Search NASA⌕ Search

SEARCH · Search NASA

Results for “single photon”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Time-walk and jitter correction in SNSPDs at high count rates

Superconducting nanowire single-photon detectors (SNSPDs) are a leading detector type for time correlated single photon counting, especially in the near-infrared. When operated at high count rates, SNSPDs exhibit increased timing jitter caused by internal device properties and features of the RF amplification chain. Variations in RF pulse height and shape lead to variations in the latency of timing measurements. To compensate for this, we demonstrate a calibration method that correlates delays in detection events with the time elapsed between pulses. The increase in jitter at high rates can be largely canceled in software by applying corrections derived from the calibration process. We demonstrate our method with a single-pixel tungsten silicide SNSPD and show it decreases high count rate jitter. The technique is especially effective at removing a long tail that appears in the instrument response function at high count rates. At a count rate of 11.4 MCounts/s, we reduce the full width at 1% maximum level (FW1%M) by 45%. The method, therefore, enables certain quantum communication protocols that are rate-limited by the FW1%M metric to operate almost twice as fast.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spectrally separable photon-pair generation in dispersion engineered thin-film lithium niobate

Existing nonlinear-optic implementations of pure, unfiltered heralded single-photon sources do not offer the scalability required for densely integrated quantum networks. Additionally, lithium niobate has hitherto been unsuitable for such use due to its material dispersion. We engineer the dispersion and the quasi-phasematching conditions of a waveguide in the rapidly emerging thin-film lithium niobate platform to generate spectrally separable photon pairs in the telecommunications band. Such photon pairs can be used as spectrally pure heralded single-photon sources in quantum networks. We estimate a heralded-state spectral purity of >94% based on joint spectral intensity measurements. Further, a joint spectral phase-sensitive measurement of the unheralded time-integrated second-order correlation function yields a heralded-state purity of (86 ± 5)%.

36 MATERIALS SCIENCE↗

Photoselective isotope fractionation dynamics of N 2 with cosmo and atmospheric chemistry perspectives

Stable isotope ratio measurements provide valuable insights into a broad range of natural processes, from planetary atmospheres and climate to interstellar chemistry. Nitrogen, which has two stable isotopes, exhibits varying isotope ratios across the solar system. To model these observations, the isotope fraction as a function of energy is essential. At the Advanced Light Source (ALS), we measured the photodissociation of molecular nitrogen (N 2 ) with vacuum UV photons where a single photon is sufficiently energetic to dissociate the strong bond. The nitrogen atoms produced are scavenged with H 2 to form ammonia, whose isotopic makeup is determined. Blending the experiments with dynamical computations that include the shielding of light, we examine the isotopic composition and electronic atomic states produced. The measured photodissociation of N 2 at a natural isotopic composition with a frequency broad light beam exceptionally strongly favors the formation of the heavier nitrogen isotope, 15 N. Computations concur and suggest that the maximum in the quantum yield reflects significant variations in the specific electronic quantum states of the product N atoms that have quite different reactivities. Our quantum computations show that at similar energies, photodissociation of 14 N 14 N and 15 N 14 N can lead to different product channels. The computed dynamics include extensive state-selective spin–orbit and nonadiabatic couplings affecting the light absorption and dissociation pathways that proceed via the triplet manifold of states. Our results are relevant for future exploration missions, both in situ and sample-return and for other molecules such as O 2 and CO.

Komarova, Ksenia [Hebrew Univ. of Jerusalem (Israe↗

Quantum ghost imaging microscopy depth-of-field study

Quantum ghost imaging approaches have been proposed to enhance biological microscopy, for example, using 2D visible detectors to provide IR images or providing additional dimensions of spatial or spectral information. Toward the goal of making such imaging schemes practical, we compare image quality and depth-of-field between traditional images and ghost images at the same excitation levels. We measure how image quality and depth-of-field depend on the parameters of the entangled light produced using type-I spontaneous parametric down-conversion (SPDC). We use a pair of time-synchronized, photon-timing single-photon avalanche diode (SPAD) array detectors to capture two distinct microscope imaging paths simultaneously on a photon-pair-by-photon-pair basis: one in a traditional imaging pathway and the other a quantum ghost imaging pathway. We calculate the depth-of-field, resolution, contrast, and signal-to-noise ratio (SNR) through the parameter space of a β-Barium Borate (BBO) type-I bulk non-linear crystal length and angle. Our results provide a basis for choosing parameters for quantum ghost imaging with type-I SPDC sources.

