Search NASA⌕ Search

SEARCH · Search NASA

Results for “statistical segmentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Characterization of mammographic masses based on level set segmentation with new image features and patient information

Computer-aided diagnosis (CAD) for characterization of mammographic masses as malignant or benign has the potential to assist radiologists in reducing the biopsy rate without increasing false negatives. The purpose of this study was to develop an automated method for mammographic mass segmentation and explore new image based features in combination with patient information in order to improve the performance of mass characterization. The authors' previous CAD system, which used the active contour segmentation, and morphological, textural, and spiculation features, has achieved promising results in mass characterization. The new CAD system is based on the level set method and includes two new types of image features related to the presence of microcalcifications with the mass and abruptness of the mass margin, and patient age. A linear discriminant analysis (LDA) classifier with stepwise feature selection was used to merge the extracted features into a classification score. The classification accuracy was evaluated using the area under the receiver operating characteristic curve. The authors' primary data set consisted of 427 biopsy-proven masses (200 malignant and 227 benign) in 909 regions of interest (ROIs) (451 malignant and 458 benign) from multiple mammographic views. Leave-one-case-out resampling was used for training and testing. The new CAD system based on the level set segmentation and the new mammographic feature space achieved a view-based A{sub z} value of 0.83{+-}0.01. The improvement compared to the previous CAD system was statistically significant (p=0.02). When patient age was included in the new CAD system, view-based and case-based A{sub z} values were 0.85{+-}0.01 and 0.87{+-}0.02, respectively. The study also demonstrated the consistency of the newly developed CAD system by evaluating the statistics of the weights of the LDA classifiers in leave-one-case-out classification. Finally, an independent test on the publicly available digital database for screening mammography with 132 benign and 197 malignant ROIs containing masses achieved a view-based A{sub z} value of 0.84{+-}0.02.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MO-G-BRE-04: Automatic Verification of Daily Treatment Deliveries and Generation of Daily Treatment Reports for a MR Image-Guided Treatment Machine

Purpose: Two aims of this work were to develop a method to automatically verify treatment delivery accuracy immediately after patient treatment and to develop a comprehensive daily treatment report to provide all required information for daily MR-IGRT review. Methods: After systematically analyzing the requirements for treatment delivery verification and understanding the available information from a novel MR-IGRT treatment machine, we designed a method to use 1) treatment plan files, 2) delivery log files, and 3) dosimetric calibration information to verify the accuracy and completeness of daily treatment deliveries. The method verifies the correctness of delivered treatment plans and beams, beam segments, and for each segment, the beam-on time and MLC leaf positions. Composite primary fluence maps are calculated from the MLC leaf positions and the beam-on time. Error statistics are calculated on the fluence difference maps between the plan and the delivery. We also designed the daily treatment delivery report by including all required information for MR-IGRT and physics weekly review - the plan and treatment fraction information, dose verification information, daily patient setup screen captures, and the treatment delivery verification results. Results: The parameters in the log files (e.g. MLC positions) were independently verified and deemed accurate and trustable. A computer program was developed to implement the automatic delivery verification and daily report generation. The program was tested and clinically commissioned with sufficient IMRT and 3D treatment delivery data. The final version has been integrated into a commercial MR-IGRT treatment delivery system. Conclusion: A method was developed to automatically verify MR-IGRT treatment deliveries and generate daily treatment reports. Already in clinical use since December 2013, the system is able to facilitate delivery error detection, and expedite physician daily IGRT review and physicist weekly chart review.

60 APPLIED LIFE SCIENCES↗

Establishing homologies in protein sequences

Computer-based statistical techniques used to determine homologies between proteins occurring in different species are reviewed. The technique is based on comparison of two protein sequences, either by relating all segments of a given length in one sequence to all segments of the second or by finding the best alignment of the two sequences. Approaches discussed include selection using printed tabulations, identification of very similar sequences, and computer searches of a database. The use of the SEARCH, RELATE, and ALIGN programs (Dayhoff, 1979) is explained; sample data are presented in graphs, diagrams, and tables and the construction of scoring matrices is considered.

