Physical analysis of the radiation shielding for the medical accelerators

Radiation safety standards today require comprehensive shielding protection schemes for all particle accelerators. The original shielding system of BJ-20 (BeiJing-20 MeV), the high-energy medical electron linac, was designed only for the 18 MeV level. And the dose caused by the lost electrons in the 270 deg. bending magnet system was neglected. In this paper, the leakage dose of BJ-20 is carefully analyzed. The radiation leakage dose distribution of the photons coming from the accelerator head is obtained for energy levels of 6, 12, 14, and 18 MeV. The dose of the photoneutrons is especially analyzed for the 18 MeV level. The result gives that even neglecting the dose from the 270 deg. bending magnet system, the shielding system is still not enough for the energy levels lower than 18 MeV. The radiation leakage produced by electrons that are lost in the 270 deg. bending magnet system has been particularly studied. Using beam transport theory and Monte Carlo sampling methods, which have been combined in calculations, we have obtained the distribution of the energy, position, and direction of the lost electrons. These data were then further processed by the Monte Carlo N-particle (MCNP) code as input data. The results show that when the electron loss rate in the 270 deg. bending magnet system is 13.5%, the radiation leakage dose of the photons generated by the lost electrons is 0.1% higher than that at the isocenter, and the corresponding relative leakage dose of the photoneutrons reaches 0.045% around an angle of 170 deg. at 18 MeV level. Both of these parameters exceed radioprotection safety standards for medical accelerators. The original shielding design is therefore not suitable and is also incomplete since the radiation produced by the electrons being lost in the 270 deg. bending magnet system was neglected and the leakage dose for the low-energy levels was not considered in the original design. Our calculations provide a very useful tool for further optimization and design improvement that will enable this radiation shielding to conform to present day safety standards.

61 RADIATION PROTECTION AND DOSIMETRY↗

Charge shielding in magnetized plasmas

The shielding of a charge sheet in a magnetized plasma is investigated by taking account of the diamagnetic drift start-up current in addition to the polarization current. For a charge sheet with an infinitesimal width, the shielding is the same as the conventional Debye shielding if the charge sheet is perpendicular to the magnetic field; the shielding length is {radical}(2) times larger than the conventional one if the charge sheet is parallel to the magnetic field. When the scale length of the charge sheet is comparable or smaller than the ion Larmor radius, the electric field is significantly enhanced within the charge sheet, while far away from the charge sheet, the electric field is shielded to the usual 1/{epsilon}{sub r} level (where {epsilon}{sub r} is the diamagnetic coefficient of the magnetized plasma).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Theoretical prediction of nuclear magnetic shieldings and indirect spin-spin coupling constants in 1,1-, cis-, and trans-1,2-difluoroethylenes

A theoretical prediction of nuclear magnetic shieldings and indirect spin-spin coupling constants in 1,1-, cis- and trans-1,2-difluoroethylenes is reported. The results obtained using density functional theory (DFT) combined with large basis sets and gauge-independent atomic orbital calculations were critically compared with experiment and conventional, higher level correlated electronic structure methods. Accurate structural, vibrational, and NMR parameters of difluoroethylenes were obtained using several density functionals combined with dedicated basis sets. B3LYP/6-311++G(3df,2pd) optimized structures of difluoroethylenes closely reproduced experimental geometries and earlier reported benchmark coupled cluster results, while BLYP/6-311++G(3df,2pd) produced accurate harmonic vibrational frequencies. The most accurate vibrations were obtained using B3LYP/6-311++G(3df,2pd) with correction for anharmonicity. Becke half and half (BHandH) density functional predicted more accurate {sup 19}F isotropic shieldings and van Voorhis and Scuseria's τ-dependent gradient-corrected correlation functional yielded better carbon shieldings than B3LYP. A surprisingly good performance of Hartree-Fock (HF) method in predicting nuclear shieldings in these molecules was observed. Inclusion of zero-point vibrational correction markedly improved agreement with experiment for nuclear shieldings calculated by HF, MP2, CCSD, and CCSD(T) methods but worsened the DFT results. The threefold improvement in accuracy when predicting {sup 2}J(FF) in 1,1-difluoroethylene for BHandH density functional compared to B3LYP was observed (the deviations from experiment were −46 vs. −115 Hz)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Influence of quantum diffraction and shielding on electron-ion collision in two-component semiclassical plasmas

