Search NASA⌕ Search

SEARCH · Search NASA

Results for “sensitivity methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Formation and Detriments of Residual Alkaline Compounds on High-Nickel Layered Oxide Cathodes

High-nickel layered oxides LiNi x M 1-x O 2 (x ≥ 0.9) have emerged as promising cathode materials for automotive batteries due to their high energy density and lower cost. However, the formation and accumulation of surface alkaline compounds during storage hinder their mass production and commercialization. Here, in this study, a validated chemical method is employed to deconvolute and quantify the evolution of each residual lithium compound in four representative cathodes during ambient-air storage, viz., LiNiO 2 (LNO), LiNi 0.95 Co 0.05 O 2 (NC), LiNi 0.95 Mn 0.05 O 2 (NM), and LiNi 0.95 Al 0.05 O 2 (NA). Furthermore, the activation energy of the reaction between water and the cathode is determined by measuring the leached LiOH concentration at various temperatures. While residual lithium and time-of-flight secondary-ion mass spectrometry measurements collectively reveal that the air stability overall follows the trend of NM > NA ≈ NC > LNO, the aged NM exhibits the highest charge-transfer resistance and the worst electrochemical performance among the cathodes. In situ, X-ray diffraction and scanning transmission electron microscopy unveil that the aged NM is plagued by a large area of resistive spinel-like M 3–x Li x O 4 phases, leading to aggravated particle reaction heterogeneity. Finally, a one-step recalcination method is demonstrated effective in fully restoring the degraded cathodes. This work provides insights into overcoming air sensitivity issues of high-Ni cathodes.

(S)TEM↗

Frictionless knowledge injection for few-shot learning

Cutting-edge machine learning methods often require large volumes of curated training data, precluding their use in national security problems with rare events in massive datasets. We present a method for incorporating abstract knowledge into models tailored for sparse data. A subject matter expert defines salient concepts using data examples, which are encoded in the model’s embedding space. Models are then trained to respect these concepts. This method enables knowledge injection, yielding effective models with limited labeled data and the ability to assess model sensitivity for subject matter expertise across the nonproliferation mission space, as demonstrated with Raman spectra analysis.

Stomps, Jordan [ORNL] (ORCID:0000000178114479)↗

Thickness and uniformity mapping of thin foils using resistive silicon detectors

Alpha energy loss is a common tool used for measuring target thicknesses. However, these measurements are often made without position information, which either forfeits knowledge of material uniformity and local thickness or requires a prohibitive number of measurements per target to partially recover this information. In consideration of this, a method for measuring position-dependent thicknesses is described in this work; by using the position-sensitivity of the dual-axis duo-lateral (DADL) silicon detector, thicknesses across the entire face of the material can be measured to sub-mm precision with a single measurement. Several examples are presented using a number of targets with varying characteristics, which altogether demonstrate the precision, accuracy, and versatility of this technique.

Foil uniformity↗

Emulation With Uncertainty Quantification of Regional Sea‐Level Change Caused by the Antarctic Ice Sheet

Abstract Projecting regional sea‐level change under various climate‐change scenarios typically involves running forward simulations of the Earth's gravitational, rotational and deformational (GRD) response to ice‐mass change, which requires substantial computational cost if applied to probabilistic frameworks requiring thousands to millions of samples. Here we build emulators of regional sea‐level change at 27 coastal locations, due to the GRD effects associated with future Antarctic Ice Sheet mass change over the 21st century. The emulators are evaluated against a numerical sea‐level model applied to an ensemble of ice‐sheet model simulations of the Antarctic Ice Sheet through 2100. We build a physics‐based emulator using a recent sensitivity kernel approach and compare it to machine learning based emulators (neural network and conditional variational autoencoder methods). In order to quantify uncertainty, we derive well‐calibrated prediction intervals for regional sea‐level change via split‐conformal inference and linear regression, and show that Monte Carlo dropout does not yield well‐calibrated uncertainties in this instance. We also demonstrate substantial gains in computational efficiency using both the physics‐based emulator and neural networks in comparison to the numerical model for the complete regional sea‐level solution. Overall, we find the physics‐based emulator modestly outperforms the machine learning emulators for this problem.

