Search NASA⌕ Search

SEARCH · Search NASA

Results for “structural reconstruction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

High-resolution structure of viruses from random diffraction snapshots

The advent of the X-ray free-electron laser (XFEL) has made it possible to record diffraction snapshots of biological entities injected into the X-ray beam before the onset of radiation damage. Algorithmic means must then be used to determine the snapshot orientations and thence the threedimensional structure of the object. Existing Bayesian approaches are limited in reconstruction resolution typically to 1/10 of the object diameter, with the computational expense increasing as the eighth power of the ratio of diameter to resolution.We present an approach capable of exploiting object symmetries to recover three-dimensional structure to high resolution, and thus reconstruct the structure of the satellite tobacco necrosis virus to atomic level. Our approach offers the highest reconstruction resolution for XFEL snapshots to date and provides a potentially powerful alternative route for analysis of data from crystalline and nano-crystalline objects.

59 BASIC BIOLOGICAL SCIENCES↗

Retrieving spin textures on curved magnetic thin films with full-field soft X-ray microscopies

X-ray tomography is a well-established technique to characterize 3D structures in material sciences and biology; its magnetic analogue—magnetic X-ray tomography—is yet to be developed. We demonstrate the visualization and reconstruction of magnetic domain structures in a 3D curved magnetic thin films with tubular shape by means of full-field soft X-ray microscopies. In the 3D arrangement of the magnetization is retrieved from a set of 2D projections by analysing the evolution of the magnetic contrast with varying projection angle. By using reconstruction algorithms to analyse the angular evolution of 2D projections provides quantitative information about domain patterns and magnetic coupling phenomena between windings of azimuthally and radially magnetized tubular objects. In conclusion, the present approach represents a first milestone towards visualizing magnetization textures of 3D curved thin films with virtually arbitrary shape.

36 MATERIALS SCIENCE↗

Observation of a (√3x√3)R30° Reconstruction on O-Polar ZnO Surfaces

Low energy electron diffraction revealed a previously unreported (3x3)R30 reconstruction on clean, O-polar ZnO surfaces after in-situ preparation under conditions with an extremely low H background or after ex-situ tube-furnace annealing [1]. It has been proposed that unreconstructed, H-free, O-polar ZnO surfaces cannot be produced [2]. As the sample is prepared from the as-received surface, to a clean (1x1), and finally to the clean (3x3)R30 reconstruction, x-ray photoelectron spectroscopy shows decreasing intensity of the hydroxyl shoulder (located to the high-binding-energy side of the O1s peak). This reconstruction is stable against H2, N2, and air, although its formation is suppressed when preparation occurs under an intentional H2 background. A structural investigation of the reconstruction with LEED-IV is under way.

36 MATERIALS SCIENCE↗

Electronic structures of the SrTiO{sub 3}(110) surface in different reconstructions

The surface of SrTiO{sub 3}(110) single crystal is prepared in monophase with different reconstructions. The increase of surface Ti concentration is responsible for the evolution of the reconstruction from (4 Multiplication-Sign 1) to (2 Multiplication-Sign 8), and to a new (1 Multiplication-Sign 10) structure. It also induces the enhancement of the surface metallicity, characterized by the appearance of the in-gap states and the increasing Drude weight as measured by the electron and photoelectron spectroscopies. We attribute the metallicity to the reduced Ti ions, which is consistent with the observed band structures and the shift of the phonon energy. It is indicated that a heterointerface between a reduced titanate layer and SrTiO{sub 3} crystal with unique electronic structure can be obtained by the simple treatment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Vortex tubes in turbulent flows: Identification, representation, reconstruction

In many cases the structure of a fluid flow is well-characterized by its vortices, especially for the purpose of visualization. In this paper we present a new algorithm for identifying vortices in complex flows. The algorithm produces a skeleton line along the center of a vortex by using a two-step predictor-corrector scheme. The vorticity vector field serves as the predictor and the pressure gradient (in the perpendicular plane) serves as the corrector. We describe an economical description of the vortex tube's cross-section: a 5-term truncated Fourier series is generally sufficient, and it compresses the representation of the flow by a factor of 4000 or more. We reconstruct the vortex tubes as generalized cylinders, providing a polygonal mesh suitable for display on a graphics workstation. We show how the reconstructed geometry of vortex tubes can be enhanced to help visualize helical motion in a static image.

