Search NASA⌕ Search

SEARCH · Search NASA

Results for “system noise temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Wind and Temperature Consensus at Horn Point, HU-Beltsville, Piney Run (Maryland) in support of CoURAGE

The Maryland Department of the Environment (MDE) operates a ground-based atmospheric profiling network consisting of collocated radar wind profilers (RWP) and radio acoustic sounding systems (RASS) as part of its Ambient Air Monitoring Program. This network provides continuous observations of wind and temperature structure in the lower troposphere to support air quality forecasting, regulatory analysis, and atmospheric research. The network currently includes three fixed sites across Maryland: Horn Point (HP, lower eastern shore) [38.587525°,-76.141006°], Howard University-Beltsville (HUB, central Maryland) [39.055277°, -76.878632°], and Piney Run (PR, western Maryland) [39.705950°, -79.012000°] The network is designed to capture regional variability in atmospheric transport and boundary-layer processes. These systems measure vertical profiles of horizontal wind speed and direction using Doppler radar techniques, with observations typically spanning from ~100 m above ground level up to approximately 2.5–4 km. Measurements are derived from the Doppler shift of backscattered electromagnetic signals, enabling retrieval of wind vectors at multiple altitudes with high temporal resolution (e.g., 30-minute averages reported every 6 minutes). Each radar wind profiler is paired with a Radio Acoustic Sounding System (RASS) to provide profiles of virtual temperature in the lower atmosphere (~100–200 m AGL) by measuring the propagation speed of acoustic waves. Together, the RWP/RASS system yields a coupled data set of thermodynamic and kinematic atmospheric structure, including additional parameters such as vertical velocity, radial velocity, signal-to-noise ratio, and spectral width for advanced analysis. There are two types of files for each station: wind data (files with a "w" prefix) and virtual temperature RASS data (files with a "t" prefix). The wind data files are in the format wYYDDD.cns, where YY is the 2-digit year and DDD is the day of the year. The RASS virtual temperature data files are in the format tYYDDD.cns. Each record has the following header structure: Line 1 : Station Name RASS files Line 2 : RASS rev DeTect_2.0, WINDS files Line 2 : WINDS rev ATI 5.1 Line 3 : N latitude, W longitude, and site elevation (m) Line 4 : Date and begin time of consensus: yy mm dd hh mn ss plus # minutes to add to get UTC Line 5 : Consensus averaging time (minutes); number of beams; number of range gates Line 6 : Number of records required to make consensus (num) total number of records (tot) and the consensus window size (m/s) in the format: num:tot (window) RASS files Line 7 : no. of coded cells, no. of spec, pulse width (ns), and inter-pulse period (µs), WINDS files Line 7 : No. of coded cells, no. of spectra, pulse width (ns), and inter-pulse period (µs), each with a pair of values: first value is for oblique beams, second for vertical RASS files Line 8 : Full scale Doppler value (m/s) Delay to first gate (ns) Number of gates Spacing of gates (ns), WINDS files Line 8 : Full scale Doppler velocity (m/s), oblique and vertical Vertical correction applied to oblique beams? (0 = no, 1 = yes) Delay to first gate (ns), oblique and vertical Number of gates, oblique and vertical Spacing of gates (ns), oblique and vertical Line 9 : Azimuth and elevation (9s indicate vertical beam not used) RASS files Line 10, values : HT = Height above ground (km), T = Uncorrected virtual temperature consensus (deg C), Tc = Corrected virtual temperature consensus (deg C), W = Vertical wind consensus (9s indicate vertical beam not used, w-component, positive upward, m/s), CNT = Number of records that made consensus (for the 3 values in same order), SNR = Average signal to noise ratio (dB) of records in consensus (same order) WINDS files Line 10, values : HT = Height above ground (km), SPD = Wind speed (m/s), DIR = Wind direction (deg E of N from N), RAD = Radial velocities for each beam (m/s) in order given in azimuth and elevation line (positive toward radar; 9s indicate vertical beam not used, CNT = Number of records that made consensus, SNR = Average signal to noise ratio (dB) of records in consensus