58 GEOSCIENCES↗

Search for the 𝐾 𝐿 → 𝜋 0 ⁢$𝜈⁢\bar{𝜈}$ Decay at the J-PARC KOTO Experiment

We performed a search for the 𝐾 𝐿 → 𝜋 0 ⁢$𝜈⁢\bar{𝜈}$ decay using the data taken in 2021 at the J-PARC KOTO experiment. With newly installed counters and new analysis method, the expected background was suppressed to 0.252 ± 0.055 stat ⁢ $^{+0.052}_{{−0.067^{syst}}}$. With a single event sensitivity of (9.33 ± 0.0⁢6 stat ±0.8⁢4 syst ) × 10 −10 , no events were observed in the signal region. An upper limit on the branching fraction for the decay was set to be 2.2 ×10 −9 at the 90% confidence level (C.L.), which improved the previous upper limit from KOTO by a factor of 1.4. With the same data, a search for 𝐾 𝐿 → 𝜋 0 ⁢𝑋 0 was also performed, where 𝑋 0 is an invisible boson with a mass ranging from 1 to 260 MeV/𝑐 2 . For 𝑋 0 with a mass of 135 MeV/𝑐 2 , an upper limit on the branching fraction of 𝐾 𝐿 → 𝜋 0 ⁢𝑋 0 was set to be 1.6 ×10 −9 at the 90% C.L.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A tunable dielectric resonator for axion searches at 11 GHz

In the context of axion search with haloscopes, tunable cavity resonators with high quality factor and high effective volume at frequencies above about 8 GHz are central for probing the axion-photon coupling with the required sensitivity to reach the QCD axion models. Higher order modes in dielectrically-loaded cavities allow for higher effective volumes and larger quality factors compared to basic cylindrical cavities, but a proper cavity frequency tuning mechanism to probe broad axion mass ranges is yet not available. In this work, we report about the design and construction of a tunable prototype of a single-shell dielectric resonator with its axion-sensitive pseudo-TM$_{030}$ high-order mode at about 11 GHz frequency. A clamshell tuning method previously tested for empty cylindrical resonators has been perfected for this geometry through simulations and in situ tests conducted at cryogenic temperature. Tuning is accomplished in a range of about 2 $\%$ the central frequency, without significantly impacting the quality factor of about 175000. The experimental results presented in this work demonstrate the tunability of this type of resonator, definitely confirming its applicability to high frequency axion searches.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detection and imaging of electric fields, using polarized neutrons

A method and corresponding apparatus are provided for measuring neutron spin precession in an electric field with high sensitivity suitable for practical applications in non-destructive testing, imaging, and the like. Production of a neutron beam with a polarization vector P is followed by transmitting the spin-polarized neutron beam through a sample region in which there is a target generating an electric field, polarization-analyzing the transmitted neutron beam with an analyzing direction orthogonal to P, detecting an intensity of the polarization-analyzed neutron beam; and mapping the detected neutron-beam intensity to a field-strength value for the target electric field.

Jau, Yuan-Yu↗

Quantifying Phospholipids in Organic Samples Using a Hydrophilic Interaction Liquid Chromatography–Inductively Coupled Plasma High-Resolution Mass Spectrometry (HILIC-ICP-HRMS) Method

