical/electronic scan. The 12 candidate antennas were assessed on the basis of a preliminary design and a performance analysis then were scored against 15 weighted parameters. This process resulted in the ranking of the 12 candidates for the two applications, namely, for the geostationary TDAS only with a narrow field of view and for low orbit user satellites with a wide field of view.

Source record↗

Understanding the Uncertainty in the Technical Performance Level Assessment for Wave Energy

In recent years, the design and development of wave energy converters (WECs) has been explored with intense interest, with highly varying design concepts emerging globally across both research enterprises and industry. The design space for WECs is vast - many concepts ranging in functionality, control systems, power development systems, materials, and scale have been ideated and prototyped, but WEC technology has yet to converge. One critical element of the technology trajectory that governs the speed of adoption is the performance of a WEC concept. In analogous but more-established industries (such as aerospace, and environmentally sustainable electronics design), performance assessment is a quantitative method, based on historical data, that is used as an iterative tool to improve the design of these systems early on in the design process. Though more nascent than these approaches, in wave energy R&D, WEC performance has been assessed using the Technology Performance Level (TPL) assessment, which provides designers with a quantitative score, situating a grid-scale WEC concept on a scale from 1-9 (1 being the lowest performance, and 9 being the highest, trending with the oft-used Technology Readiness Level, or TRL). The TPL assessment is designed to be used during design iteration, when a WEC concept is fully ideated, to enable designers to consider potential means of improving the downstream performance of the concept. One concern that may be slowing the adoption of TPL among WEC developers is the inherent uncertainty in the assessment, and how uncertainty in the individual questions asked as part of the assessment may contribute to perceived inaccuracies in the final score. In this work, we explore the uncertainty present in the assessment and quantify this uncertainty using both traditional mathematical operations and a Monte Carlo simulation. Results imply areas of improvement of the TPL assessment, where reducing uncertainty will be most helpful to end users, enabling both TPL practitioners and users to understand with more accuracy those design elements that can be improved to impact device performance most substantively.

techno-economic analysis↗

Data-driven emulation of modal aerosol microphysics via neural operator-based modeling

The complexity and the small characteristic scales of aerosol microphysical processes pose a big challenge for accurate and efficient Earth system simulations at regional and global scales. In this work, we construct and evaluate a surrogate model: the aerosol deep operator network (ADON), a physics-inspired dual-net architecture for emulating the aerosol microphysics parameterization suite in the version 2 of the Energy Earth System Model (E3SMv2). The current version of the surrogate model is trained on a dataset comprising 9.8 million samples obtained from a global E3SMv2 simulation with the horizontal resolution of about one degree under cloud-free conditions. Incorporating domain spatial and temporal coordinates, as well as principle components extracted from training data, the dual-net surrogate model effectively captures the intricate representations of aerosol and the relationship with atmospheric state variables, achieving an R-squared score over $$95.7\%$$ for all the lognormal aerosol modes in the extrapolated regime. The validated model provides feature importance of input variables and their impact on the predictive capacity of the surrogate model in relation to the E3SM. The computational cost of online inference time deployed on CPUs and GPUs with lower precisions highlights ADON’s efficiency and potential in robust predictive modeling for large-scale Earth system computations.

Bai, Zhe↗

Estimate of the Mass and Radial Profile of the Orphan–Chenab Stream's Dwarf-galaxy Progenitor Using MilkyWay@home

We fit the mass and radial profile of the Orphan–Chenab Stream's (OCS) dwarf-galaxy progenitor by using turnoff stars in the Sloan Digital Sky Survey and the Dark Energy Camera to constrain N-body simulations of the OCS progenitor falling into the Milky Way on the 1.5 PetaFLOPS MilkyWay@home distributed supercomputer. We infer the internal structure of the OCS's progenitor under the assumption that it was a spherically symmetric dwarf galaxy composed of a stellar system embedded in an extended dark matter halo. We optimize the evolution time, the baryonic and dark matter scale radii, and the baryonic and dark matter masses of the progenitor using a differential evolution algorithm. The likelihood score for each set of parameters is determined by comparing the simulated tidal stream to the angular distribution of OCS stars observed in the sky. We fit the total mass of the OCS's progenitor to (2.0 ± 0.3) × 10 7 M ⊙ with a mass-to-light ratio of γ = 73.5 ± 10.6 and (1.1 ± 0.2) × 10 6 M ⊙ within 300 pc of its center. Within the progenitor's half-light radius, we estimate a total mass of (4.0 ± 1.0) × 10 5 M ⊙ . We also fit the current sky position of the progenitor's remnant to be (α, δ) = ((166.0 ± 0.9)°, (–11.1 ± 2.5)°) and show that it is gravitationally unbound at the present time. The measured progenitor mass is on the low end of previous measurements and, if confirmed, lowers the mass range of ultrafaint dwarf galaxies. Our optimization assumes a fixed Milky Way potential, OCS orbit, and radial profile for the progenitor, ignoring the impact of the Large Magellanic Cloud.

