Search NASA⌕ Search

SEARCH · Search NASA

Results for “segmentation averaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Semiautomatic segmentation of liver metastases on volumetric CT images

Purpose: Accurate segmentation and quantification of liver metastases on CT images are critical to surgery/radiation treatment planning and therapy response assessment. To date, there are no reliable methods to perform such segmentation automatically. In this work, the authors present a method for semiautomatic delineation of liver metastases on contrast-enhanced volumetric CT images. Methods: The first step is to manually place a seed region-of-interest (ROI) in the lesion on an image. This ROI will (1) serve as an internal marker and (2) assist in automatically identifying an external marker. With these two markers, lesion contour on the image can be accurately delineated using traditional watershed transformation. Density information will then be extracted from the segmented 2D lesion and help determine the 3D connected object that is a candidate of the lesion volume. The authors have developed a robust strategy to automatically determine internal and external markers for marker-controlled watershed segmentation. By manually placing a seed region-of-interest in the lesion to be delineated on a reference image, the method can automatically determine dual threshold values to approximately separate the lesion from its surrounding structures and refine the thresholds from the segmented lesion for the accurate segmentation of the lesion volume. This method was applied to 69 liver metastases (1.1–10.3 cm in diameter) from a total of 15 patients. An independent radiologist manually delineated all lesions and the resultant lesion volumes served as the “gold standard” for validation of the method’s accuracy. Results: The algorithm received a median overlap, overestimation ratio, and underestimation ratio of 82.3%, 6.0%, and 11.5%, respectively, and a median average boundary distance of 1.2 mm. Conclusions: Preliminary results have shown that volumes of liver metastases on contrast-enhanced CT images can be accurately estimated by a semiautomatic segmentation method.

60 APPLIED LIFE SCIENCES↗

Radiation doses in cone-beam breast computed tomography: A Monte Carlo simulation study

Purpose: In this article, we describe a method to estimate the spatial dose variation, average dose and mean glandular dose (MGD) for a real breast using Monte Carlo simulation based on cone beam breast computed tomography (CBBCT) images. We present and discuss the dose estimation results for 19 mastectomy breast specimens, 4 homogeneous breast models, 6 ellipsoidal phantoms, and 6 cylindrical phantoms. Methods: To validate the Monte Carlo method for dose estimation in CBBCT, we compared the Monte Carlo dose estimates with the thermoluminescent dosimeter measurements at various radial positions in two polycarbonate cylinders (11- and 15-cm in diameter). Cone-beam computed tomography (CBCT) images of 19 mastectomy breast specimens, obtained with a bench-top experimental scanner, were segmented and used to construct 19 structured breast models. Monte Carlo simulation of CBBCT with these models was performed and used to estimate the point doses, average doses, and mean glandular doses for unit open air exposure at the iso-center. Mass based glandularity values were computed and used to investigate their effects on the average doses as well as the mean glandular doses. Average doses for 4 homogeneous breast models were estimated and compared to those of the corresponding structured breast models to investigate the effect of tissue structures. Average doses for ellipsoidal and cylindrical digital phantoms of identical diameter and height were also estimated for various glandularity values and compared with those for the structured breast models. Results: The absorbed dose maps for structured breast models show that doses in the glandular tissue were higher than those in the nearby adipose tissue. Estimated average doses for the homogeneous breast models were almost identical to those for the structured breast models (p=1). Normalized average doses estimated for the ellipsoidal phantoms were similar to those for the structured breast models (root mean square (rms) percentage difference=1.7%; p=0.01), whereas those for the cylindrical phantoms were significantly lower (rms percentage difference=7.7%; p<0.01). Normalized MGDs were found to decrease with increasing glandularity. Conclusions: Our results indicate that it is sufficient to use homogeneous breast models derived from CBCT generated structured breast models to estimate the average dose. This investigation also shows that ellipsoidal digital phantoms of similar dimensions (diameter and height) and glandularity to actual breasts may be used to represent a real breast to estimate the average breast dose with Monte Carlo simulation. We have also successfully demonstrated the use of structured breast models to estimate the true MGDs and shown that the normalized MGDs decreased with the glandularity as previously reported by other researchers for CBBCT or mammography.