Here, in this study, a novel method using hydrophilic interaction liquid chromatography (HILIC) coupled with inductively coupled plasma high-resolution mass spectrometry (ICP-HRMS) was introduced for the quantification of phospholipids in oil samples. The method employed a bridged ethyl hybrid (BEH) stationary phase HILIC column with a tetrahydrofuran (THF)/water mobile phase, enhancing the solubility and detection of phospholipids. During the study, a gradient/matrix effect on ICP-HRMS sensitivity was observed and successfully compensated for experimentally, ensuring reliable quantification results. This approach has proven effective for a wide range of different oil samples including vegetable oils, animal fats, and phospholipid supplements. Notably, this method allowed the direct quantification of phospholipids in oil samples, bypassing the need for prior sample preparation methods, such as solid phase extraction (SPE), thereby streamlining the analytical process. The precision, accuracy, and reduced need for extensive sample preparation offered by this method mark a significant advancement in lipids analysis. Its robustness and broad applicability have substantial implications for industries such as food and renewable energy production, where both efficient and accurate lipid identification and quantification are crucial.

09 BIOMASS FUELS↗

First-principles computations of the Stark shift of a defect-bound exciton: The case of the T center in silicon

The T center in silicon has recently drawn a lot of attention for its potential in quantum information science. The sensitivity of the zero-phonon line (ZPL) to electrical field was recently investigated by a combination of different experimental methods but there are still few first principles studies on the Stark shift of the T center. Dealing with the defect-bound exciton nature of the excited state is particularly challenging using density functional theory because of the large spatial delocalization associated with the wavefunction. Here, in this work, we tackle this issue by performing a convergence study over the supercell size. We obtain an exciton binding energy of 28.5 meV, in good agreement with experimental results. We then calculate the Stark shift through the dipole moment change of the ZPL transition of the T center using the modern theory of polarization formalism and find a modest linear coefficient of Δ⁢𝜇=0.79⁢D along X and Δ⁢𝜇=0.03⁢𝐷 along Y. We discuss our results in light of the recent experimental measurements of the Stark shift. Our analysis suggests that bound-exciton defects could be particularly sensitive to local field effect as a result of their large spatial extent.

color centers↗

STILGAR End-of-Project Report

The Subsurface Tunnel Imaging LeveraGed by Analysis of Rayleigh wave ellipticity (STILGAR) project demonstrated an integrated geophysical approach for detecting, locating, and characterizing underground structural changes using dense seismic arrays and advanced inversion techniques. Field campaigns were conducted at two operational mines—the Redmond salt mine (Utah) and Graymont Pleasant Gap limestone mine (Pennsylvania)—providing real-world testbeds for monitoring anthropogenic subsurface activity. At the Redmond salt mine, seismic interferometry combined with back-projection inversion successfully identified continuous, low-amplitude signals from mining operations. The approach differentiated stationary from migrating anthropogenic sources, captured daily operational cycles, and validated the potential of passive seismic monitoring for remote detection of underground activity. At the Graymont Pleasant Gap mine, two dense seismic deployments in the spring and fall of 2023 generated over 4 TB of high-resolution data. Key outcomes included the relocation of 199 underground and 8 surface explosions with accuracies within tens of meters and the development of a 3D P-wave velocity model using the triple-difference tomography algorithm (tomoTD) that resolved major structural features such as the mine entrance, low-velocity tunnels, and roof-collapse areas. Ambient noise cross-correlation and back-projection analyses revealed persistent sources linked to ongoing mining activity, whereas horizontal-to-vertical spectral ratio (HVSR) and ellipticity studies confirmed stable site responses across seasons and identified soil thickness trends consistent with regional erosional and depositional processes. Checkerboard and sensitivity tests further validated the robustness of the tomographic results. Overall, the findings emphasize that although significant progress has been made in subsurface imaging, further work is needed to enhance the detection and localization of underground structures. Accurate imaging requires higher frequencies, yet anthropogenic sources tend to dominate the seismic record at those frequencies, and high-frequency surface waves are affected by higher modes that complicate interpretation. The improved detection and localization of human-induced signals enabled detailed temporal and spatial mapping of daily mine operations, demonstrating the feasibility of continuous anthropogenic source monitoring. Sensitivity to signals from nontraditional sources, such as fan operations, highlights the broader applicability of this approach to other industrial environments in which continuous and impulsive signals are present. The field campaigns produced a substantial volume of high-quality seismic data, supporting the development and testing of new methods for seismic source characterization and subsurface imaging. Future deployments should include sensors capable of recording lower frequencies to probe deeper structures, increase bandwidth to enhance resolution and sensitivity to both shallow and deep targets, and collect additional large-scale datasets to refine imaging and source characterization techniques. Moreover, conducting 3D modeling studies of seismic wavefields at higher frequencies will provide a better understanding of wave scattering and cavity–wavefield interactions in complex underground environments. In conclusion, the STILGAR project demonstrated that integrated seismic monitoring can effectively characterize underground operations, capturing both natural and anthropogenic signals. The approaches developed provide a foundation for improved detection, localization, and imaging of subsurface structures and are directly transferable to broader industrial monitoring applications.