Dayhoff, M. O.↗

Real-time verification of multileaf collimator-driven radiotherapy using a novel optical attenuation-based fluence monitor

Purpose: Multileaf collimator (MLC)-driven conformal radiotherapy modalities [e.g., such as intensity-modulated radiotherapy (IMRT), intensity-modulated arc therapy, and stereotactic body radiotherapy] are more subject to delivery errors and dose calculation inaccuracies than standard modalities. Fluence monitoring during treatment delivery could reduce such errors by allowing an independent interface to quantify and assess measured difference between the delivered and planned treatment administration. We developed an optical attenuation-based detector to monitor fluence for the on-line quality control of radiotherapy delivery. The purpose of the current study was to develop the theoretical background of the invention and to evaluate the detector's performance both statistically and in clinical situations. Methods: We aligned 60 27-cm scintillating fibers coupled to a photodetector via clear optical fibers in the direction of motion of each of the 60 leaf pairs of a 120 leaves Millenium MLC on a Varian Clinac iX. We developed a theoretical model to predict the intensity of light collected on each side of the scintillating fibers when placed under radiation fields of varying sizes, intensities, and positions. The model showed that both the central position of the radiation field on the fiber (x{sub c}) and the integral fluence passing through the fiber ({Phi}{sub int}) could be assessed independently in a single measurement. We evaluated the performance of the prototype by (1) measuring the intrinsic variation of the measured values of x{sub c} and {Phi}{sub int}, (2) measuring the impact on the measured values of x{sub c} and {Phi}{sub int} of random leaf positioning errors introduced into IMRT fields, and (3) comparing the predicted values of x{sub c} and {Phi}{sub int} calculated with the treatment planning software to the measured values of x{sub c} and {Phi}{sub int} in order to assess the predictive effectiveness of the developed theoretical model. Results: We observed a very low intrinsic dispersion, dominated by Poisson statistics, for both x{sub c} (standard deviations of less than 1 mm) and {Phi}{sub int} (standard deviations of less than 0.20%). When confronted with random leaf positioning errors from IMRT segments, {Phi}{sub int} was highly sensitive to single leaf positioning errors as small as 1 mm at isocenter, while x{sub c} was sensitive to leaf pair translation errors of at least 2 mm at isocenter. Owing to the uncertainties in the doses calculated in regions of high perpendicular dose gradients, the measured values of x{sub c} and {Phi}{sub int} deviated from the predicted values of x{sub c} and {Phi}{sub int} by a mean of 1.3 mm and 2.6%, respectively. Conclusion: Our study showed that an optical attenuation-based detector can be used to effectively monitor integral fluence during radiotherapy delivery. The performance of such a system would enable real-time quality control of the incident fluence in current MLC-driven treatments such as IMRT and future adaptive radiotherapy procedures where new treatment plans will have to be delivered without passing thru the current standard quality control chain.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low Cerebral Blood Volume Identifies Poor Outcome in Stent Retriever Thrombectomy

BackgroundMechanical thrombectomy (MT) is an efficient treatment of acute stroke caused by large-vessel occlusion. We evaluated the factors predicting poor clinical outcome (3-month modified Rankin Scale, mRS >2) although MT performed with modern stent retrievers.MethodsWe prospectively collected the clinical and imaging data of 105 consecutive anterior circulation stroke patients who underwent MT after multimodal CT imaging. Patients with occlusion of the internal carotid artery and/or middle cerebral artery up to the M2 segment were included. We recorded baseline clinical, procedural and imaging variables, technical outcome, 24-h imaging outcome and the clinical outcome. Differences between the groups were studied with appropriate statistical tests and binary logistic regression analysis.ResultsLow cerebral blood volume Alberta stroke program early CT score (CBV-ASPECTS) was associated with poor clinical outcome (median 7 vs. 9, p = 0.01). Lower collateral score (CS) significantly predicted poor outcome in regression modelling with CS = 0 increasing the odds of poor outcome 4.4-fold compared to CS = 3 (95% CI 1.27–15.5, p = 0.02). Lower CBV-ASPECTS significantly predicted poor clinical outcome among those with moderate or severe stroke (OR 0.82, 95% CI 0.68–1, p = 0.05) or poor collateral circulation (CS 0–1, OR 0.66, 95% CI 0.48–0.90, p = 0.009) but not among those with mild strokes or good collaterals.ConclusionsCBV-ASPECTS estimating infarct core is a significant predictor of poor clinical outcome among anterior circulation stroke patients treated with MT, especially in the setting of poor collateral circulation and/or moderate or severe stroke.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Systematic Uncertainties in High-Rate Germanium Data