{"wind speed and direction",temperature}↗

Initial in-orbit operation of the soft X-ray spectrometer Resolve onboard the X-ray imaging and spectroscopy mission satellite

The X-Ray Imaging and Spectroscopy Mission satellite was launched on September 6, 2023 (UT). Its Resolve instrument is a high-resolution X-ray spectrometer enabled by a microcalorimeter array thermally anchored to a 50-mK heat sink. Many sensitive, critical sub-systems comprise Resolve, including a multistage cryogenic cooling system, thin-film aperture filters, low-noise electronics, on-board signal processing, and several sources of X-rays for calibration. We summarize the initial on-orbit power-on and checkout of Resolve that commenced immediately after launch. Soon after launch, the cryocoolers were activated, and their operation was successfully established. On October 9, 2023, the first cycle of the adiabatic demagnetization refrigerator was carried out, bringing the sensors to their steady-state operational temperatures. Following this, the energy resolution at 5.9 keV was successfully measured. The energy scale of the system is highly sensitive to the thermal environment surrounding both the sensors and their analog electronics. Gain correction was performed using reference X-ray lines from onboard calibration sources. To optimize cooler frequency settings, noise spectra were collected across a range of frequencies, and the most suitable frequency pair was selected based on the in-orbit environment. During the final phase of the checkout, an attempt was made to open the gate valve, which is designed to protect the Dewar’s interior from external pressure during ground operations and launch. Unfortunately, this attempt was unsuccessful. As a result, the checkout process was temporarily paused, and a stable operational strategy was subsequently developed to enable Resolve to function effectively with the gate valve remaining closed.

X-ray micro-calorimeter↗

Sea-surface temperature and salinity mapping from remote microwave radiometric measurements of brightness temperature

A technique to measure remotely sea surface temperature and salinity was demonstrated with a dual frequency microwave radiometer system. Accuracies in temperature of 1 C and in salinity of part thousand for salinity greater than 5 parts per thousand were attained after correcting for the influence of extraterrestrial background radiation, atmospheric radiation and attenuation, sea-surface roughness, and antenna beamwidth. The radiometers, operating at 1.43 and 2.65 GHz, comprise a third-generation system using null balancing and feedback noise injection. Flight measurements from an aircraft at an altitude of 1.4 km over the lower Chesapeake Bay and coastal areas of the Atlantic Ocean resulted in contour maps of sea-surface temperature and salinity with a spatial resolution of 0.5 km.

Hans-Juergen, C. B.↗

Fracture Characterization Via AI‐Assisted Analysis of Temperature Logs

Abstract Fractures control fluid flow, mass transport, and heat transfer in a geothermal reservoir. This makes accurate characterization of fracture networks a prerequisite for optimal design and control of a reservoir's exploitation. We develop a deep‐learning procedure to identify fracture locations via interpretation of temporally and spatially continuous downhole temperature measurements. A long short‐term memory fully convolutional network (LSTM‐FCN) is used both to capture long‐term dependencies in sequential temperature data and to distill local features around fractures. A wellbore and fractured‐reservoir thermal model is established to generate temperature data for network training. The trained LSTM‐FCN exhibits a unique ability to detect multiple fractures intersecting a borehole. We use the LSTM‐FCN algorithm to evaluate the effectiveness of different‐stage wellbore temperature measurements on fracture detection in a complex fractured system. Our experiments reveal that the use of various‐stage temperature information as an input feature set improves the robustness of fracture detection to noise interference. This study indicates the practical feasibility of obtaining accurate fracture‐network reconstructions from temperature signals, at reasonable computational cost.