58 GEOSCIENCES↗

In‐situ Analysis of Paste Properties in Resonant Acoustic Mixers for Quality Monitoring

Formulation control is key to achieving consistent target properties of energetic materials, as feedstock variations and slight deviations in the ratios of different ingredients can have major effects on final product properties, particularly in dense pastes with high particle loading >65 vol.%. In large‐scale operations, it is imperative to either correct or remove batches of material that perform outside baseline property specifications as early as possible to avoid unnecessary processing of suboptimal material. Quality monitoring is the practice of measuring material properties during processing using process analytical technologies as opposed to only testing the properties of the final product; it is a key principle in the quality‐by‐design frameworks used for designing formulations and manufacturing processes. Herein, a process analytical technology method for correlating material properties of dense pastes directly after mixing in a Resonant Acoustic Mixer to motor data is developed and used to detect differences in the particle content of dense paste formulations. This method was also capable of detecting variations in powder feedstock properties, such as particle packing efficiency, and is sensitive enough to detect changes of 2 wt.% in the total solids content of the formulation. The techniques presented herein show excellent promise for use as a process analytical technology capable of quantifying formulation effects on material movement modes during resonant acoustic mixing.

Materials science↗

Ionic‐Liquid Free and Flexible Transistors Made of 2D Material Inks

The development of thin-film transistors (TFTs) using 2D materials is crucial for enabling scalable, low-cost, and flexible electronics. Currently, 2D TFTs with the highest performance have been achieved by using ionic-liquid gating (ILG), a technique suited for proof-of-concept studies. However, ILG suffers from slow switching speeds, temperature sensitivity, poor long-term stability, and integration challenges, making it unsuitable for practical use. Moreover, typical fabrication methods for 2D TFTs involve harsh conditions such as strong acids or high temperatures (>300 °C), limiting integration with flexible substrates. This work provides the first demonstration of an ILG-free, all-2D-material TFT fabricated onto a flexible substrate. Water-based graphene and hexagonal boron nitride (h-BN) inks are printed to deposit the electrodes and dielectric layers, respectively. The MoS 2 channel is produced via supramolecular interfacial self-assembly, yielding uniform, monolayer-rich films transferable to rigid and flexible substrates. The resulting TFTs operate below 3 V, exhibit negligible leakage current, and achieve field-effect mobilities up to 0.46 cm 2 V −1 s −1 (rising to 2.47 cm 2 V −1 s −1 with silver electrodes) measured under ambient conditions, while maintaining excellent mechanical flexibility. This work establishes a low-cost and scalable solution-processable platform for flexible electronics based on 2D materials that match requirements for practical applications.

