Search NASA⌕ Search

SEARCH · Search NASA

Results for “space weather”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Cabin Thermal Management Analysis for SuperTruck II Next-Generation Hybrid Electric Truck Design

In this article, we present a multistage, coupled thermal management simulation approach, informed by physical testing where available, to aid design decisions for PACCAR's SuperTruck II hybrid truck cabin concept. Focus areas include cabin insulation, battery sizing, and sleeper curtain position, as well as heating, ventilating, and air-conditioning (HVAC) component and accessory configurations, to maintain or improve thermal comfort while saving energy. The authors analyzed weather data and determined the national vehicle miles traveled weighted temperature and solar conditions for long-haul trucks. Example weather day profiles were selected to approximate the 5th and 95th percentile weighted conditions. A daylong drive cycle was developed to impose appropriate external wind conditions during rest and driving periods. Using the National Renewable Energy Laboratory's vehicle HVAC modeling and simulation tool VTCab, HVAC load design trade-off studies for the new truck geometry concept were completed. Parameters analyzed included effects of paint color, insulation, glass transmissivity, and curtain location. Simulation results helped with early design material selections for efficient cabin climate control. A detailed three-dimensional computer-aided engineering (CAE), computational fluid dynamics (CFD), radiation, and human physiology co-simulation, referred to in this article as CAE Thermal-CFD, was used to evaluate thermal comfort and energy impacts of diffuser configurations and air supply settings in driving and hoteling modes. Analysis revealed that it is more difficult to heat the cabin in hoteling mode during the winter than to cool the space in the summer. This seasonal load profile drives the requirement of additional energy storage for heating comfort. To determine the battery capacity requirement, multiday HVAC operation drive cycle simulations were then completed, showing that a 15-kWh battery would be required for HVAC operation during hoteling. Results helped reduce cabin thermal loads, determine component sizing requirements, and improve occupant comfort to save fuel and contribute to the economic viability of the hybrid system.

33 ADVANCED PROPULSION SYSTEMS↗

Evaluation and Optimization of Snow Albedo Scheme in Noah-MP Land Surface Model Using In Situ Spectral Observations in the Colorado Rockies

The Biosphere-Atmosphere Transfer Scheme (BATS) ground snow albedo algorithm is commonly used in land-surface models (LSM), weather forecasting and research applications. This study addresses key uncertainties in BATS simulated ground snow albedo within the Noah-MP LSM framework through evaluation and optimization of the Noah-MP BATS ground snow albedo formulation using 2-band (visible and near-infrared (NIR)) in situ albedo observations at Rocky Mountain field stations. The Noah-MP BATS ground snow albedo scheme is extremely sensitive to its input parameters. Namely, an ensemble generated by varying BATS input parameters within potentially plausible ranges provides an average daily range (maximum ensemble member minus minimum ensemble member) of ground snow albedo exceeding 0.45 in visible and NIR bands. Parameter optimization improves agreement between simulated and in situ observed ground snow albedo in visible, NIR and broadband spectrums. Importantly, optimized parameters result in reduced biases relative to observed fresh-snow albedo and better agreement with observed albedo decay. Our analysis across different sites supports that the optimized BATS ground snow albedo parameters are appropriate to transfer in space and time, at least within the region studied (the central-southern Rocky Mountains). The primary error source remaining after parameter optimization is that observed fresh-snow albedo is highly variable, particularly in the NIR spectrum, whereas BATS fresh-snow albedo is constant, an issue which requires further investigation. This study shows significant correlations between observed fresh-snow albedo and surface meteorological conditions (e.g., downward shortwave radiation and temperature) which can support future model development that attempts to include a time-varying formulation for fresh-snow albedo.