47 OTHER INSTRUMENTATION↗

Using quantum noise correlation analysis to measure ion temperature

Quantum noise correlation analysis was tested at the proof-of-concept level as a technique to measure ion temperature in a plasma. If eventually successful, this technique could enable a compact, inexpensive, and robust ion temperature diagnostic suitable for a burning plasma environment. Ion temperature is a key parameter determining the fusion performance of a burning plasma, as the fusion cross-section has a strong dependence on ion temperature. This ion temperature diagnostic would require only a small optical view of the plasma through a port to passively record impurity line emission. The instrumentation would be remote from the reactor behind the neutron and bio-shielding. The technique relies solely on quantum correlations of the photons emitted by a plasma impurity to measure ion temperature; there is no grating dispersion of an emission line-width or pulse-height analysis of photon energy. This measurement innovation was tested with instrumentation consisting of two single-photon detectors with high timing resolution, a time-tagging unit, and simple light collection optics. This instrumentation measures the second-order correlation between the light intensity falling on the two detectors. The next steps beyond the proof-of-concept level will be development of diagnostic designs for application of this technique to high-temperature and burning plasmas. Arrays of single-photon avalanche detectors to multiplex measurements of photon correlation will be required to reduce signal integration time to an acceptable duration.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Broadband Light Extraction from Near-Surface NV Centers Using Crystalline-Silicon Antennas

We use crystalline silicon (Si) antennas to efficiently extract broadband single-photon fluorescence from shallow nitrogen-vacancy (NV) centers in diamond into free space. Our design features relatively easy-to-pattern high-index Si resonators on the diamond surface to boost photon extraction by overcoming total internal reflection and Fresnel reflection at the diamond-air interface and providing modest Purcell enhancement, without etching or otherwise damaging the diamond surface. In simulations, ∼17 times more single photons are collected from a single NV center compared to the case without the antenna; in experiments, we observe an enhancement of ∼9 times, limited by spatial alignment between the NV and the antenna. Furthermore, our approach can be readily applied to other color centers in diamond, and more generally to the extraction of light from quantum emitters in wide-bandgap materials.

Antennas↗

Superconducting Sensors for Microwave and Optical Photon-Starved Communications (Plenary)

NASA mission modeling indicates a desire for approximately a tenfold data improvement per decade from the Deep Space Network through the year 2040. Some of this improvement will come from aperture enhancement and antenna arraying, increased use of Ka-band over X-band, and high performance optical terminals (e.g. 12 m ground telescope). The remainder will depend on "disruptive" technologies. Deep-space communications differs from near earth communications. One way light travel times are measured in minutes rather than seconds and distances involved are large enough such that optical signals are photon limited and microwave signals have extremely low flux density. High frequency SQIF receivers and single photon detectors for optical communications will be described. Specifically, progress towards a "noiseless" receiver based on arrays of incommensurate area SQUIDs, and single photon counting detectors based on superconducting nanowires and kinetic inductance effects, will be discussed. Finally, the design of an optimal array of optical telescopes to emulate performance of a monolithic 12 m telescope will be outlined. In this case, optimal means minimizing the initial capital investment and operational cost while maintaining performance requirements of the deep-space link.

Romanofsky, Bob↗

Femtosecond Photon-Counting Receiver

An optical correlation receiver is described that provides ultra-precise distance and/or time/pulse-width measurements even for weak (single photons) and short (femtosecond) optical signals. A new type of optical correlation receiver uses a fourth-order (intensity) interferometer to provide micron distance measurements even for weak (single photons) and short (femtosecond) optical signals. The optical correlator uses a low-noise-integrating detector that can resolve photon number. The correlation (range as a function of path delay) is calculated from the variance of the photon number of the difference of the optical signals on the two detectors. Our preliminary proof-of principle data (using a short-pulse diode laser transmitter) demonstrates tens of microns precision.