79 ASTRONOMY AND ASTROPHYSICS↗

Multiperspective analysis and testing of expert systems

The paper describes a technique which the author developed for testing expert systems. The technique, which he calls multiperspective testing, can be applied during both the knowledge engineering phase and the acceptance testing phase of developing an exppert system. The first step in multiperspective testing is to define a group of performance measures ('perspectives') that focus on the behavior of the knowledge base. For each such measure, the results of testing are summarized in four scores, which the author calls 'expansion,' 'detection,' 'discrimination,' and 'comprehension.' These scores have the advantage of providing more specific information about how the knowledge base should be updated or corrected.

Bollinger, Terry B.↗

A machine learning pipeline for identifying infiltration managed aquifer recharge locations from satellite imagery in the San Joaquin Valley, California

This study focuses on an agricultural region in California’s Central Valley, USA, where Managed Aquifer Recharge (MAR) is widely implemented to mitigate groundwater depletion under increasing water demand and climate variability. A deep learning and machine learning framework was developed to identify infiltration-MAR locations using satellite imagery and environmental data. The framework integrates surface water detection from Sentinel-2 imagery, geospatial delineation of water bodies, spatiotemporal tracking of water body dynamics, and supervised classification using meteorological, environmental, and topographic variables. The framework was applied to a 2379 km² study area southwest of Fresno, where 765 water bodies were detected, including 139 identified MAR sites based on publicly available datasets and expert knowledge. The classification model achieved an accuracy of 0.94 and an F1 score of 0.85. Feature importance analysis indicates that cropland, normalized difference vegetation index (NDVI), and evaporation are among the most influential predictors for infiltration-MAR. Notably, the framework suggests that engineered water management in infiltration-MAR systems can disrupt or even reverse the expected positive correlation between surface water extent and precipitation. These findings provide physically interpretable insights into the characteristics of existing infiltration-MAR facilities and demonstrate the potential of the proposed framework as a reproducible, interpretable, and potentially transferable tool for data-driven infiltration-MAR identification and inventory development under growing climatic and hydrological uncertainty.

Classification↗

Accelerating detector simulations with Celeritas: Profiling and performance optimizations

Celeritas is a GPU-optimized Monte Carlo (MC) particle transport code designed to meet the growing computational demands of next-generation high energy physics (HEP) experiments. It provides efficient simulation of electromagnetic (EM) physics processes in complex geometries with magnetic fields, detector hit scoring, and seamless integration into Geant4-driven applications to offload EM physics to GPUs. Recent efforts have focused on performance optimizations and expanding profiling capabilities. This paper presents some key advancements, including the integration of the Perfetto system profiling tool for detailed performance analysis and the development of track-sorting methods to improve computational efficiency.

Lund, Amanda [Argonne National Laboratory (ANL)]↗

Shotgun Immunoproteomic Approach for the Discovery of Linear B-Cell Epitopes in Biothreat Agents Francisella tularensis and Burkholderia pseudomallei