60 APPLIED LIFE SCIENCES↗

Analyzing the post-contrast attenuation of the esophageal wall on routine contrast-enhanced MDCT examination can improve the diagnostic accuracy in response evaluation of the squamous cell esophageal carcinoma to neoadjuvant chemoradiotherapy in comparison with the esophageal wall thickness

Purpose: To evaluate the accuracy of the multidetector computed tomography (MDCT) in the response evaluation of the esophageal squamous cell carcinoma (ESCC) to neoadjuvant chemoradiotherapy (nCRT) by analyzing the thickness and post-contrast attenuation of the esophageal wall after the nCRT. Methods: Contrast-enhanced (CE)-MDCT examinations in portal venous phase of one hundred patients with locally advanced ESCC who received nCRT and underwent esophageal resection and histopathology assessment of tumor regression grade (TRG) were retrospectively analyzed by measuring the maximal thickness and mean density of the esophageal wall in the segment involved by tumor and visually searching for hyperdense foci within it. Diagnostic performance was evaluated using the ROC analysis. Results: Average attenuation of the esophageal wall had stronger diagnostic performance for predicting pathologic complete regression (pCR) (AUC = 0.994; p < 0.001) in relation to maximal esophageal wall thickness (AUC = 0.731; p < 0.001). Maximal esophageal wall thickness ≤ 9 mm and average attenuation of the esophageal wall ≤ 64 HU predicted pCR with the sensitivity, specificity, and overall accuracy of 62.5%, 77.9%, and 73%, and 96.9%, 98.5%, and 98%, respectively. Combination of both cutoff values enabled correct assessment of pCR with the 100% accuracy. Visual detection of the hyperdense focus within the esophageal wall predicted pCR with the sensitivity, specificity, and overall accuracy values of 100%, 94.1%, and 96%, respectively. Conclusion: Visual analysis and measurement of post-contrast attenuation of the esophageal wall after the nCRT can improve diagnostic accuracy of MDCT in the response evaluation of the ESCC to nCRT in comparison with measuring the esophageal wall thickness.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Automatic Identification and Truncation of Boundary Outlets in Complex Imaging-Derived Biomedical Geometries

Fast and accurate reconstruction of imaging-derived geometries and subsequent quality mesh generation for biomedical computation are enabling technologies for both clinical and research simulations. Often, the transformation of image to mesh is the rate-limiting step, requiring arduous manual manipulations. A challenging part of this process is the introduction of computable, orthogonal boundary patches, namely the outlets, into treed structures, such as vasculature, arterial or airway trees. Herein, we present efficient and robust algorithms for automatically identifying and truncating the outlets for complex biomedical geometries. Our approach is based on a conceptual decomposition of objects into three different types of local structures, including tips, segments, and branches, where the tips determine the outlets. We define the tips by introducing a novel geometric concept called the average interior center of curvature (AICC), and identify those that are physically stable and numerically noise resistant through successive inflation and deflation tests. We compute well-defined orthogonal planes, which truncate the tips into outlets. The rims of the outlets are then connected into curves, and the outlets are then closed using Delaunay triangulation with the curves as the boundary constraints. Our approach is efficient, with near linear time complexity. We illustrate the effectiveness and robustness of our approach with a variety of complex lung and coronary artery geometries.

60 APPLIED LIFE SCIENCES↗

Measurement of Muon Antineutrino Quasielastic Scattering on a Hydrocarbon Target at E ν ~3.5 GeV

We have isolated ν¯ μ charged-current quasielastic (QE) interactions occurring in the segmented scintillator tracking region of the MINERvA detector running in the NuMI neutrino beam at Fermilab. We measure the flux-averaged differential cross section, dσ/dQ², and compare to several theoretical models of QE scattering. Good agreement is obtained with a model where the nucleon axial mass, M A , is set to 0.99 GeV/c² but the nucleon vector form factors are modified to account for the observed enhancement, relative to the free nucleon case, of the cross section for the exchange of transversely polarized photons in electron-nucleus scattering. Our data at higher Q² favor this interpretation over an alternative in which the axial mass is increased.