54 ENVIRONMENTAL SCIENCES↗

Impacts of active satellite sensors' low-level cloud detection limitations on cloud radiative forcing in the Arctic

Previous studies revealed that satellites sensors with the best detection capability identify 25 %–40 % and 0 %–25 % fewer clouds below 0.5 and between 0.5–1.0 km, respectively, over the Arctic. Quantifying the impacts of cloud detection limitations on the radiation flux are critical especially over the Arctic Ocean considering the dramatic changes in Arctic sea ice. In this study, the proxies of the space-based radar, CloudSat, and lidar, CALIPSO (Cloud-Aerosol Lidar and Infrared Pathfinder Satellite Observations), cloud masks are derived based on simulated radar reflectivity with QuickBeam and cloud optical thickness using retrieved cloud properties from surface-based radar and lidar during the Surface Heat Budget of the Arctic Ocean (SHEBA) experiment. Limitations in low-level cloud detection by the space-based active sensors, and the impact of these limitations on the radiation fluxes at the surface and the top of the atmosphere (TOA), are estimated with radiative transfer model Streamer. The results show that the combined CloudSat and CALIPSO product generally detects all clouds above 1 km, while detecting 25 % (9 %) fewer in absolute values below 600 m (600 m to 1 km) than surface observations. These detection limitations lead to uncertainties in the monthly mean cloud radiative forcing (CRF), with maximum absolute monthly mean values of 2.5 and 3.4 Wm –2 at the surface and TOA, respectively. Cloud information from only CALIPSO or CloudSat lead to larger cloud detection differences compared to the surface observations and larger CRF uncertainties with absolute monthly means larger than 10.0 Wm –2 at the surface and TOA. The uncertainties for individual cases are larger – up to 30 Wm –2 . These uncertainties need to be considered when radiation flux products from CloudSat and CALIPSO are used in climate and weather studies.

54 ENVIRONMENTAL SCIENCES↗

Analysis of Space-Conditioning Loads in Commercial Buildings

Space conditioning end-uses, which include heating, cooling, and ventilation, represent a significant fraction of commercial building energy use, with a wide variety of heating and cooling technology options available in the market. In the interest of improving the overall efficiency of heating, ventilation and air-conditioning (HVAC) technologies, governments, utilities and private sector entities have implemented a variety of market transformation policies that aim to influence consumer purchase decisions. To evaluate the costs and benefits of such programs, analysts typically postulate a hypothetical default equipment choice, and compare it to one that provides comparable service with lower energy and/or power use. The corresponding reduced operating cost provides a benefit that offsets the potential higher cost of improved efficiency. Typically, life-cycle cost or cash-flow analyses are used to quantify the net economic benefit. These analyses require the capability to assess how a given equipment design would perform across a broad range of characteristics, both of the building and of the local weather. While these assessments can be performed using customized building simulations, it is generally not practical to develop and validate detailed building simulation code to cover all the potential variations of equipment design and installation. An alternative, and somewhat simpler, approach is to solely use detailed building simulations to generate time series of heating and cooling loads in commercial buildings. These loads can then be used as input to more detailed, stand-alone engineering models that simulate HVAC system performance under different equipment designs. This approach was used to evaluate a range of high-efficiency commercial packaged air conditioner design options for the Department of Energy’s Appliance and Equipment Standards Program (DOE-EERE 2015). While there may be some loss of precision relative to full simulation, the accuracy of this approach is sufficient for practical applications of cost-benefit analysis. This report describes the development of a database of commercial building heating and cooling loads, generated using the EnergyPlus software package, a whole building energy use model supported by the Department of Energy (DOE-EERE 2020a). EnergyPlus takes as input a set of configuration files that describe the building itself (size, zoning, envelope characteristics, etc.) and the various systems within it (HVAC, lighting, water heating, etc.). This analysis uses a publicly available collection of commercial reference buildings (CRB), comprised of sixteen building types and three vintages (DOE-EERE 2020b; Deru et al 2011). Each building is simulated in eighteen different locations, covering a wide range of climatic conditions. The prototype building description files assign the type of HVAC equipment used, and capacities across climate zones.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Arctic Observing Experiment (AOX) Field Campaign Report

Our ability to understand and predict weather and climate requires an accurate observing network. One of the pillars of this network is the observation of the fundamental meteorological parameters: temperature, air pressure, and wind. We plan to assess our ability to measure these parameters for the polar regions during the Arctic Observing Experiment (AOX, Figure 1) to support the International Arctic Buoy Programme (IABP), the Arctic Observing Network (AON), the International Program for Antarctic Buoys (IPAB), and the Southern Ocean Observing System (SOOS). Accurate temperature measurements are also necessary to validate and improve satellite measurements of surface temperature across the Arctic.