Peptide-based subunit vaccines are coming to the forefront of current vaccine approaches, with safety and cost-effective production among their top advantages. Peptide vaccine formulations consist of multiple synthetic linear epitopes that together trigger desired immune responses that can result in robust immune memory. The advantages of linear compared to conformational epitopes are their simple structure, ease of synthesis, and ability to stimulate immune responses by means that do not require complex 3D conformation. Prediction of linear epitopes through use of computational tools is fast and cost-effective, but typically of low accuracy, necessitating extensive experimentation to verify results. On the other hand, identification of linear epitopes through experimental screening has been an inefficient process that requires thorough characterization of previously identified full-length protein antigens, or laborious techniques involving genetic manipulation of organisms. In this study, we apply a newly developed generalizable screening method that enables efficient identification of B-cell epitopes in the proteomes of pathogenic bacteria. As a test case, we used this method to identify epitopes in the proteome of Francisella tularensis (Ft), a Select Agent with a well-characterized immunoproteome. Our screen identified many peptides that map to known antigens, including verified and predicted outer membrane proteins and extracellular proteins, validating the utility of this approach. We then used the method to identify seroreactive peptides in the less characterized immunoproteome of Select Agent Burkholderia pseudomallei (Bp). This screen revealed known Bp antigens as well as proteins that have not been previously identified as antigens. Although B-cell epitope prediction tools Bepipred 2.0 and iBCE-EL classified many of our seroreactive peptides as epitopes, they did not score them significantly higher than the non-reactive tryptic peptides in our study, nor did they assign higher scores to seroreactive peptides from known Ft or Bp antigens, highlighting the need for experimental data instead of relying on computational epitope predictions alone. The present workflow is easily adaptable to detecting peptide targets relevant to the immune systems of other mammalian species, including humans (depending upon the availability of convalescent sera from patients), and could aid in accelerating the discovery of B-cell epitopes and development of vaccines to counter emerging biological threats.

60 APPLIED LIFE SCIENCES↗

Pathfinder Networks for Measuring Operator Mental Model Structure with a Simple Autopilot System

Pathfinder networks are a method to represent mental models from empirically generated pairwise relatedness ratings. This study examined the effects of training exposure on mental model structures based on relatedness ratings collected using the Target Rating method. Forty-eight participants read instruction slides with or without explicit information on the functionality of an autopilot system (Advanced Mental Model or Basic Mental Model groups, respectively). Participants provided relatedness ratings and completed a comprehension test. The Advanced Mental Model group had more common links with the expected model, higher within-group network similarity scores, and higher mental model assessment questionnaire scores than the Basic Mental Model group. Both groups had coherence scores above the minimum threshold for internal consistency. Pathfinder network analysis was sensitive to changes produced by a simple exposure training intervention. In practice, a simple training program may effectively influence operator mental models in novel technological environments such as Advanced Air Mobility.

Mental Models↗

Accelerating detector simulations with Celeritas: profiling and performance optimizations

Celeritas is a GPU-optimized MC particle transport code designed to meet the growing computational demands of next-generation HEP experiments. It provides efficient simulation of EM physics processes in complex geometries with magnetic fields, detector hit scoring, and seamless integration into Geant4-driven applications to offload EM physics to GPUs. Recent efforts have focused on performance optimizations and expanding profiling capabilities. This paper presents some key advancements, including the integration of the Perfetto system profiling tool for detailed performance analysis and the development of track-sorting methods to improve computational efficiency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Machine-learning Solution for Automatic Spacesuit Motion Recognition and Measurement from Conventional Video

Extravehicular Activity (EVA) spacesuits exhibit unique movement patterns due to their design characteristics. Mobility assessments using traditional motion capture systems are cost prohibitive and not feasible for some training conditions (e.g., simulated lunar outdoor terrain). This paper aims to present the ongoing development of machine learning solutions to quantify suit motions from conventional videos without special sensors or hardware. Given the fast growth in deep/machine learning technologies, external expertise was sought from open-source communities. This was expected to accelerate development and provide more cost-effective, time-saving solutions. This work was selected for a NASA Crowdsourcing project through an agency-wide solicitation. Partnerships were formed with the NASA JSC Center of Excellence for Collaborative Innovation and an execution crowdsourcing platform partner to solicit framework developments from external contenders. NASA provided contenders with video clips of spacesuits and simultaneously measured motion capture data during EVA simulation tasks. The contenders used this data to train and develop generalized algorithms to predict motions. At the end of the crowdsourcing event, five solutions were selected from 250 submissions. Each submission was tested and scored using video clips not previously disclosed to the contenders. The scoring metrics measured how well the algorithm detected the suit shape, the 2D suit joint detection accuracy, and 3D joint detection accuracy. The winning solution was able to achieve roughly 85% prediction accuracy (weighted combination of scoring metrics). Overall, the algorithms could efficiently detect various types of spacesuits and motions across different EVA simulation environments such as the Neutral Buoyancy Lab (NBL). However, 3D joint identification is less reliable when parts of the suit were obstructed in the image. After continued improvements and validation, the fully developed system will enable EVA stakeholders to quantify suit kinematic patterns, which can help optimize suit, hardware, and task designs.