The influence of quantum diffraction and shielding on the electron-ion collision process is investigated in two-component semiclassical plasmas. The eikonal method and micropotential taking into account the quantum diffraction and shielding are used to obtain the eikonal scattering phase shift and the eikonal collision cross section as functions of the collision energy, density parameter, Debye length, electron de Broglie wavelength, and the impact parameter. The result shows that the quantum diffraction and shielding effects suppress the eikonal scattering phase shift as well as the differential eikonal collision cross section, especially, in small-impact parameter regions. It is also shown that the quantum shielding effect on the eikonal collision cross section is more important in low-collision energies. In addition, it is found that the eikonal collision cross section increases with an increase in the density parameter. The variations of the eikonal cross section due to the quantum diffraction and shielding effects are also discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quantum diffraction and shielding effects on the low-energy electron-ion bremsstrahlung in two-component semiclassical plasmas

The quantum diffraction and shielding effects on the low-energy bremsstrahlung process are investigated in two-component semiclassical plasmas. The impact-parameter analysis with the micropotential taking into account the quantum diffraction and shielding effects is employed to obtain the electron-ion bremsstrahlung radiation cross section as a function of the de Broglie wavelength, density parameter, impact parameter, photon energy, and projectile energy. The result shows that the influence of quantum diffraction and shielding strongly suppresses the bremsstrahlung radiation spectrum in semiclassical plasmas. It is found that the quantum diffraction and shielding effects have broaden the photon emission domain. It is also found that the photon emission domain is almost independent of the radiation photon energy. In addition, it is found that the influence of quantum diffraction and shielding on the bremsstrahlung spectrum decreases with an increase of the projectile energy. The density effect on the electron-ion bremsstrahlung cross section is also discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Second Target Station Bunker Shielding with Populated and Unpopulated Neutron Beamlines: Preliminary Design

At the U.S. Department of Energy’s Oak Ridge National Laboratory, the Second Target Station (STS) beamline sources for preliminary design have been used to perform a shielding analysis of the bunker. Prompt total effective dose rates (i.e., neutron plus photon effective dose rates when the proton beam is on) were calculated on top of the bunker roof and outside the bunker wall. These areas outside the bunker will be generally accessible, so the prompt total dose rate in these areas should not exceed 2.5 μSv . h -1 (0.25 mrem . h -1 ). This paper presents the required shielding thicknesses to meet this dose rate limit. In one instance, this dose rate limit is not met: For a combination of populated and unpopulated beamlines, the prompt total dose rate outside the bunker across from the unpopulated beamline, which has less shielding because of the lack of beamline shielding, slightly exceeds 2.5 μSv . h -1 . In conclusion, once more details are known regarding the STS high-density concrete density and composition, a future analysis will investigate the shielding modifications required to reduce the calculated prompt total dose rates for this configuration to less than 2.5 μSv . h -1 .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Decay Dose Shielding Analysis with Hybrid Unstructured Mesh/Constructive Solid Geometry Monte Carlo Calculation and ADVANTG Acceleration