54 ENVIRONMENTAL SCIENCES↗

Organic carbon enables the biotic engineering of beneficial soil structure in Profundihumic and Haplic Ferralsols

We investigated how organic matter may, directly and indirectly, modify the porosity of Ferralsols, that is, deeply weathered soils of the tropics and subtropics. Although empirical and anecdotal evidence suggests that organic matter accumulation may increase porosity, a mechanistic understanding of the processes underlying this beneficial effect is lacking, especially so for Ferralsols. To achieve our end, we leveraged the fact that the Profundihumic qualifier of Ferralsols (PF) is distinguished from Haplic Ferralsols (HF) by both a much larger average carbon content in the first 1 m of soil depth (19 kg C m -3 in PF vs. 10 kg C m -3 in HF) and a significantly lower bulk density (1.05 ± 0.08 kg L -1 in PF vs. 1.21 ± 0.05 kg L -1 in HF). Through exhaustive modelling of carbon – bulk density relationships, we demonstrate that the lower bulk density of PF cannot be satisfactorily explained by a simple dilution effect. Rather, we found that bulk density correlated with carbon content when combined with carbon: nitrogen ratio (r 2 = 0.51), black carbon content (r 2 = 0.75), and Δ 14 C (r 2 =0.81). Total pore space was greater in PF (61± 3%) than in HF (55 ± 2%), but x-ray computed tomography revealed that pore space inside soil aggregates of 4–5 mm diameter does not vary between the studied Ferralsols. We further observed nearly twice as many roots and burrows in PF compared with HF. We thus infer that the mechanism responsible for the increase in porosity is most likely an enhancement of resource availability (e.g., energy, carbon, and nutrients) for the organisms (earthworms, ants, termites, etc.) that physically displace soil particles and promote soil aggregation. As a result of increased resource availability, soil organisms can create especially the mesoscale structural soil features necessary for unrestricted water flow and rapid gas exchange. In conclusion, this insight paves the way for the development of land management technologies to optimize the physical shape and capacity of the soil bioreactor.

54 ENVIRONMENTAL SCIENCES↗

Staying cool: The development of India's pioneering energy efficiency policy for chillers

Abstract Chillers are the key energy‐consuming piece of equipment in most large space cooling systems. They can account for more than 40% of total energy consumption in any typical commercial building and in specific industrial building installations depending on the product and process. With climate change driving rapidly rising demand for commercial and industrial cooling, especially in emerging economies, energy efficiency policies for chillers are crucial to moderate future electricity demand and thereby minimize greenhouse gas emissions. However, most developing and emerging economies lack energy efficiency policies for this significant and growing cooling equipment sector. India recently announced new energy efficiency policies for chillers, projected to avoid 28 TWh of electricity consumption and 23 million tons of CO 2 emissions cumulatively through 2030. This article presents a case study of the unique challenges and solutions required to design a new energy efficiency policy for chillers in India. First, the energy consumed in chiller systems is sensitive to building occupancy, load changes, seasonal variations, operation and maintenance, and climatic conditions. In order to address these sensitivities, the chiller testing standard in India factors local weather and temperature conditions into energy performance ratings to account for these sensitivities. Further, every large chiller is a customized product, therefore developing a viable policy and implementation process required collaboration with international and national experts in standardization, manufacturers, building consultants, and testing laboratories. This article is categorized under: Energy Efficiency > Economics and Policy Solar Energy: Thermal ‐‐> Climate and Environment

Mukherjee, P. K.↗

How will United States commercial building energy use be impacted by IPCC climate scenarios?