Banks, David C.↗

The Role of Secondary Particle Structures in Surface Phase Transitions of Ni-Rich Cathodes

Nanometer-thick reconstruction layers on layered cathode surfaces have been widely observed on both pristine and cycled materials. However, the mechanisms of reconstruction and the role that these structures play in electrochemical performance are not fully understood. From a crystallographic perspective, such surface reconstruction layers result from cation site-mixing between Li and transition-metal ions, but it remains far from clear as to what the critical factors are that control such cation mixing for various cathode chemistries. In this paper, we report observations on surface transformations during cycling of a Ni-rich cathode-oxide that are governed by direct contact with the liquid electrolyte. Specifically, within a secondary particle, the three-dimensional hierarchical aggregate of primary particles leads to the formation of grain boundaries of different characteristics, including open grain boundaries that allow the permeation of liquid electrolyte, and closed grain boundaries that exclude liquid electrolyte penetration. Upon battery cycling, surfaces in direct contact with the liquid electrolyte showed a surface reconstruction layer while the surfaces that did not have contact with the electrolyte showed no such reconstructions. In addition, the critical role of oxygen in reconstruction of grain boundaries is demonstrated, and the unexpected oxygen depletion at twin boundaries result in severe phase transitions. The present work provides further insights into phase transitions at solid-solid and solid-liquid interfaces within secondary cathode particles and suggests strategies for mitigating surface/interfacial degradation.

36 MATERIALS SCIENCE↗

In situ TEM observation of calcium silicate hydrate nanostructure at high temperatures

Fire poses a substantial threat to concrete structures because calcium silicate hydrate (C-S-H) is not thermally stable at high temperatures. Herein, in situ TEM at temperatures from 20 to 800 °C was conducted to study the thermal-induced structural changes in C-S-H. We captured C-S-H shrinks at an average rate of 0.02 μm{sup 2}/{sup o}C upon heating with three stages observed, including induction, constant, and rapid periods. Our observation revealed that an 800 nm pore could be healed during pore structure evolution owing to the reconstruction and deformation among C-S-H blocks. The Ca/Si ratio was dropped at higher temperatures because of the leakage of calcium ions from the C-S-H structure to form CaO precipitates. The temperature-driven phase transformation and degradation were also detected using electron diffraction that C-S-H was transformed into metastable calcium silicate minerals above 800 °C. This work provides insights into the nanoscale transformation of C-S-H at high temperatures.

36 MATERIALS SCIENCE↗

Simulated annealing reconstruction and characterization of the three-dimensional microstructure of a LiCoO{sub 2} Lithium-ion battery cathode

We adapt the simulated annealing approach for reconstruction of the 3D microstructure of a LiCoO{sub 2} cathode from a commercial Li-ion battery. The real size distribution curve of LiCoO{sub 2} particles is applied to regulate the reconstruction process. By discretizing a 40 × 40 × 40 μm cathode volume with 8,000,000 numerical cubes, the cathode involving three individual phases: 1) LiCoO{sub 2} as active material, 2) pores or electrolyte, and 3) additives (polyvinylidene fluoride + carbon black) is reconstructed. The microstructural statistical properties required in the reconstruction process are extracted from 2D focused ion beam/scanning electron microscopy images or obtained by analyzing the powder mixture used to make the cathode. Characterization of the reconstructed cathode gives important structural and transport properties including the two-point correlation functions, volume-specific surface area between phases, tortuosity and geometrical connectivity of individual phase. - Highlights: • Simulated annealing approach is adapted for 3D reconstruction of LiCoO{sub 2} cathode. • Real size distribution of LiCoO{sub 2} particles is applied in reconstruction process. • Reconstructed cathode accords with real one at important statistical properties. • Effective electrode-characterization approaches have been established. • Extensive characterization gives important structural properties, say, tortuosity.