Fields, L.↗

SU-F-J-220: Micro-CT Based Quantification of Mouse Brain Vasculature: The Effects of Acquisition Technique and Contrast Material

Purpose: Cognitive impairment from radiation therapy to the brain may be linked to the loss of total blood volume in the brain. To account for brain injury, it is crucial to develop an understanding of blood volume loss as a result of radiation therapy. This study investigates µCT based quantification of mouse brain vasculature, focusing on the effect of acquisition technique and contrast material. Methods: Four mice were scanned on a µCT scanner (Siemens Inveon). The reconstructed voxel size was 18µm3 and all protocols were Hounsfield Unit (HU) calibrated. The mice were injected with 40mg of gold nanoparticles (MediLumine) or 100µl of Exitron 12000 (Miltenyi Biotec). Two acquisition techniques were also performed. A single kVp technique scanned the mouse once using an x-ray beam of 80kVp and segmentation was completed based on a threshold of HU values. The dual kVp technique scanned the mouse twice using 50kVp and 80kVp, this segmentation was based on the ratio of the HU value of the two kVps. After image reconstruction and segmentation, the brain blood volume was determined as a percentage of the total brain volume. Results: For the single kVp acquisition at 80kVp, the brain blood volume had an average of 3.5% for gold and 4.0% for Exitron 12000. Also at 80kVp, the contrast-noise ratio was significantly better for images acquired with the gold nanoparticles (2.0) than for those acquired with the Exitron 12000 (1.4). The dual kVp acquisition shows improved separation of skull from vasculature, but increased image noise. Conclusion: In summary, the effects of acquisition technique and contrast material for quantification of mouse brain vasculature showed that gold nanoparticles produced more consistent segmentation of brain vasculature than Exitron 12000. Also, dual kVp acquisition may improve the accuracy of brain vasculature quantification, although the effect of noise amplification warrants further study.

60 APPLIED LIFE SCIENCES↗

Toward accurate tooth segmentation from computed tomography images using a hybrid level set model

Purpose: A three-dimensional (3D) model of the teeth provides important information for orthodontic diagnosis and treatment planning. Tooth segmentation is an essential step in generating the 3D digital model from computed tomography (CT) images. The aim of this study is to develop an accurate and efficient tooth segmentation method from CT images. Methods: The 3D dental CT volumetric images are segmented slice by slice in a two-dimensional (2D) transverse plane. The 2D segmentation is composed of a manual initialization step and an automatic slice by slice segmentation step. In the manual initialization step, the user manually picks a starting slice and selects a seed point for each tooth in this slice. In the automatic slice segmentation step, a developed hybrid level set model is applied to segment tooth contours from each slice. Tooth contour propagation strategy is employed to initialize the level set function automatically. Cone beam CT (CBCT) images of two subjects were used to tune the parameters. Images of 16 additional subjects were used to validate the performance of the method. Volume overlap metrics and surface distance metrics were adopted to assess the segmentation accuracy quantitatively. The volume overlap metrics were volume difference (VD, mm{sup 3}) and Dice similarity coefficient (DSC, %). The surface distance metrics were average symmetric surface distance (ASSD, mm), RMS (root mean square) symmetric surface distance (RMSSSD, mm), and maximum symmetric surface distance (MSSD, mm). Computation time was recorded to assess the efficiency. The performance of the proposed method has been compared with two state-of-the-art methods. Results: For the tested CBCT images, the VD, DSC, ASSD, RMSSSD, and MSSD for the incisor were 38.16 ± 12.94 mm{sup 3}, 88.82 ± 2.14%, 0.29 ± 0.03 mm, 0.32 ± 0.08 mm, and 1.25 ± 0.58 mm, respectively; the VD, DSC, ASSD, RMSSSD, and MSSD for the canine were 49.12 ± 9.33 mm{sup 3}, 91.57 ± 0.82%, 0.27 ± 0.02 mm, 0.28 ± 0.03 mm, and 1.06 ± 0.40 mm, respectively; the VD, DSC, ASSD, RMSSSD, and MSSD for the premolar were 37.95 ± 10.13 mm{sup 3}, 92.45 ± 2.29%, 0.29 ± 0.06 mm, 0.33 ± 0.10 mm, and 1.28 ± 0.72 mm, respectively; the VD, DSC, ASSD, RMSSSD, and MSSD for the molar were 52.38 ± 17.27 mm{sup 3}, 94.12 ± 1.38%, 0.30 ± 0.08 mm, 0.35 ± 0.17 mm, and 1.52 ± 0.75 mm, respectively. The computation time of the proposed method for segmenting CBCT images of one subject was 7.25 ± 0.73 min. Compared with two other methods, the proposed method achieves significant improvement in terms of accuracy. Conclusions: The presented tooth segmentation method can be used to segment tooth contours from CT images accurately and efficiently.