Climate change and anthropogenically-forced shift of weather in the future will impact energy use and resilience of both the built environment and the electric grid. The aim of this analysis is to understand how future climate scenarios will impact electricity and natural gas use of commercial buildings in the United States. Here, this study analyzes this impact for 2030, 2045, and 2100 using Representative Concentration Pathways (RCP) scenarios defined in Intergovernmental Panel on Climate Change (IPCC) Assessment Report 5. The large, gridded simulation of meteorological variables for RCPs 2.6, 4.5, 6.0, and 8.5 are selected and downscaled to make available hourly Future Meteorological Year (FMY) weather files for use and improvement in subsequent studies. High performance computing resources use these FMYs to simulate commercial prototype buildings in every American Society of Heating, Refrigeration, and Air Conditioning Engineers (ASHRAE) climate zone of the United States (US), and results are scaled to nation-wide energy use using conditioned floor area multipliers. The analysis is conducted without speculating the physical and performance traits of future buildings or the grid characteristics. This analysis quantifies the impact of climate change on source electrical and natural gas usage for commercial buildings in the United States over the next 80 years. If US commercial floorspace remained constant, total energy use by 2100 is predicted between an 1.75% decrease under the greatest emission scenario (8.5) and a 1.76% increase under the lowest emission scenario (2.6). When adjusted for anticipated urban growth by 2100, the predicted range is 65% increase (8.5) and 71% increase (2.6). Under a global temperature rise climate scenario, the warmest US climate zones will see a large increases in electricity use derived from space cooling while the coldest US climate zones will see significant decreases in natural gas use caused by the decrease in heating necessary. While climate change may ultimately require adaptations of the built environment to withstand its effects and because the United States is a country that requires more heating than cooling, from a building energy perspective, climate change (average temperature rise) is a net energy saver for the United States.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Summertime Post-Cold-Frontal Marine Stratocumulus Transition Processes over the Eastern North Atlantic

Abstract Marine boundary layer (MBL) cloud morphology associated with two summertime cold fronts over the eastern North Atlantic (ENA) is investigated using high-resolution simulations from the Weather Research and Forecasting (WRF) Model and observations from the Atmospheric Radiation Measurement (ARM) ENA Climate Research Facility. Lagrangian trajectories are used to study the evolution of post-cold-frontal MBL clouds from solid stratocumulus to broken cumulus. Clouds within specified domains in the vicinity of transitions are classified according to their degree of decoupling, and cloud-base and cloud-top breakup processes are evaluated. The Lagrangian derivative of the surface latent heat flux is found to be strongly correlated with that of the cloud fraction at cloud base in the simulations. Cloud-top entrainment instability (CTEI) is shown to operate only in the decoupled MBL. A new indicator of inversion strength at cloud top that employs the vertical gradients of equivalent potential temperature and saturation equivalent potential temperature, which can be computed directly from soundings, is proposed as an alternative to CTEI. Overall, results suggest that the deepening–warming hypothesis suggested by Bretherton and Wyant explains many of the characteristics of the summertime postfrontal MBL evolution of cloud structure over the ENA, thereby widening the phase space over which the hypothesis may be applied. A subset of the deepening–warming hypothesis involving warming initially dominating over moistening is proposed. It is postulated that changes in climate change–induced modifications in cold-frontal structure over the ENA may be accompanied by coincident changes in the location and timing of MBL cloud transitions in the post-cold-frontal environment.

54 ENVIRONMENTAL SCIENCES↗

Feasibility Analysis for the Use of Retrofitted Air-Conditioners Using Thermal Energy Storage (TES) for High Ambient Temperature (HAT) Countries

In high ambient temperature (HAT) countries, summer temperatures exceed 35℃, degrading the performance of air-conditioning systems and straining power grids. In this paper, a feasibility analysis was conducted to investigate potential savings during the peak using latent Thermal Energy Storage (TES) at near room phase-change temperatures, replacing condensers, thus, minimizing temperature lifts. Weather data, building loads, and baseline air-conditioning systems data were gathered for Dubai. A transient vapor-compression model in Modelica was used to compare the COP, total power input and cooling capacity of the air-conditioner at peak hours when ambient temperatures range between 35 – 45 ⁰C versus the TES-Phase-Change Material (PCM) melting temperatures from 22 – 28⁰C. The results indicate that the TES-PCM can enhance the system COP at the peak by a factor 1.4 and 2 for during for outdoor temperatures of 35 – 40⁰C, and 40 – 45⁰C, respectively. Lower melting temperature PCMs were able to reduce the required power input by 30-50%, with more savings occurring at higher temperature days. On the other hand, higher temperature PCMs enhancements were minimal especially at outdoor ambient temperatures ranging between 35 – 40⁰C. Improvements to the cooling capacity range from 8 – 18 % for the outdoor temperature range of 35 – 45 ⁰C. An economic analysis was conducted to find the potential saving in utility costs for 30%, 60%, and 90% of the space cooling demands of Dubai, and find the trade-off points between utility savings and cost of PCM-TES implementation. If the peak loads are to be shifted by 6 hours daily, the percentage utility savings for the city is 18%. Using estimated costs of the PCM-TES, ranging from $200-500/kWh, the daily load shifting hours were estimated to range from 4 hours at the lowest cost systems to 2.5 hours at the highest costs.