For many nuclear material safeguards inspections, spectroscopic gamma detectors are required which can achieve high event rates (in excess of 10^6 s^-1) while maintaining very good energy resolution for discrimination of neighboring gamma signatures in complex backgrounds. Such spectra can be useful for non-destructive assay (NDA) of spent nuclear fuel with long cooling times, which contains many potentially useful low-rate gamma lines, e.g., Cs-134, in the presence of a few dominating gamma lines, such as Cs-137. Detectors in use typically sacrifice energy resolution for count rate, e.g., LaBr3, or visa versa, e.g., CdZnTe. In contrast, we anticipate that beginning with a detector with high energy resolution, e.g., high-purity germanium (HPGe), and adapting the data acquisition for high throughput will be able to achieve the goals of the ideal detector. In this work, we present quantification of Cs-134 and Cs-137 activities, useful for fuel burn-up quantification, in fuel that has been cooling for 22.3 years. A segmented, planar HPGe detector is used for this inspection, which has been adapted for a high-rate throughput in excess of 500k counts/s. Using a very-high-statistic spectrum of 2.4*10^11 counts, isotope activities can be determined with very low statistical uncertainty. However, it is determined that systematic uncertainties dominate in such a data set, e.g., the uncertainty in the pulse line shape. This spectrum offers a unique opportunity to quantify this uncertainty and subsequently determine required counting times for given precision on values of interest.

burn-up↗

NanoPSD: A software for automatic detection of Nano-Particle Shape Distribution in electron microscopy images

Accurate quantification of the size and morphology of nanoparticles from electron microscopy (EM) images is essential to understand growth mechanisms, surface reactivity, and functional behavior in nanoscale materials. Manual analysis remains slow, subjective, and difficult to reproduce in large datasets. We introduce NanoPSD (Nano-Particle Shape Distribution), an open-source and fully automated framework for quantitative particle detection and morphology analysis from EM images. NanoPSD integrates adaptive contrast enhancement, polarity-agnostic scale-bar detection, Optical Character Recognition (OCR)-based calibration, and classical segmentation via Otsu thresholding with morphological refinement. Particle contours are used to extract geometric descriptors, including equivalent circular diameter, aspect ratio, circularity, and solidity, enabling automated classification into spherical, rod-like, and aggregate morphologies. The framework supports both single-image and batch processing, generating publication-quality visualizations, LaTeX-ready tables, and structured comma-separated values (CSV) datasets. As a demonstration, we applied NanoPSD to plasma-synthesized nanoparticle samples diagnosed via transmission electron microscopy (TEM). The code produced statistically robust size and morphology distributions spanning a few to tens of nanometers with minimal user supervision. The pipeline demonstrates high reproducibility and scalability, processing large image collections with consistent calibration and output formatting. Its modular design enables seamless integration of future deep-learning-based segmentation models, providing a pathway toward intelligent, data-driven electron microscopy analysis.