36 MATERIALS SCIENCE↗

Size Effect of Local Current-Voltage Characteristics of MX 2 Nanoflakes: Local Density of States Reconstruction from Scanning Tunneling Microscopy Experiments

Local current-voltage characteristics for low-dimensional transition-metal dichalcogenides (LDTMD), as well as the reconstruction of their local density of states (LDOS) from scanning tunneling microscopy (STM) experiments, are of fundamental interest and can be useful for advanced applications. Most of the existing models either have limited applicability for complex-shaped LDTMDs (e.g., those based on the Simmons approach) or require solving of an ill-defined integral equation to deconvolute the unknown LDOS (e.g., those based on the Tersoff approach). Using a serial expansion of the Tersoff formulas, we propose a flexible method to reconstruct the LDOS from local current-voltage characteristics measured in STM experiments. We establish a set of key physical parameters, which characterize the tunneling current of a STM-probe–sample contact and the sample LDOS expanded in Gaussian functions. Using a direct variational method coupled with probabilistic analysis, we determine these parameters from the STM experiments for MoS2 nanoflakes with different numbers of layers. The main result is the reconstruction of the LDOS in a relatively wide energy range around the Fermi level, which allows us to gain insight into the local band structure of LDTMDs. The reconstructed LDOS reveal pronounced size effects for the single-layer, two-layer, and three-layer MoS 2 nanoflakes, which we relate to the low dimensionality and strong bending or corrugation of the nanoflakes. We hope that the proposed elaboration of the Tersoff approach, allowing LDOS reconstruction, will be of critical interest for the quantitative description of STM experiments and also of use to better understand the microscopic physical aspects of the surface, strain, and bending contributions to the LDTMDs’ electronic properties.

42 ENGINEERING↗

A novel digital tomosynthesis (DTS) reconstruction method using a deformation field map

We developed a novel digital tomosynthesis (DTS) reconstruction method using a deformation field map to optimally estimate volumetric information in DTS images. The deformation field map is solved by using prior information, a deformation model, and new projection data. Patients' previous cone-beam CT (CBCT) or planning CT data are used as the prior information, and the new patient volume to be reconstructed is considered as a deformation of the prior patient volume. The deformation field is solved by minimizing bending energy and maintaining new projection data fidelity using a nonlinear conjugate gradient method. The new patient DTS volume is then obtained by deforming the prior patient CBCT or CT volume according to the solution to the deformation field. This method is novel because it is the first method to combine deformable registration with limited angle image reconstruction. The method was tested in 2D cases using simulated projections of a Shepp-Logan phantom, liver, and head-and-neck patient data. The accuracy of the reconstruction was evaluated by comparing both organ volume and pixel value differences between DTS and CBCT images. In the Shepp-Logan phantom study, the reconstructed pixel signal-to-noise ratio (PSNR) for the 60 deg. DTS image reached 34.3 dB. In the liver patient study, the relative error of the liver volume reconstructed using 60 deg. projections was 3.4%. The reconstructed PSNR for the 60 deg. DTS image reached 23.5 dB. In the head-and-neck patient study, the new method using 60 deg. projections was able to reconstruct the 8.1 deg. rotation of the bony structure with 0.0 deg. error. The reconstructed PSNR for the 60 deg. DTS image reached 24.2 dB. In summary, the new reconstruction method can optimally estimate the volumetric information in DTS images using 60 deg. projections. Preliminary validation of the algorithm showed that it is both technically and clinically feasible for image guidance in radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MO-DE-207A-09: Low-Dose CT Image Reconstruction Via Learning From Different Patient Normal-Dose Images

Purpose: To investigate a novel low-dose CT (LdCT) image reconstruction strategy for lung CT imaging in radiation therapy. Methods: The proposed approach consists of four steps: (1) use the traditional filtered back-projection (FBP) method to reconstruct the LdCT image; (2) calculate structure similarity (SSIM) index between the FBP-reconstructed LdCT image and a set of normal-dose CT (NdCT) images, and select the NdCT image with the highest SSIM as the learning source; (3) segment the NdCT source image into lung and outside tissue regions via simple thresholding, and adopt multiple linear regression to learn high-order Markov random field (MRF) pattern for each tissue region in the NdCT source image; (4) segment the FBP-reconstructed LdCT image into lung and outside regions as well, and apply the learnt MRF prior in each tissue region for statistical iterative reconstruction of the LdCT image following the penalized weighted least squares (PWLS) framework. Quantitative evaluation of the reconstructed images was based on the signal-to-noise ratio (SNR), local binary pattern (LBP) and histogram of oriented gradients (HOG) metrics. Results: It was observed that lung and outside tissue regions have different MRF patterns predicted from the NdCT. Visual inspection showed that our method obviously outperformed the traditional FBP method. Comparing with the region-smoothing PWLS method, our method has, in average, 13% increase in SNR, 15% decrease in LBP difference, and 12% decrease in HOG difference from reference standard for all regions of interest, which indicated the superior performance of the proposed method in terms of image resolution and texture preservation. Conclusion: We proposed a novel LdCT image reconstruction method by learning similar image characteristics from a set of NdCT images, and the to-be-learnt NdCT image does not need to be scans from the same subject. This approach is particularly important for enhancing image quality in radiation therapy.