Here, the target segments of the Oak Ridge National Laboratory Second Target Station (STS) neutron production facility become highly activated due to spallation reactions or nuclei transmutation by primary protons and emitted neutrons. Once the target segments are removed from their location within the core vessel, decay dose rates must be accurately quantified to determine the shielding configurations of remote-handling tools and transport casks and to aid in planning maintenance activities. For this analysis, we utilized a hybrid unstructured mesh (UM)/constructive solid geometry approach for calculating spallation products and neutron fluxes, activation calculations using the AARE package that includes the CINDER2008 activation code to calculate the decay photon source at different cooling times, and the ADVANTG code to accelerate the final decay photon transport calculation. Both Type 316 stainless steel (SS-316) and lead were investigated as candidates for shielding materials. The decay photon transport calculation through the thick SS-316 or lead shields exhibited between 25 and 30 orders-of-magnitude attenuations in the radial direction, depending on the shield. Such a difficult shielding calculation required advanced variance reduction. ADVANTG has some missing features, which limits its usability in spallation neutron source applications. It does not support volumetric sources created for MCNP6.2 UM capability. An approximate source was created for this problem. Not only was this approximate source needed for running the ADVANTG calculation to generate the weight windows, but also it was essential to develop source biasing (SB) parameters that were crucial for dramatically accelerating the decay photon transport in this problem. With this approximate source, the analysis was completed in a very reasonable computational time, and the design of the STS remote-handling equipment was finalized. This paper compares the efficiency of Monte Carlo simulations with different weight window and SB parameters calculated using different approximate ADVANTG calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Relativistic effects on the nuclear magnetic shielding in the MF (M=Cu, Ag, Au) series

Relativistic effects on the nuclear magnetic shielding {sigma}(M) of the series of diatomics MF (M=Cu, Ag, Au) are calculated and analyzed using the Dirac-Hartree-Fock (DHF) method in the random phase approximation (RPA). Significant differences due to relativistic effects on the shielding constant {sigma}(M) are found in this series of atoms. The high electronegativity of the fluorine atom works in conjunction with the spin-orbit coupling to increase the calculated value for {sigma}(Au). An unusually large diamagnetic contribution to the shielding constant is observed. Nonrelativistic nuclear magnetic shielding [{sigma}{sup NR}(M)] shows very good linear correlation with the nuclear charge (Z) of the metal, while the relativistic shielding [{sigma}{sup rel}(M)] varies as Z{sup 2.26}.

74 ATOMIC AND MOLECULAR PHYSICS↗

X-ray spectroscopy applied to radiation shielding calculation in mammography

The protective shielding design of a mammography facility requires the knowledge of the scattered radiation by the patient and image receptor components. The shape and intensity of secondary x-ray beams depend on the kVp applied to the x-ray tube, target/filter combination, primary x-ray field size, and scattering angle. Currently, shielding calculations for mammography facilities are performed based on scatter fraction data for Mo/Mo target/filter, even though modern mammography equipment is designed with different anode/filter combinations. In this work we present scatter fraction data evaluated based on the x-ray spectra produced by a Mo/Mo, Mo/Rh and W/Rh target/filter, for 25, 30 and 35 kV tube voltages and scattering angles between 30 and 165 deg. Three mammography phantoms were irradiated and the scattered radiation was measured with a CdZnTe detector. The primary x-ray spectra were computed with a semiempirical model based on the air kerma and HVL measured with an ionization chamber. The results point out that the scatter fraction values are higher for W/Rh than for Mo/Mo and Mo/Rh, although the primary and scattered air kerma are lower for W/Rh than for Mo/Mo and Mo/Rh target/filter combinations. The scatter fractions computed in this work were applied in a shielding design calculation in order to evaluate shielding requirements for each of these target/filter combinations. Besides, shielding requirements have been evaluated converting the scattered air kerma from mGy/week to mSv/week adopting initially a conversion coefficient from air kerma to effective dose as 1 Sv/Gy and then a mean conversion coefficient specific for the x-ray beam considered. Results show that the thickest barrier should be provided for Mo/Mo target/filter combination. They also point out that the use of the conversion coefficient from air kerma to effective dose as 1 Sv/Gy is conservatively high in the mammography energy range and overestimate the barrier thickness.