36 MATERIALS SCIENCE↗

Assessment of Tumor Volumes in Skull Base Glomus Tumors Using Gluc-Lys[{sup 18}F]-TOCA Positron Emission Tomography

Purpose: To assess a threshold for Gluc-Lys[{sup 18}F]-TOCA positron emission tomography (PET) in target volume delineation of glomus tumors in the skull base and to compare with MRI-based target volume delineation. Methods and Materials: The threshold for volume segmentation in the PET images was determined by a phantom study. Nine patients with a total of 11 glomus tumors underwent PET either with Gluc-Lys[{sup 18}F]-TOCA or with {sup 68}Ga-DOTATOC (in 1 case). All patients were additionally scanned by MRI. Positron emission tomography and MR images were transferred to a treatment-planning system; MR images were analyzed for lesion volume by two observers, and PET images were analyzed by a semiautomated thresholding algorithm. Results: Our phantom study revealed that 32% of the maximum standardized uptake value is an appropriate threshold for tumor segmentation in PET-based target volume delineation of gross tumors. Target volume delineation by MRI was characterized by high interobserver variability. In contrast, interobserver variability was minimal if fused PET/MRI images were used. The gross tumor volumes (GTVs) determined by PET (GTV-PET) showed a statistically significant correlation with the GTVs determined by MRI (GTV-MRI) in primary tumors; in recurrent tumors higher differences were found. The mean GTV-MRI was significantly higher than mean GTV-PET. The increase added by MRI to the common volume was due to scar tissue with strong signal enhancement on MRI. Conclusions: In patients with glomus tumors, Gluc-Lys[{sup 18}F]-TOCA PET helps to reduce interobserver variability if an appropriate threshold for tumor segmentation has been determined for institutional conditions. Especially in patients with recurrent tumors after surgery, Gluc-Lys[{sup 18}F]-TOCA PET improves the accuracy of GTV delineation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-H-207A-03: The Universality of the Lognormal Behavior of [F-18]FLT PET SUV Measurements

Purpose: Log transforming [F-18]FDG PET standardized uptake values (SUVs) has been shown to lead to normal SUV distributions, which allows utilization of powerful parametric statistical models. This study identified the optimal transformation leading to normally distributed [F-18]FLT PET SUVs from solid tumors and offers an example of how normal distributions permits analysis of non-independent/correlated measurements. Methods: Forty patients with various metastatic diseases underwent up to six FLT PET/CT scans during treatment. Tumors were identified by nuclear medicine physician and manually segmented. Average uptake was extracted for each patient giving a global SUVmean (gSUVmean) for each scan. The Shapiro-Wilk test was used to test distribution normality. One parameter Box-Cox transformations were applied to each of the six gSUVmean distributions and the optimal transformation was found by selecting the parameter that maximized the Shapiro-Wilk test statistic. The relationship between gSUVmean and a serum biomarker (VEGF) collected at imaging timepoints was determined using a linear mixed effects model (LMEM), which accounted for correlated/non-independent measurements from the same individual. Results: Untransformed gSUVmean distributions were found to be significantly non-normal (p<0.05). The optimal transformation parameter had a value of 0.3 (95%CI: −0.4 to 1.6). Given the optimal parameter was close to zero (which corresponds to log transformation), the data were subsequently log transformed. All log transformed gSUVmean distributions were normally distributed (p>0.10 for all timepoints). Log transformed data were incorporated into the LMEM. VEGF serum levels significantly correlated with gSUVmean (p<0.001), revealing log-linear relationship between SUVs and underlying biology. Conclusion: Failure to account for correlated/non-independent measurements can lead to invalid conclusions and motivated transformation to normally distributed SUVs. The log transformation was found to be close to optimal and sufficient for obtaining normally distributed FLT PET SUVs. These transformations allow utilization of powerful LMEMs when analyzing quantitative imaging metrics.

60 APPLIED LIFE SCIENCES↗

Computed tomography-based texture analysis of bladder cancer: differentiating urothelial carcinoma from micropapillary carcinoma

