Search NASA⌕ Search

SEARCH · Search NASA

Results for “sensitivity methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Diode injection - seeded, 940 nanometer (nm), titanium - sapphire laser for H2O DIAL (differential absorption lidar), measurements

Differential absorption of laser radiation by various molecular species represents both a selective and a sensitive method of measuring specific atmospheric constituents. DIAL measurements can be carried out via two different means. Both involve using two laser pulses with slightly different wavelengths (lambda), (one lambda at a strong absorption line of the molecule of interest, the other detuned into the wing of the line), and comparing the attenuation of the pulses. One approach relies on scattering of the radiation from some conveniently located topographical target. In the other technique elastic scattering from atmospheric aerosols and particulates is used to return the radiation to the lidar receiver system. This case is referred to as the differential absorption and scattering technique, and is the technique we are interested in to measure water vapor at 940 nm. The 940 nm wavelength is extremely desirable to atmospheric scientist interested in accurate DIAL measurements of H2O in the upper and lower troposphere. Simulated measurements using approximately 940 nm and 815 nm lasers at a range of altitudes and experimental conditions are shown. By offering access to larger absorption cross-sections, injected seeded, 940 nm DIAL laser transmitters would allow for more accurate water profile measurements at altitudes from 6 to 16 km than is currently possible with 730 nm and 815 nm DIAL laser transmitters. We have demonstrated the operation of an injected seeded titanium-sapphire (TS) laser operating at approximately 940 nm with an energy of more than 90 mJ per pulse. The TS laser is pumped by a commercial, 600 mJ, 532 nm, 10 Hz Nd:YAG laser. The slope efficiency of the laser using a flat 50 percent R output coupler and a 10 m end-mirror is shown. The laser was injected seeded with a CW, AlGaAs, semiconductor diode laser which had an output of 83 mW. The CW diode seed beam was introduced into the TS laser cavity through a HR end-mirror. When the diode beam is aligned to the TS resonator, it controls the TS laser output wavelength and its spectral line width with the required resolution for DIAL applications. This work supports the need for the development of 940 nm, titanium-sapphire DIAL transmitters.

Miller, George E.↗

On the rms anisotropy at 7 deg and 10 deg observed in the COBE-DMR two year sky maps

The frequency-independent rms temperature fluctuations determined from the Cosmic Background Explorer-Differential Microwave Radiometer (COBE-DMR) two-year sky maps are used to infer the parameter Q(sub rms-PS), which characterizes the normalization of power-law models of primordial cosmological temperature anisotropy, for a forced fit to a scale-invariant Harrison-Zel'dovich (n = 1) spectral model. Using a joint analysis of the 7 deg and 10 deg 'cross'-rms derived from both the 53 and 90 GHz sky maps, we find Q(sub rms-PS) = 17.0(sub -2.1 sup +2.5) micro Kelvin when the low quadrupole is included, and Q(sub rms-PS) = 19.4(sub -2.1 sup +2.3) micro Kelvin excluding the quadrupole. These results are consistent with the n = 1 fits from more sensitive methods. The effect of the low quadrupole derived from the COBE-DMR data on the inferred Q(sub rms-PS) normalization is investigated. A bias to lower Q(sub rms-PS) is found when the quadrupole is included. The higher normalization for a forced n = 1 fit is then favored by the cross-rms technique.

Banday, A. J.↗

Cross-calibration of liquid and solid QCT calibration standards: corrections to the UCSF normative data

Quantitative computed tomography (QCT) has been shown to be a precise and sensitive method for evaluating spinal bone mineral density (BMD) and skeletal response to aging and therapy. Precise and accurate determination of BMD using QCT requires a calibration standard to compensate for and reduce the effects of beam-hardening artifacts and scanner drift. The first standards were based on dipotassium hydrogen phosphate (K2HPO4) solutions. Recently, several manufacturers have developed stable solid calibration standards based on calcium hydroxyapatite (CHA) in water-equivalent plastic. Due to differences in attenuating properties of the liquid and solid standards, the calibrated BMD values obtained with each system do not agree. In order to compare and interpret the results obtained on both systems, cross-calibration measurements were performed in phantoms and patients using the University of California San Francisco (UCSF) liquid standard and the Image Analysis (IA) solid standard on the UCSF GE 9800 CT scanner. From the phantom measurements, a highly linear relationship was found between the liquid- and solid-calibrated BMD values. No influence on the cross-calibration due to simulated variations in body size or vertebral fat content was seen, though a significant difference in the cross-calibration was observed between scans acquired at 80 and 140 kVp. From the patient measurements, a linear relationship between the liquid (UCSF) and solid (IA) calibrated values was derived for GE 9800 CT scanners at 80 kVp (IA = [1.15 x UCSF] - 7.32).(ABSTRACT TRUNCATED AT 250 WORDS).