25 ENERGY STORAGE↗

Porting a fast-running wildfire plume model for use in national security and climate applications

In this project, the code for the fast-running Freitas wildfire plume model was successfully ported into the NARAC system, creating an operations-ready capability for predicting the transport of hazardous smoke from large wildfires. “Porting” refers to copying a section of code from one software package to another while accounting for unique dependencies in each software package. In this case, the code was ported from the Weather Research and Forecasting (WRF) Model, which is used extensively by the project team. To verify correct implementation, model results from the updated NARAC system were compared to those from WRF and the High-Resolution Rapid Refresh (HRRR) forecast model, which also employs the Freitas scheme. The NARAC User Interface (UI) and code documentation were also updated to include the new wildfire plume option, and a wildfire case was added to the NARAC test suite. The code was used in a real-time, semi-operational setup to predict smoke transport during the Cerro Pelado fire near Los Alamos National Laboratory in May 2022. The Freitas plume model was also tested for LLNL climate applications. Although the code was not ported into the Energy Exascale Earth System Model (E3SM), it was tested offline using E3SM atmospheric inputs, and results were compared to existing high-resolution plume predictions from large-eddy simulations in WRF. The code implementation and testing completed during this project will enable future work predicting smoke transport from large wildfires in LLNL national security and climate mission spaces.

54 ENVIRONMENTAL SCIENCES↗

Dependencies of Simulated Convective Cell and System Growth Biases on Atmospheric Instability and Model Resolution

Abstract This study evaluates convective cell properties and their relationships with convective and stratiform rainfall within a season‐long convection‐permitting weather research and forecasting simulation over central Argentina using radar, satellite, and radiosonde measurements from the RELAMPAGO‐CACTI field campaign. The simulation slightly underestimates radar‐estimated rainfall over the ∼3.5‐month evaluation period but underestimates stratiform rainfall by 46% and overestimates convective rainfall by 43%. As convective available potential energy (CAPE) increases, the convective rainfall overestimation decreases, but the stratiform rainfall underestimation increases such that the contribution of convective to total rainfall remains constantly high biased by ∼26%. Overestimated convective rainfall arises from the simulation generating 2.6 times more precipitating convective cells (14,299) than observed by radar (5,662) despite similar observed and simulated cell growth processes, with relatively wide cells contributing mostly to excessive convective rainfall. Relatively shallow cells, typically reaching heights of 4–7 km, contribute most to the cell number bias. This cell number bias increases as CAPE decreases, potentially because cells and their updrafts become narrower and more under‐resolved as CAPE decreases. The gross overproduction of precipitating shallow cells leads to overly efficient precipitation and inadequate detrainment of ice aloft, thereby diminishing the formation of robust stratiform rainfall regions. Decreasing model horizontal grid spacing from 3 to 1 or 0.333 km for low (<300 J kg −1 ) and high CAPE (>1,000 J kg −1 ) cases results in minimal change to cell number, depth, and convective‐to‐stratiform partitioning biases. This suggests that improving prediction of these convective properties depends on factors beyond solely increasing model resolution.

54 ENVIRONMENTAL SCIENCES↗

Calibration of cloud and aerosol related parameters for solar irradiance forecasts in WRF-solar

Model parameters are a major source of uncertainty in numerical weather prediction. Recently, the Weather Research and Forecasting model with Solar extensions (WRF-Solar) has been upgraded by enhancing the treatment of sub-grid scale cloud and aerosols with augmentations of a sub-grid scale cloud scheme (CLD3) and an upgraded aerosol-aware Thompson-Eidhammer scheme (TE14). However, the value of model parameters associated with these parameterizations are assigned based on limited measurements or theoretical calculations. Calibrating the most sensitive parameters has the potential to improve solar irradiance predictions. Here, we adopted a multiobjective surrogate-based optimization (SBO) framework to calibrate nine parameters used in CLD3 and TE14 that lead to the largest sensitivity in simulated irradiance. The normalized mean-absolute-error (NMAE) of global horizontal irradiance (GHI) and direct normal irradiance (DNI) are minimized by calibrating WRF-Solar over two regions including the Southern Great Plains (SGP) and Central California, in order to focus on parameter calibration under cloudy conditions with different aerosol loading. The results show that generalized linear model (GLM)-based surrogate models approximate physical models well, particularly when the third order and three-way interaction terms are considered. The SBO framework efficiently searches the parameter space for optimal solutions with less computational costs than directly calibrating the physical model. We first calibrate CLD3 parameters over the less-polluted SGP region. Optimized CLD3 parameters alone result in NMAE reduction by 14% for the site-mean and up to 33% for individual cases over the SGP region. With further calibration of TE14 parameters over the Central California during active fire periods, the optimized parameters lead to over 20% reductions of NMAE. Our investigation reveals, however, that optimizing TE14 has a limited impact on irradiance simulations under less-polluted conditions in the SGP.