60 APPLIED LIFE SCIENCES↗

Pulsed Thermal Tomography Nondestructive Examination of Additively Manufactured Reactor Materials (Second Annual Progress Report)

Additive manufacturing (AM) is an emerging method for cost-efficient fabrication of nuclear reactor parts. AM of metallic structures for nuclear energy applications is currently based on laser powder bed fusion (LPBF) process, which can introduce internal material flaws, such as pores and anisotropy. Integrity of AM structures needs to be evaluated nondestructively because material flaws could lead to premature failures due to exposure to high temperature, radiation and corrosive environment in a nuclear reactor. Thermal tomography (TT) provides a capability for non-destructive evaluation of sub-surface defects in arbitrary size structures. Thermal tomography is a computational method for heat diffusion-based imaging of solids, which provides 3D visualization of data from flash thermography measurements. We investigate thermal tomography imaging and nondestructive evaluation of stainless steel and nickel super alloy metallic structures produced with laser powder bed fusion (LPBF) additive manufacturing (AM) process. Metallic structures produced with LPBF contain defects, and there are limited capabilities to evaluate these structures non-destructively. Thermal tomography reconstruction of 3D apparent spatial effusivity provides information about AM structure geometry and internal material flaws. We study performance of thermal tomography in imaging of metallic structures through COMSOL computer simulations of transient heat transfer, and through reconstruction of data obtained from experimental measurements. Reconstruction of internal defects is investigated using a stainless steel 316L specimen with flat bottom hole (FBH) indentations, and Inconel 718 plate produced with laser powder bed fusion (LPBF) method, which contains imprinted hemispherical shape low density regions containing non-sintered metallic powder. The FBH’s have the same sizes as the imprinted defects in the LPBF specimens, but offer better imaging contrast. Thermal tomography reconstructions provide visualizations of internal defects, and allow for estimation of their sizes and locations. Detection sensitivity of TT is limited by noises. We investigate separation of signal from noise in thermography images using several machine learning (ML) methods, including new spatio-temporal blind source separation (STBSS) and spatio-temporal sparse dictionary learning (STSDL) methods. Performance of the ML methods is benchmarked using thermography data obtained from imaging stainless steel 316L and Inconel 718 specimens produced LPBF method with imprinted calibrated porosity defects. The ML methods are ranked by F-score and execution runtime. Finally, we investigate TT of AM stainless steel 316L specimen with imprinted internal porosity defects using relatively low-cost, small form factor infrared (IR) camera based on uncooled micro bolometer detector. Sparse coding related K-means singular value decomposition (SVD) machine learning, image processing algorithms are developed to improve quality of TT images through removal of Additive white Gaussian noise without blurring the images. Following initial qualification of an AM component for deployment in a nuclear reactor, a compact TT can also be used for in-service nondestructive evaluation (NDE). With capability to perform in-service NDE of the AM component lifecycle, TT data can be used for development of a component digital twin.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Reconstruction from limited single-particle diffraction data via simultaneous determination of state, orientation, intensity, and phase

Significance Single-particle diffraction is an emerging technique in which diffraction images are collected from individual particles, and is used to study molecular structure from multiple conformational states that may be inaccessible through other methods. However, determining structure from these experiments is challenging, since orientations and states of imaged particles are unknown and images are highly contaminated with noise. Furthermore, the number of useful images is often limited by achievable single-particle hit rates, currently around 0.1%. We introduce an iterative projection framework to simultaneously determine orientations, states, and molecular structure from limited single-particle data by leveraging structural constraints throughout the reconstruction. This framework offers a potential pathway to increasing the amount of information that can be extracted from single-particle diffraction.