Linh Vu↗

Objective Structured Clinical Evaluation (OSCE) of an Artificial Intelligence (AI) Clinical Decision Support System (CDSS) Tool

BACKGROUND Objective Structured Clinical Evaluations (OSCEs) have long been established as a robust methodology for summative assessment of clinical skills and decision-making during medical education. The recent integration of Artificial Intelligence (AI) into clinical decision-making processes has prompted the need for novel evaluation frameworks to assess the efficacy and reliability of AI clinical decision support system (CDSS) tools. This abstract outlines the process of quantitatively evaluating a novel CDSS (“Doc in a Box” Google 2024) trained on curated medical spaceflight data in the psychomotor domain as it interfaces with a human volunteer acting as the crew medical officer (CMO). PURPOSE The AI CDSS under review was developed as part of the Lunar Command and Control Interoperability (LuCCI) project, which is intended to address a gap in how Lunar Surface Systems (LSS) would interoperate across multiple programs, commercial partners, and international partners. The project objective is to define, prototype, integrate, and evaluate an interoperable lunar command, control, data, and software reference architecture to enable autonomy and informatics capability through common standards across LSS. A multi-modal AI-based CDSS compatible with Federated LSS will assist clinicians in diagnosing and managing complex medical conditions by providing evidence-based recommendations through predictive analytics. Given the critical role of decision-support as NASA continues to evolve its Earth-independent medical operations (EIMO), it is imperative to ensure that such AI tools perform reliably and align with clinical standards during progressive lunar and Martian exploration class missions. METHODS The OSCE framework, traditionally used for evaluating human clinicians, was adapted to assess the AI tool's decision-making capabilities in simulated clinical scenarios. In this adapted OSCE, the AI CDSS was tested across a series of structured clinical scenarios designed to mimic real-life spaceflight patient cases. These scenarios included a range of conditions and complexities, allowing for comprehensive assessment of the tool's performance. Key evaluation metrics included accuracy of diagnosis, timeliness of decision-making, and appropriate recommendations for therapies. The OSCE was scored by human physician evaluators who assessed the AI's recommendations in comparison with expert clinicians' medical decision making to ensure alignment with best practices and the standard of care. RESULTS Preliminary results indicate that the AI CDSS demonstrated high accuracy in diagnostic recommendations and decision support across various scenarios. However, certain limitations were noted, such as occasional discrepancies in handling complex or nuanced cases that required a more contextual understanding. Additionally, the tool scored higher on the diagnostic portion of the rubric, with lower scores in the therapeutic recommendations. These findings highlight the importance of continuous refinement and validation of AI tools through rigorous evaluation frameworks like the OSCE. The adaptation of OSCEs for AI tools presents several advantages, including a structured and reproducible approach to evaluation, the ability to test AI systems in diverse clinical scenarios, and the opportunity to benchmark AI performance against established clinical standards to permit charting of future progress as aerospace medicine evolves as a discipline. Remaining challenges include ensuring that these evaluations capture the full spectrum of clinical decision-making scenarios that will be confronted by CMOs during missions and adequately reflecting real-world variability of the austere spaceflight environment. CONCLUSION Employing OSCEs to evaluate AI clinical decision support tools offers a promising approach to validating their clinical utility and efficacy. This methodology not only provides insights into the tool's performance but also fosters ongoing improvement and alignment with standard of care practices. Future research should focus on refining these evaluation processes and addressing limitations to enhance the integration of AI tools in clinical spaceflight settings. REFERENCES Scott S, Hearns V, Barker MA. Testing Clinical Skills: A Look at the OSCE and USMLE Clinical Skills Exams. S D Med. 2019 Oct;72(10):451-453. Majumder MAA, Kumar A, Krishnamurthy K, Ojeh N, Adams OP, Sa B. An evaluative study of objective structured clinical examination (OSCE): students and examiners perspectives. Adv Med Educ Pract. 2019 Jun 5;10:387-397. Karam VY, Park YS, Tekian A, Youssef N. Evaluating the validity evidence of an OSCE: results from a new medical school. BMC Med Educ. 2018 Dec 20;18(1):313.