2D materials↗

A comprehensive review of diffuse reflectance infrared Fourier transform spectroscopy (DRIFTS) techniques in protonic ceramic cells (PCCs): Current status and future perspective

Protonic ceramic cells (PCCs) have emerged as a promising technology for power generation, energy storage, and value-added chemical synthesis, offering benefits such as fuel flexibility, low emissions, and efficient operation at intermediate temperatures (300–600 ​°C). Recently, significant breakthroughs in materials and manufacturing methods have markedly enhanced the performance of PCCs. However, establishing a fundamental understanding of their electrocatalytic reactions has gained less attention. As a fast and cost-effective method for physicochemical fingerprinting, diffuse reflectance infrared Fourier transform spectroscopy (DRIFTS) has proven to be a surface-sensitive analytical tool for structural and functional studies. This review critically examines the most up-to-date applications of DRIFTS for characterizing key components of PCCs, including oxygen electrodes, protonic electrolytes, and hydrogen electrodes for different applications, with a focus on revealing hydration properties and catalytic reactions, and guiding rational material design. The challenges for advancing DRIFTS, including quantitative capabilities and operando applications for PCC investigations, are highlighted and strategies to tackle these challenges are discussed. Ultimately, this review underscores the critical role of DRIFTS in accelerating the development of high-performance and durable PCCs for next-generation energy solutions, offering methodologies and insights broadly applicable to a wide range of electrochemical energy conversion and storage technologies.

Diffuse Reflectance Infrared Fourier Transform Spe↗

Elemental analysis of air-sensitive frozen molten salt samples using an inert transfer chamber for LIBS/LA-ICP-TOF-MS analysis

A novel inert sample transfer system was developed and employed to enable, for the first time, the analysis of air-sensitive salt samples in a two-volume ablation cell using simultaneous laser-induced breakdown spectroscopy (LIBS) and laser ablation (LA)-inductively coupled plasma (ICP)-time-of-flight (TOF)-mass spectrometry (MS) analysis. Molten salts are of growing interest as a medium for advanced nuclear reactors and nuclear fuel reprocessing technologies continue to be developed around their use. However, compositional analysis of molten salt samples can be challenging because of their air-sensitive nature and varying solubilities leading to inaccurate measurements when digested. LA-based analysis provides an alternate method to digestion and can provide rapid elemental information with little sample preparation. In this study, LIBS and LA-ICP-TOF-MS were used to analyze the Ce content in frozen salt samples taken from a series of electrochemical experiments. Calibrations were built for each technique, and the resulting limits of detection for Ce were estimated to be 107 and 58 µg g −1 for LIBS and LA-ICP-TOF-MS, respectively. Test samples from the electrochemical experiments were analyzed using these calibrations. The results matched bulk digestion-based ICP-optical emission spectroscopy values, and daily trends in Ce concentration changes were identified. Additionally, the LIBS and LA-ICP-TOF-MS analysis was demonstrated for identifying microgram per gram levels of components and detecting trace contaminants. The impurities detected by LIBS included Al, Mg, Ca, and Na. The impurities detected by LA-ICP-TOF-MS included W, Ag, Al, Fe, Ni, Mo, Nd, Sm, Th, and U.

Andrews, Hunter B. [Oak Ridge National Laboratory ↗

Multifrequency eddy-current detection of fast transient thermal signatures for in situ monitoring applications

Eddy-current (EC) nondestructive evaluation has a long history of use in a variety of ex situ defect monitoring applications because of its exquisite sensitivity to local material variations. Due to the relationship between a material's conductivity and its temperature, EC methods have also been used to investigate quasistatic, long-range temperature variations in casting applications. However, these techniques remain underutilized for the measurement of rapidly varying, spatially nonuniform temperature distributions. In this work, we construct a model system capable of generating repeatable temperature transients in steel plates and measure real-time eddy-current signals with millisecond time resolution and spatial resolution of the order of 1 mm. Using a combination of Multiphysics simulations, fast thermal imaging, and time-resolved holographic interferometry, we tease apart contributions to the eddy-current signals arising from temperature variations and transient plate deformation. Finally, we perform a systematic study in which we vary the plate thickness and the eddy-current excitation frequency to demonstrate that eddy-current techniques can provide information about a three-dimensional, time-varying, subsurface thermal distribution, which is inaccessible to the traditional thermal imaging techniques.