Purpose: The purpose of the study is to determine the feasibility of using computed tomography-based texture analysis (CTTA) in differentiating between urothelial carcinomas (UC) of the bladder from micropapillary carcinomas (MPC) of the bladder. Methods: Regions of interests (ROIs) of computerized tomography (CT) images of 33 MPCs and 33 UCs were manually segmented and saved. Custom MATLAB code was used to extract voxel information corresponding to the ROI. The segmented tumors were input to a pre-existing radiomics platform with a CTTA panel. A total of 58 texture metrics were extracted using four different texture extraction techniques and statistically analyzed using a Wilcoxon rank-sum test to determine the differences between UCs and MPCs. Results: Of the 58 texture metrics extracted using the gray level co-occurrence matrix (GLCM) and gray level difference matrix (GLDM), 28 texture metrics were statistically significant (p < 0.05) for differences in tumor textures and 27 texture metrics were statistically significant (p < 0.05) for peritumoral fat textures. The remaining nine metrics extracted using histogram and fast Fourier transform analyses did not show significant differences between the textures of the tumors and their peritumoral fat. Conclusions: CTTA shows that MPC have a more heterogeneous texture compared to UC. As visual discrimination of MPC from UC from clinical CT scans are difficult, results from this study suggest that tumor heterogeneity extracted using GLCM and GLDM may be a good imaging aid in segregating MPC from UC. This tool can aid clinicians in further sub-classifying bladder cancers on routine imaging, a process which has potential to alter treatment and patient care.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Highly Resolved Reference Projections of Building Energy Use for the Contiguous United States: Building Sector Energy Baselines, Projection Methods, and Results

This report describes one methodology of projecting energy consumption of the US residential and commercial building sectors using NREL's ResStock™ and ComStock™ as well as growth rates derived from EIA's Annual Energy Outlook (AEO). The impetus for this work is to provide an intermediate method for compiling demand-side sectoral energy projections that is suitable for grid-scale analysis, such as NREL's Standard Scenarios. ResStock and ComStock are physics-based and statistically representative building stock models of the US residential and commercial sector, respectively. Using the 2012 actual meteorological year (AMY) weather data, the sectoral energy baselines are simulated and then segmented along key dimensions (e.g., geography, dwelling/building type). The segmented results are then scaled using the corresponding annual growth rates derived from the 2021 AEO reference case to produce energy projections out to 2050. The compiled result is a demand-side grid model (dsgrid) data set suitable for use in NREL's large-scale grid models, such as the Regional Energy Deployment System (ReEDS). This simple projection method does not endogenously represent how the building stock could evolve through time. Most notably, it does not reflect large-scale electrification, for example, the conversion of space heating, water heating, clothes drying, and cooking from primary fossil fuels to electricity, as this is not part of AEO's reference case assumptions. Nonetheless this approach is more resolved and potentially extensible compared to the current method used by Standard Scenarios's reference case, which augments a sector's total load based on a single growth rate from AEO.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Expanded genetic variation (SNP) and phenomics (image based) dataset for Populus trichocarpa

The image dataset consists of 11,791 images representing 1,219 genotypes of Populus trichocarpa undergoing in planta regeneration. Genotypes were imaged with a median of four weekly timepoints and a median of two replicates each. A representative and diverse subset of 249 images was annotated using the IDEAS annotation interface (ideas.eecs.oregonstate.edu) and these annotated images were used to train a deep semantic segmentation model (PSPNet), which was deployed for inference over the entire dataset. Annotated classes include specific stages of regeneration (callus and shoot) in addition to unregenerated plant material and background. Statistics of relative tissue area were extracted and used for downstream genetic association mapping in a genome-wide association study. The SNP dataset consists of over 40 million single-nucleotide polymorphisms across 1,323 wild accessions of Populus trichocarpa

09 BIOMASS FUELS↗

Model Validation of Phase-Induced Amplitude Apodization Complex Mask Coronagraph for LUVOIR-A in Vacuum

The Phase-Induced Amplitude Apodization Complex Mask Coronagraph (PIAACMC) is a coronagraph architecture for the next generation of large space telescopes optimized for habitable exoplanet imaging that can achieve attractive theoretical performance with high throughput at small inner working angles (IWA). PIAACMC designs are compatible with large, on-axis, segmented apertures such as the Large UV / Optical/ Infrared A (LUVOIR-A) concept currently being considered by the decadal survey review which would greatly enhance the possibility to achieve statistically significant scientific yields and signal quality for direct imaging exoplanet surveys. PIAACMC has been recently implemented for LUVOIR-A and is currently being tested in vacuum at JPL’s High-Contrast Imaging Testbed (HCIT). In this work, we review the theoretical performance of the PIAACMC instrument designed to meet a 1e-9 raw contrast goal in 10% broadband light in a region from 2-8 L/D both before and after the wavefront control loop. We use empirical measurements from the vacuum testbed to verify the instrument model and its performance including line-of-sight errors, instrument alignment, and fabricated components. In particular, the model verification includes measured sags of the manufactured PIAA mirrors by NuTek. The CMC mask was manufactured at JPL’s Microdevices Laboratory and we include surface profile characterization measurement. We assess the impact on performance of the different manufacturing and alignment errors.