60 APPLIED LIFE SCIENCES↗

SU-E-T-478: Sliding Window Multi-Criteria IMRT Optimization

Purpose: To demonstrate a method for what-you-see-is-what-you-get multi-criteria Pareto surface navigation for step and shoot IMRT treatment planning. Methods: We show mathematically how multiple sliding window treatment plans can be averaged to yield a single plan whose dose distribution is the dosimetric average of the averaged plans. This is incorporated into the Pareto surface navigation based approach to treatment planning in such a way that as the user navigates the surface, the plans he/she is viewing are ready to be delivered (i.e. there is no extra ‘segment the plans’ step that often leads to unacceptable plan degradation in step and shoot Pareto surface navigation). We also describe how the technique can be applied to VMAT. Briefly, sliding window VMAT plans are created such that MLC leaves paint out fluence maps every 15 degrees or so. These fluence map leaf trajectories are averaged in the same way the static beam IMRT ones are. Results: We show mathematically that fluence maps are exactly averaged using our leaf sweep averaging algorithm. Leaf transmission and output factor corrections effects, which are ignored in this work, can lead to small errors in terms of the dose distributions not being exactly averaged even though the fluence maps are. However, our demonstrations show that the dose distributions are almost exactly averaged as well. We demonstrate the technique both for IMRT and VMAT. Conclusions: By turning to sliding window delivery, we show that the problem of losing plan fidelity during the conversion of an idealized fluence map plan into a deliverable plan is remedied. This will allow for multicriteria optimization that avoids the pitfall that the planning has to be redone after the conversion into MLC segments due to plan quality decline. David Craft partially funded by RaySearch Laboratories.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Multiphase Validation of Atlas-Based Automatic and Semiautomatic Segmentation Strategies for Prostate MRI

Purpose: To perform a rigorous technological assessment and statistical validation of a software technology for anatomic delineations of the prostate on MRI datasets. Methods and Materials: A 3-phase validation strategy was used. Phase I consisted of anatomic atlas building using 100 prostate cancer MRI data sets to provide training data sets for the segmentation algorithms. In phase II, 2 experts contoured 15 new MRI prostate cancer cases using 3 approaches (manual, N points, and region of interest). In phase III, 5 new physicians with variable MRI prostate contouring experience segmented the same 15 phase II datasets using 3 approaches: manual, N points with no editing, and full autosegmentation with user editing allowed. Statistical analyses for time and accuracy (using Dice similarity coefficient) endpoints used traditional descriptive statistics, analysis of variance, analysis of covariance, and pooled Student t test. Results: In phase I, average (SD) total and per slice contouring time for the 2 physicians was 228 (75), 17 (3.5), 209 (65), and 15 seconds (3.9), respectively. In phase II, statistically significant differences in physician contouring time were observed based on physician, type of contouring, and case sequence. The N points strategy resulted in superior segmentation accuracy when initial autosegmented contours were compared with final contours. In phase III, statistically significant differences in contouring time were observed based on physician, type of contouring, and case sequence again. The average relative timesaving for N points and autosegmentation were 49% and 27%, respectively, compared with manual contouring. The N points and autosegmentation strategies resulted in average Dice values of 0.89 and 0.88, respectively. Pre- and postedited autosegmented contours demonstrated a higher average Dice similarity coefficient of 0.94. Conclusion: The software provided robust contours with minimal editing required. Observed time savings were seen for all physicians irrespective of experience level and baseline manual contouring speed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

RFM-based eco-efficiency analysis using Takagi-Sugeno fuzzy and AHP approach

Eco-design is crucial to take environmental aspects into account in the phases of design. Few literature review that green product must meet market value. The development of models to predict market value is thus very useful because it can provide early eco-efficiency to the eco-design. For the eco-design engineer, when he tries to solve a customer feedback problem, he usually faces the eco-efficiency. There are, however, often other types of fuzziness uncertainty present, which are related to the quantity of eco-design conditions. In this paper, it is derived that analysis of eco-efficiency can be identified by using the RFM value for quantifying eco-design with Takagi-Sugeno fuzzy system on customer feedback problem. It clusters eco-efficiency into segments according to green product usages value expressed in terms of weighted RFM. This experiment examined the weighted RFM effect of overall average normalized, AHP and non-weighted for F1 metric. The experimental results show that the proposed methodology indeed can yield identification of higher quality.