NASA Program Space Physiology and Countermeasures↗

Spectroscopy of Jet-Cooled Neutral and Ionized PAHs: Implications for Interstellar Dust

We present the gas-phase spectroscopy of neutral and ionized polycyclic aromatic hydrocarbons (PAHs) measured in the W-Visible-NIR range in an astrophysically relevant environment. These measurements provide data on PAHs and nanometer sized particles that can now be directly compared to astronomical observations. The harsh physical conditions of the IS medium - characterized by a low temperature, an absence of collisions and strong VUV radiation fields - are simulated in the laborat'ory by associating a molecular beam with an ionizing discharge to generate a cold plasma expansion. PAH ions are formed from the neutral precursors in an isolated environment at low temperature ($\sim lOO$-K). The spectra of neutral and ionized PAHs are measured using the high sensitivity methods of cavity ring down spectroscopy (CRDS) and multiplex integrated cavity output spectroscopy (MICOS). These experiments provide unique information on the spectra of free, cold large carbon molecules and ions in the gas phase. The electronic bands measured for ionized PAH are found to be intrinsically broad ($\geq$20 cm$^{-l}$) while the bands associated with the neutral precursors are narrower (of the order of 2 - 10 cm$^{-l}$). The laboratory data are discussed and compared with recent astronomical spectra of large and narrow DIBs and with the spectra of circumstellar environments of selected carbon stars (see contribution of Cami et al.) and the implications for the interstellar PAH population are derived. Preliminary results also show that carbon nanoparticles are formed during the short residence time of the precursors in the plasma. This finding holds great potential for understanding the formation process of interstellar grains.

Salama, F.↗

Astrochemistry: Recent Advances in the Study of Carbon Molecules in Space

Carbon molecules and ions play an important role in space. Polycyclic Aromatic Hydrocarbons (PAHs) are the best-known candidates to account for the infrared emission bands (UIR bands) and PAH spectral features are now being used as probes of the interstellar medium in Galactic and extra-galactic environments. PAHs are also thought to be among the carriers of the diffuse interstellar absorption bands (DIBs). In the model dealing with the interstellar spectral features, PAHs are present as a mixture of radicals, ions and neutral species. PAH ionization states reflect the ionization balance of the medium while PAH size, composition, and structure reflect the energetic and chemical history of the medium. A major challenge for laboratory Astrochemistry is to reproduce (in a realistic way) the physical conditions that exist in the emission and absorption interstellar zones. An extensive laboratory program has been developed in various laboratories to characterize the physical and chemical properties of PAHs in astrophysical environments and to describe how they influence the radiation and energy balance in space and the interstellar chemistry. In particular, laboratory experiments provide measurements of the spectral characteristics of interstellar PAH analogs from the ultraviolet and visible range to the infrared range for comparison with astronomical data. The harsh physical conditions of the interstellar medium - characterized by a low temperature, an absence of collisions and strong ultraviolet radiation fields - are simulated in the laboratory by associating a molecular beam with an ionizing discharge to generate a cold plasma expansion. PAH ions are formed from the neutral precursors in an isolated environment at low temperature (of the order of 100 K). The spectra of neutral and ionized PAHs are measured using the high sensitivity methods of cavity ring down spectroscopy (CRDS). These experiments provide unique information on the spectra of free, cold large carbon molecules and ions in the gas phase.