Yang, Xiaoyu↗

A high-temperature Rutherford Backscattering Spectrometry apparatus for in situ material characterization

A new methodology for high-temperature Rutherford Backscattering Spectrometry (HT-RBS) has been developed to enable in situ material characterization at elevated temperatures. A 3.5 MeV proton beam penetrates a 10-µm-thick 316L stainless steel foil mounted on a graphite substrate, with backscattered signals detected using an HT-RBS system. Conventional semiconductor detectors, primarily based on silicon, suffer significant performance degradation at temperatures higher than ~ 60 °C due to increased leakage current and noise, leading to signal distortion and failure. Here, to preserve spectral quality, a 5 µm aluminum foil shields the detector from thermal radiation, allowing reliable operation up to 900 °C at the target. A rotatable shutter provides additional thermal isolation during data collection pauses. In situ measurements of areal density changes of 316L stainless steel were conducted to validate the technique, revealing consistency with the known thermal expansion coefficient. The method facilitates seamless switching between irradiation and analysis, enabling continuous studies. This approach supports in situ investigations of diffusion, void swelling, creep, and corrosion, offering a versatile tool for advanced materials research.

36 MATERIALS SCIENCE↗

Ultra-low-noise microwave amplifiers

The highlights of 20 years of maser use and development are presented. Masers discussed include cavity, traveling wave, K band, and S band. Noise temperatures measured since 1960 are summarized. Use of masers in the Deep Space Network is presented. Costs associated with the construction of masers systems are given.

Clauss, R. C.↗

Low-noise cryogenic transmission line

New low-noise cryogenic input transmission lines have been developed for the Deep Space Network (DSN) at 1.668 GHz for cryogenically cooled Field Effect Transistors (FET) and High Electron Mobility Transistor (HEMT) amplifiers. These amplifiers exhibit very low noise temperatures of 5 K to 15 K, making the requirements for a low-noise input transmission line critical. Noise contribution to the total amplifier system from the low-noise line is less than 0.5 K for both the 1.668-GHz and 2.25-GHz FET systems. The 1.668-GHz input line was installed in six FET systems which were implemented in the DSN for the Venus Balloon Experiment. The 2.25-GHz input line has been implemented in three FET systems for the DSN 34-m HEF antennas, and the design is currently being considered for use at higher frequencies.

Norris, D.↗

Spectroscopic Diagnostics and an Arc Jet Heated Air Plasma

Spectral radiation measurements were made in the range of 200 to 900 nm across a section of the plenum of an arc jet wind tunnel using a series of optical fibers. The spectra contained line radiation from Oxygen and Nitrogen atoms and molecular radiation from N2(+), N2, and NO. Abel inversion technique is used to obtain radial distribution of the spectra. The analysis yielded radial profiles of the electronic excitation, vibrational and rotational temperatures of the flow field. Spectral fitting yielded branching ratios for different vibrational and rotational bands. Relatively mild flow conditions, i.e. enthalpy and mass flow rate, were used for prolonged measurements of up to and over two hours to establish the best experimental methods of temperature determinations. Signal to noise was improved by at least an order of magnitude enabling the molecular vibrational band heads of N2(+) (first negative system), N2 (second positive system), and NO (beta, gamma, delta, and epsilon systems) to be resolved in the lower ultraviolet wavelength regions. The increased signal to noise ratio also enabled partial resolution of the rotational lines of N2(+) and N2 in certain regions of minimal overlap. Comparison of the spectra with theoretical models such as the NEQAIR2 code are presented and show potential for fitting the spectra when reliable calibration is performed for the complete wavelength range.

Mack, Larry Howard, Jr.↗

Summarizing Multiple Aspects of Triple Collocation Analysis in a Single Diagram

With the ongoing expansion of global observation networks, it is expected that we shall routinely analyze records of geophysical variables such as temperature from multiple collocated instruments. Validating datasets in this situation is not a trivial task because every observing system has its own bias and noise. Triple collocation is a general statistical framework to estimate the error characteristics in three or more observational-based datasets. In a triple colocation analysis, several metrics are routinely reported but traditional multiple-panel plots are not the most effective way to display information. A new formula of error variance is derived for connecting the key terms in the triple collocation theory. A diagram based on this formula is devised to facilitate triple collocation analysis of any data from observations, as illustrated using three aerosol optical depth datasets from the recent Aerosol Cloud meTeorology Interactions oVer the western ATlantic Experiment (ACTIVATE). An observational-based skill score is also derived to evaluate the quality of three datasets by taking into account both error variance and correlation coefficient. Several applications are discussed and sample plotting routines are provided.