54 ENVIRONMENTAL SCIENCES↗

Noise power spectral density of a fibre scattered-light interferometer with a semiconductor laser source

Spectral characteristics of the noise intensity fluctuations at the output of a scattered-light interferometer, caused by phase fluctuations of semiconductor laser radiation are considered. This kind of noise is one of the main factors limiting sensitivity of interferometric sensors. For the first time, to our knowledge, the expression is obtained for the average noise power spectral density at the interferometer output versus the degree of a light source coherence and length of the scattering segment. Also, the approximate expressions are considered which determine the power spectral density in the low-frequency range (up to 200 kHz) and in the limiting case of extended scattering segments. The expression obtained for the noise power spectral density agrees with experimental normalised power spectra with a high accuracy. (interferometry of radiation)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-C-12A-05: Radiation Dose in High-Pitch Pediatric Cardiac CTA: Correlation Between Lung Dose and CTDIvol, DLP, and Size Specific Dose Estimates (SSDE)

Purpose: To investigate the radiation dose for pediatric high pitch cardiac CTA Methods: A total of 14 cases were included in this study, with mean age of 6.2 years (ranges from 2 months to 15 years). Cardiac CTA was performed using a dual-source CT system (Definition Flash, Siemens). Tube voltage (70, 80 and 100kV) was chosen based on patient weight. All patients were scanned using a high-pitch spiral mode (pitch ranges from 2.5 to 3) with tube current modulation technique (CareDose4D, Siemens). For each case, the three dimensional dose distributions were calculated using a Monte Carlo software package (IMPACT-MC, CT Image GmbH). Scanning parameters of each exam, including tube voltage, tube current, beamshaping filters, beam collimation, were defined in the Monte Carlo calculation. Tube current profile along projection angles was obtained from projection data of each tube, which included data within the over-scanning range along z direction. The volume of lungs was segmented out with CT images (3DSlicer). Lung doses of all patients were calculated and compared with CTDIvol, DLP, and SSDE. Results: The average (range) of CTDIvol, DLP and SSDE of all patients was 1.19 mGy (0.58 to 3.12mGy), 31.54 mGy*cm (12.56 to 99 mGy*cm), 2.26 mGy (1.19 to 6.24 mGy), respectively. Radiation dose to the lungs ranged from 0.83 to 4.18 mGy. Lung doses correlated with CTDIvol, DLP and SSDE with correlation coefficients(k) at 0.98, 0.93, and 0.99. However, for the cases with CTDIvol less than 1mGy, only SSDE preserved a strong correlation with lung doses (k=0.83), while much weaker correlations were found for CTDIvol (k=0.29) and DLP (k=-0.47). Conclusion: Lung doses to pediatric patients during Cardiac CTA were estimated. SSDE showed the most robust correlation with lung doses in contrast to CTDIvol and DLP.

60 APPLIED LIFE SCIENCES↗

Centriole and transition zone structures in photoreceptor cilia revealed by cryo-electron tomography

Primary cilia mediate sensory signaling in multiple organisms and cell types but have structures adapted for specific roles. Structural defects in them lead to devastating diseases known as ciliopathies in humans. Key to their functions are structures at their base: the basal body, the transition zone, the “Y-shaped links,” and the “ciliary necklace.” We have used cryo-electron tomography with subtomogram averaging and conventional transmission electron microscopy to elucidate the structures associated with the basal region of the “connecting cilia” of rod outer segments in mouse retina. The longitudinal variations in microtubule (MT) structures and the lumenal scaffold complexes connecting them have been determined, as well as membrane-associated transition zone structures: Y-shaped links connecting MT to the membrane, and ciliary beads connected to them that protrude from the cell surface and form a necklace-like structure. These results represent a clearer structural scaffold onto which molecules identified by genetics, proteomics, and superresolution fluorescence can be placed in our emerging model of photoreceptor sensory cilia.