Photons↗

Femtosecond Photon-Counting Receiver

An optical correlation receiver is described that provides ultra-precise distance and/or time/pulse-width measurements even for weak (single photons) and short (femtosecond) optical signals. A new type of optical correlation receiver uses a fourth-order (intensity) interferometer to provide micron distance measurements even for weak (single photons) and short (femtosecond) optical signals. The optical correlator uses a low-noise-integrating detector that can resolve photon number. The correlation (range as a function of path delay) is calculated from the variance of the photon number of the difference of the optical signals on the two detectors. Our preliminary proof-of principle data (using a short-pulse diode laser transmitter) demonstrates tens of microns precision.

Photons↗

Telecom-to-visible quantum frequency converter on a silicon nitride chip

Quantum frequency conversion serves a key role in the realization of hybrid quantum networks by interfacing between wavelength-incompatible platforms. Here we present what is believed to be the first quantum frequency converter connecting visible and telecom domains on a silicon nitride (SiN) chip, using Bragg-scattering four-wave mixing to upconvert heralded single photons from 1260 to 698 nm, which covers a 192 THz span. We examine the noise sources in SiN and devise approaches to suppress noise photons at the source and target frequencies to enable measurements at the single-photon level. We demonstrate an on-chip conversion efficiency of 5% in photon flux and describe design modifications that can be implemented to significantly improve it. Our results pave the way for the implementation of complementary metal-oxide-semiconductor (CMOS)-compatible devices in quantum networks.

59 BASIC BIOLOGICAL SCIENCES↗

The Role of Defect Geometry in Localized Emission from Monolayer Tungsten Dichalcogenides

In two-dimensional transition metal dichalcogenides such as tungsten diselenide (WSe 2 ), single photon emission has been broadly attributed to exciton localization from atomic point defects, yet the precise microscopic origins are unclear. This work introduces an empirically grounded computational framework that explains the origins of facile single photon emission in WSe 2 . High-resolution microscopy identifies native defect geometries in monolayer WSe 2 lattices from which the model is built. Here, the qualitative effects of chalcogen type, defect geometry, and mechanical strain on the electronic structure are individually assessed using density functional theory, and a specific divacancy configuration emerges as the candidate for localized single-electron transitions that match observed spectral energies. Spectroscopy and photon correlation measurements further validate this model, establishing a self-consistent link between defect geometry, electronic structure, and quantum emission.

defect emission↗

High-performance silicon photonic single-sideband modulators for cold-atom interferometry

The laser system is the most complex component of a light-pulse atom interferometer (LPAI), controlling frequencies and intensities of multiple laser beams to configure quantum gravity and inertial sensors. Its main functions include cold-atom generation, state preparation, state-selective detection, and generating a coherent two-photon process for the light-pulse sequence. To achieve substantial miniaturization and ruggedization, we integrate key laser system functions onto a photonic integrated circuit. Our study focuses on a high-performance silicon photonic suppressed-carrier single-sideband (SC-SSB) modulator at 1560 nanometers, capable of dynamic frequency shifting within the LPAI. By independently controlling radio frequency (RF) channels, we achieve 30-decibel carrier suppression and unprecedented 47.8-decibel sideband suppression at peak conversion efficiency of –6.846 decibels (20.7%). We investigate imbalances in both amplitudes and phases between the RF signals. Using this modulator, we demonstrate cold-atom generation, state-selective detection, and atom interferometer fringes to estimate gravitational acceleration, g ≈ 9.77 ± 0.01 meters per second squared, in a rubidium ( 87 Rb) atom system.