Salama, Farid↗

Transesophageal Echocardiography and Contrast-TCD in the Detection of a Patent Foramen Ovale: Experience with 111 Patients

Patent foramen ovale (PFO) is increasingly recognized in association with cryptogenic stroke. Using transesophageal echocardiography (TEE) and transcranial Doppler sonography with ultrasonic contrast medium contrast-(TCD), we evaluated the frequency of a PFO as the fundamental condition of paradoxical embolism in 111 patients after cerebral ischemia. There was a right-left shunt in 50 patients (45%) with TEE. In 31 of 40 patients with stroke of unknown etiology, a PFO was the only detectable finding associated with cerebral ischemia. Using TEE as he "gold standard," the sensitivity of contrast-TCD was 91.3%, specificity 93.8%, and the overall accuracy 92.8%. contrast-TCD failed to detect a right-left shunt in four patients, but there were four other patients with negative TEE and positive contrast-TCD. We conclude that contrast-TCD is a highly sensitive method for detecting a right-left shunt. Its advantages are low cost, its ability to detect single contrast-medium embolism, and control of the Valsalva maneuver by observing the decrease of cerebral blood flow. Evidence of PFO in cryptogenic stroke should prompt a search for a subclinical venous thrombosis as the embolic source.

Klotzsch, Christof↗

Noninvasive Diagnosis of Coronary Artery Disease Using 12-Lead High-Frequency Electrocardiograms

A noninvasive, sensitive method of diagnosing certain pathological conditions of the human heart involves computational processing of digitized electrocardiographic (ECG) signals acquired from a patient at all 12 conventional ECG electrode positions. In the processing, attention is focused on low-amplitude, high-frequency components of those portions of the ECG signals known in the art as QRS complexes. The unique contribution of this method lies in the utilization of signal features and combinations of signal features from various combinations of electrode positions, not reported previously, that have been found to be helpful in diagnosing coronary artery disease and such related pathological conditions as myocardial ischemia, myocardial infarction, and congestive heart failure. The electronic hardware and software used to acquire the QRS complexes and perform some preliminary analyses of their high-frequency components were summarized in Real-Time, High-Frequency QRS Electrocardiograph (MSC- 23154), NASA Tech Briefs, Vol. 27, No. 7 (July 2003), pp. 26-28. To recapitulate, signals from standard electrocardiograph electrodes are preamplified, then digitized at a sampling rate of 1,000 Hz, then analyzed by the software that detects R waves and QRS complexes and analyzes them from several perspectives. The software includes provisions for averaging signals over multiple beats and for special-purpose nonrecursive digital filters with specific low- and high-frequency cutoffs. These filters, applied to the averaged signal, effect a band-pass operation in the frequency range from 150 to 250 Hz. The output of the bandpass filter is the desired high-frequency QRS signal. Further processing is then performed in real time to obtain the beat-to-beat root mean square (RMS) voltage amplitude of the filtered signal, certain variations of the RMS voltage, and such standard measures as the heart rate and R-R interval at any given time. A key signal feature analyzed in the present method is the presence versus the absence of reduced-amplitude zones (RAZs). In terms that must be simplified for the sake of brevity, an RAZ comprises several cycles of a high-frequency QRS signal during which the amplitude of the high-frequency oscillation in a portion of the signal is abnormally low (see figure). A given signal sample exhibiting an interval of reduced amplitude may or may not be classified as an RAZ, depending on quantitative criteria regarding peaks and troughs within the reduced-amplitude portion of the high-frequency QRS signal. This analysis is performed in all 12 leads in real time.

Schlegel, Todd T.↗

Small Body Landing Accuracy Using In-Situ Navigation

Spacecraft landings on small bodies (asteroids and comets) can require target accuracies too stringent to be met using ground-based navigation alone, especially if specific landing site requirements must be met for safety or to meet science goals. In-situ optical observations coupled with onboard navigation processing can meet the tighter accuracy requirements to enable such missions. Recent developments in deep space navigation capability include a self-contained autonomous navigation system (used in flight on three missions) and a landmark tracking system (used experimentally on the Japanese Hayabusa mission). The merging of these two technologies forms a methodology to perform autonomous onboard navigation around small bodies. This paper presents an overview of these systems, as well as the results from Monte Carlo studies to quantify the achievable landing accuracies by using these methods. Sensitivity of the results to variations in spacecraft maneuver execution error, attitude control accuracy and unmodeled forces are examined. Cases for two bodies, a small asteroid and on a mid-size comet, are presented.

in-situ navigation↗

Electride Mediated Surface Enhanced Raman Scattering (SERS)

An electride may provide surface enhanced Raman scattering (SERS). The electride, a compound where the electrons serve as anions, may be a ceramic electride, such as a conductive ceramic derived from mayenite, or an organic electride, for example. The textured electride surface or electride particles may strongly enhance the Raman scattering of organic or other Raman active analytes. This may also provide a sensitive method for monitoring the chemistry and electronic environment at the electride surface. The results are evidence of a new class of polariton (i.e., a surface electride-polariton resonance mechanism) that is analogous to the surface plasmon-polariton resonance that mediates conventional SERS.