triple collocation↗

A dual charge-coupled device /CCD/, astronomical spectrometer and direct imaging camera. I - Optical and detector systems

The MASCOT (MIT Astronomical Spectrometer/Camera for Optical Telescopes), an instrument capable of simultaneously performing both direct imaging and spectrometry of faint objects, is examined. An optical layout is given of the instrument which uses two CCD's mounted on the same temperature regulated detector block. Two sources of noise on the signal are discussed: (1) the CCD readout noise, which results in a constant uncertainty in the number of electrons collected from each pixel; and (2) the photon counting noise. The sensitivity of the device is limited by the sky brightness, the overall quantum efficiency, the resolution, and the readout noise of the CCD. Therefore, total system efficiency is calculated at about 15%.

Meyer, S. S.↗

Operability of an Ejector Enhanced Pulse Combustor in a Gas Turbine Environment

A pressure-gain combustor comprised of a mechanically valved, liquid fueled pulsejet, an ejector, and an enclosing shroud, was coupled to a small automotive turbocharger to form a self-aspirating, thrust producing gas turbine engine. The system was constructed in order to investigate issues associated with the interaction of pulsed combustion devices and turbomachinery. Installed instrumentation allowed for sensing of distributed low frequency pressure and temperature, high frequency pressure in the shroud, fuel flow rate, rotational speed, thrust, and laboratory noise. The engine ran successfully and reliably, achieving a sustained thrust of 5 to 6 lbf, and maintaining a rotor speed of approximately 90,000 rpm, with a combustor pressure gain of approximately 4 percent. Numerical simulations of the system without pressure-gain combustion indicated that the turbocharger would not operate. Thus, the new combustor represented a substantial improvement in system performance. Acoustic measurements in the shroud and laboratory indicated turbine stage sound pressure level attenuation of 20 dB. This is consistent with published results from detonative combustion experiments. As expected, the mechanical reed valves suffered considerable damage under the higher pressure and thermal loading characteristics of this system. This result underscores the need for development of more robust valve systems for this application. The efficiency of the turbomachinery components did not appear to be significantly affected by unsteadiness associated with pulsed combustion, though the steady component efficiencies were already low, and thus not expected to be particularly sensitive.

Paxson, Daniel E.↗

A low temperature gravitational radiation detector

The beginning design of an experiment is discussed for studying gravitational radiation by using massive detectors which are cooled to ultralow temperatures in order to improve the signal to noise ratios and the effective range and stability of the detectors. The gravitational detector, a low detection system, a cooled detector, magnetic support, superconducting shielding, and superconducting accelerometer detector are described.

Hamilton, W. O.↗

Low noise buffer amplifiers and buffered phase comparators for precise time and frequency measurement and distribution

Extremely low noise, high performance, wideband buffer amplifiers and buffered phase comparators were developed. These buffer amplifiers are designed to distribute reference frequencies from 30 KHz to 45 MHz from a hydrogen maser without degrading the hydrogen maser's performance. The buffered phase comparators are designed to intercompare the phase of state of the art hydrogen masers without adding any significant measurement system noise. These devices have a 27 femtosecond phase stability floor and are stable to better than one picosecond for long periods of time. Their temperature coefficient is less than one picosecond per degree C, and they have shown virtually no voltage coefficients.

Eichinger, R. A.↗

Brief characterization of germanium junction field effect transistors (FETs) at 77, 4, and 1.8 K

In the case of modern infrared focal planes, one of the major problems is related to the noise contribution of the cooled, impedance-matching device used as the preamplifier stage in the detector electronics system. An ideal preamp device should have the low-noise advantages of a buried-channel device and operate isothermally with the low-temperature detector array. The Ge JFET might provide this ideal device. A testing program with Ge JFETs is discussed. It is concluded that germanium JFETs offer an attractive alternative for cryogenic preamplifier designs. They operate well with high transconductance and low noise at LHe temperatures. It is believed that these devices point the way for the development of large, integrated-array, long wavelength, infrared focal planes which incorporate germanium detectors, germanium load resistors, and germanium preamplifiers within the same monolithic structure.