Ariana M Nelson↗

Identifying schools at high-risk for elevated lead in drinking water using only publicly available data

Estimating the risk of lead contamination of schools' drinking water at the State level is a complex, important, and unexplored challenge. Variable water quality among water systems and changes in water chemistry during distribution affect lead dissolution rates from pipes and fittings. In addition, the locations of lead-bearing plumbing materials are uncertain. We tested the capability of six machine learning models to predict the likelihood of lead contamination of drinking water at the schools' taps using only publicly available datasets. The predictive features used in the models correspond to those with a proven correlation to the dominant, but commonly unavailable, factors that govern lead leaching: the presence of lead-bearing plumbing materials and water quality conducive to lead corrosion. By combining water chemistry data from public reports, socioeconomic information from the US census, and spatial features using Geographic Information Systems, we trained and tested models to estimate the likelihood of lead contaminated tap water in over 8,000 schools across California and Massachusetts. Our best-performing model was a Random Forest, with a 10-fold cross validation score of 0.88 for Massachusetts and 0.78 for California using the average Area Under the Receiver Operating Characteristic Curve (ROC AUC) metric. The model was then used to assign a lead leaching risk category to half of the schools across California (the other half was used for training). There was good agreement between the modeled risk categories and the actual lead leaching outcomes for every school; however, the model overestimated the lead leaching risk in up to 17% of the schools. This model is the first of its kind to offer a tool to predict the risk of lead leaching in schools at the State level. Further use of this model can help deploy limited resources more effectively to prevent childhood lead exposure from school drinking water.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

A meta-learning based distribution system load forecasting model selection framework

This paper presents a meta-learning based, automatic distribution system load forecasting model selection framework. Furthermore, the framework includes the following processes: feature extraction, candidate model preparation and labeling, offline training, and online model recommendation. Using load forecasting needs and data characteristics as input features, multiple metalearners are used to rank the candidate load forecast models based on their forecasting accuracy. Then, a scoring-voting mechanism is proposed to weights recommendations from each meta-leaner and make the final recommendations. Heterogeneous load forecasting tasks with different temporal and technical requirements at different load aggregation levels are set up to train, validate, and test the performance of the proposed framework. Simulation results demonstrate that the performance of the meta-learning based approach is satisfactory in both seen and unseen forecasting tasks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Assessing the Added Value of Miniature X-Ray in the Setting of Portable Ultrasound in Spaceflight

INTRODUCTION: Point-of-care ultrasound (POCUS) has become the standard of care for imaging diagnosis and management in low-Earth Orbit (LEO) spaceflight and it has long been hypothesized that POCUS will also be the standard of care for exploration spaceflight. However, like the trajectory for which ultrasound became more portable and user-friendly, the mass, volume, and power requirements of radiography devices for both diagnostic and therapeutic applications have also been dramatically reduced. This study seeks to determine the clinical utility and added value of miniature x-ray (XR) for the diagnosis and management of each of the 119 conditions within NASA Exploration Medical Capability’s IMPACT Condition List (ICL) given that the medical system is presumed to already be carrying a handheld portable POCUS device. METHODS: For each condition, a team of reviewers performed a rapid systematic literature review seeking sensitivity and specificity data for both handheld portable ultrasound and miniature XR. When there was a paucity of data, subject matter expertise and clinical experience was added to semi-quantitatively score the added value of miniature XR, given an US was already available for both diagnosis and management. Diagnostic utility of a modality for a condition was evaluated in the setting of both the best- and worst-case scenario definitions included and defined by the ICL. Evidence tracing and quality of evidence scores were also recorded. RESULTS/DISCUSSION: Conditions for which it was determined that miniature XR added diagnostic or therapeutic value are provided in this presentation. Previously presented work by our team has demonstrated that XR provides diagnostic and management capabilities that are hypothesized to complement or surpass ultrasound for over one-third of medical conditions that may arise during exploration spaceflight (i.e., diagnosis of injuries to the axial skeleton, teeth, and lungs as well as management of orthopedic reductions, endotracheal tube placement, and drain placement confirmation). In the setting of known inclusion of a handheld portable POCUS device, there remains significant added value of portable miniature XR. Whether or not this added clinical benefit is worth the mass, volume, and power requirements of the radiography system remains yet unknown and is the focus of future work. LEARNING OBJECTIVES: 1) Understand the value of ultrasound and radiography in the diagnosis and management of medical comorbidities that may arise in exploration spaceflight; 2) Understand the medical conditions of highest concern on exploration class missions for which miniature x-ray may provide added value to portable ultrasound.

J G Steller↗