59 BASIC BIOLOGICAL SCIENCES↗

Optical Modeling Activities for the James Webb Space Telescope (JWST) Project: Determining Image Motion and Wavefront Error Over an Extended Field of View with a Segmented Optical System - II

This is part two of a series on the optical modeling activities for JWST. Starting with the linear optical model discussed in part one, we develop centroid and wavefront error sensitivities for the special case of a segmented optical system such as JWST, where the primary mirror consists of 18 individual segments. Our approach extends standard sensitivity matrix methods used for systems consisting of monolithic optics, where the image motion is approximated by averaging ray coordinates at the image and residual wavefront error is determined with global tip/tilt removed. We develop an exact formulation using the linear optical model, and extend it to cover multiple field points for performance prediction at each instrument aboard JWST. This optical model is then driven by thermal and dynamic structural perturbations in an integrated modeling environment. Results are presented.

Howard, Joseph M.↗

Magnetospheric Multiscale Instrument Suite Operations and Data System

The four Magnetospheric Multiscale (MMS) spacecraft will collect a combined volume of approximately 100 gigabits per day of particle and field data. On average, only 4 gigabits of that volume can be transmitted to the ground. To maximize the scientific value of each transmitted data segment, MMS has developed the Science Operations Center (SOC) to manage science operations, instrument operations, and selection, downlink, distribution, and archiving of MMS science data sets. The SOC is managed by the Laboratory for Atmospheric and Space Physics (LASP) in Boulder, Colorado and serves as the primary point of contact for community participation in the mission. MMS instrument teams conduct their operations through the SOC, and utilize the SOC's Science Data Center (SOC) for data management and distribution. The SOC provides a single mission data archive for the housekeeping and science data, calibration data, ephemerides, attitude and other ancillary data needed to support the scientific use and interpretation. All levels of data products will reside at and be publicly disseminated from the SDC. Documentation and metadata describing data products, algorithms, instrument calibrations, validation, and data quality will be provided. Arguably, the most important innovation developed by the SOC is the MMS burst data management and selection system. With nested automation and 'Scientist-in-the-Loop' (SITL) processes, these systems are designed to maximize the value of the burst data by prioritizing the data segments selected for transmission to the ground. This paper describes the MMS science operations approach, processes and data systems, including the burst system and the SITL concept.

Baker, D. N.↗

Three-dimensional quadratic modeling and quantitative evaluation of the diaphragm on a volumetric CT scan in patients with chronic obstructive pulmonary disease

Purpose: In patients with chronic obstructive pulmonary disease (COPD), diaphragm function may deteriorate due to reduced muscle fiber length. Quantitative analysis of the morphology of the diaphragm is therefore important. In the authors current study, they propose a diaphragm segmentation method for COPD patients that uses volumetric chest computed tomography (CT) data, and they provide a quantitative analysis of the diaphragmatic dimensions. Methods: Volumetric CT data were obtained from 30 COPD patients and 10 normal control patients using a 16-row multidetector CT scanner (Siemens Sensation 16) with 0.75-mm collimation. Diaphragm segmentation using 3D ray projections on the lower surface of the lungs was performed to identify the draft diaphragmatic lung surface, which was modeled using quadratic 3D surface fitting and robust regression in order to minimize the effects of segmentation error and parameterize diaphragm morphology. This result was visually evaluated by an expert thoracic radiologist. To take into consideration the shape features of the diaphragm, several quantification parameters—including the shape index on the apex (SIA) (which was computed using gradient set to 0), principal curvatures on the apex on the fitted diaphragm surface (CA), the height between the apex and the base plane (H), the diaphragm lengths along the x-, y-, and z-axes (XL, YL, ZL), quadratic-fitted diaphragm lengths on the z-axis (FZL), average curvature (C), and surface area (SA)—were measured using in-house software and compared with the pulmonary function test (PFT) results. Results: The overall accuracy of the combined segmentation method was 97.22% ± 4.44% while the visual accuracy of the models for the segmented diaphragms was 95.28% ± 2.52% (mean ± SD). The quantitative parameters, including SIA, CA, H, XL, YL, ZL, FZL, C, and SA were 0.85 ± 0.05 (mm{sup −1}), 0.01 ± 0.00 (mm{sup −1}), 17.93 ± 10.78 (mm), 129.80 ± 11.66 (mm), 163.19 ± 13.45 (mm), 71.27 ± 17.52 (mm), 61.59 ± 16.98 (mm), 0.01 ± 0.00 (mm{sup −1}), and 34 380.75 ± 6680.06 (mm{sup 2}), respectively. Several parameters were correlated with the PFT parameters. Conclusions: The authors propose an automatic method for quantitatively evaluating the morphological parameters of the diaphragm on volumetric chest CT in COPD patients. By measuring not only the conventional length and surface area but also the shape features of the diaphragm using quadratic 3D surface modeling, the proposed method is especially useful for quantifying diaphragm characteristics. Their method may be useful for assessing morphological diaphragmatic changes in COPD patients.