Anderson, Mark S.↗

The Grayness of the Origin of Life

In the search for life beyond Earth, distinguishing the living from the non-living is paramount. However, this distinction is often elusive, as the origin of life is likely a stepwise evolutionary process, not a singular event. Regardless of the favored origin of life model, an inherent “grayness” blurs the theorized threshold defining life. Here, we explore the ambiguities between the biotic and the abiotic at the origin of life. The role of grayness extends into later transitions as well. By recognizing the limitations posed by grayness, life detection researchers will be better able to develop methods sensitive to prebiotic chemical systems and life with alternative biochemistries.

Origin of life↗

Supporting Crew Medical Decisions on Deep Space Missions: A Real-Time Performance Monitoring

Crewed missions into deep space will require astronauts to respond autonomously to safety- and time-critical anomalies. These and other potential issues will require the continuous monitoring and recognition of potentially subtle, but complex, anomalous data patterns. NASA continues to investigate real-time metrics for Extravehicular Operations1 and for providing feedback to improve performance2. Since it is unknown how long-term exposure to deep space will affect crew health, continuous monitoring of clinical and subclinical status is warranted. NASA is characterizing crew medical decision-support needs and identifying the recommended requirements of a Clinical Decision Support System (CDSS) within the Exploration Medical Capability Element (ExMC) of the Human Research Program3. Early detection, and continuous monitoring, of performance may provide an effective prognostic capability for assessing crew health state, and the identified requirements could be provided for an in-vehicle CDSS that acts as an assistant for delivering optimal health and performance and medical care during exploration missions. There is evidence to suggest that automatic, unobtrusive collection of keystroke features, such as alphanumeric key latencies, backspaces or typing rhythm, could be a valuable performance screening tool. Keystroke features show significant differences between control subjects and patients with overt clinical illness, such as multiple sclerosis4 and Parkinson’s disease5, as well as behavioral health and performance issues, such as mild cognitive impairment6 and depression7. This work is exploring a capability for the assessment of early task performance decline in crew as they perform daily activities. Timestamped keyboard entries are continuously collected and stored. Nominal keystroke interactions are compared to those obtained after exposure to spaceflight stressors, e.g., fatigue, to determine the methods sensitivity. This work will pave the way toward an objective detection tool that may be deployed in a spaceflight setting.

clinical↗

Advanced Statistical Methods in Spacecraft Flight Software Cost Estimation: Bayesian Regression and Nonlinear Principal Components Analysis to Support System Engineering in the Early Project Lifecycle

This paper provides an overview of the new features and model updates in the upcoming release of the NASA Analogy Software Cost Tool (ASCoT). ASCoT, hosted within the Online NASA Space Estimation Tools (ONSET) on the One NASA Cost Engineering (ONCE) Database, is a web-based tool that provides a suite of estimation tools to support early lifecycle NASA flight software cost analysis. In addition to the traditional parametric flight software costing method COCOMO II, ASCoT contains a Bayesian linear regression to predict total flight software development cost as a function of total spacecraft cost, as well as four analogic methods: k-Nearest Neighbors (kNN) and Clustering models to predict Effort (in work-months) and total source lines of code (SLOC). These methods are designed to work primarily with system-level inputs such as mission type (orbiter, lander, etc.), mission destination (Earth, Inner Planetary, etc.), and the number of instruments and deployables. Nonlinear principal components analysis (NLPCA) is performed to find the principal features of the data composed of both categorical and numerical variables and is necessary prior to defining our analogic methods. Sensitivity analyses and in- and out-of-sample model performance results are presented for the Bayesian CER and the analogic models.

Johnson, James K.↗

Energy sensitization of acceptors and donors in organic photovoltaics

Disclosed herein are organic photosensitive optoelectronic devices comprising acceptor and/or donor sensitizers to increase absorption and photoresponse of the photoactive layers of the devices. In particular, devices herein include at least one acceptor layer and at least one donor layer, wherein the acceptor layer may comprise a mixture of an acceptor material and at least one sensitizer, and the donor layer may comprise a mixture of a donor material and at least one sensitizer. Methods of fabricating the organic photosensitive optoelectronic devices are also disclosed.