47 OTHER INSTRUMENTATION↗

Photon Counting Using Edge-Detection Algorithm

New applications such as high-datarate, photon-starved, free-space optical communications require photon counting at flux rates into gigaphoton-per-second regimes coupled with subnanosecond timing accuracy. Current single-photon detectors that are capable of handling such operating conditions are designed in an array format and produce output pulses that span multiple sample times. In order to discern one pulse from another and not to overcount the number of incoming photons, a detection algorithm must be applied to the sampled detector output pulses. As flux rates increase, the ability to implement such a detection algorithm becomes difficult within a digital processor that may reside within a field-programmable gate array (FPGA). Systems have been developed and implemented to both characterize gigahertz bandwidth single-photon detectors, as well as process photon count signals at rates into gigaphotons per second in order to implement communications links at SCPPM (serial concatenated pulse position modulation) encoded data rates exceeding 100 megabits per second with efficiencies greater than two bits per detected photon. A hardware edge-detection algorithm and corresponding signal combining and deserialization hardware were developed to meet these requirements at sample rates up to 10 GHz. The photon discriminator deserializer hardware board accepts four inputs, which allows for the ability to take inputs from a quadphoton counting detector, to support requirements for optical tracking with a reduced number of hardware components. The four inputs are hardware leading-edge detected independently. After leading-edge detection, the resultant samples are ORed together prior to deserialization. The deserialization is performed to reduce the rate at which data is passed to a digital signal processor, perhaps residing within an FPGA. The hardware implements four separate analog inputs that are connected through RF connectors. Each analog input is fed to a high-speed 1-bit comparator, which digitizes the input referenced to an adjustable threshold value. This results in four independent serial sample streams of binary 1s and 0s, which are ORed together at rates up to 10 GHz. This single serial stream is then deserialized by a factor of 16 to create 16 signal lines at a rate of 622.5 MHz or lower for input to a high-speed digital processor assembly. The new design and corresponding hardware can be employed with a quad-photon counting detector capable of handling photon rates on the order of multi-gigaphotons per second, whereas prior art was only capable of handling a single input at 1/4 the flux rate. Additionally, the hardware edge-detection algorithm has provided the ability to process 3-10 higher photon flux rates than previously possible by removing the limitation that photoncounting detector output pulses on multiple channels being ORed not overlap. Now, only the leading edges of the pulses are required to not overlap. This new photon counting digitizer hardware architecture supports a universal front end for an optical communications receiver operating at data rates from kilobits to over one gigabit per second to meet increased mission data volume requirements.

Gin, Jonathan W.↗

Carbene Functionalization of Monolayer Tungsten Disulfide for Enhanced Quantum Emission

Semiconducting two-dimensional (2D) transition metal dichalcogenides (TMDs) are promising materials for an array of applications, ranging from conventional field-effect transistors, photodetectors, and light-emitting diodes to their more recent use in quantum photonic technologies. Chemical functionalization of 2D TMDs with organic ligands and adlayers provides an additional means for customizing their electronic and optical properties. While many pathways have been reported for the chemical functionalization of 2D TMDs, their frequent reliance on solution-based methods results in limited control over adlayer thickness and coverage, thus hindering utility in high-performance applications. Here, in this study, we describe the vapor-phase functionalization of a 2D TMD with carbene ligands, specifically tungsten disulfide (WS 2 ) with N-heterocyclic carbenes (NHCs), resulting in molecularly smooth, thin, and uniform adlayers. Reacting NHCs with monolayer WS 2 reduces the broad photoluminescence background observed at cryogenic temperatures by 58%, which facilitates the detection of single-photon emitters from strained monolayer WS 2 , as indicated by second order correlation values ( g (2) ) as low as 0.17 ± 0.07. Chemical characterization coupled with density functional theory calculations suggests that the NHC adlayer has a dual defect-passivation and doping effect on monolayer WS 2 that results in enhanced single-photon emission. Overall, this study establishes vapor-phase carbene functionalization as a homogeneous surface modification scheme for tailoring the quantum emission properties of semiconducting 2D TMDs.

N-heterocyclic carbenes↗

Femtosecond Photon-Counting Receiver

An optical correlation receiver is described that provides ultra-precise distance and/or time-pulse-width measurements even for weak (single photons) and short (femtosecond) optical signals. A new type of optical correlation receiver uses a fourth-order (intensity) interferometer to provide micron distance measurements even for weak (single photons) and short (femtosecond) optical signals. The optical correlator uses a low-noise-integrating detector that can resolve photon number. The correlation (range as a function of path delay) is calculated from the variance of the photon number of the difference of the optical signals on the two detectors. Our preliminary proof-of principle data (using a short-pulse diode laser transmitter) demonstrates tens of microns precision.