97 MATHEMATICS AND COMPUTING↗

Chlorine adsorption on the InAs (001) surface

Chlorine adsorption on the In-stabilized InAs(001) surface with {zeta}-(4 Multiplication-Sign 2) and {beta}3 Prime -(4 Multiplication-Sign 2) reconstructions and on the Ga-stabilized GaAs (001)-{zeta}-(4 Multiplication-Sign 2) surface has been studied within the electron density functional theory. The equilibrium structural parameters of these reconstructions, surface atom positions, bond lengths in dimers, and their changes upon chlorine adsorption are determined. The electronic characteristics of the clean surface and the surface with adsorbed chlorine are calculated. It is shown that the most energetically favorable positions for chlorine adsorption are top positions over dimerized indium or gallium atoms. The mechanism of chlorine binding with In(Ga)-stabilized surface is explained. The interaction of chlorine atoms with dimerized surface atoms weakens surface atom bonds and controls the initial stage of surface etching.

36 MATERIALS SCIENCE↗

Resolution of Virtual Depth Sectioning from Four-Dimensional Scanning Transmission Electron Microscopy

Abstract One approach to three-dimensional structure determination using the wealth of scattering data in four-dimensional (4D) scanning transmission electron microscopy (STEM) is the parallax method proposed by Ophus et al. (2019. Advanced phase reconstruction methods enabled by 4D scanning transmission electron microscopy, Microsc Microanal25, 10–11), which determines the scattering matrix and uses it to synthesize a virtual depth-sectioning reconstruction of the sample structure. Drawing on an equivalence with a hypothetical confocal imaging mode, we derive contrast transfer and point spread functions for this parallax method applied to weakly scattering objects, showing them identical to earlier depth-sectioning STEM modes when only bright field signal is used, but that improved depth resolution is possible if dark field signal can be used. Through a simulation-based study of doped Si, we show that this depth resolution is preserved for thicker samples, explore the impact of shot noise on the parallax reconstructions, discuss challenges to making use of dark field signal, and identify cases where the interpretation of the parallax reconstruction breaks down.

3D imaging↗

CPU Volume Rendering of Adaptive Mesh Refinement Data

Adaptive Mesh Refinement (AMR) methods are widespread in scientific computing, and visualizing the resulting data with efficient and accurate rendering methods can be vital for enabling interactive data exploration. In this work, we detail a comprehensive solution for directly volume rendering block-structured (Berger-Colella) AMR data in the OSPRay interactive CPU ray tracing framework. In particular, we contribute a general method for representing and traversing AMR data using a kd-tree structure, and four different reconstruction options, one of which in particular (the basis function approach) is novel compared to existing methods. Here, we demonstrate our system on two types of block-structured AMR data and compressed scalar field data, and show how it can be easily used in existing production-ready applications through a prototypical integration in the widely used visualization program ParaView.

97 MATHEMATICS AND COMPUTING↗

Structural evolution of the P22-like phages: Comparison of Sf6 and P22 procapsid and virion architectures

Coat proteins of tailed, dsDNA phages and in herpesviruses include a conserved core similar to the bacteriophage HK97 subunit. This core is often embellished with other domains such as the telokin Ig-like domain of phage P22. Eighty-six P22-like phages and prophages with sequenced genomes share a similar set of virion assembly genes and, based on comparisons of twelve viral assembly proteins (structural and assembly/packaging chaperones), these phages are classified into three groups (P22-like, Sf6-like, and CUS-3-like). We used cryo-electron microscopy and 3D image reconstruction to determine the structures of Sf6 procapsids and virions ({approx} 7 A resolution), and the structure of the entire, asymmetric Sf6 virion (16-A resolution). The Sf6 coat protein is similar to that of P22 yet it has differences in the telokin domain and in its overall quaternary organization. Thermal stability and agarose gel experiments show that Sf6 virions are slightly less stable than those of P22. Finally, bacterial host outer membrane proteins A and C were identified in lipid vesicles that co-purify with Sf6 particles, but are not components of the capsid.

60 APPLIED LIFE SCIENCES↗