Search NASA⌕ Search

SEARCH · Search NASA

Results for “selenium”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Assessment of deep levels with selenium concentration in Cd 1–x Zn x Te 1–y Se y room temperature detector materials

Incorporation of Se into Cd 1–x Zn x Te (CZT) to form the quaternary compound semiconductor Cd 1–x Zn x Te 1–y Se y (CZTS) has proven to be an effective solution for compensating the major flaws associated with CZT, including poor homogeneity and high concentrations of electronically active deep levels that limit the performance of CZT detectors. In order to investigate how deep levels are affected by the Se concentration in CZTS, we performed photoinduced current transient spectroscopy (PICTS) measurements on CZTS crystals grown by the traveling heater method (THM) with 10% atomic Zn and varying atomic percentage of Se from 1.5% to 7.0%. The PICTS scans for up to 4% Se showed an exponential reduction in the capture cross section of deep levels associated with Te secondary phases in conjunction with an increase in a deep level positioned near the mid-gap, which initially increases the electron trapping time before degrading again at higher Se concentrations. The PICTS peaks present in 7% Se were anomalous relative to the other crystals and are expected to originate from transition metal impurities found in the lower-purity CdSe precursor material.

36 MATERIALS SCIENCE↗

WE-G-204-04: Focal Spot Deblurring For High Resolution Amorphous Selenium (aSe) Complementary Metal Oxide Semiconductor (CMOS) X-Ray Detector

Purpose: CMOS-based aSe detectors compared to CsI-TFT-based flat panels have the advantages of higher spatial sampling due to smaller pixel size and decreased blurring characteristic of direct rather than indirect detection. For systems with such detectors, the limiting factor degrading image resolution then becomes the focal-spot geometric unsharpness. This effect can seriously limit the use of such detectors in areas such as cone beam computed tomography, clinical fluoroscopy and angiography. In this work a technique to remove the effect of focal-spot blur is presented for a simulated aSe detector. Method: To simulate images from an aSe detector affected with focal-spot blur, first a set of high-resolution images of a stent (FRED from Microvention, Inc.) were acquired using a 75µm pixel size Dexela-Perkin-Elmer detector and averaged to reduce quantum noise. Then the averaged image was blurred with a known Gaussian blur at two different magnifications to simulate an idealized focal spot. The blurred images were then deconvolved with a set of different Gaussian blurs to remove the effect of focal-spot blurring using a threshold-based, inverse-filtering method. Results: The blur was removed by deconvolving the images using a set of Gaussian functions for both magnifications. Selecting the correct function resulted in an image close to the original; however, selection of too wide a function would cause severe artifacts. Conclusion: Experimentally, focal-spot blur at different magnifications can be measured using a pin hole with a high resolution detector. This spread function can be used to deblur the input images that are acquired at corresponding magnifications to correct for the focal spot blur. For CBCT applications, the magnification of specific objects can be obtained using initial reconstructions then corrected for focal-spot blurring to improve resolution. Similarly, if object magnification can be determined such correction may be applied in fluoroscopy and angiography.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enriched Boron-Doped Amorphous Selenium Based Position-Sensitive Solid-State Thermal Neutron Detector for MPACT Applications

High-efficiency thermal neutron detectors with compact size, low power-rating and high spatial, temporal and energy resolution are essential to execute non-proliferation and safeguard protocols. The demands of such detector are not fully covered by the current detection system such as gas proportional counters or scintillator-photomultiplier tube combinations, which are limited by their detection efficiency, stability of response, speed of operation, and physical size. Furthermore, world-wide shortage of 3 He gas, required for widely used gas detection method, has further prompted to design an alternative system. Therefore, a solid-state neutron detection system without the requirement of 3 He will be very desirable. To address the above technology gap, we had proposed to develop new room temperature solidstate thermal neutron detectors based on enriched boron ( 10 B) and enriched lithium ( 6 Li) doped amorphous Se (As- 0.52%, Cl 5 ppm) semiconductor for MPACT applications. The proposed alloy materials have been identified for its many favorable characteristics - a wide bandgap (~2.2 eV at 300 K) for room temperature operation, high glass transition temperature (t g ~ 85°C), a high thermal neutron cross-section (for boron ~ 3840 barns, for lithium ~ 940 barns, 1 barn = 10 -24 cm 2 ), low effective atomic number of Se for small gamma ray sensitivity, and high radiation tolerance due to its amorphous structure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Selenium immersed thermistor bolometer study

The noise characteristics of thermistor bolometers immersed in layers of arsenic/selenium glass uniform in composition were examined. Using a controlled deposition technique, layers of glass were deposited, thermistor bolometers immersed, and their electrical characteristics measured after various thermal treatments. Markedly improved stability of the detector noise was observed using this new technique.

Rolls, W. H.↗

Post-entry and volcanic contaminant abundances of zinc, copper, selenium, germanium and gallium in stratospheric micrometeorites

Some fraction of Zn, Cu, Se, Ga and Ge in chondritic interplanetary dust particles (IDPs) collected in the lower stratosphere between 1981 May and 1984 June has a volcanic origin. I present a method to evaluate the extent of this unavoidable type of stratospheric contamination for individual particles. The mass-normalized abundances for Cu and Ge as a function of mass-normalized stratospheric residence time show their time-integrated stratospheric aerosol abundances. The Zn, Se and Ga abundances show a subdivision into two groups that span approximately two-year periods following the eruptions of the Mount St. Helens (1980 May) and El Chichon (1982 April) volcanoes. Elemental abundances in particles collected at the end of each two-year period indicate low, but not necessarily ambient, volcanic stratospheric abundances. Using this time-integrated baseline, I calculate the straospheric contaminant fractions in nine IDPs and show that Zn, SE and Ga abundances in chondritic IDPs derive in part from stratospheric aerosol contaminants. Post-entry elemental abundances (i.e., the amount that survived atmospheric entry heating of the IDP) show enrichments relative to the CI abundances but in a smaller number of particles than previously suggested.

Rietmeijer, Frans J. M.↗

Segregation Coefficients of Impurities in Selenium by Zone Refining

The purification of Se by zone refining process was studied. The impurity solute levels along the length of a zone-refined Se sample were measured by spark source mass spectrographic analysis. By comparing the experimental concentration levels with theoretical curves the segregation coefficient, defined as the ratio of equilibrium concentration of a given solute in the solid to that in the liquid, k = x(sub s)/x(sub l) for most of the impurities in Se are found to be close to unity, i.e., between 0.85 and 1.15, with the k value for Si, Zn, Fe, Na and Al greater than 1 and that for S, Cl, Ca, P, As, Mn and Cr less than 1. This implies that a large number of passes is needed for the successful implementation of zone refining in the purification of Se.

Su, Ching-Hua↗