High-Contrast Imaging↗

Toward Magnetic Resonance–Only Simulation: Segmentation of Bone in MR for Radiation Therapy Verification of the Head

Purpose: To develop a practical method to localize bones in magnetic resonance (MR) images, to create “computed tomography–like” MR images (ctMRI) that could be used for radiation therapy verification, and to generate MR-based digitally reconstructed radiographs (DRR). Methods and Materials: Using T1-weighted MR images, an air mask was derived from the manual contouring of all airways within the head and neck region using axial images at 6 anatomic levels. Compact bone, spongy bone, and soft tissue masks were then automatically generated using the statistical data derived from MR intensities and the air mask. ctMRI were then generated by mapping the MR intensities of the voxels within these masks into the CT number ranges of corresponding tissues. MR-based DRRs created from ctMRI were quantitatively evaluated using the co-registered MR and CT head images of 20 stereotactic radiosurgery patients. Ten anatomical points, positioned on the skull segmented using a threshold of 300 HU, in CT and ctMRI, were used to determine the differences in distance between MR-based DRRs and CT-based DRRs, and to evaluate the geometric accuracy of ctMRI and MR-based DRRs. Results: The bony structures were identified on ctMRI and were visible in the MR-based DRRs. From the 20 patient cases, the mean geometric difference and standard deviation between the 10 anatomical points on MR-based and CT-based DRRs was −0.05 ± 0.85 mm, respectively. This included uncertainty in image fusion. The maximum distance difference was 1.88 mm. Conclusions: A practical method was developed to segment bone from MR images. The ctMRI created can be used for radiation treatment verification when MR-only simulation is performed. MR-based DRRs can be used in place of CT-based DRRs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

RU-net for automatic characterization of TRISO fuel cross sections

During irradiation, phenomena such as kernel swelling and buffer densification may impact the performance of tristructural isotropic (TRISO) particle fuel. Post-irradiation microscopy is often used to identify these irradiation-induced morphologic changes. However, each fuel compact generally contains thousands of TRISO particles. Manually performing the work to get statistical information on these phenomena is cumbersome and subjective. Here, to reduce the subjectivity inherent in that process and to accelerate data analysis, we used convolutional neural networks (CNNs) to automatically segment cross-sectional images of microscopic TRISO layers. CNNs are a class of machine-learning algorithms specifically designed for processing structured grid data. They have gained popularity in recent years due to their remarkable performance in various computer vision tasks, including image classification, object detection, and image segmentation. In this research, we generated a large irradiated TRISO layer dataset with more than 2,000 microscopic images of cross-sectional TRISO particles and the corresponding annotated images. Based on these annotated images, we used different CNNs to automatically segment different TRISO layers. These CNNs include RU-Net (developed in this study), as well as three existing architectures: U-Net, Residual Network (ResNet), and Attention U-Net. The preliminary results show that the model based on RU-Net performs best in terms of Intersection over Union (IoU). Using CNN models, we can expedite the analysis of TRISO particle cross sections, significantly reducing the manual labor involved and improving the objectivity of the segmentation results.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The design and networking of dynamic satellite constellations for global mobile communication systems

Various design factors for mobile satellite systems, whose aim is to provide worldwide voice and data communications to users with hand-held terminals, are examined. Two network segments are identified - the ground segment (GS) and the space segment (SS) - and are seen to be highly dependent on each other. The overall architecture must therefore be adapted to both of these segments, rather than each being optimized according to its own criteria. Terrestrial networks are grouped and called the terrestrial segment (TS). In the SS, of fundamental importance is the constellation altitude. The effect of the altitude on decisions such as constellation design choice and on network aspects like call handover statistics are fundamental. Orbit resonance is introduced and referred to throughout. It is specifically examined for its useful properties relating to GS/SS connectivities.