60 APPLIED LIFE SCIENCES↗

SU-E-T-400: Evaluation of Shielding and Activation at Two Pencil Beam Scanning Proton Facilities

Purpose: To verify acceptably low dose levels around two newly constructed identical pencil beam scanning proton therapy facilities and to evaluate accuracy of pre-construction shielding calculations. Methods: Dose measurements were taken at select points of interest using a WENDI-2 style wide-energy neutron detector. Measurements were compared to pre-construction shielding calculations. Radiation badges with neutron dose measurement capabilities were worn by personnel and also placed at points throughout the facilities. Seven neutron and gamma detectors were permanently installed throughout the facility, continuously logging data. Potential activation hazards have also been investigated. Dose rates near water tanks immediately after prolonged irradiation have been measured. Equipment inside the treatment room and accelerator vault has been surveyed and/or wipe tested. Air filters from air handling units, sticky mats placed outside of the accelerator vault, and water samples from the magnet cooling water loops have also been tested. Results: All radiation badges have been returned with readings below the reporting minimum. Measurements of mats, air filters, cooling water, wipe tests and surveys of equipment that has not been placed in the beam have all come back at background levels. All survey measurements show the analytical shielding calculations to be conservative by at least a factor of 2. No anomalous events have been identified by the building radiation monitoring system. Measurements of dose rates close to scanning water tanks have shown dose rates of approximately 10 mrem/hr with a half-life less than 5 minutes. Measurements around the accelerator show some areas with dose rates slightly higher than 10 mrem/hr. Conclusion: The shielding design is shown to be adequate. Measured dose rates are below those predicted by shielding calculations. Activation hazards are minimal except in certain very well defined areas within the accelerator vault and for objects placed directly in the path of the beam.

60 APPLIED LIFE SCIENCES↗

Paddle-based rotating-shield brachytherapy

Purpose: The authors present a novel paddle-based rotating-shield brachytherapy (P-RSBT) method, whose radiation-attenuating shields are formed with a multileaf collimator (MLC), consisting of retractable paddles, to achieve intensity modulation in high-dose-rate brachytherapy. Methods: Five cervical cancer patients using an intrauterine tandem applicator were considered to assess the potential benefit of the P-RSBT method. The P-RSBT source used was a 50 kV electronic brachytherapy source (Xoft Axxent™). The paddles can be retracted independently to form multiple emission windows around the source for radiation delivery. The MLC was assumed to be rotatable. P-RSBT treatment plans were generated using the asymmetric dose–volume optimization with smoothness control method [Liu et al., Med. Phys. 41(11), 111709 (11pp.) (2014)] with a delivery time constraint, different paddle sizes, and different rotation strides. The number of treatment fractions (fx) was assumed to be five. As brachytherapy is delivered as a boost for cervical cancer, the dose distribution for each case includes the dose from external beam radiotherapy as well, which is 45 Gy in 25 fx. The high-risk clinical target volume (HR-CTV) doses were escalated until the minimum dose to the hottest 2 cm{sup 3} (D{sub 2cm{sup 3}}) of either the rectum, sigmoid colon, or bladder reached their tolerance doses of 75, 75, and 90 Gy{sub 3}, respectively, expressed as equivalent doses in 2 Gy fractions (EQD2 with α/β = 3 Gy). Results: P-RSBT outperformed the two other RSBT delivery techniques, single-shield RSBT (S-RSBT) and dynamic-shield RSBT (D-RSBT), with a properly selected paddle size. If the paddle size was angled at 60°, the average D{sub 90} increases for the delivery plans by P-RSBT on the five cases, compared to S-RSBT, were 2.2, 8.3, 12.6, 11.9, and 9.1 Gy{sub 10}, respectively, with delivery times of 10, 15, 20, 25, and 30 min/fx. The increases in HR-CTV D{sub 90}, compared to D-RSBT, were 16.6, 12.9, 7.2, 3.7, and 1.7 Gy{sub 10}, respectively. P-RSBT HR-CTV D{sub 90}-values were insensitive to the paddle size for paddles angled at less than 60°. Increasing the paddle angle from 5° to 60° resulted in only a 0.6 Gy{sub 10} decrease in HR-CTV D{sub 90} on average for five cases when the delivery times were set to 15 min/fx. The HR-CTV D{sub 90} decreased to 2.5 and 11.9 Gy{sub 10} with paddle angles of 90° and 120°, respectively. Conclusions: P-RSBT produces treatment plans that are dosimetrically and temporally superior to those of S-RSBT and D-RSBT, although P-RSBT systems may be more mechanically challenging to develop than S-RSBT or D-RSBT. A P-RSBT implementation with 4–6 shield paddles would be sufficient to outperform S-RSBT and D-RSBT if delivery times are constrained to less than 15 min/fx.