Photons↗

A hybrid coupler for directing quantum light emission with high radiative Purcell enhancement to a dielectric metasurface lens

Quantum photonic technologies such as quantum sensing, metrology, and simulation could be transformatively enabled by the availability of integrated single photon sources with high radiative rates and photon collection efficiencies. We address these challenges for quantum emitters formed from color center defect sites such as those in hexagonal boron nitride, which are promising candidates as single photon sources due to their bright, stable, polarized, and room temperature emission. We report design of a nanophotonic coupler from color center quantum emitters to a dielectric metasurface lens. The coupler is comprised of a hybrid plasmonic–dielectric resonator that achieves a large radiative Purcell enhancement and partial control of far-field radiation. We report radiative Purcell factors up to 285 and photon collection efficiencies up to 89% for a lossless metasurface, applying a continuous hyperboloidal phase-front. Our hybrid plasmonic–dielectric coupler interfacing two nanophotonic elements is a compound optical element, analogous to those found in microscope objective lenses, which combine multiple optical functions into a single component for improved performance.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Novel imaging technique for α-particles using a fast optical camera

A new imaging technique forα-particles using a fast optical camera focused on a thin scintillator is presented. Asα-particles interact in a thin layer of LYSO fast scintillator, they produce a localized flash of light. Furthermore, the light is collected with a lens to an intensified optical camera, Tpx3Cam, with single photon sensitivity and excellent spatial & temporal resolutions. The interactions of photons with the camera is reconstructed by means of a custom algorithm, capable of discriminating single photons using time and spatial information

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photon-to-Digital Converters for Neutron Imaging Instruments (Final Report)

Oak Ridge National Laboratory (ORNL) collaborated with the Université de Sherbrooke (UdeS) to design a modular and scalable tile of innovative digital photodetectors called Photon-to-Digital Converters (PDC) and the required subsystems to demonstrate the feasibility of large area single-photon detectors to support high-resolution, depth-of-interaction, fast neutron radiography based on scintillation detectors. The goal is to demonstrate the advantages of using PDC over conventional Silicon Photomultiplier (SiPM) for neutron imaging systems. The basic building blocks of analog SiPM and PDC are Single-Photon Avalanche Photodiodes (SPAD). The main difference between conventional SiPMs and PDCs, is in the fact that analog SiPMs sum the charge produced by individual SPAD passively, while in PDCs each SPAD is read out individually by an active electronic circuit. Hence, PDCs provide a direct photon-to-bit conversion where a logic “1” means that there was a detection in a given SPAD. Conversely, an analog SiPM requires a sophisticated preamplifier (current amplifiers or transimpedance amplifier) followed by a shaping amplifier and an analog-to-digital converter. Moreover, since the charge from each SPAD varies slightly, the passive sum of the analog SiPM will have signal fluctuations for the same amount of photon detected. This is one of many issues that is completely eliminated by individual one-to-one SPAD read out in PDCs. The large area required for scintillator readouts for neutron imaging is such that the output capacitance of a large area of SiPM arrays is very high. This creates a burden on the signal-to-noise optimization with respect to the power budget. For PDC, the power consumption is dictated by rate of the incident photon flux, or in photon-starved environments, the dark noise rate of the SPAD array. In other words, the power consumption in the absence of events is extremely low. Hence, the power consumption of a PDC read out system is much lower than its analog counterpart. Further, the large SiPM capacitance may introduce signal distortions on the scintillator fast rise or decay time with undesired effects on timing and pulse shape discrimination. The problem is absent in PDCs, as their readout is independent on device capacitance. UdeS is the world leader in 3D vertical integration of frontside illuminated SPAD arrays over CMOS readouts. These capabilities allow future production of “3D PDC” with maximum photosensitive fill factor and electronic functionalities tailored to the application. UdeS' vast knowledge of SPADs and CMOS design made the team an ideal collaborator in the development of large area high-resolution fast neutron radiography.

42 ENGINEERING↗