Rosenberg, Ethan R. [Lawrence Livermore National L↗

Fiber-optic bolometer with low detection limit fabricated using thermal release tape and precise laser heating

Fiber-optic bolometers (FOBs) based on a fiber-tipped silicon Fabry–Perot (FP) interferometric temperature sensor and a gold disk absorber have been shown to be an attractive alternative to conventional resistive bolometers for plasma radiation measurement in fusion devices. Either a high-finesse FP or a low-finesse FP can be used, each with trade-offs between noise performance and fabrication complexity. In this paper, we present an FOB design that overcomes these limitations by combining a low-finesse long silicon FP cavity with a large gold disk absorber to achieve enhanced sensitivity and noise performance without increasing the fabrication complexity and the time constant. We also demonstrated a fabrication method for the sensor head facilitated by thermal release tape and precise laser heating. Our FOB demonstrates a temperature resolution of 0.08 mK, a cooling time constant of 230 ms, and a noise equivalent power density of 0.015 W m −2 . This represents an eightfold improvement over previous high-finesse FOBs and 26-fold improvement over previous low-finesse FOBs with similar demodulation bandwidths and similar cooling time constants.

Fabry–Perot interferometer↗

Chasing ghosts: characterization of artifact generation in coded aperture decoding due to experimental implementation

Coded aperture imaging is a form of lensless aperture imaging that projects multiple overlapping images of the source onto the detector, enhancing signal strength, which is advantageous for low-flux sources or high-resolution imaging. This technique requires decoding of the detector signal to reconstruct the original source, which involves convolving the detector data with the aperture pattern. When the signal is from a centered point source, the reconstructed source image is known as the point spread function (PSF). A clean PSF without artifacts is a Dirac delta function [Appl. Opt. 20, 1858 (1981)]. This paper examines the robustness of the decoding process against variations in experimental tolerances by analyzing artifact growth in the reconstructed PSF. We illustrate the effects of incorrect magnification, rotation, and detector size and find that aperture–detector rotational misalignment about the imaging axis is the most sensitive parameter, with significant artifact generation occurring with angular offsets of less than one degree. We discuss compensation methods for imperfect aperture placement, finding that small detector sizes produce uncompensatable artifact generation, and compare theoretical predictions with experimental PSF measurements of a rank , 6.8 mm thick (less than one mean free path) coded aperture with a 3.5 mm cell size, conducted at the MegaJOuLe Neutron Imaging Radiography dense plasma focus [IEEE Trans. Plasma Sci. 49, 3299 (2021)] using a 2.45 MeV neutron source. Based on our findings, we recommend using magnified coded apertures in the under-sampled regime, which allows for the inclusion of fiducial markers to characterize aperture–detector rotational offsets and the addition of mechanical coupling, where possible, to constrain rotational and magnification offsets.

Selwood, M. P. [Lawrence Livermore National Labora↗

Ambient field seismology in critical zone hydrological sciences

Passive ambient noise monitoring is an emerging tool in environmental seismology, leveraging the ambient seismic field to assess temporal variations in shallow subsurface properties. This review focuses on the potential and challenges of using scattered coda waves from noise correlation functions to monitor critical zone dynamics. The sensitivity of seismic velocities to various environmental factors, including precipitation, snowmelt, atmospheric pressure, and groundwater fluctuations, underscores the method’s versatility. While coda waves excel in detecting subtle changes due to their scattered nature, ballistic waves provide higher spatial resolution, albeit with challenges in source stability. Advances in seismic sensing, including distributed acoustic sensing and low-cost geophone networks, have enabled high-resolution monitoring of hydrological processes, subsurface deformation, and seismic hazards. Integrating seismic data with hydrological models provides insights into water storage, pore pressure changes, and soil moisture dynamics. However, limitations in spatial resolution, calibration with ground truth data, and coupled effects between environmental factors remain key challenges. This review emphasizes the importance of interdisciplinary approaches in refining methodologies, enhancing sensor deployments, and addressing data gaps. Passive seismic monitoring offers opportunities to understand critical zone processes and their broader impacts on seismic hazards and environmental sustainability.

58 GEOSCIENCES↗