60 APPLIED LIFE SCIENCES↗

Fabrication of neutron absorbing metal hydride entrained ceramic matrix shield composites

With significant improvement in High Temperature Superconductors (HTS), several projects are adopting HTS technology for fusion power systems. Compact HTS tokamaks offer potential advantages including lower plant costs, enhanced plasma control, and ultimately lower cost of electricity. However, as compact reactors have a reduced radial build to accommodate shielding, HTS degradation due to radiation damage or heating is a significant and potentially design limiting issue. Shielding must mitigate threats to the superconducting coils: neutron cascade damage, heat deposition and potentially organic insulator damage due x-rays. Unfortunately, there are currently no hi-performance shielding materials to enable the potential performance enhancement offered by HTS. In this work, we present a manufacturing method to fabricate a new class of composite shields that are high performance, high operating temperature, and simultaneously neutron absorbing and neutron moderating. The composite design consists of an entrained metal-hydride phase within a radiation stable MgO ceramic host matrix. We discuss the fabrication, characterization, and thermophysical performance data for a series of down-selected composite materials inspired by future fusion core designs and their operational performance metrics. To our knowledge these materials represent the first ceramic composite shield materials containing significant metal hydrides.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evaluations of Space Shielding

A general method of evaluating the efficiency of space vehicle shielding is developed and used to compare various active and passive systems for protection against ionizing radiation. Available permanent magnets are found useless for active shielding, and combined active-passive systems in general are determined to be inefficient. On the other hand, evaluations show that active electrostatic shielding may have possibilities for weight savings if electrical conditions (presently unknown) are favorable therefor in space. Further, a positive potential improvement is calculated for an active shielding system which utilizes superconducting Nb3Sn to provide a confined magnetic flux to deflect incident charged particles; this potential points toward substantial reductions in shield weight for the protection of large vehicles from highly energetic particles. Recommendations are made for further research, particularly for flight experiments to measure directionality of solar flare protons.

SHIELDING↗

THE COMBINATION OF ACTIVE AND PASSIVE SHIELDING

I is conceivable that improved shielding of space vehicles against high-energy charged-particle radiation can be obtained by combining active and passive shielding. Methods of shielding calculations and some preliminary observations pertaining to active-passive shielding are given. An analysis based upon the field of a magnetic dipole indicates that weight savings in bulk shielding can be accomplished.