14 SOLAR ENERGY↗

Dual phase multiplex polymerase chain reaction

Highly specific and sensitive methods were developed for multiplex amplification of nucleic acids on supports such as microarrays. Based on a specific primer design, methods include five types of amplification that proceed in a reaction chamber simultaneously. These relate to four types of multiplex amplification of a target DNA on a solid support, directed by forward and reverse complex primers immobilized to the support and a fifth type--pseudo-monoplex polymerase chain reaction (PCR) of multiple targets in solution, directed by a single pair of unbound universal primers. The addition of the universal primers in the reaction mixture increases the yield over the traditional "bridge" amplification on a solid support by approximately ten times. Methods that provide multitarget amplification and detection of as little as 0.45-4.5.times.10.sup.-12 g (equivalent to 10.sup.2-10.sup.3 genomes) of a bacterial genomic DNA are disclosed.

59 BASIC BIOLOGICAL SCIENCES↗

Methods for electropolishing and coating aluminum on air and/or moisture sensitive substrates

Methods for electropolishing and coating aluminum on a surface of an air and/or moisture sensitive substrate, including: in a vessel, submerging the substrate in a first molten salt bath and applying an anodizing current to the substrate at a first temperature to electropolish the surface of the substrate; wherein the first molten salt bath includes one of a first organic salt bath and first inorganic salt bath; wherein, when used, the first organic salt bath includes one of (a) aluminum halide and ionic liquid, (b) a combination of an aluminum halide and halogenatedmethylphenylsulfone (C 6 (H 5−y ,X y )SO 2 CX 3 , where y is a number from 0-5), (c) a combination of an aluminum halide, an ionic liquid, and halogenatedmethylphenylsulfone (C 6 (H 5−y ,X y )SO 2 CX 3 ), and (d) AlF 3 -organofluoride-hydrofluoric acid adduct; wherein, when used, the first inorganic salt bath includes aluminum halide and alkali metal halide; and wherein the anodizing current is 10-30 mA/cm 2 .

Freiderich, John W.↗

Methods for electropolishing and coating aluminum on air and/or moisture sensitive substrates

Methods for electropolishing and coating aluminum on a surface of an air and/or moisture sensitive substrate, including: in a vessel, submerging the substrate in a first molten salt bath and applying an anodizing current to the substrate at a first temperature to electropolish the surface of the substrate; wherein the first molten salt bath includes one of a first organic salt bath and first inorganic salt bath; wherein, when used, the first organic salt bath includes one of (a) aluminum halide and ionic liquid, (b) a combination of an aluminum halide and halogenatedmethylphenylsulfone (C 6 (H 5-y ,X y )SO 2 CX 3 , where y is a number from 0-5), (c) a combination of an aluminum halide, an ionic liquid, and halogenatedmethylphenylsulfone (C 6 (H 5-y ,X y )SO 2 CX 3 ), and (d) AlF 3 -organofluoride-hydrofluoric acid adduct; wherein, when used, the first inorganic salt bath includes aluminum halide and alkali metal halide; and wherein the anodizing current is 10-30 mA/cm 2 .

Freiderich, John W.↗

Radiation sensitive area detection device and method

A radiation sensitive area detection device for use in conjunction with an X ray, ultraviolet or other radiation source is provided which comprises a phosphor containing film which releases a stored diffraction pattern image in response to incoming light or other electromagnetic wave. A light source such as a helium-neon laser, an optical fiber capable of directing light from the laser source onto the phosphor film and also capable of channelling the fluoresced light from the phosphor film to an integrating sphere which directs the light to a signal processing means including a light receiving means such as a photomultiplier tube. The signal processing means allows translation of the fluoresced light in order to detect the original pattern caused by the diffraction of the radiation by the original sample. The optical fiber is retained directly in front of the phosphor screen by a thin metal holder which moves up and down across the phosphor screen and which features a replaceable pinhole which allows easy adjustment of the resolution of the light projected onto the phosphor film. The device produces near real time images with high spatial resolution and without the distortion that accompanies prior art devices employing photomultiplier tubes. A method is also provided for carrying out radiation area detection using the device of the invention.

Carter, Daniel C.↗