Arentz, R. F.↗

Temperature fluctuations in the canonical ensemble

We report the first quantitative measurements of spontaneous temperature fluctuations in a physical system well modeled by a canonical ensemble. Using superconducting magnetometers and a carefully controlled thermal environment, we have measured the noise spectra of paramagnetic salt thermometers that were coupled to thermal reservoirs at 2 K. The noise spectra were found to be in very good agreement with the predictions of the fluctuation-dissipation theorem. Our observations are at variance with some interpretations of fluctuations in the canonical ensemble.

Chui, T. C. P.↗

Noise Diode Stability Measurements Using a 4.3 GHz Laboratory Radiometer

The need for passive microwave radiometry using aperture synthesis and phased arrays for large apertures requiring more stability has generated several studies. The in-flight calibration and, therefore, the stability of such systems is an important design consideration. A 4.3 GHz laboratory radiometry operating in a balanced Dicke mode has been developed for making precise brightness (noise) temperature measurements. The stability of the noise diode source used in the noise-injection loop is of interest. A statistical Allan variance method to characterize the stability of the radiometer and the noise diode is presented in this paper. Noise measurements which demonstrate this approach are also included.

Scherner, M. J.↗

Application of a Planar Doppler Velocimetry System to a High Reynolds Number Compressible Jet

A Planar Doppler Velocimetry (PDV) system has been constructed and used to investigate the instantaneous turbulent velocity structure of a round high-speed compressible air jet with a low-speed co-flow. The exit condition was Mach=0.85 at ambient pressure, yielding a Reynolds number of about 650,000 on diameter. The PDV system was installed at NASA Langley Research Center in the Small Anechoic Jet Facility (SAJF), a chamber in which both the acoustic and aerodynamic properties of jets can be studied. For this test, the goal was to gather data which can be used to relate the turbulence structure of the jet to the levels and character of the acoustic noise produced by the jet. The current PDV system can acquire single-velocity-component, single-shot, planar images (15ns exposures) at 30 Hz. For this paper, the primary data set consists of 240 frames of velocity data acquired with both the jet and the low-speed co-flow seeded with light-scattering articles. Thus, velocities could be measured everywhere in the jet shear layer, both in the jet fluid and in the entrained co-flow. Some data were also taken with only the jet flow seeded. These provided mixing concentration images along with the reduced velocity fields. Other images were taken with only the co-flow seeded. These produced unique quantitative images of high speed entrainment. Optical "laser speckle" noise is the largest source of random noise in pulsed PDV systems. Components for the PDV imaging system were specifically selected to minimize speckle noise. To reduce systematic velocity errors due to laser drift, a frequency monitoring reference leg with a temperature-tuned reference iodine cell, was employed. In the course of this study, a novel flow seeder was developed. It enabled continuously variable seeding of the flow with particles of Sheared Pyrogenic Amorphous Hydrophobic Silica (SPAHS). The seeder comprised a dry fluidized bed hopper and a supersonic nozzle "pickup." Shearing action in the pickup dispersed the seed material in an exceptionally fine cloud (approximately 0.3 micron). These particles followed the flow well, did not clump or cake on screens or model surfaces, and were not susceptible to evaporation. Because of the refractory nature of the particles, SPAHS seeding should also be applicable to anticipated future testing at high temperatures.

Smith, Michael W.↗

Signal processing for ION mobility spectrometers

Signal processing techniques for systems based upon Ion Mobility Spectrometry will be discussed in the light of 10 years of experience in the design of real-time IMS. Among the topics to be covered are compensation techniques for variations in the number density of the gas - the use of an internal standard (a reference peak) or pressure and temperature sensors. Sources of noise and methods for noise reduction will be discussed together with resolution limitations and the ability of deconvolution techniques to improve resolving power. The use of neural networks (either by themselves or as a component part of a processing system) will be reviewed.

Taylor, S.↗