SPACECRAFT SHIELDING↗

ANALYSIS OF QUARTZ AND TEFLON SHIELDS FOR A PARTICULAR RE-ENTRY MISSION

The transient performance of ablation type heat protection shields is treated herein for the surface of a vehicle returning from outer space to the earth. The vehicle weighs 8640 kg, has a ballistic factor of 500 lb/ft2, re-enters with a speed of 11 km/sec at 120 km altitude, has a lift over drag ratio of -0.5, and is subjected to a maximum deceleration of 7.7 times the gravity constant. By use of well-known equations for the heat transfer and the mass transfer at a heated surface, a numerical calculation method is derived which, for the investigated ablation processes, yields exact transient solutions of the fundamental system of partial differential equations. The method is applied to various quartz shields and to one Teflon shield, which all evaporate so readily under the conditions of the problem at hand that practically no flow of molten shield material exists. The solutions also show comparatively small temperature changes parallel to the surface. The results show that the nose of the vehicle is cooled predominantly by the evaporation of the quartz or the Teflon; the rest of the vehicle's surface is cooled by radiation of the quartz or evaporation of the Teflon. The large mass transfer effects on the nose of the vehicle are detrimental since the resulting low surface temperatures prevent the radiative heat transfer out of the shield, which does not involve any mass loss, from being the desirable governing cooling factor.

ABLATING MATERIAL↗

Lunar Surface Reactor Shielding Study

Nuclear reactor system could provide power to support a long term human exploration to the moon. Such a system would require shielding to protect astronauts from its emitted radiations. Shielding studies have been performed for a Gas Cooled Reactor (GCR) system because it is considered to be the most suitable nuclear reactor system available for lunar exploration, based on its tolerance of oxidizing lunar regolith and its good conversion efficiency (Wright, 2003). The goals of the shielding studies were to provide optimal material shielding configuration that reduces the dose (rem) to the required level in order to protect astronauts, and to estimate the mass of regolith that would provide an equivalent protective effect if it were used as the shielding material. All calculations were performed using MCNPX code, a Monte Carlo transport code.

Monte Carlo N-Particle eXtended (MCNPX)↗

Preliminary Thermal Design of Cryogenic Radiation Shielding

Cryogenic Hydrogen Radiation Shielding (CHRS) is the most mass efficient material radiation shielding strategy for human spaceflight beyond low Earth orbit (LEO). Future human space flight, mission beyond LEO could exceed one year in duration. Previous radiation studies showed that in order to protect the astronauts from space radiation with an annual allowable radiation dose less than 500 mSv, 140 kgm2 of polyethylene is necessary. For a typical crew module that is 4 meter in diameter and 8 meter in length. The mass of polyethylene radiation shielding required would be more than 17,500 kg. The same radiation study found that the required hydrogen shielding for the same allowable radiation dose is 40 kgm2, and the mass of hydrogen required would be 5, 000 kg. Cryogenic hydrogen has higher densities and can be stored in relatively small containment vessels. However, the CHRS system needs a sophisticated thermal system which prevents the cryogenic hydrogen from evaporating during the mission. This study designed a cryogenic thermal system that protects the CHRS from hydrogen evaporation for one to up to three year mission. The design also includes a ground based cooling system that can subcool and freeze liquid hydrogen. The final results show that the CHRS with its required thermal protection system is nearly half of the mass of polyethylene radiation shielding.

radiation↗

Foam With Direction: Unraveling the Anisotropic Radiation Shielding Properties of 2D Boron Nitride Nanoplatelet Foams

Neutron radiation exposure is one of the main challenges faced during space missions. There is a critical need for advanced lightweight radiation shielding materials. Two-dimensional (2D) boron nitride nanoplatelets (BNNP) are excellent candidates for polymer matrix nanofillers due to their superior neutron shielding and thermal and mechanical properties. Furthermore, the 2D material anisotropic behavior unlocks the potential for composite property tailoring. This study fabricated ultra- lightweight lamellar BNNP foams (density 0.05 g cm –3 and 97.5% porous) via freeze-drying processing. The neutron shielding effectiveness or mass absorption coefficient of the BNNP foams with walls perpendicular to the direction of the radiation source was 14.47 cm 2 g –1 , while that of the foam with parallel configuration was only 8.51 cm 2 g –1 . The orientation-dependent neutron radiation shielding properties were modeled using the Beer-Lambert law for porous composite materials. The BNNP foam in this study has the potential to benefit advanced tailorable radiation shielding technologies for future aerospace missions.

Radiation shielding↗