14 SOLAR ENERGY↗

Field Validation of a Grid-Interactive Efficient Building Software Solution

The U.S. General Services Administration's (GSA's) Green Proving Ground (GPG) program, in partnership with the National Laboratory of the Rockies (NLR), completed a field study of a Grid-Interactive Efficient Buildings (GEB) software solution. The study focused on a single testbed facility to test the GEB functionality of the software solution, along with other features. The testbed facility - a courthouse - is a common building type in GSA's vast building portfolio, offering potentially impactful findings on a scalable level. The study evaluated Prescriptive Data's technology, Nantum OS, a connected building operating system ("GEB Solution") which aggregates multiple sources of previously siloed building data and combines that data with external sources, such as weather information or utility signals, into a single integrated platform. A GEB Solution is a type of Energy Management Information System (EMIS). EMIS is defined as a system of devices, data services, and software applications that communicates with any building system or third-party data source to aggregate and transform data into new capabilities to aid in the optimization of energy use at the building, campus, or agency level. This specific GEB Solution is an EMIS with ASO, automated system optimization, offering supervisory control of certain aspects of the Building Automation System (BAS). Multiple features were evaluated including, but not limited to, Continuous Demand Management to avoid setting new monthly kilowatt (kW) peaks, energy efficiency for reduction of kilowatt hours (kWh) and natural gas consumption, and automated demand response (ADR) for purposes of lowering demand during a utility called Demand Response (DR) event. The testbed facility was the Foley Federal Building and US Courthouse ("Foley Federal Building") located in Las Vegas, NV. This is a 209,496 sq. ft. building constructed in the 1960s with major renovations in 2004. The facility was a good candidate due to the large prevalence of office and courthouse spaces in the GSA portfolio of buildings. It also has many features which allow integration into and control of the building and a strong facilities team to assist with the study. Quantitative and qualitative performance objectives were developed using GSA's GPG GEB project template along with input from the vendor and building facility staff; these are outlined in Table 1. The quantitative performance objectives focused on continuous demand management, energy efficiency, and automated demand response. The qualitative performance objectives focused on the ease of installation and commissioning as well as the operability of the GEB solution. Other performance metrics that are reported on include carbon reduction, cost effectiveness, and occupant acceptance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Air-coupled tsunamis generated from impacts and airbursts: Our understanding before Hunga-Tonga Hunga-Ha'apai