Cullen, Cionaith J.↗

Material Science Image Analysis using Quant-CT in ImageJ

We introduce a computational analysis workflow to access properties of solid objects using nondestructive imaging techniques that rely on X-ray imaging. The goal is to process and quantify structures from material science sample cross sections. The algorithms can differentiate the porous media (high density material) from the void (background, low density media) using a Boolean classifier, so that we can extract features, such as volume, surface area, granularity spectrum, porosity, among others. Our workflow, Quant-CT, leverages several algorithms from ImageJ, such as statistical region merging and 3D object counter. It also includes schemes for bilateral filtering that use a 3D kernel, for parallel processing of sub-stacks, and for handling over-segmentation using histogram similarities. The Quant-CT supports fast user interaction, providing the ability for the user to train the algorithm via subsamples to feed its core algorithms with automated parameterization. Quant-CT plugin is currently available for testing by personnel at the Advanced Light Source and Earth Sciences Divisions and Energy Frontier Research Center (EFRC), LBNL, as part of their research on porous materials. The goal is to understand the processes in fluid-rock systems for the geologic sequestration of CO2, and to develop technology for the safe storage of CO2 in deep subsurface rock formations. We describe our implementation, and demonstrate our plugin on porous material images. This paper targets end-users, with relevant information for developers to extend its current capabilities.

97 MATHEMATICS AND COMPUTING↗

Anterior segment sparing to reduce charged particle radiotherapy complications in uveal melanoma

PURPOSE: The purpose of this investigation is to delineate the risk factors in the development of neovascular glaucoma (NVG) after helium-ion irradiation of uveal melanoma patients and to propose treatment technique that may reduce this risk. METHODS AND MATERIALS: 347 uveal melanoma patients were treated with helium-ions using a single-port treatment technique. Using univariate and multivariate statistics, the NVG complication rate was analyzed according to the percent of anterior chamber in the radiation field, tumor size, tumor location, sex, age, dose, and other risk factors. Several University of California San Francisco-Lawrence Berkeley National Laboratory (LBNL) patients in each size category (medium, large, and extralarge) were retrospectively replanned using two ports instead of a single port. By using appropriate polar and azimuthal gaze angles or by treating patients with two ports, the maximum dose to the anterior segment of the eye can often be reduced. Although a larger volume of anterior chamber may receive a lower dose by using two ports than a single port treatment. We hypothesize that this could reduce the level of complications that result from the irradiation of the anterior chamber of the eye. Dose-volume histograms were calculated for the lens, and compared for the single and two-port techniques. RESULTS: NVG developed in 121 (35%) patients. The risk of NVG peaked between 1 and 2.5 years posttreatment. By univariate and multivariate analysis, the percent of lens in the field was strongly correlated with the development of NVG. Other contributing factors were tumor height, history of diabetes, and vitreous hemorrhage. Dose-volume histogram analysis of single-port vs. two-port techniques demonstrate that for some patients in the medium and large category tumor groups, a significant decrease in dose to the structures in the anterior segment of the eye could have been achieved with the use of two ports. CONCLUSION: The development of NVG after helium-ion irradiation is correlated to the amount of lens, anterior chamber in the treatment field, tumor height, proximity to the fovea, history of diabetes, and the development of vitreous hemorrhage. Although the influence of the higher LET deposition of helium-ions is unclear, this study suggests that by reducing the dose to the anterior segment of the eye may reduce the NVG complications. Based on this retrospective analysis of LBNL patients, we have implemented techniques to reduce the amount of the anterior segment receiving a high dose in our new series of patients treated with protons using the cyclotron at the UC Davis Crocker Nuclear Laboratory (CNL).

NASA Discipline Radiation Health↗