60 APPLIED LIFE SCIENCES↗

SU-E-T-134: Dosimetric Implications From Organ Segmentation

Purpose: To evaluate the dosimetric implications resulting from organ segmentation performed by different clinical experts Methods: Twelve patients received SBRT treatment to thoracic region within the past year were selected for this study. Three physicians contoured a set of organs following RTOG guideline. DVHs of all contours were generated from the approved plans used for treatment, and were compared to those produced during planning. Most OARs were evaluated on their max dose, some, such as heart and chest wall, were also evaluated on metrics such as max dose to 4cc of volume, or 30Gy volume dose. Results: In general, there is a greater dosimetric difference between the RTOG contour sets and clinical contour sets than among the three RTOG contour sets themselves for each patient. For example, there was no difference in esophagus max dose between the RTOG contour sets for ten patients. However, they showed an average of 2.3% higher max dose than the clinical contour set, with a standard deviation of 6.6%. The proximal bronchial tree (PBT) showed a similar behavior. The average difference of PBT max dose for seven patients is 0% between the three RTOG contour sets, with standard deviation of 1%. They showed an average of 16.1% higher max dose than the clinical contour set, with a standard deviation of 126%. Conclusion: This study shows that using RTOG contouring standards improves segmentation consistency between different physicians; most of the contours examined showed less than 1% dose difference. When RTOG contour sets were compared to the clinical contour set, the differences are much more significant. Thus it is important to standardize contouring guidelines in radiation therapy treatment planning. This will reduce uncertainties in clinical outcome analysis and research studies.

60 APPLIED LIFE SCIENCES↗

RIPL - Reference Input Parameter Library for Calculation of Nuclear Reactions and Nuclear Data Evaluations

We describe the physics and data included in the Reference Input Parameter Library, which is devoted to input parameters needed in calculations of nuclear reactions and nuclear data evaluations. Advanced modelling codes require substantial numerical input, therefore the International Atomic Energy Agency (IAEA) has worked extensively since 1993 on a library of validated nuclear-model input parameters, referred to as the Reference Input Parameter Library (RIPL). A final RIPL coordinated research project (RIPL-3) was brought to a successful conclusion in December 2008, after 15 years of challenging work carried out through three consecutive IAEA projects. The RIPL-3 library was released in January 2009, and is available on the Web through (http://www-nds.iaea.org/RIPL-3/). This work and the resulting database are extremely important to theoreticians involved in the development and use of nuclear reaction modelling (ALICE, EMPIRE, GNASH, UNF, TALYS) both for theoretical research and nuclear data evaluations. The numerical data and computer codes included in RIPL-3 are arranged in seven segments: MASSES contains ground-state properties of nuclei for about 9000 nuclei, including three theoretical predictions of masses and the evaluated experimental masses of Audi et al. (2003). DISCRETE LEVELS contains 117 datasets (one for each element) with all known level schemes, electromagnetic and {gamma}-ray decay probabilities available from ENSDF in October 2007. NEUTRON RESONANCES contains average resonance parameters prepared on the basis of the evaluations performed by Ignatyuk and Mughabghab. OPTICAL MODEL contains 495 sets of phenomenological optical model parameters defined in a wide energy range. When there are insufficient experimental data, the evaluator has to resort to either global parameterizations or microscopic approaches. Radial density distributions to be used as input for microscopic calculations are stored in the MASSES segment. LEVEL DENSITIES contains phenomenological parameterizations based on the modified Fermi gas and superfluid models and microscopic calculations which are based on a realistic microscopic single-particle level scheme. Partial level densities formulae are also recommended. All tabulated total level densities are consistent with both the recommended average neutron resonance parameters and discrete levels. GAMMA contains parameters that quantify giant resonances, experimental gamma-ray strength functions and methods for calculating gamma emission in statistical model codes. The experimental GDR parameters are represented by Lorentzian fits to the photo-absorption cross sections for 102 nuclides ranging from {sup 51}V to {sup 239}Pu. FISSION includes global prescriptions for fission barriers and nuclear level densities at fission saddle points based on microscopic HFB calculations constrained by experimental fission cross sections.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