The effort to prevent or mitigate the effects of an impact on Earth is known as planetary defense. A significant component of planetary defense research involves risk assessment. Much of our understanding of the risk from near-Earth objects comes from the geologic record in the form of impact craters, but not all asteroid impacts are crater-forming events. Small asteroids explode before reaching the surface, generating an airburst, and most impacts into the ocean do not penetrate the water to form a crater in the sea floor. The risk from these non-crater-forming ocean impacts and airbursts is difficult to quantify and represents a significant uncertainty in our assessment of the overall threat. We are currently working to better understand impact scenarios that can generate dangerous tsunamis. One of the suggested mechanisms for the production of asteroid–generated tsunamis is by direct coupling of the pressure wave to the water, analogous to the means by which a moving weather front can generate a meteotsunami. To test this hypothesis, we ran a series of airburst simulations and provided time-resolved pressure and wind profiles to use as source functions for tsunami models. We used the CTH hydrocode to model the various airburst scenarios to compare to the results of other simulations and provide time dependent boundary conditions as input to shallow-water wave propagation codes. The strongest and most destructive meteotsunamis are generated by atmospheric pressure oscillations with amplitudes of only a few hPa1 (mbar), corresponding to changes in sea level of a few cm. The resulting wave is strongest when there is a resonance between the ocean and the atmospheric forcing. A Proudman resonance takes place when the atmospheric disturbance’s translational speed (U) equals the longwave phase speed $\sqrt{gh}$ of shallow water wave. Coupling is strongest when the Froude number (Fr=U/c) is unity. A weather front propagates much slower than the speed of sound, so meteotsunamis are most common and dangerous in shallow bodies of water such as the Mediterranean Sea or Lake Michigan. By contrast, the blast wave from an airburst or crater-forming impact propagates at a speed faster than a tsunami in the deepest ocean, and a Proudman resonance cannot be achieved even though the overpressures are orders of magnitude greater. However, blast wave profiles are N-waves in which a sharp shock wave leading to overpressure is followed by a more gradual rarefaction to a much longer-duration underpressure phase. Even though the blast outruns the water wave it is forcing, the tsunami should continue to be driven by the out-of-resonance gradient associated with the suction phase, which may depend strongly on the details of the airburst or impact scenario. The open question is whether there are any conditions under which such an airburst-driven tsunami can be dangerous enough to contribute to the overall impact risk. We have also identified other potential mechanisms for airburst-generated tsunamis: 1) reaction force at the surface from the plume ejected into space, which carries significant momentum, 2) expanding toroidal vortices at the surface, which travel more slowly than the shock wave and can generate a Proudman resonance in relatively shallow ocean (such as continental shelf), and 3) steam explosion from seawater ablation by a “Type II” (Libyan Desert Glass-type) airburst in which the hot vapor jet descends to the surface. On January 15, 2022, the Hunga-Tonga Hunga-Ha’apai volcano, located approximately 60 km north of Tongatapu, the main island of Tonga, violently erupted with a powerful explosion, culminating the period of volcanic activity that started in December of 2021. This event and resulting tsunamis provided an existence proof for the air pressure wave coupling mechanism we proposed. It also suggests that it can be stronger and more significant over much greater distances than we contemplated, leading to global tsunamis associated with impact events on land as well as in the water. Large atmospheric explosions generate global Lamb waves with larger amplitudes, longer periods, and slower speeds than the local and regional blast waves we modeled prior to that event. This paper reviews our analysis and modeling of airburst-driven tsunamis prior to the 2022 Hunga-Tonga Hunga-Ha’apai tsunami, which was the subject of two presentations at the 2023 Planetary Defense Conference and is the subject of another paper currently in preparation.

54 ENVIRONMENTAL SCIENCES↗

Hybrid Heat Pump Controls: Conventional Dual Fuel versus Seamlessly Fuel Flexible Heat Pump

This paper compares the performance of a novel seamlessly fuel flexible heat pump (SFFHP) and conventional dual fuel heat pump (DFHP) for space heating. The conventional dual fuel systems either run on the gas furnace or electric heat pump at any given moment, as a comparison, the proposed seamlessly fuel flexible heat pump simultaneously consumes gas and electricity by continuously optimizing the proportion of each. The process air flows across the heat pump condenser first and then flows across the furnace coil, therefore, the heat pump temperature lift is reduced. SFFHP delivers energy savings by allowing each subsystem, i.e., gas furnace and electric heat pump, to operate where it performs best.For DFHP, two operation control strategies, i.e., non-restricted control and restricted control, are available on market. For the non-restricted mode, the thermostat has a switching temperature-programmed according to the balancing point of heating load and capacity curve. Heat pump operates above the switching temperature, while the furnace takes over under the switching temperature. For the restricted control, the compressor of a heat pump is disabled below a predefined lockout outdoor temperature to let the furnace take over. For SFFHP, a model predictive control strategy is developed to continuously adjust the capacities of the electric heat pump and gas furnace based on the foreseen weather data, utility price signals, and marginal grid emission signals with the goal of minimizing the utility cost and CO2 emission while guaranteeing comfort requirements.In this paper, DFHP and SFFHP are simulated using high-fidelity heat pump performance curves generated from DOE/ORNL heat pump design model. Performance comparison of DFHP and SFFHP during 2019-2020 heating season in Los Angeles shows that SFFHP with model predictive control achieves 23% utility cost reduction and 17 % CO2 emission reduction. Case studies demonstrate that SFFHP can deliver significant reductions in peak demand, utility cost, and CO2 emission. As a result, SFFHP can deliver superior benefits for utility cost reduction and CO2 emission reduction over conventional dual fuel heat pump.

Li, Zhenning↗

Turbulence-Resolving Simulations of Hurricane Laura (2020): Insights Into Extreme Winds and Eyewall Turbulence

Extreme weather events pose significant risks to coastal and offshore energy infrastructure. In this work, we investigate the structure of mean winds and turbulence near the surface ( z < 300 m) that occurred during Hurricane Laura in 2020 on the US Gulf Coast. To this end, we perform turbulence-resolving simulations (..delta..x = 33.33 m) that encompass the entire eyewall of Hurricane Laura by introducing a novel method that we will refer to as Moving-Mesoscale to Static-LES Integrated Coupling (MOSAIC). The simulation results are validated against surface, boundary-layer, and mid-tropospheric observations. Our analysis of the extreme wind conditions near the surface indicates that the mean wind and turbulence profiles vary greatly at and near the eyewall, resulting in extreme values of mean wind speed (U > 50 m * s-1) and turbulence kinetic energy (k ~ 50 m2 * s-2) at altitudes above 50 m . To investigate in detail the nature of turbulence within the eyewall of the storm, we conduct higher-resolution simulations (..delta..x = 11.11 m) of a portion of the hurricane. We provide a comprehensive statistical description of turbulence in the eyewall region, highlighting the need to employ ..delta..x ~ 10 m grid spacing to capture the integral length-scales near the surface, second- and higher-order central moments (i.e., skewness and kurtosis), and spectral coherence in the flow accurately. These numerical simulations provide the most detailed description of mean winds and turbulent conditions within the eyewall of a historical tropical cyclone to date, illustrating how high-resolution simulations can enhance limited turbulence measurements in hurricanes and giving insight into the extreme conditions threatening offshore and coastal infrastructure.

17 WIND ENERGY↗

A Comparison of Pre‐Construction and Operational Wake Loss Estimates for Land‐Based Wind Plants

The overall bias between pre‐construction energy yield assessment (EYA) estimates of wind plant energy production and the achieved operational production is improving in the wind industry, but uncertainty remains high for individual wind plants. Wake effects within wind plants are one of the largest sources of energy loss considered in the EYA process, and previous work shows wake loss estimates to be a major source of disagreement among wind energy consultants who perform EYAs. To better understand the accuracy of wake loss predictions, we compare overall operational wake loss estimates based on supervisory control and data acquisition data to pre‐construction estimates provided by six wind energy consultants for five land‐based wind plants in North America. By augmenting existing approaches for quantifying operational wake losses, we estimate wake losses during the period of record for which operational data are available as well as the expected long‐term wake losses, based on historical reanalysis weather data, to which the EYA estimates are compared. To account for power variations at different turbine locations caused by terrain‐induced wind resource heterogeneity, we correct the operational wake loss estimates using predicted freestream wind speed variations from the Wind Systems Engineering Reynolds‐averaged Navier–Stokes (RANS) tool. We identify long‐term corrected operational wake losses between 1.9% and 6.4% for the five plants, with a mean loss of 4%. For the project deemed most acceptable for operational wake loss assessment, which is located in the simplest terrain and isolated from neighboring plants, the mean EYA wake loss estimate is within 0.7 percentage points of the operational value of 6.4%. For most of the remaining plants, results suggest that wake losses are generally overpredicted by 2.6–6.3 percentage points. However, operational wake losses may be underestimated for many of these projects because of spatial wind resource variations not captured by the RANS model, external wake effects that are unaccounted for in the estimation process, and wind plant blockage effects. To better understand factors that contribute to the observed wake losses, we investigate operational wake losses as a function of wind direction and wind speed. As expected, wake losses are generally concentrated near wind directions that are aligned with rows of closely spaced turbines and at below‐rated wind speeds; however, for some projects, the energy produced by the wind plant exceeds the estimated potential energy of the plant without wake interactions for certain wind directions and wind speeds, suggesting inaccurate assumptions in the wake loss estimation method for those plants. Lastly, we compare predicted and operational wake losses for individual wind turbines, finding that even when overall wake losses are predicted accurately, large uncertainty exists at the turbine level.

17 WIND ENERGY↗